Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Chempluschem ; : e202400096, 2024 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-38523300

RESUMO

A newly designed heterogenized catalyst that incorporates silver(I) ions with 2-(dicyclohexylphosphaneyl)acetaldehyde (PCy2 aldehyde) into amino-functionalized chromium(III) terephthalate is developed. Silver(I) ions were robustly immobilized on the amino-functionalized chromium(III) terephthalate, which contains an imine bond formed by the reaction with PCy2 aldehyde. The Ag(I) ion is coordinated with the phosphine in the imine group to create MIL-101-AP(Ag). Characterizations were carefully carried out according to the synthetic steps. The catalytic performance of MIL-101-AP(Ag) was evaluated through the C-H carboxylation of thiophene-2-carbonitrile, achieving a 10 % yield with a turnover number of 1.0. The recyclability of the MIL-101-AP(Ag) catalyst was successfully demonstrated with five cycle, with no loss in activity and selectivity observed. This approach, which involves the formation of an imine bond to facilitate silver loading with phosphine on amino-functionalized MIL-101(Cr), exhibits significant potential for both CO2 fixation and C-H carboxylation, thereby highlighting the modified material's promise as a sustainable catalyst.

2.
ACS Appl Mater Interfaces ; 16(1): 1342-1350, 2024 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-38116929

RESUMO

In this study, three nitrogen-containing aluminum-based metal-organic frameworks (Al-MOFs), namely, CAU-10pydc, MOF-303, and KMF-1, were investigated for the efficient separation of a C2H2/CO2 gas mixture. Among these three Al-MOFs, KMF-1 demonstrated the highest selectivity for C2H2/CO2 separation (6.31), primarily owing to its superior C2H2 uptake (7.90 mmol g-1) and lower CO2 uptake (2.82 mmol g-1) compared to that of the other two Al-MOFs. Dynamic breakthrough experiments, using an equimolar binary C2H2/CO2 gas mixture, demonstrated that KMF-1 achieved the highest separation performance. It yielded 3.42 mmol g-1 of high-purity C2H2 (>99.95%) through a straightforward desorption process under He purging at 298 K and 1 bar. To gain insights into the distinctive characteristics of the pore surfaces of structurally similar CAU-10pydc and KMF-1, we conducted computational simulations using canonical Monte Carlo and dispersion-corrected density functional theory methods. These simulations revealed that the secondary amine (C2N-H) groups in KMF-1 played a more significant role in differentiating between C2H2 and CO2 compared to that of the N atoms in CAU-10pydc and MOF-303. Consequently, KMF-1 emerged as a promising adsorbent for the separation of high-purity C2H2 from binary C2H2/CO2 gas mixtures.

3.
Sensors (Basel) ; 23(13)2023 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-37447942

RESUMO

Cracks have a primary effect on the failure of a structure. Therefore, the development of crack sensors with high accuracy and resolution and cracks detection method are important. In this study, the crack sensors were fabricated, and the crack locations were detected with the electrical signal of the crack sensor. First, a metal grid-type micro-crack sensor based on silver was fabricated. The sensor is made with electrohydrodynamics (EHD) inkjet printing technology, which is well known as the next generation of printed electronics technology. Optimal printing conditions were established through experiments, and a grid sensor was obtained. After that, single cracks and multiple cracks were simulated on the sensor, and electrical signals generated from the sensor were measured. The measured electrical signal tracked the location of the cracks in three steps: simple cross-calculation, interpolation, and modified P-SPICE. It was confirmed that cracks could be effectively found and displayed using the method presented in this paper.


Assuntos
Sistemas Computacionais , Eletricidade , Eletrônica , Prata , Tecnologia
4.
J Nanosci Nanotechnol ; 21(7): 3773-3778, 2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-33715690

RESUMO

This paper proposes a new mechanism for detecting microscopic damage of structures based on imitating the sensory organs of spiders. Therefore, it is essential to manufacture sensors that can react sensitively to the micro deformations of structures. Numerous cracks were intentionally generated to improve the sensitivity of the proposed sensor, and an increase in the gap of the crack was observed by scanning electron microscopy (SEM) observation. Electrohydrodynamic technology is used to detect deformations in a structure of depositing Ag nano paste on a polyethylene terephtha-late (PET) substrate. Ag nano lines are also observed by SEM images. The sensor is constructed as a grid structure, by forming layers patterned horizontally and vertically. An impact tester is used to verify the mechanism for structural health monitoring using the developed sensor. The resistance changes of the sensors are applied to estimate the structure's damaged location. The intersections of the lines with varying resistance can be used to accurately detect crack initiation. The proposed mechanism is a powerful methodology for estimating and detecting microscopic deformations and damage to structures.


Assuntos
Biomimética , Microscopia Eletrônica de Varredura
5.
J Nanosci Nanotechnol ; 21(9): 4877-4880, 2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-33691882

RESUMO

This study aimed to evaluate the soundness of solid-state welded steels. STS 430F alloy with a rod type was selected as experimental material, and the friction welding was conducted at a rotation speed of 2,000 RPM and upset length of 3 mm. The application of friction welding on STS 430F rods led to significant grain refinement in the welded zone (1.3 µm) compared to that observed in the base material (16.8 µm). The refined grains in the welds contributed to the development of the mechanical properties. In particular, the Vickers microhardness was increased by approximately 25% compared to the base material, and the fracture at the tensile specimen of the welds occurred at the base material zone and not in the welded zone, which suggests a soundly welded state on the STS 430F rods.

6.
J Nanosci Nanotechnol ; 18(3): 2252-2257, 2018 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-29448756

RESUMO

Brittle failure of high toughness steel structures tends to occur after ductile crack initiation/propagation. Damages to steel structures were reported in the Hanshin Great Earthquake. Several brittle failures were observed in beam-to-column connection zones with geometrical discontinuity. It is widely known that triaxial stresses accelerate the ductile fracture of steels. The study examined the effects of geometrical heterogeneity and strength mismatches (both of which elevate plastic constraints due to heterogeneous plastic straining) and loading rate on critical conditions initiating ductile fracture. This involved applying the two-parameter criterion (involving equivalent plastic strain and stress triaxiality) to estimate ductile cracking for strength mismatched specimens under static and dynamic tensile loading conditions. Ductile crack initiation testing was conducted under static and dynamic loading conditions using circumferentially notched specimens (Charpy type) with/without strength mismatches. The results indicated that the condition for ductile crack initiation using the two parameter criterion was a transferable criterion to evaluate ductile crack initiation independent of the existence of strength mismatches and loading rates.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...