1.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38657209

RESUMO

AIMS: Primary prevention patients with ischaemic cardiomyopathy and chronic total occlusion of an infarct-related coronary artery (CTO) are at a particularly high risk of implantable cardioverter-defibrillator (ICD) therapy occurrence. The trial was designed to evaluate the efficacy of preventive CTO-related substrate ablation strategy in ischaemic cardiomyopathy patients undergoing primary prevention ICD implantation. METHODS AND RESULTS: The PREVENTIVE VT study was a prospective, multicentre, randomized trial including ischaemic patients with ejection fraction ≤40%, no documented ventricular arrhythmias (VAs), and evidence of scar related to the coronary CTO. Patients were randomly assigned 1:1 to a preventive substrate ablation before ICD implantation or standard therapy with ICD implantation only. The primary outcome was a composite of appropriate ICD therapy or unplanned hospitalization for VAs. Secondary outcomes included the primary outcome's components, the incidence of appropriate ICD therapies, cardiac hospitalization, electrical storm, and cardiovascular (CV) mortality. Sixty patients were included in the study. During the mean follow-up of 44.7 ± 20.7 months, the primary outcome occurred in 5 (16.7%) patients undergoing preventive substrate ablation and in 13 (43.3%) patients receiving only ICD [hazard ratio (HR): 0.33; 95% confidence interval (CI): 0.12-0.94; P = 0.037]. Patients in the preventive ablation group also had fewer appropriate ICD therapies (P = 0.039) and the electrical storms (Log-rank: P = 0.01). While preventive ablation also reduced cardiac hospitalizations (P = 0.006), it had no significant impact on CV mortality (P = 0.151). CONCLUSION: Preventive ablation of the coronary CTO-related substrate in patients undergoing primary ICD implantation is associated with the reduced risk of appropriate ICD therapy or unplanned hospitalization due to VAs.


Assuntos
Ablação por Cateter , Oclusão Coronária , Desfibriladores Implantáveis , Isquemia Miocárdica , Prevenção Primária , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Oclusão Coronária/mortalidade , Oclusão Coronária/terapia , Oclusão Coronária/prevenção & controle , Oclusão Coronária/complicações , Resultado do Tratamento , Estudos Prospectivos , Isquemia Miocárdica/complicações , Isquemia Miocárdica/mortalidade , Taquicardia Ventricular/prevenção & controle , Taquicardia Ventricular/terapia , Taquicardia Ventricular/mortalidade , Cardiomiopatias/mortalidade , Cardiomiopatias/complicações , Cardiomiopatias/terapia , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Fatores de Risco , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/mortalidade , Infarto do Miocárdio/mortalidade , Infarto do Miocárdio/prevenção & controle , Infarto do Miocárdio/complicações , Doença Crônica , Fatores de Tempo
2.
J Clin Med ; 12(23)2023 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-38068472

RESUMO

Although implantable cardioverter defibrillators offer the best protection against sudden cardiac death, catheter ablation for ventricular arrhythmias (VAs) can modify or prevent this event from occurring. In order to achieve a successful ablation, the correct identification of the underlying arrhythmogenic substrate is mandatory to tailor the pre-procedural planning of an ablative procedure as appropriately as possible. We propose that several of the imaging modalities currently used could be merged, including echocardiography (also intracardiac), cardiac magnetic resonance, cardiac computed tomography, nuclear techniques, and electroanatomic mapping. The aim of this state-of-the-art review is to present the value of each modality, that is, its benefits and limitations, in the assessment of arrhythmogenic substrate. Moreover, VAs can be also idiopathic, and in this paper we will underline the role of these techniques in facilitating the ablative procedure. Finally, a hands-on workflow for approaching such a VA and future perspectives will be presented.

3.
Children (Basel) ; 10(9)2023 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-37761474

RESUMO

Catheter ablation (CA) of supraventricular tachycardias (SVTs) is conventionally performed with the aid of X-ray fluoroscopy. Usage of a three-dimensional (3D) electro-anatomical mapping (EAM) system and intracardiac echocardiography (ICE) enables zero-fluoroscopy ablation, eliminating the harmful effects of radiation. We retrospectively analyzed the feasibility, effectiveness and safety of zero-fluoroscopy radiofrequency and cryoablation of various types of SVTs in pediatric patients. Overall, in 171 consecutive patients (12.5 ± 3.9 years), 175 SVTs were diagnosed and 201 procedures were performed. The procedural success rate was 98% (193/197), or more precisely, 100% (86/86) for AVNRT, 95.8% (91/95) for AVRT, 94.1% (16/17) for AT and 100% (2/2) for AFL. No complications were recorded. Follow-up was complete in 100% (171/171) of patients. During the mean follow-up period of 488.4 ± 409.5 days, 98.2% of patients were arrhythmia-free with long-term success rates of 98.7% (78/79), 97.5% (78/80), 100% (13/13) and 100% (2/2) for AVNRT, AVRT, AT and AFL, respectively. Zero-fluoroscopy CA of various types of SVTs in the pediatric population is a feasible, effective and safe treatment option.

4.
BMC Cardiovasc Disord ; 22(1): 98, 2022 03 13.
Artigo em Inglês | MEDLINE | ID: mdl-35282836

RESUMO

PURPOSE: The aim of this study was to evaluate the safety and efficacy of zero-fluoroscopy (ZF) catheter ablation (CA) for supraventricular tachycardias (SVT). METHODS: 584 consecutive patients referred to our institution for CA of SVT were analysed. Patients were categorised into two groups; zero-fluoroscopy (ZF) group and conventional fluoroscopy (CF) group. The ZF group was further divided into two subgroups (adults and paediatric). Patient characteristics, procedural information, and follow-up data were compared. RESULTS: The ZF group had a higher proportion of paediatric patients (42.2% vs 0.0%; p < 0.001), resulting in a younger age (30.9 ± 20.3 years vs 52.7 ± 16.5 years; p < 0.001) and lower BMI (22.8 ± 5.7 kg/m2 vs 27.0 ± 5.4 kg/m2; p < 0.001). Procedure time was shorter in the ZF group (94.2 ± 50.4 min vs 104.0 ± 54.0 min; p = 0.002). There were no major complications and the rate of minor complications did not differ between groups (0.0% vs 0.4%; p = 0.304). Acute procedural success as well as the long-term success rate when only the index procedure was considered did not differ between groups (92.5% vs 95.4%; p = 0.155; 87.1% vs 89.2%; p = 0.422). When repeated procedures were included, the long-term success rate was higher in the ZF group (98.3% vs 93.5%; p = 0.004). The difference can be partially explained by the operators' preferences. CONCLUSION: The safety and efficacy of ZF procedures in adult and paediatric populations are comparable to that of CF procedures.


Assuntos
Ablação por Cateter , Taquicardia Supraventricular , Adolescente , Adulto , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Criança , Fluoroscopia , Humanos , Pessoa de Meia-Idade , Taquicardia Supraventricular/diagnóstico por imagem , Taquicardia Supraventricular/cirurgia , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
5.
Acta Cardiol ; 77(3): 222-230, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34078244

RESUMO

Background: His bundle pacing (HBP) is a physiological alternative to biventricular (BiV) pacing. We compared short-term results of both pacing approaches in symptomatic atrial fibrillation (AF) patients with moderately reduced left ventricular (LV) ejection fraction (EF ≥35% and <50%) and narrow QRS (≤120 ms) who underwent atrioventricular node ablation (AVNA).Methods: Thirty consecutive AF patients who received BiV pacing or HBP in conjunction with AVNA between May 2015 and January 2020 were retrospectively assessed. Electrocardiographic, echocardiographic, and clinical data at baseline and 6 months after the procedure were assessed.Results: Twenty-four patients (age 68.8 ± 6.5 years, 50% female, EF 39.6 ± 4%, QRS 95 ± 10 ms) met the inclusion criteria, 12 received BiV pacing and 12 HBP. Both groups had similar acute procedure-related success and complication rates. HBP was superior to BiV pacing in terms of post-implant QRS duration, implantation fluoroscopy times, reduction of indexed LV volumes (EDVi 63.8 (49.6-81) mL/m2 vs. 79.9 (66-100) mL/m2, p = 0.055; ESVi 32.7 (25.6-42.6) mL/m2 vs. 46.4 (42.9-68.1) mL/m2, p = 0.009) and increase in LVEF (46 (41-55) % vs. 38 (35-42) %, p = 0.005). However, the improvement of the NYHA class was similar in both groups.Conclusions: In symptomatic AF patients with moderately reduced EF and narrow QRS undergoing AVNA, HBP could be a conceivable alternative to BiV pacing. Further prospective studies are warranted to address the outcomes between both 'ablate and pace' strategies.


Assuntos
Fibrilação Atrial , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Nó Atrioventricular/cirurgia , Fascículo Atrioventricular , Estimulação Cardíaca Artificial/métodos , Terapia de Ressincronização Cardíaca/métodos , Feminino , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Volume Sistólico , Resultado do Tratamento
6.
Clin Cardiol ; 44(8): 1177-1182, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34196416

RESUMO

BACKGROUND: Periprocedural pulmonary vein isolation (PVI) anticoagulation requires balancing between bleeding and thromboembolic risk. Intraprocedural anticoagulation is monitored by activated clotting time (ACT) with target value >300 s, and there are no guidelines specifying an initial unfractionated heparin (UFH) dose. METHODS: We aimed to assess differences in ACT values and UFH dosage during PVI in patients on different oral anticoagulants. We conducted an international, multi-center, registry-based study. Consecutive patients with atrial fibrillation (AF) undergoing PVI, on uninterrupted anticoagulation therapy, were analyzed. Before transseptal puncture, UFH bolus of 100 IU/kg was administered regardless of the anticoagulation drug. RESULTS: Total of 873 patients were included (median age 61 years, IQR 53-66; female 30%). There were 248, 248, 189, 188 patients on warfarin, dabigatran, rivaroxaban, and apixaban, respectively. Mean initial ACT was 257 ± 50 s, mean overall ACT 295 ± 45 s and total UFH dose 158 ± 60 IU/kg. Patients who were receiving warfarin and dabigatran compared to patients receiving rivaroxaban and apixaban had: (i) significantly higher initial ACT values (262 ± 57 and 270 ± 48 vs. 248 ± 42 and 241 ± 44 s, p < .001), (ii) significantly higher ACT throughout PVI (309 ± 46 and 306 ± 44 vs. 282 ± 37 and 272 ± 42 s, p < .001), and (iii) needed lower UFH dose during PVI (140 ± 39 and 157 ± 71 vs. 171 ± 52 and 172 ± 70 IU/kg). CONCLUSION: There are significant differences in ACT values and UFH dose during PVI in patients receiving different anticoagulants. Patients on warfarin and dabigatran had higher initial and overall ACT values and needed lower UFH dose to achieve adequate anticoagulation during PVI than patients on rivaroxaban and apixaban.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Idoso , Anticoagulantes/efeitos adversos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Dabigatrana/efeitos adversos , Feminino , Heparina/efeitos adversos , Humanos , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Piridonas/efeitos adversos , Rivaroxabana/efeitos adversos
7.
Pacing Clin Electrophysiol ; 44(9): 1487-1496, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34245035

RESUMO

BACKGROUND: Intracardiac echocardiography (ICE) has become an all-round tool for ablation of atrial fibrillation (AF) since it plays an important role in all procedural steps. The key upgrade to the usefulness of ICE is its integration into three-dimensional (3D) electroanatomic mapping (EAM) system (ICE/EAM automatic integration system). The aim of this single-center retrospective study was to evaluate feasibility, safety and acute efficacy of ICE/EAM automatic integration system guided fluoroless ablation of AF. METHODS: The study included patients with symptomatic paroxysmal or persistent AF undergoing first pulmonary vein isolation (PVI) radiofrequency (RF) catheter ablation (RFCA) from September 2017 to August 2020. All procedures were performed without the use of fluoroscopy. A detailed 3D virtual anatomy of the left atrium (LA) and structures relevant to AF ablation was constructed from ultrasound contours obtained with ICE probe inside the LA. Pulmonary veins (PVs) and antral regions were additionally mapped with fast anatomical mapping (FAM). PVI was performed with contact force (CF) sensing catheter. Procedural endpoint was successful PVI. RESULTS: A total of 98 consecutive patients underwent RFCA (34.7% females, median age 64.4 years, 64.3% paroxysmal AF). Acute PVI was achieved in all patients (100%). Forty-three patients (43.9%) underwent additional ablations for concomitant arrhythmias. Adverse events were detected in four patients (4.1%). The median procedure duration was 130 min (IQR 103.8-151.3). If only PVI was done the median procedure duration was 110.5 (IQR 100.0-133.8) CONCLUSIONS: ICE/EAM automatic integration system guided fluoroless ablation of AF is feasible, safe and acutely effective method for treatment of symptomatic AF.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Ecocardiografia Tridimensional , Veias Pulmonares/cirurgia , Idoso , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
8.
BMC Cardiovasc Disord ; 21(1): 306, 2021 06 16.
Artigo em Inglês | MEDLINE | ID: mdl-34134637

RESUMO

BACKGROUND: Conventional fluoroscopy guided catheter ablation (CA) is an established treatment option for ventricular arrhythmias (VAs). However, with the complex nature of most procedures, patients and staff bare an increased radiation exposure. Near-zero or zero-fluoroscopy CA is an alternative method which could substantially reduce or even eliminate the radiation dose. Our aim was to analyse procedural outcomes with fluoroscopy minimising approach for treatment of VAs in patients with structurally normal hearts (SNH) and structural heart disease (SHD). METHODS: Fifty-two (age 53.4 ± 17.8 years, 38 male, 14 female) consecutive patients who underwent CA of VAs in our institution between May 2018 and December 2019 were included. Procedures were performed primarily with the aid of the three-dimensional electro-anatomical mapping system and intra-cardiac echocardiography. Fluoroscopy was considered only in left ventricular (LV) summit mapping for coronary angiography and when epicardial approach was planned. Acute and long-term procedural outcomes were analysed. RESULTS: Sixty CA procedures were performed. Twenty-five patients had SHD-related VAs (Group 1) and 27 patients had SNH (Group 2). While Group 1 had significantly higher total procedural time (256.9 ± 71.7 vs 123.6 ± 42.2 min; p < 0.001) compared to Group 2, overall procedural success rate [77.4% (24/31) vs 89.7% (26/29); p = 0.20)] and recurrence rate after the first procedure [8/25, (32%) vs 8/27, (29.6%); p = 0.85] were similar in both groups. Fluoroscopy was used in 3 procedures in Group 1 where epicardial approach was needed and in 4 procedures in Group 2 where LV summit VAs were ablated. Overall procedure-related major complication rate was 5%. CONCLUSIONS: Fluoroscopy minimising approach for CA of VAs is feasible and safe in patients with SHD and SNH. Fluoroscopy could not be completely abolished in VAs with epicardial and LV summit substrate location.


Assuntos
Arritmias Cardíacas/cirurgia , Ablação por Cateter , Ecocardiografia , Exposição à Radiação/prevenção & controle , Proteção Radiológica , Radiografia Intervencionista , Ultrassonografia de Intervenção , Adulto , Idoso , Arritmias Cardíacas/diagnóstico por imagem , Arritmias Cardíacas/fisiopatologia , Ablação por Cateter/efeitos adversos , Ecocardiografia/efeitos adversos , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Fatores de Proteção , Doses de Radiação , Exposição à Radiação/efeitos adversos , Radiografia Intervencionista/efeitos adversos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia de Intervenção/efeitos adversos
9.
Int J Cardiovasc Imaging ; 37(6): 1873-1882, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33528712

RESUMO

Catheter radio-frequency ablation (RFA) and cryo-ablation (CRA) procedures are an effective and safe treatment options for adult and pediatric patients with accessory pathway (AP) mediated tachycardias. Non-fluoroscopic techniques during catheter ablation (CA) procedures reduce potentially harmful effects of radiation. Our aim was to investigate the efficacy and safety of completely fluoroless RFA and CRA procedures in pediatric and adult patients with APs. Consecutive patients with AP-related tachycardia and high risk asymptomatic ventricular pre-excitation were assessed in retrospective analysis. Three-dimensional (3D) electro-anatomical mapping (EAM) and intra-cardiac echocardiography (ICE) were used as principal imaging modalities. Fluoroscopy was not used during any stage of the procedures. Among 116 included patients (22.76 ± 16.1 years, 68 patients < 19 years), 60 had left-sided APs, 16 right-sided APs and 40 septal APs. Altogether, 96 had RFA and 20 CRA procedures. The acute success rates (ASR) of RFA and CRA were 97.9% and 95%, respectively (p = 0.43), with recurrence rates (RR) of 8.33% and 40%, respectively (p < 0.0001). The outcome difference was principally driven by lower RR with RFA in septal APs (9.1% vs. 38.9%, p = 0.025). Pediatric patients with APs (12.21 ± 3.76 years) had similar procedural parameters and outcomes compared to adult patients. There were no procedure-related complications. In adult and pediatric patients with AP-related tachycardias, both CRA and RFA can be effectively and safely performed without the use of fluoroscopy. In addition, RFA resulted in better outcomes compared to CRA.


Assuntos
Feixe Acessório Atrioventricular , Ablação por Cateter , Feixe Acessório Atrioventricular/diagnóstico por imagem , Feixe Acessório Atrioventricular/cirurgia , Adulto , Ablação por Cateter/efeitos adversos , Criança , Fluoroscopia , Humanos , Valor Preditivo dos Testes , Estudos Retrospectivos , Resultado do Tratamento
10.
J Interv Card Electrophysiol ; 61(3): 595-602, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32860178

RESUMO

BACKGROUND: Integration of intracardiac echocardiography (ICE) and 3D electroanatomic mapping (EAM) system allows transseptal punctures (TSP) without the use of fluoroscopy. Compared with fluoroscopy, ICE provides better visualization of the anatomy relevant to TSP and early recognition of complications. The aim was to evaluate efficacy and safety of entirely ICE-guided TSPs in patients who underwent fluoroless catheter ablation of left-sided tachycardias. METHODS: Consecutive 524 adult and pediatric patients referred to our institution from July 2014 to December 2019 were analyzed. Patients with cardiac implantable electronic devices (CIEDs) were also included. All procedures were performed with ICE-guided TSP combined with 3D EAM. Adverse events following TSP and within 30 days of the procedure were analyzed. RESULTS: Altogether 949 TSPs (363 double punctures, 76.5%) were performed in 586 fluoroless ablation procedures: 451 (77%) were ablation of atrial fibrillation or atypical flutter, 75 (12.8%) of left-sided accessory pathway, 33 (5.6%) of ventricular tachycardia, and 27 (4.6%) of focal atrial tachycardia. Forty-six (7.8%) procedures were performed in pediatric population and 36 procedures (6.1%) in patients with CIED. Only 2 TSPs were unsuccessful (2/949, 0.2%). Overall procedural complication rate was 1.9% (11/586 procedures). There was only 1 TSP-related pericardial tamponade (2/949, 0.2%). In CIED patients, there was 1 lead dislocation following TSP. CONCLUSIONS: Entirely ICE-guided TSPs for different left-sided tachycardias can be safely and effectively performed in adult and pediatric population without the use of fluoroscopy. However, caution is advised in CIED patients due to possible lead dislocation risk.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Taquicardia Supraventricular , Adulto , Fibrilação Atrial/cirurgia , Criança , Ecocardiografia , Fluoroscopia , Humanos , Punções , Taquicardia Supraventricular/cirurgia , Resultado do Tratamento
11.
Pacing Clin Electrophysiol ; 44(1): 199-202, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33118169

RESUMO

Pediatric patients with complete congenital atrio-ventricular (AV) block are generally exposed to life-long dyssynchronous right ventricular (RV) pacing. His bundle pacing (HBP) is an alternative method of pacing that better restores physiological ventricular activation which could prevent pacing-induced cardiomyopathy. We present a case of a 5-year-old child with complete AV block who underwent successful permanent HBP implantation. Three-dimensional electro-anatomical mapping system was used to facilitate the procedure and reduce the fluoroscopy time. There were no acute procedure-related complications, and electrical parameters were stable at short-term follow-up.


Assuntos
Bloqueio Atrioventricular/terapia , Estimulação Cardíaca Artificial/métodos , Mapeamento Epicárdico , Cardiopatias Congênitas/terapia , Bloqueio Atrioventricular/congênito , Pré-Escolar , Eletrocardiografia , Feminino , Fluoroscopia , Humanos
12.
J Interv Card Electrophysiol ; 61(1): 155-163, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32519224

RESUMO

BACKGROUND: Radiofrequency ablation (RFA) and cryo-ablation (CRA) have been traditionally performed with fluoroscopy which exposes patients and medical staff to the potential harmful effects of the X-ray. Therefore, we aimed to assess the feasibility, safety, and effectiveness of RFA and CRA of atrioventricular nodal reentry tachycardia (AVNRT) guided by the three-dimensional (3D) electro-anatomical mapping (EAM) system without the use of fluoroscopy. METHODS: We analyzed 168 consecutive patients with AVNRT, 62 of whom were under 19 years of age (128 in RFA (age 34.04 ± 21.0 years) and 40 in CRA (age 39.41 ± 22.8 years)). All procedures were performed completely without the use of the fluoroscopy and with the 3D EAM system. RESULTS: The acute success rates (ASR) of the two ablation methods were very high and similar (for RFA 126/128 (98.4%) and for CRA 40/40 (100%); p = 0.43). Total procedural time (TPT) was similar in RFA and CRA groups (75.04 ± 42.31 min and 73.12 ± 30.54 min, respectively; p = 0.79). Recurrence rates (1 (2.5%) and 8 (6.25%); p = 0.35) were similar. There were no complications associated with procedures in either group. In pediatric group, ASR (61/62 (98.38%) and 105/106 (99.05%), respectively; p = 0.69) and TPT (75.16 ± 42.2 min and 74.23 ± 38.3 min, respectively; p = 0.88) were similar to the adult group. High ASR was observed with both ablation methods (for RFA 49/50, 98%, and for CRA 12/12, 100%; p = 0.62] with very high arrhythmia-free survival rates (for RFA 98% and for CRA 100%; p = 0.62). CONCLUSION: Based on these results, it can be suggested that fluoroless RFA or CRA guided by the 3D EAM system can be routinely performed in all patients with AVNRT without compromising safety, efficacy, or duration of the procedure.


Assuntos
Ablação por Cateter , Criocirurgia , Taquicardia por Reentrada no Nó Atrioventricular , Adulto , Criança , Fluoroscopia , Humanos , Recém-Nascido , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico por imagem , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Resultado do Tratamento
13.
J Cardiothorac Surg ; 15(1): 258, 2020 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-32938486

RESUMO

BACKGROUND: Pocket-related complications following the implantation of cardiovascular implantable electronic devices primarily include pocket hematoma, infection, skin erosion or decubitus, device migration, and Twiddler's syndrome, with other pathologies such as nerve impairment or bone lesions being extremely rarely encountered. We report a case of a 20-year old asthenic, non-athlete female patient presenting with a device-generated fracture of the second rib several months after sub-muscular permanent pacemaker implantation due to repeated bilateral pre-pectoral pocket infections. CASE PRESENTATION: A 20-year old female patient was readmitted to our institution 9 months following sub-pectoral implantation of a permanent pacemaker, complaining of severe pocket-related pain, which arose spontaneously in the absence of direct trauma, intense physical activity or vigorous coughing, and was associated with normal day-to-day activity. To rule out a pacemaker re-infection, a native computed tomography and a positron emission tomography-computed tomography of the thorax were performed. Both modalities excluded an infection but showed a healing fracture and a focus of enhanced metabolic activity in the anterolateral part of the right second rib, indicating a non-traumatic or stress fracture of the bone. Consequently, a complete extraction of the pulse generator and both leads was performed and the smallest available single-chamber pulse generator with a single atrial electrode was implanted in the sub-fascial, pre-muscular pocket in the now recovered and uninfected left subclavicular region, alleviating patient's severe pain symptoms and significantly enhancing her quality of life. CONCLUSIONS: In the absence of direct trauma, intense physical activity or vigorous coughing, we assume that in this asthenic girl a normal day-to-day motion of the right shoulder has persistently forced the sub-muscularly placed pulse generator toward thoracic wall, putting increased repetitive pressure force on the underlying bones, finally causing a fatigue stress fracture of the second rib. In asthenic phenotype patients with small thorax and short subclavicular distance, a sub-muscular pacemaker implantation can potentially cause unique and unexpected pocket-related adverse events necessitating advanced diagnostics and timely treatment.


Assuntos
Fraturas de Estresse/diagnóstico , Marca-Passo Artificial/efeitos adversos , Fraturas das Costelas/diagnóstico , Diagnóstico Diferencial , Feminino , Fraturas de Estresse/diagnóstico por imagem , Fraturas de Estresse/etiologia , Humanos , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Qualidade de Vida , Fraturas das Costelas/diagnóstico por imagem , Fraturas das Costelas/etiologia , Tomografia Computadorizada por Raios X , Adulto Jovem
14.
Pacing Clin Electrophysiol ; 43(12): 1605-1608, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32681524

RESUMO

We present a case of successful cryoablation of the left extension of the atrioventricular (AV) node for treatment of a recurrent atrioventricular nodal reentry tachycardia without the use of fluoroscopy. Three-dimensional electroanatomic mapping system and intracardiac echocardiography were used to navigate catheters in the heart and position them according to anatomical landmarks. Due to the nature of cryoablation lesion formation, lesions were able to be applied safely in right atrium, as well as in left atrium, without damaging AV node or bundle of His.


Assuntos
Criocirurgia/métodos , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico por imagem , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Adulto , Ablação por Cateter , Ecocardiografia , Eletrocardiografia , Mapeamento Epicárdico , Feminino , Humanos , Reoperação , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia
15.
BMC Cardiovasc Disord ; 20(1): 210, 2020 05 06.
Artigo em Inglês | MEDLINE | ID: mdl-32375635

RESUMO

BACKGROUND: Right free wall accessory pathways (AP) are difficult to treat with catheter ablation as ablation catheter (AC) instability at the tricuspid annulus often precludes successful procedure. The aim of our study was to test a novel intra-cardiac echocardiography (ICE) guided technique for AC placement. Feasibility and success rates were observed. METHODS: Eight consecutive patients (aged 29 ± 21 years, 4 female) with Wolff-Parkinson-White syndrome and a right free wall AP were included in the study. ICE, three-dimensional (3D) electro-anatomic mapping (EAM) system, and a steerable long sheath were used together with either an irrigated or a non-irrigated tip radio-frequency AC to achieve a "loop" manoeuvre which provided AC tip stability at the ventricular aspect of the tricuspid annulus. X-ray fluoroscopy was not used. RESULTS: Three patients had an anterior and five had a lateral location of the right free wall AP. Procedures were successful in all patients, without recurrences during the mean follow-up of 397 ± 363 days. Average procedural duration was 90 ± 31 min. On average, 6.6 ± 5.7 ablations were needed. Average time to terminate AP conduction after the start of ablation was 4.8 ± 4.2 s. In five patients (62%) AP conduction was successfully terminated with the first ablation. There were no procedural complications. CONCLUSIONS: The novel ICE-guided approach with concomitant use of the steerable sheath and the 3D EAM system for zero-fluoroscopy mapping and ablation of the right free wall APs proved feasible and resulted in excellent acute and long-term outcomes.


Assuntos
Feixe Acessório Atrioventricular/cirurgia , Ablação por Cateter , Ecocardiografia , Ultrassonografia de Intervenção , Síndrome de Wolff-Parkinson-White/cirurgia , Feixe Acessório Atrioventricular/diagnóstico por imagem , Feixe Acessório Atrioventricular/fisiopatologia , Potenciais de Ação , Adolescente , Adulto , Cateteres Cardíacos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/instrumentação , Criança , Ecocardiografia/efeitos adversos , Estudos de Viabilidade , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia de Intervenção/efeitos adversos , Síndrome de Wolff-Parkinson-White/diagnóstico por imagem , Síndrome de Wolff-Parkinson-White/fisiopatologia , Adulto Jovem
16.
Int J Cardiovasc Imaging ; 36(3): 415-422, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31712932

RESUMO

Fluoroscopy is the principal imaging method for catheter ablation (CA) of atrial fibrillation (AF). However, radiation exposure carries potential health risk to patients and operators alike. Our aim was to study safety and efficacy of zero-fluoroscopy CA of paroxysmal AF with a combined use of electroanatomic mapping system (EAM) and intracardiac echocardiography (ICE). In addition, impact of ICE/EAM automatic integration system and contact force (CF) sensing technology on procedural times were assessed. We included 144 consecutive patients (69% males, age 60 ± 10 years, BMI 29 ± 4,6) referred for CA of symptomatic paroxysmal AF. All procedures were performed only with EAM system and ICE. No fluoroscopy was used. The acute procedural success of complete pulmonary vein isolation was achieved in all patients (100%) and adverse events were detected in eight patients (5.6%). In 53 (37%) patients the use of ICE/EAM automatic integration system shortened procedural times compared to those performed without it (148 ± 35 vs. 187 ± 44 min, p < 0.05). Similarly, 89 (60%) procedures where CF sensing catheter was used were shorter compared to those performed without it (163 ± 41 vs. 188 ± 46 min, p < 0.05). Zero-fluoroscopy approach for treatment of paroxysmal AF seems feasible, safe, and acutely effective. Additional reduction of procedural times could be achieved with the use of ICE/EAM automatic integration system and CF sensing technology.


Assuntos
Potenciais de Ação , Fibrilação Atrial/cirurgia , Ablação por Cateter , Ecocardiografia , Técnicas Eletrofisiológicas Cardíacas , Frequência Cardíaca , Veias Pulmonares/cirurgia , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Valor Preditivo dos Testes , Estudos Prospectivos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/fisiopatologia , Eslovênia , Fatores de Tempo , Resultado do Tratamento
18.
J Cardiovasc Electrophysiol ; 29(8): 1073-1080, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29722468

RESUMO

INTRODUCTION: While catheter ablation (CA) is an established treatment for symptomatic paroxysmal atrial fibrillation (AF), convergent epicardial and endocardial ablation procedure (CVP) has been primarily used to treat persistent AF. The aim of this single-center, prospective, randomized study was to compare treatment efficacy of CA and CVP in paroxysmal AF patients by monitoring AF, atrial tachycardia (AT), and atrial flutter (AFL) recurrence with Implantable Loop Recorder (ILR). METHODS AND RESULTS: Fifty patients (74% male) with history of paroxysmal AF were randomized between CA and CVP. Outcomes were determined by ILRs; every episode of AF/AT/AFL lasting 6 minutes or more was defined as a recurrence. AF burden (AFB) and required AF reinterventions (cardioversions and repeat ablations) were quantified after a 3-month blanking period. Total procedural (266 ± 44 vs. 242 ± 39 minutes) and ablation duration (52 ± 10 vs. 48 ± 12 minutes) was similar in both groups. Recurrence of AF/AT/AFL was more likely in the CA group compared to the CVP group (OR 3.78 (95% CI (1.17, 12.19), P  =  0.048)). During the follow-up period (mean 30.5 ± 6.9 months), higher AF burden and more reinterventions for recurrent AF were recorded in the CA group. There were more periprocedural complications in the CVP group (12.5%) compared to the CA group (0%). CONCLUSION: Treatment of paroxysmal AF with CVP showed less arrhythmia recurrence compared to CA. In addition, patients after CVP had fewer reinterventions and lower AF burden, but more periprocedural complications.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/prevenção & controle , Ablação por Cateter/métodos , Desfibriladores Implantáveis , Eletrocardiografia Ambulatorial/métodos , Idoso , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/tendências , Desfibriladores Implantáveis/tendências , Eletrocardiografia Ambulatorial/tendências , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
19.
J Cardiovasc Electrophysiol ; 29(1): 64-70, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28884872

RESUMO

INTRODUCTION: Frequent ventricular premature complexes (VPCs) may cause symptoms and/or lead to deterioration of LV systolic function. Although frequent VPCs may be abolished by catheter ablation, it may be challenging in case of their origin from the LV papillary muscles (PMs). Our collaborative study aimed to analyze in detail the site of origin and the outcome of ablation. METHODS: Consecutive 34 patients (males: 68%; aged 62 ± 12 years; LV ejection fraction: 50 ± 9%) undergoing catheter ablation of VPCs originating from PMs were included. All procedures were guided by intracardiac echocardiography. RESULTS: The size and shape of PMs were highly variable. The length of anterolateral and posteromedial PM was 23 ± 4 mm and 28 ± 7 mm, respectively. In about one-third of patients, the PM was formed by two distinctly separate heads. The ectopic foci were located on anterolateral, posteromedial or both PM in 35%, 56% and 9% of cases, respectively. Their location was found within the distal, mid, or proximal (basal) third of PM in the 67%, 19%, and 14%, respectively. A total of 86% of PM foci were acutely abolished and long-term success was achieved in 65% of patients. Absence of VPCs of other morphologies and a high burden of ectopic activity before ablation were associated with favorable clinical outcome. CONCLUSION: VPCs originate predominantly from the distal portion of the PM. This knowledge may facilitate the mapping in patients with infrequent ectopic beats. Intracardiac echocardiography is of crucial importance for navigation of the ablation catheter and for assessment of its stability at PM target sites.


Assuntos
Frequência Cardíaca , Ventrículos do Coração/fisiopatologia , Músculos Papilares/fisiopatologia , Função Ventricular Esquerda , Complexos Ventriculares Prematuros/fisiopatologia , Potenciais de Ação , Idoso , Ablação por Cateter , Ecocardiografia , Técnicas Eletrofisiológicas Cardíacas , Europa (Continente) , Feminino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Músculos Papilares/diagnóstico por imagem , Músculos Papilares/cirurgia , Fatores de Tempo , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia
SELEÇÃO DE REFERÊNCIAS