Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nanomaterials (Basel) ; 9(2)2019 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-30813442

RESUMO

We report the fabrication of a novel fiber-optic sensor device, based on the use of a microsphere conformally coated with a thin layer of zinc oxide (ZnO) by atomic layer deposition (ALD), and its use as a refractive index sensor. The microsphere was prepared on the tip of a single-mode optical fiber, on which a conformal ZnO thin film of 200 nm was deposited using an ALD process based on diethyl zinc (DEZ) and water at 100 °C. The modified fiber-optic microsphere was examined using scanning electron microscopy and Raman spectroscopy. Theoretical modeling has been carried out to assess the structure performance, and the performed experimental measurements carried out confirmed the enhanced sensing abilities when the microsphere was coated with a ZnO layer. The fabricated refractive index sensor was operating in a reflective mode of a Fabry⁻Pérot configuration, using a low coherent measurement system. The application of the ALD ZnO coating enabled for a better measurement of the refractive index of samples in the range of the refractive index allowed by the optical fiber. The proof-of-concept results presented in this work open prospects for the sensing community and will promote the use of fiber-optic sensing technologies.

2.
J Biophotonics ; 12(4): e201800273, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30375195

RESUMO

In this paper, a spectroscopic method for determination of cyclosporine concentrations in biological fluids is presented. Blood plasma and hemoglobin solutions are chosen for the experiment. For various cyclosporine concentrations in blood plasma and hemoglobin, absorbance measurements in spectra range from 600 to 1100 nm are performed. The measurement results are analyzed by the use of a dedicated algorithm. The obtained data are characterized by a high coefficient of correlation R2 , which is equal to 0.9461 and 0.9808 for blood plasma and hemoglobin, respectively. The proposed method enables the selective detection of cyclosporine level and could be applied in medicine and laboratory diagnostics. The obtained result can be the base to build the point-of-care CsA level detection optical sensor.


Assuntos
Análise Química do Sangue/métodos , Ciclosporina/sangue , Fenômenos Ópticos , Humanos
3.
Sensors (Basel) ; 18(10)2018 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-30347649

RESUMO

The application of a Bluetooth skin resistance sensor in assisting people with Autism Spectrum Disorders (ASD), in their day-to-day work, is presented in this paper. The design and construction of the device are discussed. The authors have considered the best placement of the sensor, on the body, to gain the most accurate readings of user stress levels, under various conditions. Trial tests were performed on a group of sixteen people to verify the correct functioning of the device. Resistance levels were compared to those from the reference system. The placement of the sensor has also been determined, based on wearer convenience. With the Bluetooth Low Energy block, users can be notified immediately about their abnormal stress levels via a smartphone application. This can help people with ASD, and those who work with them, to facilitate stress control and make necessary adjustments to their work environment.


Assuntos
Transtorno do Espectro Autista/psicologia , Redes de Comunicação de Computadores/instrumentação , Pele/fisiopatologia , Tecnologia sem Fio/instrumentação , Local de Trabalho/psicologia , Humanos , Smartphone/instrumentação
4.
Sensors (Basel) ; 18(7)2018 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-29932121

RESUMO

In this paper, an investigation into detecting immunosuppressive medicine in aqueous solutions using a spectrometry-based technique is described. Using optical transmissive spectrometry, absorbance measurements in the spectra range from 250 nm to 1000 nm were carried out for different cyclosporine A (CsA) concentrations in aqueous solutions. The experiment was conducted for samples both with and without interferent substances—glucose and sodium chloride. Using a dedicated algorithm, the measured data was analyzed and a high correlation coefficient R² = 0.8647 was achieved. The experiment showed that the described technique allowed for the detection of various CsA concentration levels in a selective, label-free and simple way. This method could be used in medicine, veterinary medicine and laboratory diagnostics.

5.
Materials (Basel) ; 11(1)2018 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-29324715

RESUMO

In this work we present the fabrication and characterization of a diamond film which can be utilized in the construction of optical sensors for the investigation of biological samples. We produced a nitrogen-doped diamond (NDD) film using a microwave plasma enhanced chemical vapor deposition (MWPECVD) system. The NDD film was investigated with the use of scanning electron microscopy (SEM), atomic force microscopy (AFM) and Raman spectroscopy. The NDD film was used in the construction of the fiber optic sensor. This sensor is based on the Fabry-Pérot interferometer working in a reflective mode and the NDD film is utilized as a reflective layer of this interferometer. Application of the NDD film allowed us to obtain the sensor of hemoglobin concentration with linear work characteristics with a correlation coefficient (R²) equal to 0.988.

6.
Materials (Basel) ; 10(4)2017 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-28772710

RESUMO

This study reports the interactions of modified nanodiamond particles in vitro with human blood. Modifications performed on the nanodiamond particles include oxygenation with a chemical method and hydrogenation upon chemical vapor deposition (CVD) plasma treatment. Such nanodiamonds were later incubated in whole human blood for different time intervals, ranging from 5 min to 5 h. The morphology of red blood cells was assessed along with spectral measurements and determination of haemolysis. The results showed that no more than 3% of cells were affected by the nanodiamonds. Specific modifications of the nanodiamonds give us the possibility to obtain nanoparticles which are biocompatible with human blood. They can form a basis for the development of nanoscale biomarkers and parts of sensing systems and devices useful in biomedical environments.

7.
Sensors (Basel) ; 17(2)2017 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-28134855

RESUMO

Fiber-optic Fabry-Pérot interferometers (FPI) can be applied as optical sensors, and excellent measurement sensitivity can be obtained by fine-tuning the interferometer design. In this work, we evaluate the ability of selected dielectric thin films to optimize the reflectivity of the Fabry-Pérot cavity. The spectral reflectance and transmittance of dielectric films made of titanium dioxide (TiO2) and aluminum oxide (Al2O3) with thicknesses from 30 to 220 nm have been evaluated numerically and compared. TiO2 films were found to be the most promising candidates for the tuning of FPI reflectivity. In order to verify and illustrate the results of modelling, TiO2 films with the thickness of 80 nm have been deposited on the tip of a single-mode optical fiber by atomic layer deposition (ALD). The thickness, the structure, and the chemical properties of the films have been determined. The ability of the selected TiO2 films to modify the reflectivity of the Fabry-Pérot cavity, to provide protection of the fibers from aggressive environments, and to create multi-cavity interferometric sensors in FPI has then been studied. The presented sensor exhibits an ability to measure refractive index in the range close to that of silica glass fiber, where sensors without reflective films do not work, as was demonstrated by the measurement of the refractive index of benzene. This opens up the prospects of applying the investigated sensor in biosensing, which we confirmed by measuring the refractive index of hemoglobin and glucose.

8.
J Biomed Opt ; 22(1): 10502, 2017 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-28125156

RESUMO

This paper presents a newly developed dermatological laser (with a central wavelength 975 nm) for application in therapies requiring deep penetration of tissue, e.g., cutaneous (dermal) neurofibroma (von Recklinghausen disease) and hemangiomas. This laser can work either in pulses or continues wave mode. Laser radiation is transmitted toward the application region by optical fiber with a diameter of 0.6 mm. The compact design of the laser facilitates its transport and increases the comfort of use.


Assuntos
Hemangioma/cirurgia , Terapia a Laser/métodos , Neurofibroma/cirurgia , Neoplasias Cutâneas/cirurgia , Humanos , Lasers Semicondutores , Fibras Ópticas
9.
Biomed Opt Express ; 7(11): 4695-4701, 2016 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-27896008

RESUMO

Human tissue is one of the most complex optical media since it is turbid and nonhomogeneous. We suggest a new optical method for sensing physiological tissue state, based on the collection of the ejected light at all exit angles, to receive the full scattering profile. We built a unique set-up for noninvasive encircled measurement. We use a laser, a photodetector and finger tissues-mimicking phantoms presenting different optical properties. Our method reveals an isobaric point, which is independent of the optical properties. We compared the new finger tissues-like phantoms to others samples and found the linear dependence between the isobaric point's angle and the exact tissue geometry. These findings can be useful for biomedical applications such as non-invasive and simple diagnostic of the fingertip joint, ear lobe and pinched tissues.

10.
Biomed Opt Express ; 7(6): 2088-94, 2016 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-27375928

RESUMO

We present an alternative to the conventional approach, phantoms without scattering nanoparticles, where scattering is achieved by the material itself: spherical cavities trapped in a silicone matrix. We describe the properties and fabrication of novel optical phantoms based on a silicone elastomer polydimethylsiloxane (PDMS) and glycerol mixture. Optical properties (absorption coefficient µa , reduced scattering coefficient µs' , and anisotropy factor g) of the fabricated phantoms were retrieved from spectrophotometric measurements (in the 400-1100 nm wavelength range) using the inverse adding-doubling method. The internal structure of the phantoms was studied under a scanning electron microscope, and the chemical composition was assessed by Raman spectroscopy. Composition of the phantom material is reported along with the full characterization of the produced phantoms and ways to control their parameters.

11.
Sensors (Basel) ; 16(3)2016 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-27011188

RESUMO

In this paper we investigated the response of a fiber-optic Fabry-Pérot sensing interferometer with thin ZnO layers deposited on the end faces of the optical fibers forming the cavity. Standard telecommunication single-mode optical fiber (SMF-28) segments were used with the thin ZnO layers deposited by Atomic Layer Deposition (ALD). Measurements were performed with the interferometer illuminated by two broadband sources operating at 1300 nm and 1550 nm. Reflected interference signal was acquired by an optical spectrum analyzer while the length of the air cavity was varied. Thickness of the ZnO layers used in the experiments was 50 nm, 100 nm, and 200 nm. Uncoated SMF-28 fiber was also used as a reference. Based on the results of measurements, the thickness of the ZnO layers and the length of the cavity were selected in order to achieve good visibility. Following, the interferometer was used to determine the refractive index of selected liquids.

12.
J Biomed Opt ; 20(8): 85003, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26263414

RESUMO

Skin lesions are commonly treated using laser heating. However, the introduction of new devices into clinical practice requires evaluation of their performance. This study presents the application of optical phantoms for assessment of a newly developed 975-nm pulsed diode laser system for dermatological purposes. Such phantoms closely mimic the absorption and scattering of real human skin (although not precisely in relation to thermal conductivity and capacitance); thus, they can be used as substitutes for human skin for approximate evaluation of laser heating efficiency in an almost real environment. Thermographic imaging was applied to measure the spatial and temporal temperature distributions on the surface of laser-irradiated phantoms. The study yielded results of heating with regard to phantom thickness and absorption, as well as laser settings. The methodology developed can be used in practice for preclinical evaluations of laser treatment for dermatology.


Assuntos
Materiais Biomiméticos/síntese química , Materiais Biomiméticos/efeitos da radiação , Terapia a Laser/instrumentação , Imagens de Fantasmas , Dermatopatias/terapia , Temperatura Cutânea/efeitos da radiação , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Terapia a Laser/métodos , Luz , Dispositivos Ópticos , Dermatopatias/fisiopatologia
13.
J Biomed Opt ; 20(4): 045004, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25891198

RESUMO

We present the optical measurement techniques used in human skin phantom studies. Their accuracy and the sources of errors in microscopic parameters' estimation of the produced phantoms are described. We have produced optical phantoms for the purpose of simulating human skin tissue at the wavelength of 930 nm. Optical coherence tomography was used to measure the thickness and surface roughness and to detect the internal inhomogeneities. A more detailed study of phantom surface roughness was carried out with the optical profilometer. Reflectance, transmittance, and collimated transmittance of phantoms were measured using an integrating-sphere spectrometer setup. The scattering and absorption coefficients were calculated with the inverse adding-doubling method. The reduced scattering coefficient at 930 nm was found to be 1.57±0.14 mm(−1) and the absorption was 0.22±0.03 mm(−1) . The retrieved optical properties of phantoms are in agreement with the data found in the literature for real human tissues.


Assuntos
Materiais Biomiméticos/química , Imagens de Fantasmas , Refratometria/métodos , Fenômenos Fisiológicos da Pele , Pele/citologia , Tomografia de Coerência Óptica/métodos , Absorção de Radiação , Anisotropia , Desenho de Equipamento , Luz , Modelos Biológicos , Nefelometria e Turbidimetria/métodos , Doses de Radiação , Pele Artificial , Tomografia de Coerência Óptica/instrumentação
14.
Sensors (Basel) ; 14(4): 6965-76, 2014 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-24755518

RESUMO

In this paper, a low-coherence Fabry-Perot sensor with a spectrally measured signal processing response to the refractive index of liquids is presented. Optical fiber sensors are potentially capable of continuous measuring hematocrit levels in blood. Low-coherence Fabry-Perot interferometric sensors offer a robust solution, where information about the measurand is encoded in the full spectrum of light reflected from the sensing interferometer. The first step in the research on such sensor is the assessment of its performance under favorable conditions, i.e., using blood samples from healthy volunteers tested in vitro. Such an experiment was conducted using a sensor comprising a superluminescent diode source, an optical spectrum analyzer working as the detection setup and a sensing Fabry-Perot interferometer providing high interference contrast. The response of this sensor was recorded for several samples and compared with the reference laboratory method. The coefficient of determination (R²) for a linear relationship between the results given by both methods was 0.978 and the difference between these results was less than 1%. The presented results suggest that further research into the performance of the sensor is merited.


Assuntos
Hematócrito/instrumentação , Interferometria/instrumentação , Humanos , Padrões de Referência , Refratometria , Processamento de Sinais Assistido por Computador , Análise Espectral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...