Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Dtsch Arztebl Int ; 120(25): 433, 2023 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-37661336
2.
Front Physiol ; 14: 1173171, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37256071

RESUMO

Introduction: Orthostatic dysregulation occurs during exposure to an increased gravitational vector and is especially common upon re-entering standard Earth gravity (1 g) after an extended period in microgravity (0 g). External peripheral skin cooling (PSC) has recently been described as a potent countermeasure against orthostatic dysregulation during heat stress and in lower body negative pressure (LBNP) studies. We therefore hypothesized that PSC may also be an effective countermeasure during hyper-gravity exposure (+Gz). Methods: To investigate this, we designed a randomized short-arm human centrifuge (SAHC) experiment ("Coolspin") to investigate whether PSC could act as a stabilizing factor in cardiovascular function during +Gz. Artificial gravity between +1 g and +4 g was generated by a SAHC. 18 healthy male volunteers completed two runs in the SAHC. PSC was applied during one of the two runs and the other run was conducted without cooling. Each run consisted of a 10-min baseline trial followed by a +Gz step protocol marked by increasing g-forces, with each step being 3 min long. The following parameters were measured: blood pressure (BP), heart rate (HR), stroke volume (SV), total peripheral resistance (TPR), cardiac output (CO). Furthermore, a cumulative stress index for each subject was calculated. Results: +Gz led to significant changes in primary as well as in secondary outcome parameters such as HR, SV, TPR, CO, and BP. However, none of the primary outcome parameters (HR, cumulative stress-index, BP) nor secondary outcome parameters (SV, TPR, CO) showed any significant differences-whether the subject was cooled or not cooled. Systolic BP did, however, tend to be higher amongst the PSC group. Conclusion: In conclusion, PSC during +Gz did not confer any significant impact on hemodynamic activity or orthostatic stability during +Gz. This may be due to lower PSC responsiveness of the test subjects, or an insufficient level of body surface area used for cooling. Further investigations are warranted in order to comprehensively pinpoint the exact degree of PSC needed to serve as a useful countermeasure system during +Gz.

3.
J Cardiopulm Rehabil Prev ; 42(5): 338-346, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-35420563

RESUMO

PURPOSE: Cardiac rehabilitation (CR) is evolving to include both in-person and virtual delivery. Our objective was to compare, in CR patients, the association of in-person, hybrid, and virtual CR with change in performance on the 6-min walk test (6MWT) between enrollment and completion. METHODS: Patients enrolled in CR between October 22, 2019, and May 10, 2021, were categorized into in-person, hybrid, or virtual groups by number of in-person and virtual visits. All patients received individualized exercise training and health behavior counseling. Cardiac rehabilitation was delivered to patients in the hybrid and virtual cohorts using synchronous video exercise and/or asynchronous telephone visits. Measurements at CR enrollment and completion included the 6MWT, blood pressure (BP), depression, anxiety, waist-to-hip ratio, and cardiac self-efficacy. RESULTS: Of 187 CR patients, 37/97 (38.1%) were in-person patients and 58/90 (64.4%) were hybrid/virtual patients ( P = .001). Compared to in-person (51.5 ± 59.4 m) improvement in the 6MWT was similar in hybrid (63.4 ± 55.6; P = .46) and virtual (63.2 ± 59.6; P = .55) compared with in-person (51.5 ± 59.4). Hybrid and virtual patients experienced similar improvements in BP control and anxiety. Virtual patients experienced less improvement in depression symptoms. There were no statistically significant changes in waist-to-hip ratio or cardiac self-efficacy. Qualitative themes included the adaptability of virtual CR, importance of relationships between patients and CR staff, and need for training and organizational adjustments to adopt virtual CR. CONCLUSIONS: Hybrid and virtual CR were associated with similar improvements in functional capacity to in-person. Virtual and hybrid CR have the potential to expand availability without compromising outcomes.


Assuntos
Reabilitação Cardíaca , Ansiedade , Exercício Físico , Humanos , Autoeficácia , Teste de Caminhada
5.
Front Med (Lausanne) ; 8: 666908, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34026794

RESUMO

Background: Precisely measuring the core body temperature during targeted temperature management after return of spontaneous circulation is mandatory, as deviations from the recommended temperature might result in side effects such as electrolyte imbalances or infections. However, previous methods are invasive and lack easy handling. A disposable, non-invasive temperature sensor using the heat flux approach (Double Sensor), was tested against the standard method: an esophagus thermometer. Methods: The sensor was placed on the forehead of adult patients (n = 25, M/F, median age 61 years) with return of spontaneous circulation after cardiac arrest undergoing targeted temperature management. The recorded temperatures were compared to the established measurement method of an esophageal thermometer. A paired t-test was performed to examine differences between methods. A Bland-Altman-Plot and the intraclass correlation coefficient were used to assess agreement and reliability. To rule out possible influence on measurements, the patients' medication was recorded as well. Results: Over the span of 1 year and 3 months, data from 25 patients were recorded. The t-test showed no significant difference between the two measuring methods (t = 1.47, p = 0.14, n = 1,319). Bland-Altman results showed a mean bias of 0.02°C (95% confidence interval 0.00-0.04) and 95% limits of agreement of -1.023°C and 1.066°C. The intraclass correlation coefficient was 0.94. No skin irritation or allergic reaction was observed where the sensor was placed. In six patients the bias differed noticeably from the rest of the participants, but no sex-based or ethnicity-based differences could be identified. Influences on the measurements of the Double Sensor by drugs administered could also be ruled out. Conclusions: This study could demonstrate that measuring the core body temperature with the non-invasive, disposable sensor shows excellent reliability during targeted temperature management after survived cardiac arrest. Nonetheless, clinical research concerning the implementation of the sensor in other fields of application should be supported, as well as verifying our results by a larger patient cohort to possibly improve the limits of agreement.

6.
Sci Total Environ ; 780: 146652, 2021 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-34030313

RESUMO

Along with industry and transportation, agriculture is one of the main sources of primary particulate matter (PM) emissions worldwide. Bioaerosol formation and PM release during livestock manure field application and the associated threats to environmental and human health are rarely investigated. In the temperate climate zone, field fertilization with manure seasonally contributes to local PM air pollution regularly twice per year (spring and autumn). Measurements in a wind tunnel, in the field and computational fluid dynamics (CFD) simulations were performed to analyze PM aerosolization during poultry manure application and the influence of manure moisture content and treatment. A positive correlation between manure dry matter content (DM) and PM release was observed. Therefore, treatments strongly increasing the DM of poultry manure should be avoided. However, high manure DM led to reduced microbial abundance and, therefore, to a lower risk of environmental pathogen dispersion. Considering the findings of PM and microbial measurements, the optimal poultry manure DM range for field fertilization was identified as 50-70%. Maximum PM10 concentrations of approx. 10 mg per m3 of air were measured during the spreading of dried manure (DM 80%), a concentration that is classified as strongly harmful. The modeling of PM aerosolization processes indicated a low health risk beyond a distance of 400 m from the manure application source. The detailed knowledge about PM aerosolization during manure field application was improved with this study, enabling manure management optimization for lower PM aerosolization and pathogenic release into the environment.

7.
Sensors (Basel) ; 20(21)2020 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-33142838

RESUMO

The direct measurement of emissions from naturally ventilated dairy barns is challenging due to their large openings and the turbulent and unsteady airflow at the inlets and outlets. The aim of this study was to quantify the impacts of the number and positions of sensors on the estimation of volume flow rate and emissions. High resolution measurements of a naturally ventilated scaled building model in an atmospheric boundary layer wind tunnel were done. Tracer gas was released inside the model and measured at the outlet area, using a fast flame ionization detector (FFID). Additionally, the normal velocity on the area was measured using laser Doppler anemometry (LDA). In total, for a matrix of 65 × 4 sensor positions, the mean normal velocities and the mean concentrations were measured and used to calculate the volume flow rate and the emissions. This dataset was used as a reference to assess the accuracy while systematically reducing the number of sensors and varying the positions of them. The results showed systematic errors in the emission estimation up to +97%, when measurements of concentration and velocity were done at one constant height. This error could be lowered under 5%, when the concentrations were measured as a vertical composite sample.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...