Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Int Emerg Nurs ; 76: 101506, 2024 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-39182473

RESUMO

BACKGROUND: Emergency departments (EDs) worldwide are dealing with overcrowding, system fragmentation, and coordination problems, which impact patient wait times, staff job satisfaction, and patient outcomes. Inappropriate ED visits, particularly those for low acuity conditions, exacerbate these challenges. However, the motivations behind these visits are poorly understood, with limited data from the patient perspective. This study investigated patient-reported motives behind ED visits triaged as low acuity in Poznan, Poland, to propose health care system flow enhancements. MATERIAL AND METHODS: A cross-sectional survey and retrospective chart review were conducted in the ED of the Hipolit Cegielski Medical Center in Poznan, Poland, over three months in 2022-23. Patients who were triaged to have low acuity conditions were invited to participate in the survey. The data collected through the questionnaire included patient and ED visit characteristics. Additional information on the visits was extracted from the patient charts. MAIN RESULTS: This study involved 293 patients who underwent low-acuity triage. Among them, 58 % were deemed to have conditions that could have been treated in primary care. Most of the patients (74 %) visited the ED of their own volition due to concerns about their health. Other reasons for ED attendance were challenges accessing primary care or a specialist clinic (11 %), system navigation problems (5 %), or a lack of trust in their primary care provider (2 %). CONCLUSIONS: This study showed that of the patients surveyed, the majority had conditions that could have been treated outside of the ED setting. We recommend prioritizing education, particularly among younger adults, to increase awareness about nonurgent care options while improving health care policies.

2.
J Clin Med ; 13(12)2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38930030

RESUMO

Background/Objectives: Implant treatment in patients who require teeth extraction due to periodontitis presents a significant challenge. The consideration of peri-implantitis is crucial when planning the placement of dental implants. The predictability of implant treatment relies on the suitability of both hard and soft tissue quality. The aim of this article is to present a case report demonstrating a secure treatment protocol for implant procedures in patients with periodontitis requiring the extraction of all teeth, soft tissue management targeted at increasing the keratinized mucosa zone, and the provision of a reliable prosthetic solution. The secondary objective is to review the relevant literature regarding the significance of keratinized mucosa surrounding dental implants and its association with the occurrence of peri-implantitis. Case presentation: A 65-year-old female with generalized periodontitis, stage IV grade C and very poor oral hygiene came for treatment and rehabilitation of the lower jaw. CBCT revealed periodontal lesions and labio-lingual ridge dimensions in the region of teeth 34-44 from 8.0 to 10.2 mm. The first surgery included teeth extraction and periodontal lesions enucleation with simultaneous placement of four implants in the positions of teeth 32, 34, 42, 44. The second-stage surgery involved increasing the keratinized mucosa using two free gingival grafts. Conclusions: The present case report described the treatment process of the patient with periodontitis, including immediate implantation in the infected region, soft tissue augmentation using free gingival grafts and the ultimate placement of a bar-retained overdenture for final restoration. After two years of observation, despite questionable hygiene, no symptoms of gingival inflammation were detected. Furthermore, there is limited information in the literature regarding the correlation between inadequate keratinized gingiva and the occurrence of peri-implantitis.

3.
Med Pr ; 75(2): 159-171, 2024 May 21.
Artigo em Polonês | MEDLINE | ID: mdl-38523548

RESUMO

This paper discusses the potential of additive printing, the risks it poses to users' health (including 3D printer operators) and the effects of chemical substances released during the printing based on the available in vitro and in vivo studies. It was shown that substances emitted during printing with the commonly used acrylonitrile butadiene styrene filament in additive manufacturing might have carcinogenic, hepatotoxic and teratogenic effects, as well as toxic effect on the respiratory system. The latest research on the mechanism of formation of particles and volatile organic compounds during 3D printing, the parameters affecting their potential emission, and trends in reducing these hazards are indicated. The need for the design of more environmentally friendly and less emissive printing materials, as well as strategies for prevention and individual and collective protection measures are emphasized. Users of 3D printers should be familiar with all possible aspects of the threats associated with the printing process. Insufficient data on direct exposure to chemicals and particles released during the use of filaments makes it difficult to build awareness of safe working practices. Of particular concern is the health impact of emitted chemicals and particles from thermally treated materials in one of the most popular technologies for 3D printing, i.e., fused deposition modelling. Exposure of the users to, e.g., plasticizers added to filaments occurs through a variety of routes, by absorption through the skin, by inhalation or ingestion. Available epidemiological data, as well as current experimental works, indicate that such exposure is a high risk of cardiovascular diseases, atherosclerosis in adults, and cardiac problems and metabolic disorders in children. This review, by identifying potential risk factors, may contribute to reducing the health loss of printer users and improving working conditions and safety, especially in enterprises where additive manufacturing technology is used. Med Pr Work Health Saf. 2024;75(2):159-171.


Assuntos
Exposição Ocupacional , Impressão Tridimensional , Humanos , Medição de Risco , Criança , Adulto
4.
Front Oncol ; 14: 1341084, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38322415

RESUMO

Introduction: Pembrolizumab combined with chemotherapy has become the standard of care for patients with non-small-cell lung cancer (NSCLC) and the expression of programmed death ligand 1 (PD-L1) in <50% of tumour cells (TC). Methods: We evaluated the efficacy of the treatment in real-world practice, paying attention to the predictive factors, with a special focus on low level of PD-L1 expression. This study is a multicenter retrospective analysis of patients with stage IV NSCLC. Results: A group of 339 consecutive patients was analysed, among them 51% patients with low PD-L1 expression. In the overall population, the ORR was 40.6%, median PFS and OS were 13 months (95% CI 11.4-15) and 16.8 months (95% CI 13.3-20.3), respectively. In multivariate analysis for the entire study population, performance status - ECOG 1 vs. 0 (HR 2.2, 95%CI 1.1-4.6; p=0.02), neutrophil to lymphocyte ratio (NLR)>3 (HR 2.3, 95%CI 1.3-4.2; p=0.04), presence of liver (HR 2.0, 95%CI 1-3.7; p=0. 03) and bone metastases (HR 1.3, 95%CI 1-3; p=0.04), weight loss (HR 1.8, 95%CI 1.1-2.8; p=0.01) and sum of measurable lesions diameters >110 mm (HR 1.7, 95%CI 1-2.9, p=0.049) had a negative impact on OS. Conclusions: In the real world, patients can clinically benefit from immunochemotherapy, regardless of the expression of PD-L1 and the histological type. Other clinicopathological factors such as performance status, extent, and location of secondary lesions have prognostic significance.

5.
Dentomaxillofac Radiol ; 53(1): 52-59, 2024 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-38214946

RESUMO

OBJECTIVES: To compare artificial intelligence (AI)-driven web-based platform and manual measurements for analysing facial asymmetry in craniofacial CT examinations. METHODS: The study included 95 craniofacial CT scans from patients aged 18-30 years. The degree of asymmetry was measured based on AI platform-predefined anatomical landmarks: sella (S), condylion (Co), anterior nasal spine (ANS), and menton (Me). The concordance between the results of automatic asymmetry reports and manual linear 3D measurements was calculated. The asymmetry rate (AR) indicator was determined for both automatic and manual measurements, and the concordance between them was calculated. The repeatability of manual measurements in 20 randomly selected subjects was assessed. The concordance of measurements of quantitative variables was assessed with interclass correlation coefficient (ICC) according to the Shrout and Fleiss classification. RESULTS: Erroneous AI tracings were found in 16.8% of cases, reducing the analysed cases to 79. The agreement between automatic and manual asymmetry measurements was very low (ICC < 0.3). A lack of agreement between AI and manual AR analysis (ICC type 3 = 0) was found. The repeatability of manual measurements and AR calculations showed excellent correlation (ICC type 2 > 0.947). CONCLUSIONS: The results indicate that the rate of tracing errors and lack of agreement with manual AR analysis make it impossible to use the tested AI platform to assess the degree of facial asymmetry.


Assuntos
Inteligência Artificial , Assimetria Facial , Humanos , Assimetria Facial/diagnóstico por imagem , Reprodutibilidade dos Testes , Imageamento Tridimensional/métodos , Cefalometria/métodos
6.
Breast Cancer Res Treat ; 204(2): 237-248, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38112922

RESUMO

PURPOSE: The interim analysis of the phase IIIb LUCY trial demonstrated the clinical effectiveness of olaparib in patients with germline BRCA-mutated (gBRCAm), human epidermal growth factor receptor 2 (HER2)-negative metastatic breast cancer (mBC), with median progression-free survival (PFS) of 8.11 months, which was similar to that in the olaparib arm of the phase III OlympiAD trial (7.03 months). This prespecified analysis provides final overall survival (OS) and safety data. METHODS: The open-label, single-arm LUCY trial of olaparib (300 mg, twice daily) enrolled adults with gBRCAm or somatic BRCA-mutated (sBRCAm), HER2-negative mBC. Patients had previously received a taxane or anthracycline for neoadjuvant/adjuvant or metastatic disease and up to two lines of chemotherapy for mBC. RESULTS: Of 563 patients screened, 256 (gBRCAm, n = 253; sBRCAm, n = 3) were enrolled. In the gBRCAm cohort, median investigator-assessed PFS (primary endpoint) was 8.18 months and median OS was 24.94 months. Olaparib was clinically effective in all prespecified subgroups: hormone receptor status, previous chemotherapy for mBC, previous platinum-based chemotherapy (including by line of therapy), and previous cyclin-dependent kinase 4/6 inhibitor use. The most frequent treatment-emergent adverse events (TEAEs) were nausea (55.3%) and anemia (39.2%). Few patients (6.3%) discontinued olaparib owing to a TEAE. No deaths associated with AEs occurred during the study treatment or 30-day follow-up. CONCLUSION: The LUCY patient population reflects a real-world population in line with the licensed indication of olaparib in mBC. These findings support the clinical effectiveness and safety of olaparib in patients with gBRCAm, HER2-negative mBC. CLINICAL TRIAL REGISTRATION: Clinical trials registration number: NCT03286842.


Assuntos
Neoplasias da Mama , Piperazinas , Adulto , Humanos , Feminino , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/genética , Mutação em Linhagem Germinativa , Resultado do Tratamento , Ftalazinas/efeitos adversos , Protocolos de Quimioterapia Combinada Antineoplásica/efeitos adversos
7.
Heliyon ; 9(10): e20700, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37876478

RESUMO

Rationale and objectives: Evaluation of the diagnostic value of linearly blended (LB) and virtual monoenergetic images (VMI) reconstruction techniques with and without metal artifacts reduction (MAR) and of adaptive statistical iterative reconstructions (ASIR) in the assessment of target vessels after branched/fenestrated endovascular aortic repair (f/brEVAR) procedures. Materials and methods: CT scans of 28 patients were used in this study. Arterial phase of examination was obtained using a dual-energy fast-kVp switching scanner. CT numbers in the aorta, celiac trunk, superior mesenteric artery, and renal arteries were measured in the following reconstructions: LB, VMI 60 keV, VMI MAR 60 keV, VMI ASIR 60 % 60 keV. Contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) were calculated for each reconstruction. Luminal diameters (measurements at 2 levels of stent) and subjective image quality (5-point Likert scale) were assessed (2 readers, blinded to the type of reconstruction). Results: The highest mean values of CNR and SNR in vascular structures were obtained in VMI MAR 60 keV (CNR 12.526 ± 2.46, SNR 17.398 ± 2.52), lower in VMI 60 keV (CNR 11.508 ± 2.01, SNR 16.524 ± 2.07) and VMI ASIR (CNR 11.086 ± 1.78, SNR 15.928 ± 1.82), and the lowest in LB (CNR 6.808 ± 0.79, SNR 11.492 ± 0.79) reconstructions. There were no statistically significant differences in the measurements of the stent width between reconstructions (p > 0.05). The highest subjective image quality was obtained in the ASIR VMI (4.25 ± 0.44) and the lowest in the MAR VMI (1.57 ± 0.5) reconstruction. Conclusion: Despite obtaining the highest values of SNR and CNR in the MAR VMI reconstruction, the subjective diagnostic value was the lowest for this technique due to significant artifacts. The type of reconstruction did not significantly affect vessel diameter measurements (p > 0.05). Iterative reconstructions raised both objective and subjective image quality.

8.
Arthritis Rheumatol ; 75(9): 1608-1618, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37098795

RESUMO

OBJECTIVE: This phase 3 study was undertaken to investigate the efficacy and safety of lenabasum, a cannabinoid type 2 receptor agonist, in patients with diffuse cutaneous systemic sclerosis (dcSSc). METHODS: A multinational double-blind study was conducted in 365 dcSSc patients who were randomized and dosed 1:1:1 with lenabasum 20 mg, lenabasum 5 mg, or placebo, each twice daily and added to background treatments, including immunosuppressive therapies (IST). RESULTS: The primary end point, the American College of Rheumatology combined response index in dcSSc (CRISS) at week 52 for lenabasum 20 mg twice a day versus placebo, was not met, with CRISS score of 0.888 versus 0.887 (P = 0.4972, using mixed models repeated measures [MMRM]). The change in the modified Rodnan skin thickness score (MRSS) at week 52 for lenabasum 20 mg twice a day versus placebo was -6.7 versus -8.1 (P = 0.1183, using MMRM). Prespecified analyses showed higher CRISS scores, greater improvement in MRSS, and lower decline in forced vital capacity in patients on background mycophenolate and those who were taking IST for ≤1 year. No deaths or excess in serious or severe adverse events related to lenabasum were observed. CONCLUSION: A benefit of lenabasum in dcSSc was not demonstrated. Most patients were treated with background IST, and treatment with mycophenolate mofetil in particular was associated with better outcomes. These findings support the use of IST in the treatment of dcSSc and highlight the challenge of demonstrating a treatment effect when investigational treatment is added to standard of care IST. These findings have relevance to trial design in SSc, as well as to clinical care.


Assuntos
Esclerodermia Difusa , Escleroderma Sistêmico , Humanos , Esclerodermia Difusa/tratamento farmacológico , Agonistas de Receptores de Canabinoides/uso terapêutico , Resultado do Tratamento , Índice de Gravidade de Doença , Dronabinol/uso terapêutico , Pele , Escleroderma Sistêmico/tratamento farmacológico
9.
Acad Radiol ; 30(12): 2813-2824, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37062628

RESUMO

OBJECTIVES: The objective of this prospective study was to evaluate the virtual monoenergetic images (VMI) and virtual noncontrast (VNC) phase in the detection of endoleaks after endovascular abdominal aortic repair (EVAR). The potential dose reduction of abbreviated examination protocols was calculated. MATERIALS AND METHODS: Ninety-seven patients after the EVAR procedure were enrolled in this study. An initial single-source noncontrast acquisition was followed by two dual-energy acquisitions (arterial and 60 s delayed). Fast-kVp switching scanner was used. VNC images were reconstructed from the delayed phase. First examination session (reference) included a full triphasic study protocol consisting of true noncontrast (TNC) images and two postcontrast phases, the latter ones presented as classical polyenergetic reconstructions. Reading sessions II and III were performed by two independent and blinded readers evaluating VMIs in abbreviated protocols-biphasic (VNC + arterial, delayed phase), monophasic (VNC + delayed phase). The diagnostic accuracy of sessions II and III was calculated. RESULTS: The calculated sensitivity of the biphasic protocol with the use of VMIs in endoleak detection was 100%, with a statistically significant increase in the number of endoleaks detected in comparison with the reference study. The monophasic protocol showed 83.33% sensitivity. The use of abbreviated examination protocols led to a decrease in the mean effective dose (ED) of 23.28% (biphasic protocol) and 61.37% (monophasic protocol). CONCLUSION: The use of VMIs increases the number of endoleaks diagnosed with a possible radiation reduction by up to » (biphasic protocol). Further reduction to a monophasic protocol leads to over 60% dose reduction but with a decrease in diagnostic accuracy.


Assuntos
Aneurisma da Aorta Abdominal , Angiografia por Tomografia Computadorizada , Humanos , Endoleak/diagnóstico por imagem , Estudos Prospectivos , Tomografia Computadorizada por Raios X/métodos , Correção Endovascular de Aneurisma , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Estudos Retrospectivos
10.
Soc Neurosci ; 18(1): 1-15, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-37062925

RESUMO

Self-concept clarity (SCC) refers to the extent to which self-beliefs are clearly and confidently defined, internally consistent, and stable. While there is an abundance of research showing an association between SCC, well-being, and effective self-regulation, there is little knowledge about how SCC relates to basic cognitive processes such as attention and memory. Drawing on the attentional function theory of cognitive control, we hypothesized that low SCC is associated with greater attentional control during a trait assessment task. We also expected that low SCC individuals retrieve self-related information from semantic memory less efficiently compared to high SCC individuals. Fifty participants took part in the ERP study. The P300 and N400 components were measured as electrophysiological indices of attentional and semantic processing. The results showed that individuals with low SCC had larger P300 amplitude in response to positive versus negative words, and marginally larger P300 amplitude in response to positive words compared to high SCC individuals. These results suggest greater attentional involvement in the processing of positive self-related information in people with low SCC. There were no significant differences between groups in N400 amplitude. The results are discussed in the context of the relationship of SCC to self-esteem and self-motive theory.


Assuntos
Eletroencefalografia , Potenciais Evocados , Humanos , Masculino , Feminino , Potenciais Evocados/fisiologia , Tempo de Reação/fisiologia , Autoimagem , Atenção/fisiologia
11.
Polymers (Basel) ; 15(7)2023 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-37050401

RESUMO

The pressure drop dynamics during the filtration of three-component mixture aerosols are investigated and compared with two and single-component aerosols. The main area of interest is the effect of the addition of a small quantity of liquid (oil) and solid (soot) particles during the filtration of aerosol containing water mist. In addition, calculations of the change in filter mass during oil aerosol filtration have been carried out and compared with the experimental results. The new, improved filtration efficiency model takes into account a better coefficient fitting in the filtration mechanism equations. The limitations in the change in fibre diameter and packing density resulting from the filter loading have been implemented in the model. Additionally, the calculation model employs the fibre size distribution representation via multiple average fibre diameters. The changes in fibre diameter are dependent on each fibre's calculated filtration efficiency. The improved filtration model has been utilised to predict the mass change of the filters during the filtration of pure and mixture aerosols. The pressure drop calculation model based on changes in filter mass has been formulated. The model is then utilised to calculate pressure drop changes resulting from the filtration of the oil aerosol and water and oil mixture aerosol.

12.
J Sleep Res ; 32(2): e13657, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-35712917

RESUMO

Several studies have shown that eveningness is positively related to both depressive and anxiety symptoms. However, little is known about factors that may play a protective role against the undesirable emotional consequences of evening preference. Thus, in the present study, we explored the moderating effects of dispositional mindfulness on the relationship between morningness-eveningness and the presence of depressive symptoms, as well as between morningness-eveningness and the presence of anxiety symptoms. The study was conducted on a group of 1107 individuals (559 women and 548 men) aged 18-55 years (M = 36.26, SD = 9.89). Consistent with previous findings, eveningness was positively related to the presence of both depressive and anxiety symptoms. The magnitude of these effects decreased with higher dispositional mindfulness. The latter result remained significant when the analogical moderating effects of personality, established in earlier studies, were controlled for in the regression models. This leads to the conclusion that dispositional mindfulness may act as a protective factor against the elevated depressive and anxiety symptoms reported by evening-oriented individuals.


Assuntos
Atenção Plena , Masculino , Humanos , Feminino , Ritmo Circadiano , Emoções , Ansiedade , Personalidade
13.
J Clin Med ; 11(20)2022 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-36294375

RESUMO

Tissue flossing is an increasingly popular method in physiotherapy and sports. There is a belief that tissue flossing can improve range of motion and muscle strength, shorten muscle recovery time, and reduce the risk of injury. The aim of this study was to analyse the effectiveness of tissue flossing for immediately improving muscle strength in recreational athletes when it is performed during warm-up. All participants were randomly assigned to either an experimental group (n = 36) or a control group (n = 34) using a random number generator. The experimental group (n = 36) performed an intervention comprising exercises with muscle tissue flossing and exercises without flossing. The control group (n = 30) performed the same protocol without a floss band. Muscle strength was measured for knee flexion end extension at three speeds (60, 120, and 180 °/s) 3 times. Analysed parameters include peak torque, work, and power related to body weight, flexors−extensors ratio, and time to peak torque. There were no significant changes in the muscle strength parameters from before to after the warm-up in either group (p > 0.05). Significantly lower values of peak torque, work, and power were observed in the experimental group during the warm-up with the floss band applied to muscles (p < 0.05). No clinically significant changes in time to peak torque or flexors−extensors ratio were observed. A single application of flossing does not improve muscle strength or power and can even reduce individuals' maximum muscle strength capabilities.

14.
PLoS One ; 17(5): e0267846, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35522668

RESUMO

Osimertnib is still widely used in the treatment of NSCLC patients who have previously received erlotinib, gefitinib or afatinib and have developed resistance to these drugs mediated by the T790M mutation in exon 20 of EGFR gene. We assessed the results of T790M mutation testing in liquid biopsy by Entrogen test and real-time PCR technique in routine clinical practice. Analysis was conducted in 73 plasma samples from 41 patients with locally advanced or metastatic lung adenocarcinoma treated with first- or second-generation of EGFR TKIs. We detected T790M mutation in 18 patients (43.9% of patients, 24.6% positive tests in 73 samples). The incidence of T790M mutation in liquid biopsy was significantly higher in patients with T3-T4 tumors compared to patients with T0-T2 tumors (p = 0.0368, χ2 = 4.36). Median PFS at the time of progression according to RECIST was significantly (p = 0.0444) higher in patients with T790M mutation than in patients without this mutation (22.5 vs. 15 months). Our results confirmed that T790M mutation is more often detected in patients with a large tumor spreading in the chest and with the long duration of response to first- or second generation of EGFR TKIs. The low sensitivity of the real-time PCR technique in T790M mutation detection could be partially compensated by repeating the tests.


Assuntos
Adenocarcinoma de Pulmão , Receptores ErbB , Neoplasias Pulmonares , Inibidores de Proteínas Quinases , Adenocarcinoma de Pulmão/tratamento farmacológico , Adenocarcinoma de Pulmão/genética , Adenocarcinoma de Pulmão/patologia , Resistencia a Medicamentos Antineoplásicos/genética , Receptores ErbB/genética , Humanos , Biópsia Líquida/métodos , Neoplasias Pulmonares/tratamento farmacológico , Neoplasias Pulmonares/genética , Neoplasias Pulmonares/patologia , Mutação , Inibidores de Proteínas Quinases/uso terapêutico
15.
Sensors (Basel) ; 22(10)2022 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-35632046

RESUMO

In 2019, the European Committee for Standardization (CEN) initiated work on the preparation of a strategy for air quality monitoring at workplaces. The aim was to determine the concentrations of nano-objects and their aggregates and agglomerates (NOAA) by means of direct measurements using low-cost sensors. There is a growing need for low-cost devices that can continuously monitor the concentrations of nanoparticles, and that can be installed where nanoparticles are used or created spontaneously. In search of such a device, in this study, a smoke detector with an ionization sensor was tested. The aim of the research was to investigate the response of the analog output signal with respect to changes in environmental parameters such as the relative humidity of air. The research was conducted in controlled laboratory conditions, and the results confirmed that an ionization detector could be used to measure the concentrations of nanoaerosols. The modified smoke detector detected soot particles smaller than 100 nm. The linear regression line was calculated for the relative humidity dataset and had a slope coefficient of -1.214 × 10-4; thus, the value of the output signal was constant during the experiment. The dependence on air temperature was approximated by a second-degree curve, with a slope coefficient of -8.113 × 10-2. Air humidity affected aerosol concentrations, which may be related to surface modification of nanoparticles.


Assuntos
Nanopartículas , Fumaça , Umidade , Fuligem , Temperatura
16.
Psychother Res ; 32(7): 910-921, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35188882

RESUMO

Objective: The Relational Depth Frequency Scale (RDFS) is a 6-item measure to assess the impact of relational depth experiences on psychotherapeutic outcomes. To date, the RDFS has only been validated in online samples of clinical and non-clinical individuals. This study aimed to examine the psychometric properties of the RDFS in clinical dyads of clients and psychotherapists.Method: A total of 86 psychotherapy dyads-86 psychotherapists (18 male, 68 female, mean age = 44.34) and 86 clients (17 male, 69 female, mean age = 34.22)-completed the RDFS, and the Scale to Assess the Psychotherapeutic Relationship (STAR), mid-psychotherapy.Results: CFA showed acceptable fit statistics for a one-factor model. The partial measurement invariance across both partners of the psychotherapeutic dyad was positively verified. The RDFS had good internal consistency for psychotherapists and clients (α = .90 and .81, respectively). Actor-partner interdependence model confirmed moderate to high levels of convergent validity against the STAR. Relational depth in both partners was predicted by their own perceptions of the quality of the psychotherapeutic relationship. Psychotherapist frequency of relational depth was also related to client perceptions of the psychotherapeutic relationship.Conclusion: The RDFS is a promising tool measuring relational depth both from psychotherapist and client perspectives.


Assuntos
Relações Profissional-Paciente , Psicoterapia , Adulto , Feminino , Humanos , Masculino , Psicometria , Psicoterapeutas , Resultado do Tratamento
17.
Clin Psychol Psychother ; 29(1): 250-259, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34125500

RESUMO

Previous studies on the therapists' burnout have focused on individual and environmental risk factors. This study aimed to analyse whether variables reflecting therapeutic relationship-the therapist experience of relational depth and quality of the therapeutic relationship-can be related to psychotherapist burnout. Four alternative path models were examined. A total of 101 humanistic-experiential psychotherapists, aged between 29 and 86 years, participated in the research. The Relational Depth Frequency Scale, the Scale to Assess the Therapeutic Relationship, the Psychological Well-Being Scale and the Link Burnout Questionnaire were applied to the research. The results showed that relational depth and therapeutic quality correlated negatively with psychotherapist burnout. Relational depth is the main predictor of psychological well-being and psychotherapist burnout through its effect on therapeutic quality. The experiences of relational depth, primarily of person-centred therapists, have positive psychological potential in predicting lower professional burnout.


Assuntos
Esgotamento Profissional , Psicoterapeutas , Adulto , Idoso , Idoso de 80 Anos ou mais , Esgotamento Profissional/terapia , Humanos , Pessoa de Meia-Idade , Psicoterapia/métodos , Inquéritos e Questionários
18.
Artigo em Inglês | MEDLINE | ID: mdl-34639402

RESUMO

The frequency of some sella turcica abnormalities on cephalometric radiographs is age related. Chronological age might not overlap with growth; however, no studies could be found on the association between sellar morphology and dental age. Although an association exists between sella turcica bridging and dental abnormalities, no studies have been found correlating sellar abnormalities other than bridging with dental abnormalities. The aim of this study was to find any correlations between sella turcica abnormalities and dental age or dental abnormalities. METHODS: Lateral cephalograms and panoramic radiographs of 206 children aged 6-15 years were analyzed for sela turcica abnormalities, Demirijan dental age, and dental abnormalities. RESULTS: The prevalence of dental abnormalities in patients with sela turcica abnormalities was 16.98%, while in those with normal sella, it was 3%. The differences between dental and chronological age were higher in patients with sella turcica abnormalities (p = 0.002). Dental abnormalities were more prevalent (p = 0.001) in patients with sellar abnormalities other than sellar bridging than in those with sellar bridging or normal sella. CONCLUSIONS: Sella turcica abnormalities are correlated with delayed dental age. Dental abnormalities are more frequent in patients with sellar abnormalities. Dental abnormalities are less frequent in subjects with sellar bridges compared to those with other sellar abnormalities.


Assuntos
Sela Túrcica , Cefalometria , Criança , Humanos , Polônia/epidemiologia , Radiografia , Radiografia Panorâmica , Sela Túrcica/diagnóstico por imagem
19.
Artigo em Inglês | MEDLINE | ID: mdl-33922272

RESUMO

BACKGROUND: The sella turcica is a saddle-like structure in the middle cranial fossa on the intracranial surface of the sphenoid bone, visible on lateral cephalograms routinely conducted for orthodontic diagnosis. The development of facial structures follows similar traits to the sella turcica: glandular anomalies may be associated with functional disorders, e.g., altered hormonal levels, thus influencing dental development. The aim of this study is to find out if there is any association between the morphology of the sella turcica on cephalometric radiographs and the presence of dental abnormalities. (2) Methods: The search was conducted on 27 January 2021 in four search engines: Medline (PubMed Central), Scopus, Web of Science, Embase. The keywords used in the search strategy were as follows: "sella turcica" AND ("dental abnormalities" OR "dental anomalies" OR "malocclusion"). Since all the studies finally included were retrospective case-control studies, the Newcastle-Ottawa Quality Assessment Form for Case-Control Studies was applied. (3) Results: The search strategy identified 465 articles: 289 from PubMed, 121 from Scopus, 32 from Web of Science and 23 from Embase. Finally, 10 full-text papers were included into qualitative analysis. (4) Conclusions: Sella turcica bridging is very frequent among orthodontic patients. A clear association exists between dental abnormalities and sella turcica bridging.


Assuntos
Má Oclusão , Sela Túrcica , Cefalometria , Humanos , Radiografia , Estudos Retrospectivos , Sela Túrcica/diagnóstico por imagem
20.
Adv Cogn Psychol ; 16(3): 213-227, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33072228

RESUMO

The current study aimed to determine relationships between oculomotor behavior and aesthetical evaluation of paintings. We hypothesized that paintings evaluated as beautiful compared to nonbeautiful would be associated with different oculomotor behavior in terms of fixation duration, viewing time, and temporal and spatial distribution of attention. To verify these hypotheses, we examined forty participants that looked at and evaluated 140 figurative paintings while their eye movements were recorded. To analyze data, we used divergence point analysis (DPA) and recurrence quantification analysis (RQA). The results of the DPA suggested that fixation durations longer than 229 ms are sensitive to the effect of aesthetical evaluation. We also found that the effect of aesthetical evaluation was significant in the time window between 2.3 s and 19.8 s of viewing a painting. The results of the RQA suggested that the participants viewed paintings evaluated as beautiful in a more structured manner compared to those evaluated as nonbeautiful, which suggests higher involvement of top-down processes while facing beautiful artwork. We discuss and refer these results to the literature on cognitive processes related to aesthetical evaluation of paintings.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA