Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ann Cardiol Angeiol (Paris) ; 70(5): 360-366, 2021 Nov.
Artigo em Francês | MEDLINE | ID: mdl-34452732

RESUMO

Aneurysm of the sinus of Valsalva is a rare cardiac condition, which could be either acquired or congenital. The most frequent complication is a rupture into right cavities or more rarely into left cavities or pericardium. Rupture could be either asymptomatic or poorly tolerated with hemodynamic instability, acute heart failure or sudden death. We report the case of a 24-year-old patient with no past medical history presenting with a partially ruptured sinus of Valsalva into the pericardium and in whom the initial diagnosis was idiopathic pericardial effusion; we describe diagnostic modalities and management.


Assuntos
Aneurisma Aórtico , Ruptura Aórtica , Derrame Pericárdico , Seio Aórtico , Adulto , Aneurisma Aórtico/diagnóstico , Aneurisma Aórtico/diagnóstico por imagem , Ruptura Aórtica/diagnóstico , Ruptura Aórtica/diagnóstico por imagem , Humanos , Derrame Pericárdico/etiologia , Pericárdio , Seio Aórtico/diagnóstico por imagem , Adulto Jovem
2.
Eur Heart J Cardiovasc Imaging ; 17(1): 41-50, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26188194

RESUMO

AIMS: To assess the value of cardiac magnetic resonance (CMR) using phase-contrast velocity mapping for paravalvular aortic regurgitation (PAR) quantification. METHODS AND RESULTS: All patients undergoing transcatheter aortic valve implantation (TAVI) in our centre between November 2012 and August 2013, without CMR-contraindication were included. PAR severity was assessed 5 days after TAVI using: transthoracic echocardiography (TTE) and CMR [regurgitant volume (RV), regurgitant fraction (RF)]. Aortic regurgitation (AR) index was obtained during TAVI. Thirty of 51 patients who underwent TAVI were included (COREVALVE, n = 10; or EDWARDS SAPIEN XT, n = 20). At TTE, PAR was mild in 22, moderate in 3, and severe in 5 patients. Reliable phase-contrast images were acquired at the sino-tubular junction for SAPIEN and at the tubular portion of the ascending aorta for COREVALVE. The reproducibility of CMR was high (coefficient of correlation = 0.99 for intra- and inter-operator variability). At CMR, RV, and RF were significantly (P < 0.0005) correlated with AR severity at TTE, with mean RF values at 9.2 ± 7.6% in mild, 20.3 ± 4.2% in moderate, and 46.8 ± 10.8% in severe PAR. A cut-off value of RF < 14% at CMR accurately discriminated mild from moderate/severe (sensitivity: 100%, specificity: 82%). The mean AR index was 29.4 ± 6 for mild and 13.8 ± 5 for moderate/severe PAR. Three patients had a RF > 14% and a low AR index <25 despite a mild PAR at TTE, suggesting an underestimation at TTE. CONCLUSION: CMR is a reproducible, accurate, and reliable method to assess PAR severity. CMR may allow correcting an underestimation at TTE when AR index is doubtful.


Assuntos
Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/cirurgia , Imagem Cinética por Ressonância Magnética , Substituição da Valva Aórtica Transcateter , Ecocardiografia/métodos , Humanos , Tomografia Computadorizada Multidetectores/métodos , Cuidados Pós-Operatórios , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/métodos
3.
J Cardiovasc Surg (Torino) ; 56(4): 513-8, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24284938

RESUMO

AIM: Circulatory failure following surgery for type A aortic dissection is frequent and associated with a high mortality rate. The intra-aortic balloon pump (IABP) is used to treat postcardiotomy cardiogenic shock but aortic dissection is traditionally a contraindication. In 10 patients we used IABP for severe cardiogenic shock following aortic dissection surgery, here we report on the short and midterm results. METHODS: From January 2000 to April 2008, among 151 patients with type A aortic dissection 10 received a postoperative IABP. False lumen extension was limited to the ascending aorta for 3 patients, reached the arch for 1 and the descending aorta for 6. RESULTS: The device was placed in the operative room (7 patients), intensive care unit (2) and preoperatively (1). IABP was introduced percutaneously except for one who required surgical placement. The mean duration of IABP therapy was 3.8 days. Four patients died, but no death was directly related to IABP. Improvement in hemodynamics allowed 8 patients to be weaned off IABP. None suffered extension of the dissection. Two patients developed IABP-related complications. Six required extrarenal purification. Among the survivors, one died of a stroke at 38 months, 2 recovered the same quality of life and 3 had neurological sequelae without loss of autonomy. CONCLUSION: IABP should only be used as a salvage option in cases of severe cardiogenic shock following type A aortic dissection. No patient suffered device-related aortic rupture or extension of the dissection. High mortality and morbidity underline the gravity of cardiogenic shock in this setting.


Assuntos
Aneurisma Aórtico/cirurgia , Dissecção Aórtica/cirurgia , Balão Intra-Aórtico , Choque Cardiogênico/terapia , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Dissecção Aórtica/diagnóstico , Dissecção Aórtica/mortalidade , Dissecção Aórtica/fisiopatologia , Aneurisma Aórtico/diagnóstico , Aneurisma Aórtico/mortalidade , Aneurisma Aórtico/fisiopatologia , Contraindicações , Bases de Dados Factuais , Feminino , Hemodinâmica , Humanos , Balão Intra-Aórtico/mortalidade , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Recuperação de Função Fisiológica , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/etiologia , Choque Cardiogênico/mortalidade , Choque Cardiogênico/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Procedimentos Cirúrgicos Vasculares/mortalidade
4.
J Cardiovasc Surg (Torino) ; 54(3): 373-81, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22820738

RESUMO

AIM: The goal of this study was to identify physical characteristics of primary intimal tears in patients arriving to the hospital alive with acute type A aortic dissection using 64-multislice computerized tomography (MSCT) in order to determine anatomic feasibility of endovascular stent-grafting (ESG) for future treatment. METHODS: Radiology database was screened for acute type A aortic dissection since the time of acquisition of the 64-slice CT scanner and cross-referenced with surgical database. Seventeen patients met inclusion criteria. Images were reviewed for number, location, and size of intimal tears and aortic dimensions. Potential obstacles for ESG were determined. RESULTS: Ascending aorta (29%) and sinotubular junction (29%) were the most frequent regions where intimal tears originated. Location of intimal tears in nearly 75% of patients was inappropriate for ESG, and 94% of patients did not have sufficient proximal or distal landing zone required for secure fixation. Only 71% of patients underwent surgical aortic dissection repair after imaging and 86% of entry tears detected on MSCT were confirmed on intraoperative documentation. Only one patient would have met all technical criteria for ESG using currently available devices. CONCLUSION: Location of intimal tear, aortic valve insufficiency, aortic diameter>38 mm are major factors limiting use of ESG for acute type A dissection. Available stents used to treat type B aortic dissection do not address anatomic constraints present in type A aortic dissection in the majority of cases, such that development of new devices would be required.


Assuntos
Aneurisma da Aorta Torácica/diagnóstico por imagem , Dissecção Aórtica/diagnóstico por imagem , Prótese Vascular , Procedimentos Endovasculares , Seleção de Pacientes , Stents , Tomografia Computadorizada por Raios X/métodos , Doença Aguda , Adulto , Idoso , Idoso de 80 Anos ou mais , Dissecção Aórtica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Resultado do Tratamento , Túnica Íntima/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...