Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biomed Res Int ; 2019: 6368958, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31828110

RESUMO

Nickel-titanium (NiTi) rotary files have enabled efficient root canal preparations that maintain the canal center with fewer aberrations compared to hand files. However, NiTi rotary files are susceptible to fracture, which can thereby compromise root canal treatment. Therefore, NiTi files have been developed to enhance fracture resistance by modifying design and thermal treatment. The objective of this study was to compare the torsional fatigue resistance and bending resistance of NiTi files manufactured from different alloys and treatments. ProTaper NEXT X2 (PTN; M-wire), V taper 2H (V2H; controlled memory wire), NRT (heat-treated), and One Shape (OS; conventional alloy) instruments of tip size #25 were compared. Torsional fatigue was evaluated by embedding the 3 mm tip of each instrument (N = 10/brand) in resin and the repetitive application of torsional stress (300 rpm, 1.0 N·cm) by an endodontic motor with autostop when the file fractured. The number of loading cycles to fracture was recorded and analyzed by Kruskal-Wallis and Mann-Whitney U tests with Bonferroni's correction. Bending resistance of the instruments was tested using a cantilever bending test to the 3 mm point from the tip (N = 10/brand). The stress was measured when deflection of 3 mm was subjected and statistically analyzed with a one-way analysis of variance and Tukey's honest significance difference test (α = 0.05). V2H withstood the highest number of load applications during torsional fatigue testing (p < 0.05), followed by NRT, PTN, and OS, where the differences between NRT and PTN (p=0.035) and between PTN and OS (p=0.143) were not statistically significant. V2H showed the lowest bending stiffness, followed by NRT, PTN, and OS (p < 0.001). Thermal treatment of NiTi wire resulted in improved mechanical properties, and controlled memory wire provided improved flexibility and torsional fatigue resistance.


Assuntos
Ligas/química , Ligas Dentárias/química , Teste de Materiais , Níquel/química , Estresse Mecânico , Titânio/química , Preparo de Canal Radicular
2.
Dent Mater J ; 38(1): 101-106, 2019 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-30381633

RESUMO

This study evaluates the effects of various agitation methods on the adhesive layer formation of a new HEMA-free universal dentin adhesive. The µTBS of the universal adhesive, G-Premio BOND in the self-etch mode was evaluated using three agitation methods [passive agitation (PA), active agitation (AA), ultrasonic agitation (UA)], with and without aging treatment. Two-way analysis of variance revealed that aging treatment was not a statistically significant factor. Tukey's HSD test showed significant differences based on the application method, UA>AA>PA. TEM images of the PA group revealed multiple water blisters in the adhesive layers; AA and UA groups presented significantly less or no blisters within the adhesive layers; thus, AA and UA groups exhibited better bonding performance for the HEMA-free universal adhesive. It is assumed that the entrap ped blisters can be reduced with the active application of dentin adhesive, and thus improving the bonding performance.


Assuntos
Resinas Compostas/química , Adesivos Dentinários/química , Humanos , Técnicas In Vitro , Teste de Materiais , Metacrilatos , Microscopia Eletrônica de Transmissão , Dente Serotino , Propriedades de Superfície , Resistência à Tração , Ultrassom , Vibração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...