Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Ergonomics ; 56(9): 1451-64, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23845083

RESUMO

This study measured the facial dimensions of Korean Air Force (KAF) pilots, to design a pilot oxygen mask, and compared them with those of Korean civilians and US Air Force (USAF) personnel. Twenty-two facial dimensions were measured for 278 KAF male pilots (KMP) and 58 KAF female pilots and cadets (KFP) using an anthropometer and a three-dimensional scanner. The KMP face measurements were found to be significantly larger (mean difference, [Formula: see text] = 0.7-26.5 mm) and less varied (ratio of SDs = 0.29-0.82) than those of Korean male civilians. The average face length, lip width and nasal root breadth of the KMP were significantly longer ([Formula: see text] = 4.7 mm), narrower ([Formula: see text] = -2.4 mm), and wider ([Formula: see text] = 5.2 mm), respectively, than those of USAF male personnel. Lastly, the KMP face measurements were significantly larger ([Formula: see text] = 1.8-26.1 mm) than those of the KFP. PRACTITIONER SUMMARY: The face measurements of KAF pilots were collected and compared with those of Korean civilians and USAF personnel. The distinct facial features of the populations identified in this study are applicable to custom design of an oxygen mask for prevention of excessive pressure and oxygen leakage.


Assuntos
Face/anatomia & histologia , Militares , Dispositivos de Proteção Respiratória , Adulto , Medicina Aeroespacial , Antropometria , Aviação , Desenho de Equipamento , Feminino , Humanos , Imageamento Tridimensional , Masculino , República da Coreia , Adulto Jovem
2.
Ergonomics ; 56(5): 879-87, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23510228

RESUMO

This study measured 21 anthropometric dimensions (ADs) of 94 Korean male helicopter pilots in their 20s to 40s and compared them with corresponding measurements of Korean male civilians and the US Army male personnel. The ADs and the sample size of the anthropometric survey were determined by a four-step process: (1) selection of ADs related to helicopter cockpit design, (2) evaluation of the importance of each AD, (3) calculation of required sample sizes for selected precision levels and (4) determination of an appropriate sample size by considering both the AD importance evaluation results and the sample size requirements. The anthropometric comparison reveals that the Korean helicopter pilots are larger (ratio of means = 1.01-1.08) and less dispersed (ratio of standard deviations = 0.71-0.93) than the Korean male civilians and that they are shorter in stature (0.99), have shorter upper limbs (0.89-0.96) and lower limbs (0.93-0.97), but are taller on sitting height, sitting eye height and acromial height (1.01-1.03), and less dispersed (0.68-0.97) than the US Army personnel. PRACTITIONER SUMMARY: The anthropometric characteristics of Korean male helicopter pilots were compared with those of Korean male civilians and US Army male personnel. The sample size determination process and the anthropometric comparison results presented in this study are useful to design an anthropometric survey and a helicopter cockpit layout, respectively.


Assuntos
Aeronaves , Antropometria , Povo Asiático , Militares , Adulto , Pesos e Medidas Corporais , Desenho de Equipamento , Humanos , Masculino , Pessoa de Meia-Idade , República da Coreia , Estados Unidos , Adulto Jovem
3.
Ergonomics ; 51(7): 1011-22, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-18568960

RESUMO

The study examined the impact of chemical protective (CP) clothing on the performance of lifesaving tasks in thermoneutral and cold conditions. Eleven males performed pre-exercise followed by lifesaving tasks wearing either field combat uniform at 21 degrees C (U) or CP clothing at 21 degrees C (CPN) and -5 degrees C (CPC). The tasks were ventilating a doll (VA) and connecting an intravenous line (IV). Mean skin temperature was significantly higher for CPN compared to U and CPC during pre-exercise, VA and IV. Changes in blood pressure were significantly greater with CP clothing than without during VA and IV. The number of breaths per min (in VA) and time needed for IV increased by 19% (p < 0.05) and 18%, respectively, for CPN compared to U. Due to the cold, the additional increment was 5% and 17%, respectively, for CPC. Wearing of CP clothing in thermoneutral or in cold conditions may not prevent but, especially in the cold, significantly impede the performance of basic medical tasks. The findings of this study showed that performing medical tasks while wearing nuclear, biological and chemical protective clothing is impaired due to significant changes in physiological strain. This suggests that realistic training in local conditions as well as in cold conditions is needed to realise the restrictions due to protective clothing.


Assuntos
Serviços Médicos de Emergência , Roupa de Proteção , Análise e Desempenho de Tarefas , Adulto , Temperatura Corporal , Temperatura Baixa , Frequência Cardíaca , Temperatura Alta , Humanos , Masculino , Consumo de Oxigênio , Temperatura Cutânea
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA