Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-764178

RESUMO

Cavernous hemangioma of the gallbladder is an extremely rare benign tumor. The tumor has only a few cases being reported in literature. However, to the best of our knowledge, no reports focusing on the MRI findings of cavernous hemangioma of the gallbladder have been published. This study reports a case of gallbladder hemangioma with pathologic and radiologic reviews, including MRI findings.


Assuntos
Vesícula Biliar , Hemangioma , Hemangioma Cavernoso , Imageamento por Ressonância Magnética
2.
Korean Journal of Radiology ; : 1313-1333, 2019.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-760306

RESUMO

Cardiac magnetic resonance (CMR) imaging is widely used in many areas of cardiovascular disease assessment. This is a practical, standard CMR protocol for beginners that is designed to be easy to follow and implement. This protocol guideline is based on previously reported CMR guidelines and includes sequence terminology used by vendors, essential MR physics, imaging planes, field strength considerations, MRI-conditional devices, drugs for stress tests, various CMR modules, and disease/symptom-based protocols based on a survey of cardiologists and various appropriate-use criteria. It will be of considerable help in planning and implementing tests. In addressing CMR usage and creating this protocol guideline, we particularly tried to include useful tips to overcome various practical issues and improve CMR imaging. We hope that this document will continue to standardize and simplify a patient-based approach to clinical CMR and contribute to the promotion of public health.


Assuntos
Doenças Cardiovasculares , Comércio , Teste de Esforço , Coração , Esperança , Imageamento por Ressonância Magnética , Saúde Pública
3.
Korean Journal of Radiology ; : 1477-1490, 2019.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-760261

RESUMO

Cardiovascular magnetic resonance imaging (CMR) is expected to be increasingly used in Korea due to technological advances and the expanded national insurance coverage of CMR assessments. For improved patient care, proper acquisition of CMR images as well as their accurate interpretation by well-trained personnel are equally important. In response to the increased demand for CMR, the Korean Society of Cardiovascular Imaging (KOSCI) has issued interpretation guidelines in conjunction with the Korean Society of Radiology. KOSCI has also created a formal Committee on CMR guidelines to create updated practices. The members of this committee review previously published interpretation guidelines and discuss the patterns of CMR use in Korea.


Assuntos
Angiografia , Coração , Cobertura do Seguro , Coreia (Geográfico) , Imageamento por Ressonância Magnética , Assistência ao Paciente
4.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-785884

RESUMO

Cardiac magnetic resonance (CMR) imaging is widely used in many areas of cardiovascular disease assessment. This is a practical, standard CMR protocol for beginners that is designed to be easy to follow and implement. This protocol guideline is based on previously reported CMR guidelines and includes sequence terminology used by vendors, essential MR physics, imaging planes, field strength considerations, MRI-conditional devices, drugs for stress tests, various CMR modules, and disease/symptom-based protocols based on a survey of cardiologists and various appropriate-use criteria. It will be of considerable help in planning and implementing tests. In addressing CMR usage and creating this protocol guideline, we particularly tried to include useful tips to overcome various practical issues and improve CMR imaging. We hope that this document will continue to standardize and simplify a patient-based approach to clinical CMR and contribute to the promotion of public health.


Assuntos
Doenças Cardiovasculares , Comércio , Teste de Esforço , Coração , Esperança , Imageamento por Ressonância Magnética , Saúde Pública
5.
Korean Journal of Radiology ; : 1562-1582, 2019.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-786373

RESUMO

This document is the third part of the guidelines for the protocol, the interpretation and post-processing of cardiac magnetic resonance (CMR) studies. These consensus recommendations have been developed by the Consensus Committee of the Korean Society of Cardiovascular Imaging to standardize the requirements for image interpretation and post-processing of CMR. This third part of the recommendations describes tissue characterization modules, including perfusion, late gadolinium enhancement, and T1- and T2 mapping. Additionally, this document provides guidance for visual and quantitative assessment consisting of “What-to-See,” “How-To,” and common pitfalls for the analysis of each module. The Consensus Committee hopes that this document will contribute to the standardization of image interpretation and post-processing of CMR studies.


Assuntos
Consenso , Gadolínio , Esperança , Imageamento por Ressonância Magnética , Perfusão
6.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-715440

RESUMO

OBJECTIVE: To determine if measurement of the diameter of the solid component in subsolid nodules (SSNs) on low-dose unenhanced chest computed tomography (CT) is as accurate as on standard-dose enhanced CT in prediction of pathological size of invasive component of lung adenocarcinoma. MATERIALS AND METHODS: From February 2012 to October 2015, 114 SSNs were identified in 105 patients that underwent low-dose unenhanced and standard-dose enhanced CT pre-operatively. Three radiologists independently measured the largest diameter of the solid component. Intraclass correlation coefficients (ICCs) were used to assess inter-reader agreement. We estimated measurement differences between the size of solid component and that of invasive component. We measured diagnostic accuracy of the prediction of invasive adenocarcinoma using a size criterion of a solid component ≥ 6 mm, and compared them using a generalized linear mixed model. RESULTS: Inter-reader agreement was excellent (ICC, 0.84.0.89). The mean ± standard deviation of absolute measurement differences between the solid component and invasive component was 4 ± 4 mm in low-dose unenhanced CT and 5 ± 4 mm in standard-dose enhanced CT. Diagnostic accuracy was 81.3% (95% confidence interval, 76.7.85.3%) in low-dose unenhanced CT and 76.6% (71.8.81.0%) in standard-dose enhanced CT, with no statistically significant difference (p = 0.130). CONCLUSION: Measurement of the diameter of the solid component of SSNs on low-dose unenhanced chest CT was as accurate as on standard-dose enhanced CT for predicting the invasive component. Thus, low-dose unenhanced CT may be used safely in the evaluation of patients with SSNs.


Assuntos
Humanos , Adenocarcinoma , Pulmão , Tórax , Tomografia Computadorizada por Raios X
7.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-740126

RESUMO

PURPOSE: This study was designed to optimize the flip angle (FA) and scan timing of the hepatobiliary phase (HBP) using the 3D T1-weighted, gradient-echo (GRE) imaging with controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) technique on gadoxetic acid-enhanced 3T liver MR imaging. MATERIALS AND METHODS: Sixty-two patients who underwent gadoxetic acid-enhanced 3T liver MR imaging were included in this study. Four 3D T1-weighted GRE imaging studies using the CAIPIRINHA technique and FAs of 9° and 13° were acquired during HBP at 15 and 20 min after intravenous injection of gadoxetic acid. Two abdominal radiologists, who were blinded to the FA and the timing of image acquisition, assessed the sharpness of liver edge, hepatic vessel clarity, lesion conspicuity, artifact severity, and overall image quality using a five-point scale. Quantitative analysis was performed by another radiologist to estimate the relative liver enhancement (RLE) and the signal-to-noise ratio (SNR). Statistical analyses were performed using the Wilcoxon signed rank test and one-way analysis of variance. RESULTS: The scores of the HBP with an FA of 13° during the same delayed time were significantly higher than those of the HBP with an FA of 9° in all the assessment items (P < 0.01). In terms of the delay time, images at the same FA obtained with a 20-min-HBP showed better quality than those obtained with a 15-min-HBP. There was no significant difference in qualitative scores between the 20-min-HBP and the 15-min-HBP images in the non-liver cirrhosis (LC) group except for the hepatic vessel clarity score with 9° FA. In the quantitative analysis, a statistically significant difference was found in the degree of RLE in the four HBP images (P = 0.012). However, in the subgroup analysis, no significant difference in RLE was found in the four HBP images in either the LC or the non-LC groups. The SNR did not differ significantly in the four HBP images. In the subgroup analysis, 20-min-HBP imaging with a 13° FA showed the highest SNR value in the LC-group, whereas 15-min-HBP imaging with a 13° FA showed the best value of SNR in the non-LC group. CONCLUSION: The use of a moderately high FA improves the image quality and lesion conspicuity on 3D, T1-weighted GRE imaging using the CAIPIRINHA technique on gadoxetic acid, 3T liver MR imaging. In patients with normal liver function, the 15-min-HBP with a 13° FA represents a feasible option without a significant decrease in image quality.


Assuntos
Humanos , Aceleração , Artefatos , Suspensão da Respiração , Meios de Contraste , Fibrose , Gadolínio DTPA , Injeções Intravenosas , Fígado , Imageamento por Ressonância Magnética , Razão Sinal-Ruído
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...