Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 92(3): 033309, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33820015

RESUMO

Characteristics and performance of a time of flight (TOF) spectrometer developed for performing fission mass distribution studies are presented. The spectrometer contains two TOF arms based on multi-wire proportional counters (MWPCs). Each arm has two MWPCs to form a start-stop detection system for TOF measurements. The start detector has an active area of 4 × 4 cm2. The stop detector is a two-dimensional position sensitive MWPC with an active area of 16 × 11 cm2. Salient features of the MWPCs are the use of reduced sub-millimeter wire pitches of 0.635 and 0.317 mm in the electrodes along with the use of gold plated tungsten wires of diameters 10 and 20 µm. A delay line for position electrodes is prepared using chip inductors and capacitors. Ten different configurations of MWPC were investigated for the start detector, which involved the use of three and four electrode geometries, use of different wire pitches, and use of aluminized mylar for timing electrodes. Performance results close to micro-channel plate detectors have been observed with some designs of MWPC, displaying rise times better than 2 ns with an estimated inherent time resolution of ∼100 ps FWHM. A position resolution of ∼1 mm (FWHM) has been observed. Design features of the MWPCs and their test performance results are described in this article.

2.
Phys Rev Lett ; 110(16): 163203, 2013 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-23821777

RESUMO

We have measured the stopping powers and straggling of fast, highly ionized atoms passing through thin bilayer targets made up of metals and insulators. We were surprised to find that the energy losses as well as the straggling depend on the ordering of the target and have small but significantly different values on bilayer reversal. We ascribe this newly found difference in energy loss to the surface energy loss field effect due to the differing surface wake fields as the beam exits the target in the two cases. This finding is validated with experiments using several different projectiles, velocities, and bilayer targets. Both partners of the diatomic molecular ions also display similar results. A comparison of the energy loss results with those of previous theoretical predictions for the surface wake potential for fast ions in solids supports the existence of a self-wake.

3.
Rev Sci Instrum ; 80(12): 123502, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20059140

RESUMO

Two large area multistep position sensitive (two dimensional) multiwire proportional counters have been developed for experiments involving study of fission dynamics using general purpose scattering chamber facility at IUAC. Both detectors have an active area of 20x10 cm(2) and provide position signals in horizontal (X) and vertical (Y) planes, timing signal for time of flight measurements and energy signal giving the differential energy loss in the active volume. The design features are optimized for the detection of low energy heavy ions at very low gas pressures. Special care was taken in setting up the readout electronics, constant fraction discriminators for position signals in particular, to get optimum position and timing resolutions along with high count rate handling capability of low energy heavy ions. A custom made charge sensitive preamplifier, having lower gain and shorter decay time, has been developed for extracting the differential energy loss signal. The position and time resolutions of the detectors were determined to be 1.1 mm full width at half maximum (FWHM) and 1.7 ns FWHM, respectively. The detector could handle heavy ion count rates exceeding 20 kHz without any breakdown. Time of flight signal in combination with differential energy loss signal gives a clean separation of fission fragments from projectile and target like particles. The timing and position signals of the detectors are used for fission coincidence measurements and subsequent extraction of their mass, angular, and total kinetic energy distributions. This article describes systematic study of these fission counters in terms of efficiency, time resolution, count rate handling capability, position resolution, and the readout electronics. The detector has been operated with both five electrode geometry and four electrode geometry, and a comparison has been made in their performances.