Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
J Comput Assist Tomogr ; 48(1): 150-155, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37551157

RESUMO

OBJECTIVE: Imaging is crucial in the assessment of head and neck cancers for site, extension, and enlarged lymph nodes. Restriction spectrum imaging (RSI) is a new diffusion-weighted magnetic resonance imaging (MRI) technique that enhances the ability to differentiate aggressive cancer from low-grade or benign tumors and helps guide treatment and biopsy. Its contribution to imaging of brain and prostate tumors has been previously published. However, there are no prior studies using RSI sequence in head and neck tumors. The purpose of this study was to evaluate the feasibility of performing RSI in head and neck cancer. METHODS: An additional RSI sequence was added in the routine MRI neck protocol for 13 patients diagnosed with head and neck cancer between November 2018 and April 2019. Restriction spectrum imaging sequence was performed with b values of 0, 500, 1500, and 3000 s/mm 2 and 29 directions on 1.5T magnetic resonance scanners.Diffusion-weighted imaging (DWI) images and RSI images were compared according to their ability to detect the primary malignancy and possible metastatic lymph nodes. RESULTS: In 71% of the patients, RSI outperformed DWI in detecting the primary malignancy and possible metastatic lymph nodes, whereas in the remaining cases, the 2 were comparable. In 66% of the patients, RSI detected malignant lymph nodes that DWI/apparent diffusion coefficient failed to detect. CONCLUSIONS: This is the first study of RSI in head and neck imaging and showed its superiority over the conventional DWI sequence. Because of its ability to differentiate benign and malignant lymph nodes in some cases, the addition of RSI to routine head and neck MRI should be considered.


Assuntos
Neoplasias de Cabeça e Pescoço , Masculino , Humanos , Projetos Piloto , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Linfonodos/patologia , Pescoço/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Sensibilidade e Especificidade
2.
Acta Radiol ; 65(4): 350-358, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38130123

RESUMO

BACKGROUND: UTE T2* cartilage mapping use in patients undergoing femoroacetabular impingement (FAI) has been lacking but may allow the detection of early cartilage damage. PURPOSE: To assess the reproducibility of UTE T2* cartilage mapping and determine the difference in UTE T2* values between FAI and asymptomatic patients and to evaluate the correlation between UTE T2* values and patient-reported symptoms. MATERIAL AND METHODS: Prospective evaluation of both hips (7 FAI and 7 asymptomatic patients). Bilateral hip 3-T MRI scans with UTE T2* cartilage maps were acquired. A second MRI scan was acquired 1-9 months later. Cartilage was segmented into anterosuperior, superior, and posterosuperior regions. Assessment was made of UTE T2* reproducibility (ICC). Mean UTE T2* values in patients were compared (t-tests) and correlation was made with patient-reported outcomes (Spearman's). RESULTS: ICCs of mean UTE T2* were as follows: acetabular, 0.82 (95% CI=0.50-0.95); femoral, 0.76 (95% CI=0.35-0.92). Significant strong correlation was found between mean acetabular UTE T2* values and iHOT12 (ρ = -0.63) and moderate correlation with mHHS (ρ = -0.57). There was no difference in mean UTE T2* values between affected vs. non-affected FAI hips. FAI-affected hips had significantly higher values in acetabulum vs. asymptomatic patients (13.47 vs. 12.55 ms). There was no difference in mean femoral cartilage values between the FAI-affected hips vs. asymptomatic patients. The posterosuperior femoral region had a higher mean value in non-affected FAI hips vs. asymptomatic patients (12.60 vs. 11.53 ms). CONCLUSION: UTE T2* cartilage mapping had excellent reproducibility. Affected FAI hips had higher mean acetabular UTE T2* values than asymptomatic patients. Severity of patient-reported symptoms correlates with UTE T2* acetabular cartilage values.


Assuntos
Cartilagem Articular , Impacto Femoroacetabular , Imageamento por Ressonância Magnética , Humanos , Impacto Femoroacetabular/diagnóstico por imagem , Feminino , Masculino , Projetos Piloto , Cartilagem Articular/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adulto , Estudos Prospectivos , Reprodutibilidade dos Testes , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/patologia , Adulto Jovem , Pessoa de Meia-Idade
3.
Magn Reson Imaging ; 99: 81-90, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36764630

RESUMO

Neuroimaging of certain pathologies requires both multi-parametric qualitative and quantitative imaging. The role of the quantitative MRI (qMRI) is well accepted but suffers from long acquisition times leading to patient discomfort, especially in geriatric and pediatric patients. Previous studies show that synthetic MRI can be used in order to reduce the scan time and provide qMRI as well as multi-contrast data. However, this approach suffers from artifacts such as partial volume and flow. In order to increase the scan efficiency (the number of contrasts and quantitative maps acquired per unit time), we designed, simulated, and demonstrated rapid, simultaneous, multi-contrast qualitative (T1 weighted, T1 fluid attenuated inversion recovery (FLAIR), T2 weighted, water, and fat), and quantitative imaging (T1 and T2 maps) through the approach of tailored MR fingerprinting (TMRF) to cover whole-brain in approximately four minutes. We performed TMRF on in vivo four healthy human brains and in vitro ISMRM/NIST phantom and compared with vendor supplied gold standard (GS) and MRF sequences. All scans were performed on a 3 T GE Premier system and images were reconstructed offline using MATLAB. The reconstructed qualitative images were then subjected to custom DL denoising and gradient anisotropic diffusion denoising. The quantitative tissue parametric maps were reconstructed using a dense neural network to gain computational speed compared to dictionary matching. The grey matter and white matter tissues in qualitative and quantitative data for the in vivo datasets were segmented semi-automatically. The SNR and mean contrasts were plotted and compared across all three methods. The GS images show better SNR in all four subjects compared to MRF and TMRF (GS > TMRF>MRF). The T1 and T2 values of MRF are relatively overestimated as compared to GS and TMRF. The scan efficiency for TMRF is 1.72 min-1 which is higher compared to GS (0.32 min-1) and MRF (0.90 min-1).


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Humanos , Criança , Idoso , Imageamento por Ressonância Magnética/métodos , Neuroimagem , Imagens de Fantasmas , Espectroscopia de Ressonância Magnética , Processamento de Imagem Assistida por Computador/métodos
4.
NMR Biomed ; 35(8): e4739, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35393706

RESUMO

B0 inhomogeneity leads to imaging artifacts in cardiac magnetic resonance imaging (MRI), in particular dark band artifacts with steady-state free precession pulse sequences. The limited spatial resolution of MR-derived in vivo B0 maps and the lack of population data prevent systematic analysis of the problem at hand and the development of optimized B0 shim strategies. We used readily available clinical computed tomography (CT) images to simulate the B0 conditions in the human heart at high spatial resolution. Calculated B0 fields showed consistency with MRI-based B0 measurements. The B0 maps for both the simulations and in vivo measurements showed local field inhomogeneities in the vicinity of lung tips with dominant Z3 spherical harmonic terms in the field distribution. The presented simulation approach allows for the derivation of B0 field conditions at high spatial resolution from CT images and enables the development of subject- and population-specific B0 shim strategies for the human heart.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Artefatos , Coração/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X
5.
Acta Radiol ; 63(6): 760-766, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33926266

RESUMO

BACKGROUND: Ultrashort echo time (UTE) T2* is sensitive to molecular changes within the deep calcified layer of cartilage. Feasibility of its use in the hip needs to be established to determine suitability for clinical use. PURPOSE: To establish feasibility of UTE T2* cartilage mapping in the hip and determine if differences in regional values exist. MATERIAL AND METHODS: MRI scans with UTE T2* cartilage maps were prospectively acquired on eight hips. Hip cartilage was segmented into whole and deep layers in anterosuperior, superior, and posterosuperior regions. Quantitative UTE T2* maps were analyzed (independent one-way ANOVA) and reliability was calculated (ICC). RESULTS: UTE T2* mean values (anterosuperior, superior, posterosuperior): full femoral layer (19.55, 18.43, 16.84 ms) (P=0.004), full acetabular layer (19.37, 17.50, 16.73 ms) (P=0.013), deep femoral layer (18.68, 17.90, 15.74 ms) (P=0.010), and deep acetabular layer (17.81, 16.18, 15.31 ms) (P=0.007). Values were higher in anterosuperior compared to posterosuperior regions (mean difference; 95% confidence interval [CI]): full femur layer (2.71 ms; 95% CI 0.91-4.51: P=0.003), deep femur layer (2.94 ms; 95% CI 0.69-5.19; P=0.009), full acetabular layer (2.63 ms 95% CI 0.55-4.72; P=0.012), and deep acetabular layer (2.50 ms; 95% CI 0.69-4.30; P=0.006). Intra-reader (ICC 0.89-0.99) and inter-reader reliability (ICC 0.63-0.96) were good to excellent for the majority of cartilage layers. CONCLUSION: UTE T2* cartilage mapping was feasible in the hip with mean values in the range of 16.84-19.55 ms in the femur and 16.73-19.37 ms in the acetabulum. Significantly higher values were present in the anterosuperior region compared to the posterosuperior region.


Assuntos
Cartilagem Articular , Cartilagem Articular/diagnóstico por imagem , Estudos de Viabilidade , Fêmur , Humanos , Imageamento por Ressonância Magnética , Projetos Piloto , Reprodutibilidade dos Testes
6.
J Comput Assist Tomogr ; 45(5): 717-721, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34347705

RESUMO

PURPOSE: Assess feasibility of ultrashort echo time (UTE) T2* cartilage mapping in sacroiliac (SI) joints. METHODS: Prospective magnetic resonance imagings with UTE T2* cartilage maps obtained on 20 SI joints in 10 subjects. Each joint was segmented into thirds by 2 radiologists. The UTE T2* maps were analyzed; reliability and differences in UTE T2* values between radiologists were assessed. RESULTS: Mean UTE T2* value was 10.44 ± 0.60 ms. No difference between right/left SI joints (median, 10.52 vs 10.45 ms; P = 0.940), men/women (median, 10.34 vs. 10.57 ms; P = 0.174), or different anatomic regions (median range 10.55-10.69 ms; P = 0.805). Intraclass correlation coefficients were 0.94 to 0.99 (intraobserver) and 0.91 to 0.96 (interobserver). Mean bias ± standard deviation on Bland-Altman was -0.137 ± 0.196 ms (limits of agreement -0.521 and 0.247) without proportional bias (ß = 0.148, P = 0.534). CONCLUSIONS: The UTE T2* cartilage mapping in the SI joints is feasible with high reader reliability.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Articulação Sacroilíaca/anatomia & histologia , Adulto , Estudos de Viabilidade , Feminino , Humanos , Masculino , Projetos Piloto , Estudos Prospectivos , Valores de Referência , Reprodutibilidade dos Testes
7.
PLoS One ; 16(6): e0252966, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34191819

RESUMO

Recent innovations in quantitative magnetic resonance imaging (MRI) measurement methods have led to improvements in accuracy, repeatability, and acquisition speed, and have prompted renewed interest to reevaluate the medical value of quantitative T1. The purpose of this study was to determine the bias and reproducibility of T1 measurements in a variety of MRI systems with an eye toward assessing the feasibility of applying diagnostic threshold T1 measurement across multiple clinical sites. We used the International Society of Magnetic Resonance in Medicine/National Institute of Standards and Technology (ISMRM/NIST) system phantom to assess variations of T1 measurements, using a slow, reference standard inversion recovery sequence and a rapid, commonly-available variable flip angle sequence, across MRI systems at 1.5 tesla (T) (two vendors, with number of MRI systems n = 9) and 3 T (three vendors, n = 18). We compared the T1 measurements from inversion recovery and variable flip angle scans to ISMRM/NIST phantom reference values using Analysis of Variance (ANOVA) to test for statistical differences between T1 measurements grouped according to MRI scanner manufacturers and/or static field strengths. The inversion recovery method had minor over- and under-estimations compared to the NMR-measured T1 values at both 1.5 T and 3 T. Variable flip angle measurements had substantially greater deviations from the NMR-measured T1 values than the inversion recovery measurements. At 3 T, the measured variable flip angle T1 for one vendor is significantly different than the other two vendors for most of the samples throughout the clinically relevant range of T1. There was no consistent pattern of discrepancy between vendors. We suggest establishing rigorous quality control procedures for validating quantitative MRI methods to promote confidence and stability in associated measurement techniques and to enable translation of diagnostic threshold from the research center to the entire clinical community.


Assuntos
Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/normas , Imagens de Fantasmas , Humanos , Valores de Referência , Reprodutibilidade dos Testes
8.
IEEE Trans Biomed Eng ; 68(8): 2499-2508, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33360980

RESUMO

OBJECTIVE: Focused ultrasound (FUS) has emerged as a non-invasive technique to locally and reversibly disrupt the blood-brain barrier (BBB). Here, we investigate the use of diffusion tensor imaging (DTI) as a means of detecting FUS-induced BBB opening at the absence of an MRI contrast agent. A non-human primate (NHP) was repeatedly treated with FUS and preformed circulating microbubbles to transiently disrupt the BBB (n = 4). T1- and diffusion-weighted MRI scans were acquired after the ultrasound treatment, with and without gadolinium-based contrast agent, respectively. Both scans were registered with a high-resolution T1-weighted scan of the NHP to investigate signal correlations. DTI detected an increase in fractional anisotropy from 0.21 ± 0.02 to 0.38 ± 0.03 (82.6 ± 5.2% change) within the targeted area one hour after BBB opening. Enhanced DTI contrast overlapped by 77.22 ± 9.2% with hyper-intense areas of gadolinium-enhanced T1-weighted scans, indicating diffusion anisotropy enhancement only within the BBB opening volume. Diffusion was highly anisotropic and unidirectional within the treated brain region, as indicated by the direction of the principal diffusion eigenvectors. Polar and azimuthal angle ranges decreased by 35.6% and 82.4%, respectively, following BBB opening. Evaluation of the detection methodology on a second NHP (n = 1) confirmed the across-animal feasibility of the technique. In conclusion, DTI may be used as a contrast-free MR imaging modality in lieu of contrast-enhanced T1 mapping for detecting BBB opening during focused-ultrasound treatment or evaluating BBB integrity in brain-related pathologies.


Assuntos
Barreira Hematoencefálica , Terapia por Ultrassom , Animais , Barreira Hematoencefálica/diagnóstico por imagem , Meios de Contraste , Imagem de Tensor de Difusão , Sistemas de Liberação de Medicamentos , Imageamento por Ressonância Magnética , Microbolhas
9.
Tomography ; 5(1): 36-43, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30854440

RESUMO

Quantitative kurtosis phantoms are sought by multicenter clinical trials to establish accuracy and precision of quantitative imaging biomarkers on the basis of diffusion kurtosis imaging (DKI) parameters. We designed and evaluated precision, reproducibility, and long-term stability of a novel isotropic (i)DKI phantom fabricated using four families of chemicals based on vesicular and lamellar mesophases of liquid crystal materials. The constructed iDKI phantoms included negative control monoexponential diffusion materials to independently characterize noise and model-induced bias in quantitative kurtosis parameters. Ten test-retest DKI studies were performed on four scanners at three imaging centers over a six-month period. The tested prototype phantoms exhibited physiologically relevant apparent diffusion, Dapp, and kurtosis, Kapp, parameters ranging between 0.4 and 1.1 (×10-3 mm2/s) and 0.8 and 1.7 (unitless), respectively. Measured kurtosis phantom Kapp exceeded maximum fit model bias (0.1) detected for negative control (zero kurtosis) materials. The material-specific parameter precision [95% CI for Dapp: 0.013-0.022(×10-3 mm2/s) and for Kapp: 0.009-0.076] derived from the test-retest analysis was sufficient to characterize thermal and temporal stability of the prototype DKI phantom through correlation analysis of inter-scan variability. The present study confirms a promising chemical design for stable quantitative DKI phantom based on vesicular mesophase of liquid crystal materials. Improvements to phantom preparation and temperature monitoring procedures have potential to enhance precision and reproducibility for future multicenter iDKI phantom studies.


Assuntos
Imagem de Difusão por Ressonância Magnética/normas , Imagens de Fantasmas/normas , Imagem de Difusão por Ressonância Magnética/métodos , Desenho de Equipamento , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Cristais Líquidos , Reprodutibilidade dos Testes , Temperatura
10.
JACC Heart Fail ; 7(2): 132-142, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30553901

RESUMO

Advanced imaging modalities provide essential anatomic and spatial information in patients with complex heart disease. Two-dimensional imaging can be limited in the extent to which true 3-dimensional (3D) relationships are represented. The application of 3D printing technology has increased the creation of physical models that overcomes the limitations of a 2D screen. Many groups have reported the use of 3D printing for preprocedural planning in patients with different causes of heart failure. This paper reviews the innovative applications of this technique to provide patient-specific models to improve patient care.


Assuntos
Insuficiência Cardíaca/diagnóstico por imagem , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente/tendências , Impressão Tridimensional/tendências , Humanos , Imagem Cinética por Ressonância Magnética , Tomografia Computadorizada por Raios X
11.
Chemistry ; 24(42): 10646-10652, 2018 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-29873848

RESUMO

High-relaxivity protein-complexes of GdIII are being pursued as MRI contrast agents in hope that they can be used at much lower doses that would minimize toxic-side effects of GdIII release from traditional contrast agents. We construct here a new type of protein-based MRI contrast agent, a proteinaceous cage based on a stable insulin hexamer in which GdIII is captured inside a water filled cavity. The macromolecular structure and the large number of "free" GdIII coordination sites available for water binding lead to exceptionally high relaxivities per one GdIII ion. The GdIII slowly diffuses out of this cage, but this diffusion can be prevented by addition of ligands that bind to the hexamer. The ligands that trigger structural changes in the hexamer, SCN- , Cl- and phenols, modulate relaxivities through an outside-in signaling that is allosterically transduced through the protein cage. Contrast-o-phores based on protein-caged metal ions have potential to become clinical contrast agents with environmentally-sensitive properties.


Assuntos
Gadolínio/química , Insulina/química , Íons/química , Água/química , Ligantes , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Estrutura Molecular
12.
JACC Cardiovasc Imaging ; 11(1): 64-74, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28823748

RESUMO

OBJECTIVES: This study sought to determine updated conversion factors (k-factors) that would enable accurate estimation of radiation effective dose (ED) for coronary computed tomography angiography (CTA) and calcium scoring performed on 12 contemporary scanner models and current clinical cardiac protocols and to compare these methods to the standard chest k-factor of 0.014 mSv·mGy-1cm-1. BACKGROUND: Accurate estimation of ED from cardiac CT scans is essential to meaningfully compare the benefits and risks of different cardiac imaging strategies and optimize test and protocol selection. Presently, ED from cardiac CT is generally estimated by multiplying a scanner-reported parameter, the dose-length product, by a k-factor which was determined for noncardiac chest CT, using single-slice scanners and a superseded definition of ED. METHODS: Metal-oxide-semiconductor field-effect transistor radiation detectors were positioned in organs of anthropomorphic phantoms, which were scanned using all cardiac protocols, 120 clinical protocols in total, on 12 CT scanners representing the spectrum of scanners from 5 manufacturers (GE, Hitachi, Philips, Siemens, Toshiba). Organ doses were determined for each protocol, and ED was calculated as defined in International Commission on Radiological Protection Publication 103. Effective doses and scanner-reported dose-length products were used to determine k-factors for each scanner model and protocol. RESULTS: k-Factors averaged 0.026 mSv·mGy-1cm-1 (95% confidence interval: 0.0258 to 0.0266) and ranged between 0.020 and 0.035 mSv·mGy-1cm-1. The standard chest k-factor underestimates ED by an average of 46%, ranging from 30% to 60%, depending on scanner, mode, and tube potential. Factors were higher for prospective axial versus retrospective helical scan modes, calcium scoring versus coronary CTA, and higher (100 to 120 kV) versus lower (80 kV) tube potential and varied among scanner models (range of average k-factors: 0.0229 to 0.0277 mSv·mGy-1cm-1). CONCLUSIONS: Cardiac k-factors for all scanners and protocols are considerably higher than the k-factor currently used to estimate ED of cardiac CT studies, suggesting that radiation doses from cardiac CT have been significantly and systematically underestimated. Using cardiac-specific factors can more accurately inform the benefit-risk calculus of cardiac-imaging strategies.


Assuntos
Angiografia por Tomografia Computadorizada/instrumentação , Angiografia Coronária/instrumentação , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Doses de Radiação , Tomógrafos Computadorizados , Calcificação Vascular/diagnóstico por imagem , Simulação por Computador , Desenho de Equipamento , Humanos , Imagens de Fantasmas , Valor Preditivo dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...