Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Arthroplasty ; 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38735552

RESUMO

BACKGROUND: We previously reported the mean 6-year outcomes of total hip arthroplasty (THA) using fourth-generation ceramic-on-ceramic (CoC) articulations. With extended observations, this study aimed to report the mean 12-year outcomes focusing on bearing-related complications of CoC THA. METHODS: We reviewed primary CoC THAs performed between May 2009 and April 2012 at a single institution. Of the 831 hips (739 patients), 716 hips (635 patients) that satisfied a minimum 10-year follow-up were included. The mean age at operation was 54 years (range, 16 to 83). The occurrence of bearing-specific complications, including ceramic fractures and noise generation, was evaluated. The mean follow-up duration was 12 years (range, 10 to 14). RESULTS: A total of 2 (0.3%) ceramic liner fractures occurred, as previously reported. No additional ceramic fractures were observed during the extended follow-up period. However, the cumulative incidence of audible noise increased from 6.4 (48 of 749) to 8.2% (59 of 716). Of the 59 hips with noise, 26 (44.1%) developed noise within 1 year, whereas 13 (22.0%) presented with noise more than 5 years after THA. The noise was described as clicking in 35 hips (4.9%) and as squeaking in 24 hips (3.4%). No revision surgeries were performed for noise, except in 2 cases of concomitant liner fractures. The implant survivorship free of any revision was 98.1% at 12 years. CONCLUSIONS: No additional ceramic fractures were identified in this extension study at a minimum follow-up of 10 years. However, the prevalence of articular noise has increased from 6.4 to 8.2% since the previous report. Possible late-onset noise should be considered when performing CoC THA in younger patients.

2.
J Arthroplasty ; 39(4): 1007-1012, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37852443

RESUMO

BACKGROUND: Although the modular sleeve concept for femoral implants has several advantages, studies reporting on greater than 20-year outcomes are limited. This study aimed to report the mean 23-year results of total hip arthroplasty (THA) using a modular stem with metaphyseal fixation sleeve. METHODS: This study reviewed primary THAs performed using a modular stem between October 1994 and April 1998. Of the 272 hips (221 patients) identified, 220 hips (177 patients) satisfying the minimum 20-year follow-up were included. The Harris Hip Score was used for clinical evaluation. Final hip radiographs were analyzed to evaluate the implant stability and the extent of femoral osteolysis. The mean follow-up duration was 23 years (range, 20 to 28). RESULTS: The mean Harris Hip Score improved from 38 points (range, 26 to 67) preoperatively to 90 points (range, 71 to 100) at the final follow-up (P < .001). Femoral osteolysis was observed in 146 hips (67.1%), but 145 were located proximal to the osseo-integrated sleeve. Overall, 4 femoral revisions were performed; 2 for chronic infection, one for aseptic loosening, and one for periprosthetic femoral fracture. Of the 19 (8.6%) periprosthetic femoral fractures, the most common type was Vancouver AG (13 hips). One (0.5%) asymptomatic distal stem fracture occurred, while no complications were identified at the stem-sleeve junction. Implant survivorship free of any femoral revision was 98.3% at 23 years. CONCLUSIONS: A THA using a modular stem with metaphyseal fixation sleeve demonstrated 98.3% stem survivorship with excellent clinical outcomes at a mean follow-up of 23 years in non-obese patients.


Assuntos
Artroplastia de Quadril , Fraturas do Fêmur , Prótese de Quadril , Osteólise , Fraturas Periprotéticas , Humanos , Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Osteólise/etiologia , Osteólise/cirurgia , Seguimentos , Reoperação/efeitos adversos , Falha de Prótese , Desenho de Prótese , Fraturas Periprotéticas/cirurgia , Fraturas Periprotéticas/complicações , Fraturas do Fêmur/cirurgia , Resultado do Tratamento , Estudos Retrospectivos
3.
J Arthroplasty ; 38(11): 2379-2385, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37271230

RESUMO

BACKGROUND: Periprosthetic femoral fractures (PFFs) remain a major concern following cementless total hip arthroplasty (THA). This study aimed to evaluate the association between different types of cementless tapered stems and the risk of postoperative PFF. METHODS: A retrospective review of primary THAs performed at a single center from January 2011 to December 2018 included 3,315 hips (2,326 patients). Cementless stems were classified according to their design. The incidence of PFF was compared between flat taper porous-coated stems (type A), rectangular taper grit-blasted stems (type B1), and quadrangular taper hydroxyapatite-coated stems (type B2). Multivariate regression analyses were performed to identify independent factors related to PFF. The mean follow-up duration was 61 months (range, 12 to 139). Overall, 45 (1.4%) postoperative PFFs occurred. RESULTS: The incidence of PFF was significantly higher in type B1 stems than in type A and type B2 stems (1.8 versus 0.7 versus 0.7%; P = .022). Additionally, more surgical treatments (1.7 versus 0.5 versus 0.7%; P = .013) and femoral revisions (1.2 versus 0.2 versus 0%; P = .004) were required for PFF in type B1 stems. After controlling for confounding variables, older age, diagnosis of hip fracture, and use of type B1 stems were significant factors associated with PFF. CONCLUSION: Type B1 rectangular taper stems were found to have higher risks for postoperative PFF and PFF requiring surgical management than type A and type B2 stems in THA. Femoral stem geometry should be considered when planning for cementless THA in elderly patients who have compromised bone quality.


Assuntos
Artroplastia de Quadril , Fraturas do Fêmur , Prótese de Quadril , Fraturas Periprotéticas , Humanos , Idoso , Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Fraturas do Fêmur/epidemiologia , Fraturas do Fêmur/etiologia , Fraturas do Fêmur/cirurgia , Fraturas Periprotéticas/epidemiologia , Fraturas Periprotéticas/etiologia , Fraturas Periprotéticas/cirurgia , Fêmur/cirurgia , Reoperação/efeitos adversos , Estudos Retrospectivos , Desenho de Prótese , Fatores de Risco
4.
J Arthroplasty ; 38(7): 1335-1341, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36709880

RESUMO

BACKGROUND: Cementing a new liner into a secure, well-positioned metallic shell can be a less-invasive strategy in revision total hip arthroplasty (THA). This study aimed to report the mean 14-year outcomes of cementing highly cross-linked polyethylene (XLPE) liners into well-fixed acetabular shells in revision THAs. METHODS: This study reviewed a single-surgeon series of cementing XLPE liners into well-fixed acetabular components. Of the 52 hips (51 patients) evaluated, 48 hips (47 patients) that satisfied a minimum follow-up of 10 years were included. The Harris Hip score was used for clinical evaluation. Final hip radiographs were used to determine the extent of acetabular osteolysis and stability of the components. The mean age at index operation was 53 years (range, 32 to 72). The mean follow-up duration was 14 years (range, 10 to 18). RESULTS: The mean Harris Hip score improved from 58 points (range, 23-81) preoperatively to 91 points (range, 45-100) at the final evaluation (P < .001). A total of 3 acetabular rerevisions were performed, all for aseptic loosening of the outer shell. One postoperative dislocation occurred, but it was successfully treated with a closed reduction. Final radiographs showed a significant reduction in acetabular osteolysis (P < .001). Implant survivorship free from any rerevision was 93.3% (95% confidence interval, 85.9-100%) at 14 years. CONCLUSION: Cementing an XLPE liner into a well-fixed acetabular shell in revision THA demonstrated excellent clinical and radiographic outcomes at a mean of 14 years postoperatively. This technique could be a safe and durable option in the absence of XLPE liners compatible with preimplanted shells.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Osteólise , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Artroplastia de Quadril/métodos , Polietileno , Osteólise/etiologia , Osteólise/cirurgia , Falha de Prótese , Acetábulo/cirurgia , Reoperação , Desenho de Prótese , Seguimentos
5.
J Arthroplasty ; 38(8): 1621-1627, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36720417

RESUMO

BACKGROUND: Iliopsoas tendinopathy (IPT) can cause persistent groin pain and lead to dissatisfaction after total hip arthroplasty (THA). This study aimed to report the characteristics, incidences, risk factors, and treatment outcomes of IPT after THA. METHODS: We reviewed primary THAs performed at a single institution between January 2012 and May 2018. Clinical and radiographic analyses were performed on 1,602 THAs (1,370 patients). Patient characteristics, component sizes, inclination and anteversion angles, and antero-inferior cup prominence (≥8 millimeters (mm)), were compared between the groups with and without IPT. Changes in teardrop to lesser trochanter distance were measured to estimate changes in leg length and horizontal offset caused by THA. Logistic regression models were used to identify the risk factors for IPT. IPT was identified in 53 hips (3.3%). RESULTS: Patients with IPT had greater leg lengthening (12.3 versus 9.3 mm; P = .001) and higher prevalence of antero-inferior cup prominence (5.7 versus 0.4%; P = .002). There was no significant difference in inclination, anteversion, and horizontal offset change between the two groups. In multivariate analyses, greater leg lengthening, prominent acetabular cup, women, and higher body mass index were associated with IPT. All patients reported improvement in groin pain after arthroscopic tenotomy, while 35.7% with nonoperative management reported improvement (P < .001). CONCLUSIONS: Symptomatic IPT occurred in 53 (3.3%) of the 1,602 primary THAs. Our findings suggest that leg lengthening as well as prominent acetabular cup in THAs can be associated with the development of IPT. Arthroscopic tenotomy was effective in relieving groin pain caused by IPT.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Tendinopatia , Humanos , Feminino , Artroplastia de Quadril/efeitos adversos , Incidência , Acetábulo/cirurgia , Tendinopatia/diagnóstico por imagem , Tendinopatia/epidemiologia , Tendinopatia/etiologia , Fatores de Risco , Dor/cirurgia , Prótese de Quadril/efeitos adversos , Estudos Retrospectivos
6.
Arch Orthop Trauma Surg ; 136(10): 1381-5, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27450062

RESUMO

The treatment of a large segmental defect of over 6 cm in a long bone is a challenging procedure. Treatment options include cancellous bone graft (e.g., the Masquelet technique), vascularized fibular graft (VFG), and internal bone transport (IBT) with an external fixator. These methods may be performed with intramedullary (IM) nailing or plate fixation to enhance stability or to lessen the time of external fixation. Each method has its own advantages and limitations. This study aimed to describe the advantages of additional plate augmentation and autologous bone grafting after IM nail implantation. Three patients with large segmental femoral bone defects were treated with IM nail implantation; then, one- or two-stage autologous iliac bone grafting with additional plate augmentation was performed. All patients achieved bony union without metal failure. We describe a technique involving additional plate augmentation and autologous iliac bone grafting for treating large femoral defects after restoring the length of the femur using an IM nail implantation and an external fixator.


Assuntos
Placas Ósseas , Transplante Ósseo/métodos , Fraturas do Fêmur/cirurgia , Fixação Intramedular de Fraturas/métodos , Ílio/transplante , Adulto , Fixação Intramedular de Fraturas/instrumentação , Humanos , Masculino , Pessoa de Meia-Idade , Transplante Autólogo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...