Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 176
Filtrar
1.
Histochem Cell Biol ; 155(1): 19-73, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33040183

RESUMO

This multidisciplinary study examined the pharmacokinetics of nanoparticles based on albumin-DTPA-gadolinium chelates, testing the hypothesis that these nanoparticles create a stronger vessel signal than conventional gadolinium-based contrast agents and exploring if they are safe for clinical use. Nanoparticles based on human serum albumin, bearing gadolinium and designed for use in magnetic resonance imaging, were used to generate magnet resonance images (MRI) of the vascular system in rats ("blood pool imaging"). At the low nanoparticle doses used for radionuclide imaging, nanoparticle-associated metals were cleared from the blood into the liver during the first 4 h after nanoparticle application. At the higher doses required for MRI, the liver became saturated and kidney and spleen acted as additional sinks for the metals, and accounted for most processing of the nanoparticles. The multiple components of the nanoparticles were cleared independently of one another. Albumin was detected in liver, spleen, and kidneys for up to 2 days after intravenous injection. Gadolinium was retained in the liver, kidneys, and spleen in significant concentrations for much longer. Gadolinium was present as significant fractions of initial dose for longer than 2 weeks after application, and gadolinium clearance was only complete after 6 weeks. Our analysis could not account quantitatively for the full dose of gadolinium that was applied, but numerous organs were found to contain gadolinium in the collagen of their connective tissues. Multiple lines of evidence indicated intracellular processing opening the DTPA chelates and leading to gadolinium long-term storage, in particular inside lysosomes. Turnover of the stored gadolinium was found to occur in soluble form in the kidneys, the liver, and the colon for up to 3 weeks after application. Gadolinium overload poses a significant hazard due to the high toxicity of free gadolinium ions. We discuss the relevance of our findings to gadolinium-deposition diseases.


Assuntos
Albuminas/farmacocinética , Quelantes/farmacocinética , Meios de Contraste/farmacocinética , Gadolínio DTPA/farmacocinética , Imageamento por Ressonância Magnética , Nanopartículas/química , Albuminas/administração & dosagem , Animais , Quelantes/administração & dosagem , Meios de Contraste/administração & dosagem , Feminino , Gadolínio DTPA/administração & dosagem , Injeções Intravenosas , Masculino , Camundongos , Camundongos Endogâmicos BALB C , Nanopartículas/administração & dosagem , Ratos , Ratos Sprague-Dawley , Distribuição Tecidual
2.
Eur Radiol ; 30(11): 5826-5833, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32535737

RESUMO

OBJECTIVES: To assess clinically relevant difference in hepatic iron quantification using R2* relaxometry with (FS) and without (non-FS) fat saturation for the evaluation of patients with suspected hepatic iron overload. METHODS: We prospectively enrolled 134 patients who underwent 1.5-T MRI R2* relaxometry with FS and non-FS gradient echo sequences (12 echoes, initial TE = 0.99 ms). Proton density fat fraction for the quantification of steatosis was assessed. Linear regression analyses and Bland-Altman plots including Lin's concordance correlation coefficient were performed for correlation of FS R2* with non-FS R2*. Patients were grouped into 4 severity classes of iron overload (EASL based), and agreement was evaluated by contingency tables and the proportion of overall agreement. RESULTS: A total of 41.8% of patients showed hepatic iron overload; 67.9% had concomitant steatosis; and 58.2% revealed no iron overload of whom 60.3% had steatosis. The mean R2* value for all FS data was 102.86 1/s, for non-FS 108.16 1/s. Linear regression resulted in an R-squared value of 0.99 (p < 0.001); Bland-Altman plot showed a mean R2* difference of 5.26 1/s (SD 17.82). The concordance correlation coefficient was only slightly lower for patients with steatosis compared with non-steatosis (0.988 vs. 0.993). The overall agreement between FS and non-FS R2* measurements was 94.8% using either method to classify patients according to severity of iron storage. No correlation between R2* and proton density fat fraction was found for both methods. CONCLUSION: R2* relaxometry showed an excellent overall agreement between FS and non-FS acquisition. Both variants can therefore be used in daily routine. However, clinically relevant differences might result when switching between the two methods or during patient follow-up, when fat content changes over time. We therefore recommend choosing a method and keeping it straight in the context of follow-up examinations. KEY POINTS: • Both variants of R2* relaxometry (FS and non-FS) may be used in daily routine. • Clinically relevant differences might result when switching between the two methods or during patient follow-up, when fat content changes over time. • It seems advisable choosing one method and keeping it straight in the context of follow-up examinations.


Assuntos
Fígado Gorduroso/diagnóstico , Sobrecarga de Ferro/diagnóstico , Ferro/metabolismo , Fígado/metabolismo , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Fígado Gorduroso/etiologia , Fígado Gorduroso/metabolismo , Feminino , Humanos , Sobrecarga de Ferro/complicações , Sobrecarga de Ferro/metabolismo , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Adulto Jovem
3.
Eur Radiol ; 29(2): 829-837, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30027410

RESUMO

OBJECTIVES: To assess if the administration of gadoxetate disodium (Gd-EOB-DTPA) significantly affects hepatic magnetic resonance elastography (MRE) measurements in the delayed hepatobiliary phase (DHBP). METHODS: A total of 47 patients (15 females, 32 males; age range 23-78 years, mean 54.28 years) were assigned to standard hepatic magnetic resonance imaging (MRI) with application of Gd-EOB-DTPA and hepatic MRE. MRE was performed before injection of Gd-EOB-DTPA and after 40-50 min in the DHBP. Liver stiffness values were obtained before and after contrast media application and differences between pre- and post-Gd-EOB-DTPA values were evaluated using a Bland-Altman plot and the Mann-Whitney-Wilcoxon test. In addition, the data were compared with regard to the resulting fibrosis classification. RESULTS: Mean hepatic stiffness for pre-Gd-EOB-DTPA measurements was 4.01 kPa and post-Gd-EOB-DTPA measurements yielded 3.95 kPa. We found a highly significant individual correlation between pre- and post-Gd-EOB-DTPA stiffness values (Pearson correlation coefficient of r = 0.95 (p < 0.001) with no significant difference between the two measurements (p =0.49)). Bland-Altman plot did not show a systematic effect for the difference between pre- and post-stiffness measurements (mean difference: 0.06 kPa, SD 0.81). Regarding the classification of fibrosis stages, the overall agreement was 87.23% and the intraclass correlation coefficient was 96.4%, indicating excellent agreement. CONCLUSIONS: Administration of Gd-EOB-DTPA does not significantly influence MRE stiffness measurements of the liver in the DHBP. Therefore, MRE can be performed in the DHBP. KEY POINTS: • MRE of the liver can reliably be performed in the delayed hepatobiliary phase. • Gd-EOB-DTPA does not significantly influence MRE stiffness measurements of the liver. • MRE performed in the delayed hepatobiliary-phase is reasonable in patients with reduced liver function.


Assuntos
Meios de Contraste , Técnicas de Imagem por Elasticidade/métodos , Gadolínio DTPA , Hepatopatias/diagnóstico por imagem , Fígado/diagnóstico por imagem , Adulto , Idoso , Meios de Contraste/administração & dosagem , Feminino , Humanos , Fígado/patologia , Cirrose Hepática/diagnóstico por imagem , Hepatopatias/patologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
4.
Eur Surg ; 50(3): 117-124, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29875800

RESUMO

BACKGROUND: Percutaneous ablation techniques offer a vast armamentarium for local, minimally invasive treatment of liver tumors, nowadays representing an established therapeutic option, which is integrated in treatment algorithms, especially for non-resectable liver tumors. The results of ablative treatment compare very well to surgical treatment in liver lesions, and confirm that these techniques are a valuable option for bridging for transplantation. Different techniques have been established to perform tumor ablation, and the feasibility varies according to the procedure and technical skills of the operator, depending on the size and location of the liver lesion. In recent years, stereotactic multi-needle techniques using 3D trajectory planning, general anesthesia, and tube disconnection during needle placement have had a strong impact on the application range of ablation for liver tumors. CONCLUSION: It is well known that creating a sufficient ablation margin and overlapping ablation zones is one key issue to enable ablation of large liver lesions with tumor-free margins (A0 ablation in analogy to R0 resection). Image fusion during treatment and follow-up assure highly accurate staging procedures and interventional planning. NOVEL ASPECTS: Review on the standards in ablation techniques for the treatment of liver tumors. Update on different ablation techniques, indications, and contraindications for percutaneous liver tumor treatment. Summary of recently published reports on liver tumor ablation.

5.
Eur J Radiol ; 102: 74-82, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29685548

RESUMO

PURPOSE: To prospectively evaluate a prototypical 3D turbo-spin-echo proton-density-weighted sequence with compressed sensing and free-stop scan mode for preventing motion artefacts (3D-PD-CS-SPACE free-stop) for knee imaging in a clinical setting. METHODS AND MATERIALS: 80 patients underwent 3T magnetic resonance imaging (MRI) of the knee with our 2D routine protocol and with 3D-PD-CS-SPACE free-stop. In case of a scan-stop caused by motion (images are calculated nevertheless) the sequence was repeated without free-stop mode. All scans were evaluated by 2 radiologists concerning image quality of the 3D-PD-CS-SPACE (with and without free-stop). Important knee structures were further assessed in a lesion based analysis and compared to our reference 2D-PD-fs sequences. RESULTS: Image quality of the 3D-PD-CS-SPACE free-stop was found optimal in 47/80, slightly compromised in 21/80, moderately in 10/80 and severely in 2/80. In 29/80, the free-stop scan mode stopped the 3D-PD-CS-SPACE due to subject motion with a slight increase of image quality at longer effective acquisition times. Compared to the 3D-PD-CS-SPACE with free-stop, the image quality of the acquired 3D-PD-CS-SPACE without free-stop was found equal in 6/29, slightly improved in 13/29, improved with equal contours in 8/29, and improved with sharper contours in 2/29. The lesion based analysis showed a high agreement between the results from the 3D-PD-CS-SPACE free-stop and our 2D-PD-fs routine protocol (overall agreement 96.25%-100%, Cohen's Kappa 0.883-1, p < 0.001). CONCLUSION: 3D-PD-CS-SPACE free-stop is a reliable alternative for standard 2D-PD-fs protocols with acceptable acquisition times.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Articulação do Joelho/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Feminino , Humanos , Traumatismos do Joelho/diagnóstico por imagem , Traumatismos do Joelho/patologia , Articulação do Joelho/patologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Prótons , Reprodutibilidade dos Testes , Adulto Jovem
6.
Radiologe ; 57(10): 840-849, 2017 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-28733704

RESUMO

BACKGROUND: The increasing use of immunotherapy in oncology increases the need for radiologic evaluation of frequent and severe immune-related adverse events. OBJECTIVE: Determination of the incidence and manifestation of radiologic and nuclear medicine findings of immune-related adverse events. MATERIAL AND METHODS: Literature review of clinical and imaging findings of immune-related adverse events induced by the immune checkpoint inhibitors ipilimumab, nivolumab and pembrolizumab. Findings are illustrated with pictorial examples and contrasted to other relevant differential diagnoses. RESULTS: The most frequent imaging manifestations are colitis, hepatitis, pancreatitis, hypophysitis, pneumonitis, arthritis and sarcoid-like lymphadenopathy. Severe to life-threatening complications may result from colitis, pneumonitis and hypophysitis. A clear differentiation from other autoimmune diseases and discrimination of immune-related and infectious pulmonary findings can be very difficult and need close multidisciplinary collaboration. CONCLUSION: Knowledge of clinical and imaging findings of adverse events induced by immunotherapy is essential for timely and adequate therapeutic decisions. In addition to staging and follow-up imaging, identification and monitoring of immune-related adverse events adds to the radiologic responsibility in oncologic care.


Assuntos
Imunoterapia/efeitos adversos , Neoplasias/terapia , Humanos , Neoplasias/diagnóstico por imagem , Medicina Nuclear , Resultado do Tratamento
7.
Eur J Radiol ; 89: 149-155, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28267532

RESUMO

PURPOSE: To evaluate pancreatic iron in patients with human hemochromatosis protein associated hereditary hemochromatosis (HHC) using R2* relaxometry. MATERIALS AND METHODS: 81 patients (58 male, 23 female; median age 49.5, range 10-81 years) with HHC were retrospectively studied. All underwent 1.5T magnetic resonance imaging (MRI) of the abdomen. A fat-saturated multi-gradient echo sequence with 12 echoes (TR=200ms; TE-initial 0.99ms; Delta-TE 1.41ms; 12 echoes; flip-angle: 20°) was used for the R2* quantification of the liver and the pancreas. Parameter maps were analyzed using regions of interest (3 in the liver and 2 in the pancreas) and R2* values were correlated. RESULTS: 59/81 patients had a liver R2*≥70 1/s of which 10/59 patients had a pancreas R2*≥50 1/s. No patient presented with a liver R2*<70 1/s and pancreas R2*≥50 1/s. All patients with pancreas R2* values≥50 1/s had liver R2* values≥70 1/s. ROC analysis resulted in a threshold of 209.4 1/s for liver R2* values to identify HFE positive patients with pancreas R2* values≥50 1/s with a median specificity of 78.87% and a median sensitivity of 90%. CONCLUSION: In patients with HHC R2* relaxometry of the pancreas should be performed when liver iron overload is present and can be omitted in cases with no sign of hepatic iron.


Assuntos
Proteína da Hemocromatose/genética , Hemocromatose/genética , Pâncreas/patologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Feminino , Hemocromatose/patologia , Humanos , Ferro/metabolismo , Sobrecarga de Ferro/patologia , Fígado/patologia , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Curva ROC , Estudos Retrospectivos , Sensibilidade e Especificidade , Adulto Jovem
9.
Rofo ; 188(5): 470-8, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27074422

RESUMO

PURPOSE: We compared the targeting accuracy and reliability of two different electromagnetic navigation systems for manually guided punctures in a phantom. MATERIALS AND METHODS: CT data sets of a gelatin filled plexiglass phantom were acquired with 1, 3, and 5 mm slice thickness. After paired-point registration of the phantom, a total of 480 navigated stereotactic needle insertions were performed manually using electromagnetic guidance with two different navigation systems (Medtronic Stealth Station: AxiEM; Philips: PercuNav). A control CT was obtained to measure the target positioning error between the planned and actual needle trajectory. RESULTS: Using the Philips PercuNav, the accomplished Euclidean distances were 4.42 ±â€Š1.33 mm, 4.26 ±â€Š1.32 mm, and 4.46 ±â€Š1.56 mm at a slice thickness of 1, 3, and 5 mm, respectively. The mean lateral positional errors were 3.84 ±â€Š1.59 mm, 3.84 ±â€Š1.43 mm, and 3.81 ±â€Š1.71 mm, respectively. Using the Medtronic Stealth Station AxiEM, the Euclidean distances were 3.86 ±â€Š2.28 mm, 3.74 ±â€Š2.1 mm, and 4.81 ±â€Š2.07 mm at a slice thickness of 1, 3, and 5 mm, respectively. The mean lateral positional errors were 3.29 ±â€Š1.52 mm, 3.16 ±â€Š1.52 mm, and 3.93 ±â€Š1.68 mm, respectively. CONCLUSION: Both electromagnetic navigation devices showed excellent results regarding puncture accuracy in a phantom model. The Medtronic Stealth Station AxiEM provided more accurate results in comparison to the Philips PercuNav for CT with 3 mm slice thickness. One potential benefit of electromagnetic navigation devices is the absence of visual contact between the instrument and the sensor system. Due to possible interference with metal objects, incorrect position sensing may occur. In contrast to the phantom study, patient movement including respiration has to be compensated for in the clinical setting. KEY POINTS: • Commercially available electromagnetic navigation systems have the potential to improve the therapeutic range for CT guided percutaneous procedures by comparing the needle placement accuracy on the basis of planning CT data sets with different slice thickness. Citation Format: • Putzer D, Arco D, Schamberger B et al. Comparison of Two Electromagnetic Navigation Systems For CT-Guided Punctures: A Phantom Study. Fortschr Röntgenstr 2016; 188: 470 - 478.


Assuntos
Biópsia por Agulha/instrumentação , Ablação por Cateter/instrumentação , Fenômenos Eletromagnéticos , Biópsia Guiada por Imagem/instrumentação , Imagens de Fantasmas , Técnicas Estereotáxicas/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Conjuntos de Dados como Assunto , Precisão da Medição Dimensional , Desenho de Equipamento , Sistemas de Informação em Radiologia/instrumentação , Reprodutibilidade dos Testes , Software
10.
Rofo ; 188(3): 253-8, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26529265

RESUMO

UNLABELLED: Typically both breast and prostate cancer present as tissue with decreased elasticity. Palpation is the oldest technique of tumor detection in both organs and is based on this principle. Thus an operator can grade a palpable mass as suspicious for cancer. Strain elastography as modern ultrasound technique allows the visualization of tissue elasticity in a color coded elastogram and can be understood as technical finger. The following article shows similarities and differences of ultrasound strain elastography in the diagnosis of breast and prostate cancer. KEY POINTS: • In prostata cancer elastography, in breast cancer B-mode is the primary sonographic search modality. • The diagnostic value of the search modalities change with increasing age.• A cut-off value for a strain ratio is hard to obtain in the elastography of the prostata, because there is no stabile reference tissue in the prostata.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/fisiopatologia , Técnicas de Imagem por Elasticidade/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/fisiopatologia , Ultrassonografia Mamária/métodos , Módulo de Elasticidade , Feminino , Humanos , Aumento da Imagem/métodos , Masculino
11.
Ultraschall Med ; 37(4): 393-8, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25815457

RESUMO

PURPOSE: To evaluate the feasibility and effectiveness of US-guided sacroiliac joint injection in the treatment of sacroiliitis in children. MATERIALS AND METHODS: This study was approved by the institutional review board and informed oral and written consent was obtained from the patients and their parents. In 13 patients (7 females and 6 males), 9 - 16 years (mean +/- std 11.39 +/-1.98), 18 sacroiliac joint (SI joint) injections were performed under US guidance. All patients suffered from severe sacroiliitis. US scanning was performed using a linear-array transducer operating at 5 - 18 MHz. Rating of the patients pain using a 0 - 10 dolorimetry scale on a visual analog score (VAS) was recorded before, immediately after and 3 months after injection to monitor severity and therapeutic response. RESULTS: Injection could be performed in all patients without complication and showed good response immediately and 3 months after the injection with a decrease of the VAS (from mean +/- std 9.44 +/- 1.097 to 3.89 +/- 3.82, p < 0.001 and to 0.56 +/- 1.097, p < 0.05, respectively). CONCLUSION: US-guided SI joint injection was feasible in all children, relatively quick and easy to perform and appeared effective in the treatment of children with sacroiliitis.


Assuntos
Injeções Intra-Articulares/métodos , Articulação Sacroilíaca/efeitos dos fármacos , Sacroileíte/diagnóstico por imagem , Sacroileíte/tratamento farmacológico , Ultrassonografia de Intervenção , Adolescente , Criança , Estudos de Viabilidade , Feminino , Humanos , Masculino
12.
Rofo ; 187(6): 472-9, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25877992

RESUMO

PURPOSE: We compared the calibration of hepatic iron based on R2* relaxometry and liver biopsy with similar studies that have already been published to investigate the transferability of published calibration curves. MATERIALS AND METHODS: 17 patients with clinically suspected hepatic iron overload (HIO) were enrolled. All patients underwent liver biopsy and MRI of the liver using a multi-echo gradient echo sequence (TR = 200 ms; TE-initial 0.99 ms; Delta-TE 1.41 ms; 12 echos; flip-angle: 20 °). R2* parameter maps were analyzed using manually placed regions of interest and R2* values were correlated with liver iron concentration (LIC) obtained from liver biopsy. In addition, the results of our study were compared with 6 similar, already published studies. RESULTS: A linear relationship between R2* and LIC was found. Regression analysis yielded a correlation coefficient of 0.926, a slope of 0.024 (s mg/g) [95 % CI 0.013 - 0.024] and an intercept of 0.277 (mg/g) [95 % CI -0.328 - 2.49]. We found a significant correlation between the calibration curves obtained from our study in comparison to 3/6 similar studies. The other 3 studies used a different reference standard or sequence parameters which lead to a significant difference for slope, intercept or both in comparison to our data. CONCLUSION: Calibration curves from published studies that are based on a correlation of liver biopsy and R2* can be used for the estimation of liver iron concentration, although different scanning parameters and post-processing protocols were used. Low initial TEs might be a prerequisite for pooling data for liver iron quantification. KEY POINTS: • Calibration curves from different studies can be used for liver iron quantification• For that purpose calibration curves from published studies should be based on liver biopsy• Low initial TEs might be a prerequisite for pooling data for liver iron quantification.


Assuntos
Sobrecarga de Ferro/patologia , Hepatopatias/patologia , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/normas , Adulto , Idoso , Áustria , Biópsia , Calibragem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
13.
Ultraschall Med ; 36(6): 618-22, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25734410

RESUMO

PURPOSE: The objectives of this study were to compare sonoelastographic color findings of the perineural area between carpal tunnel syndrome patients and healthy volunteers, and to analyze elastographic findings in that area before and immediately after intracarpal tunnel injection in carpal tunnel syndrome patients. MATERIALS AND METHODS: We studied both hands of 15 healthy volunteers (7 men, 8 women; mean age: 60.1 years, range: 41 - 88 years) and 72 hands from 70 patients with symptomatic carpal tunnel syndrome (24 men, 46 women; mean age: 54.2 years, range: 24 - 83 years). Sonoelastographic color distribution was assessed in the perineural area between the median nerve and adjacent flexor tendons. The color elastograms were graded using the following system: Grade 1 as red (softest), grade 2 as yellow (soft), grade 3 as green (hard), grade 4 as blue (hardest). The patients were treated with corticosteroid injection and were reassessed with sonoelastography immediately after the injection. RESULTS: The median color grading in the perineural area of carpal tunnel syndrome patients was grade 3 (3.1 ±â€Š0.3, mean ±â€Š95 % Cl), which was stiffer than that of healthy volunteers (grade 1, 1.9 ±â€Š0.4) (p < 0.0001). Immediately after injection, the diffusion of the injected fluid was observed as having a softer appearance (grade 1, 1.4 ±â€Š0.2) (p < 0.0001). CONCLUSION: The perineural area surrounding the median nerve in carpal tunnel syndrome patients was stiffer than that in healthy volunteers. Diffusion of the injected fluid in the carpal tunnel was seen as a softer finding after injection in real time using sonoelastography.


Assuntos
Síndrome do Túnel Carpal/diagnóstico por imagem , Síndrome do Túnel Carpal/tratamento farmacológico , Técnicas de Imagem por Elasticidade/métodos , Aumento da Imagem/métodos , Nervo Mediano/efeitos dos fármacos , Nervo Mediano/diagnóstico por imagem , Mepivacaína/administração & dosagem , Triancinolona Acetonida/administração & dosagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Feminino , Humanos , Injeções Intra-Articulares , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valores de Referência
14.
Eur Radiol ; 25(5): 1356-65, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25501270

RESUMO

OBJECTIVES: To evaluate the automated two-point Dixon screening sequence for the detection and estimated quantification of hepatic iron and fat compared with standard sequences as a reference. METHODS: One hundred and two patients with suspected diffuse liver disease were included in this prospective study. The following MRI protocol was used: 3D-T1-weighted opposed- and in-phase gradient echo with two-point Dixon reconstruction and dual-ratio signal discrimination algorithm ("screening" sequence); fat-saturated, multi-gradient-echo sequence with 12 echoes; gradient-echo T1 FLASH opposed- and in-phase. Bland-Altman plots were generated and correlation coefficients were calculated to compare the sequences. RESULTS: The screening sequence diagnosed fat in 33, iron in 35 and a combination of both in 4 patients. Correlation between R2* values of the screening sequence and the standard relaxometry was excellent (r = 0.988). A slightly lower correlation (r = 0.978) was found between the fat fraction of the screening sequence and the standard sequence. Bland-Altman revealed systematically lower R2* values obtained from the screening sequence and higher fat fraction values obtained with the standard sequence with a rather high variability in agreement. CONCLUSIONS: The screening sequence is a promising method with fast diagnosis of the predominant liver disease. It is capable of estimating the amount of hepatic fat and iron comparable to standard methods. KEY POINTS: • MRI plays a major role in the clarification of diffuse liver disease. • The screening sequence was introduced for the assessment of diffuse liver disease. • It is a fast and automated algorithm for the evaluation of hepatic iron and fat. • It is capable of estimating the amount of hepatic fat and iron.


Assuntos
Fígado Gorduroso/diagnóstico , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Siderose/diagnóstico , Adulto , Idoso , Algoritmos , Feminino , Humanos , Imageamento Tridimensional , Fígado/patologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
15.
Biomed Res Int ; 2014: 180804, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24967334

RESUMO

Palpation of organs is one of the oldest clinical examination techniques, for instance, if you think of the palpation of the breast or the digital rectal examination of the prostate, where hard palpable regions are suspicious for cancer. This is the basic principle of real-time elastography, an ultrasound technique, which is able to visualise tissue elasticity. Since prostate cancer features an increased stiffness due to the higher cell and vessel density than the normal surrounding tissue, real-time elastography has been used for several years for prostate cancer detection. This review introduces the different techniques of ultrasound elastography and furthermore summarises its limitations and potentials.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Humanos , Masculino
16.
Radiologe ; 52(11): 994-1002, 2012 Nov.
Artigo em Alemão | MEDLINE | ID: mdl-23052963

RESUMO

CLINICAL/METHODICAL ISSUE: Osteoarthritis is the most common degenerative age-related joint disease leading to typical degradation of articular cartilage with severe pain and limitation of joint motion. STANDARD RADIOLOGICAL METHODS: Although knee radiographs are widely considered as the gold standard for the assessment of knee osteoarthritis in clinical and scientific settings they increasingly have significant limitations in situations when resolution and assessment of cartilage is required. METHODICAL INNOVATIONS: Analysis of osteoarthritis of the knee with conventional x-ray is associated with many technical limitations and is increasingly being replaced by high-quality assessment using magnetic resonance imaging (MRI) or sonography both in the clinical routine and scientific studies. PERFORMANCE: Novel imaging modalities such as MRI or ultrasound enable in vivo visualization of the quality of the cartilaginous structure and bone as well as all articular and periarticular tissue. Therefore, the limitations of radiographs in assessment of knee osteoarthritis could be overcome by these techniques. This review article aims to provide insights into the most important radiological features of knee osteoarthritis and systematic visualization with different imaging approaches. PRACTICAL RECOMMENDATIONS: The demographic development in western industrialized countries predicts an increase of ageing-related osteoarthritis of the knee for the next decades. A systematic radiological evaluation of patients with knee osteoarthritis includes the assessment of the periarticular soft tissue, cartilaginous thickness, cartilage volume, possible cartilage defects, the macromodular network of hyaline cartilage, bone marrow edema, menisci and articular ligaments. Modern imaging modalities, such as MRI and sonography allow the limitations of conventional radiography to be overcome and to visualize the knee structures in great detail to quantitatively assess the severity of knee osteoarthritis.


Assuntos
Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Osteoartrite do Joelho/diagnóstico , Tomografia Computadorizada por Raios X/métodos , Ultrassonografia/métodos , Humanos
17.
Pathologe ; 33(3): 254-61, 2012 May.
Artigo em Alemão | MEDLINE | ID: mdl-22383052

RESUMO

BACKGROUND: Focal nodular hyperplasia (FNH) is a benign hepatic tumor of unknown origin. It is only observed rarely in children (approximately 1-2% of all pediatric liver tumors). CASE REPORT: A 12-year-old boy who suffered from infectious mononucleosis with liver involvement and hepatomegaly underwent a sonographic scan of the liver at an external hospital 3 months after the infection disappeared which revealed a tumor of the left hepatic lobule. Subsequent further examination (abdominal CT and MRT scans) confirmed the diagnosis of a highly vascularized mass about 10 cm in diameter, suspicious for FNH. Due to the high vascularization no biopsy was performed. A preoperative angiographic coiling and complete surgical resection was carried out because of the size and morphologic uncertainty. The diagnosis of FNH was confirmed by histological examination. The annual sonographic examination at follow-up has been uneventful for a 4-year period. CONCLUSIONS: Due to the rarity the diagnosis of FNH in children can be difficult leading to differential diagnostic problems. Due to the risk of bleeding in larger size tumors a biopsy is a point of controversy. Complete resection and histopathological examination of FNHs in childhood is a mandatory therapeutic option, which may be indicated in large tumors or, as in the present case tumors of uncertain biological behaviour.


Assuntos
Hiperplasia Nodular Focal do Fígado/patologia , Criança , Diagnóstico Diferencial , Diagnóstico por Imagem , Hiperplasia Nodular Focal do Fígado/cirurgia , Hepatectomia , Hepatomegalia/patologia , Humanos , Mononucleose Infecciosa/patologia , Fígado/patologia , Masculino
18.
Radiologe ; 52(1): 56-62, 2012 Jan.
Artigo em Alemão | MEDLINE | ID: mdl-22249702

RESUMO

CLINICAL AND METHODOLOGICAL ISSUES: Ablative technologies allow local curative tumor treatment by thermal tissue damage. An important prerequisite is the coverage of all tumor cells. Tumor size is the most important limiting factor. STANDARD RADIOLOGICAL METHODS: The drawbacks of conventional computed tomography/ultrasound/magnetic resonance imaging (CT/US/MRI) guided radiofrequency ablation (RFA) are the absence of planning software, imprecise probe placement, imprecise control of probe placement and the ablation zone as well as the lack of reliability and reproducibility. METHODOLOGICAL INNOVATIONS: Stereotactic and robot-assisted systems allow planning of multiple probe positions based on CT/MRI and positron emission tomography (PET) planning data. The probes can be precisely placed according to the coordinates of the image datasets. PERFORMANCE: The 1 and 3 year survival rates after stereotactic RFA (SRFA) of cholangiocellular carcinoma were 91% and 70% respectively and the median overall survival was 60 months. After SRFA of 189 colorectal liver metastases in 63 patients there was no significant difference in local recurrence rates between tumors < 3 cm (17.7%), 3-5 cm (11.1%) and > 5 cm (17.4%). The median overall survival was 33.2 months and the 1, 3, and 5 year overall survival rates after SRFA in patients with resectable colorectal cancer were 92%, 66% and 48%, respectively. ACHIEVEMENTS: In our opinion the excellent and, to a large extent user-independent results justify the increased efforts in time and costs especially for the treatment of patients with large and irregular tumors. PRACTICAL RECOMMENDATIONS: Stereotaxy and robotics are valuable tools for effective tumor ablation especially of large tumors and are likely to gain in importance in the next few years.


Assuntos
Neoplasias/cirurgia , Robótica/instrumentação , Robótica/tendências , Técnicas Estereotáxicas/instrumentação , Técnicas Estereotáxicas/tendências , Cirurgia Assistida por Computador/instrumentação , Cirurgia Assistida por Computador/tendências , Humanos , Neoplasias/diagnóstico
19.
Rofo ; 184(2): 136-42, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22274855

RESUMO

PURPOSE: Reduction of the radiation exposure involved in image-guided craniofacial and skull base surgery is an important goal. The purpose was to evaluate the influence of low-dose protocols in modern multi-slice spiral computed tomography (MSCT) on target registration errors (TREs). MATERIALS AND METHODS: An anthropomorphic skull phantom with target markers at the craniofacial bone and the anterior skull base was scanned in Sensation Open (40-slice), LightSpeed VCT (64-slice) and Definition Flash (128-slice). Identical baseline protocols (BP) at 120  kV/100  mAs were compared to the following low-dose protocols (LD) in care dose/dose modulation: (LD-I) 100  kV/35ref. mAs, (LD-II) 80  kV/40 - 41ref. mAs, and (LD-III) 80  kV/15 - 17ref. mAs. CTDIvol and DLP were obtained. TREs using an optical navigation system were calculated for all scanners and protocols. Results were statistically analyzed in SPSS and compared for significant differences (p ≤ 0.05). RESULTS: CTDIvol for the Sensation Open/LightSpeed VCT/Definition Flash showed: (BP) 22.24 /32.48 /14.32 mGy; (LD-I) 4.61 /3.52 /1.62 mGy; (LD-II) 3.15 /2.01 /0.87 mGy; and (LD-III) na/0.76 /0.76 mGy. Differences between the BfS (Bundesamt für Strahlenschutz) reference CTDIvol of 9 mGy and the lowest CTDIvol were approximately 3-fold for Sensation Open, and 12-fold for the LightSpeed VCT and Definition Flash. A total of 33 registrations and 297 TRE measurements were performed. In all MSCT scanners, the TREs did not significantly differ between the low-dose and the baseline protocols. CONCLUSION: Low-dose protocols in modern MSCT provided substantial dose reductions without significant influence on TRE and should be strongly considered in image-guided surgery.


Assuntos
Osso Frontal/cirurgia , Tomografia Computadorizada Multidetectores/métodos , Neuronavegação/métodos , Doses de Radiação , Base do Crânio/cirurgia , Osso Temporal/cirurgia , Humanos , Posicionamento do Paciente , Imagens de Fantasmas , Lesões por Radiação/prevenção & controle , Intensificação de Imagem Radiográfica/métodos , Sensibilidade e Especificidade
20.
Vet Parasitol ; 185(2-4): 78-85, 2012 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-22105083

RESUMO

Data on the genotypes of Toxoplasma gondii circulating in wildlife are scarce. In the present study, foxes and rodents from two Federal States in Central or Eastern Germany were examined for T. gondii infections. Body fluids were collected at necropsy or fluids were obtained from frozen tissues of naturally exposed red foxes (Vulpes vulpes), voles (Microtus arvalis), shrews (Neomys anomalus) and a striped field mouse (Apodemus agrarius) and tested for T. gondii by serology. DNA isolated from tissues of seropositive foxes and all the rodents was examined by PCR. In the German Federal States of Brandenburg and Saxony-Anhalt 152/204 (74.5%) and 149/176 (84.7%) of foxes, respectively, but none of the rodents (0/72) had antibodies to T. gondii. Only 28/152 (18.4%) and 20/149 (13.4%) of seropositive foxes from Brandenburg and Saxony-Anhalt, respectively, but none of the rodents tested PCR-positive for T. gondii. The complete T. gondii genotype could be determined for twelve samples using nine PCR-restriction fragment length polymorphism (PCR-RFLP) markers (newSAG2, SAG3, BTUB, GRA6, c22-8, c29-2, PK1, L358 and Apico). In addition to T. gondii clonal type II (Apico II) and type II (Apico I), type III and T. gondii genotypes showing non-canonical allele patterns were observed in foxes. This suggests that, while T. gondii type II prevails in foxes, other genotypes circulate in wildlife. The population structure of T. gondii in Germany may be more diverse than previously thought.


Assuntos
Arvicolinae , Raposas , Roedores , Musaranhos , Toxoplasma/genética , Toxoplasmose Animal/epidemiologia , Animais , Feminino , Alemanha/epidemiologia , Masculino , Murinae , Doenças dos Roedores/epidemiologia , Doenças dos Roedores/parasitologia , Estudos Soroepidemiológicos , Toxoplasma/isolamento & purificação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...