Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Biomed Opt Express ; 3(4): 701-14, 2012 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-22574259

RESUMO

Blood flow in murine epicardial and intra-myocardial coronary arteries was measured in vivo with spectral domain optical Doppler tomography (SD-ODT). Videos at frame rates up to 180 fps were collected and processed to extract phase shifts associated with moving erythrocytes in the coronary arteries. Radial averaging centered on the vessel lumen provided spatial smoothing of phase noise in a single cross-sectional frame for instantaneous peak velocity measurement without distortion of the flow profile. Temporal averaging synchronized to the cardiac cycle (i.e., gating) was also performed to reduce phase noise, although resulting in lower flow profiles. The vessel angle with respect to incident imaging beam was measured with three-dimensional raster scans collected from the same region as the high speed cross-sectional scans. The variability in peak phase measurement was 10-15% from cycle to cycle on a single animal but larger for measurements among animals. The inter-subject variability is attributed to factors related to real physiological and anatomical differences, instrumentation variables, and measurement error. The measured peak instantaneous flow velocity in a ~40-µm diameter vessel was 23.5 mm/s (28 kHz Doppler phase shift). In addition to measurement of the flow velocity, we observed several dynamic features of the vessel and surrounding myocardium in the intensity and phase sequences, including asymmetric vessel deformation and rapid flow reversal immediately following maximum flow, in confirmation of known coronary artery flow dynamics. SD-ODT is an optical imaging tool that can provide in vivo measures of structural and functional information on cardiac function in small animals.

2.
Physiol Meas ; 32(6): 701-15, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21606560

RESUMO

This paper presents the design, construction and testing of a device to measure pressure-volume loops in the left ventricle of conscious, ambulatory rats. Pressure is measured with a standard sensor, but volume is derived from data collected from a tetrapolar electrode catheter using a novel admittance technique. There are two main advantages of the admittance technique to measure volume. First, the contribution from the adjacent muscle can be instantaneously removed. Second, the admittance technique incorporates the nonlinear relationship between the electric field generated by the catheter and the blood volume. A low power instrument weighing 27 g was designed, which takes pressure-volume loops every 2 min and runs for 24 h. Pressure-volume data are transmitted wirelessly to a base station. The device was first validated on 13 rats with an acute preparation with 2D echocardiography used to measure true volume. From an accuracy standpoint, the admittance technique is superior to both the conductance technique calibrated with hypertonic saline injections, and calibrated with cuvettes. The device was then tested on six rats with 24 h chronic preparation. Stability of animal preparation and careful calibration are important factors affecting the success of the device.


Assuntos
Volume Cardíaco/fisiologia , Estado de Consciência/fisiologia , Movimento/fisiologia , Telemetria/instrumentação , Telemetria/métodos , Pressão Ventricular/fisiologia , Animais , Condutividade Elétrica , Coração/fisiopatologia , Sistema de Condução Cardíaco/fisiologia , Ratos , Tórax/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA