Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Vis Exp ; (187)2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-36121270

RESUMO

During the last decade, optogenetics has become an essential tool for the investigation of neural signaling due to its unique capability of selective neural modulation or monitoring. As specific types of neuronal cells can be genetically modified to express opsin proteins, optogenetics enables optical stimulation or inhibition of the selected neurons. There have been several technological advances in the optical system for optogenetics. Recently, it was proposed to combine the optical waveguide for light delivery with electrophysiological recording to simultaneously monitor the neural responses to optogenetic stimulation or inhibition. In this study, an implantable optrode array (2x2 optical fibers) was developed with embedded multichannel electrodes. A light-emitting diode (LED) was employed as a light source, and a microfabricated microlens array was integrated to provide sufficient light power at the tip of the optical fibers. The optrode array system comprises the disposable part and the reusable part. The disposable part has optical fibers and electrodes, while the reusable part has the LED and electronic circuitry for light control and neural signal processing. The novel design of the implantable optrode array system is introduced in the accompanying video in addition to the procedure of the optrode implantation surgery, optogenetic light stimulation, and the electrophysiological neural recording. The results of in vivo experiments successfully showed time-locked neural spikes evoked by the light stimuli from hippocampal excitatory neurons of mice.


Assuntos
Dispositivos Ópticos , Optogenética , Animais , Desenho de Equipamento , Camundongos , Neurônios/fisiologia , Opsinas , Optogenética/métodos
2.
J Neural Eng ; 19(4)2022 07 20.
Artigo em Inglês | MEDLINE | ID: mdl-35797969

RESUMO

Objective. This paper presents a conventional light emitting diode (LED) and polymer waveguide coupled silicon optrode array.Approach. Unique lens design at the waveguide inlet enables a high light coupling efficiency with a single LED light source, and provides small power consumption compatible with a wireless optogenetic neuromodulation system. To increase the light intensity at the waveguide tip, a lensed waveguide is fabricated with epoxy-based photoresist SU-8, which has a plano-convex lens shape at the waveguide inlet to focus the light in the horizontal direction. In addition, a cylindrical lens is assembled in front of the waveguide inlet to focus the source light in the vertical direction.Main results. The glass cylindrical lens and SU-8 plano-convex lens increased the light coupling efficiency by 6.7 dB and 6.6 dB, respectively. The fabricated 1 × 4 array of optrodes is assembled with a single LED with 465 nm wavelength, which produces a light intensity of approximately 2.7 mW mm-2at the SU-8 waveguide outlet when 50 mA input current is applied to the LED. Each optrode has four recording electrodes at the SU-8 waveguide outlet. The average impedance of the iridium oxide (IrOx) electroplated recording electrodes is 43.6 kΩ.Significance.In-vivoexperiment at the hippocampus region CA1 and CA2 demonstrated the capability of optical stimulation and neural signal recording through the LED and SU-8 waveguide coupled silicon optrode array.


Assuntos
Optogenética , Silício , Córtex Cerebral , Luz , Optogenética/métodos , Estimulação Luminosa
3.
Micromachines (Basel) ; 12(6)2021 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-34205473

RESUMO

During the last decade, optogenetics has become an essential tool for neuroscience research due to its unrivaled feature of cell-type-specific neuromodulation. There have been several technological advances in light delivery devices. Among them, the combination of optogenetics and electrophysiology provides an opportunity for facilitating optogenetic approaches. In this study, a novel design of an optrode array was proposed for realizing optical modulation and electrophysiological recording. A 4 × 4 optrode array and five-channel recording electrodes were assembled as a disposable part, while a reusable part comprised an LED (light-emitting diode) source and a power line. After the characterization of the intensity of the light delivered at the fiber tips, in vivo animal experiment was performed with transgenic mice expressing channelrhodopsin, showing the effectiveness of optical activation and neural recording.

4.
Opt Express ; 28(21): 31272-31286, 2020 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-33115104

RESUMO

We present the design optimization, fabrication, and analysis of an electromagnetic biaxial scanning micromirror with 6.4 mm-diameter. The scanner is composed of a micromirror supported by two concentric gimbal structures with unique single turn coil. A cylindrical permanent magnet assembly is placed under the micromirror to provide a radial magnetic field for actuation. Lumped element model parameters and magnetic circuit have been optimized to maximize the driving torque. Fabricated micromirror has been actuated at 300 Hz and 1,010 Hz and maximum optical scan angle of 25.6° and 35.3° have been obtained for the vertical and horizontal scans, respectively. Crosstalk during the actuation has been analyzed, and improved models have been proposed to reduce the crosstalk.

5.
Sci Technol Adv Mater ; 20(1): 124-143, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30815044

RESUMO

In this paper, we look into the fundamental mechanism to retrieve the power from physical vibrations by using microelectromechanical systems (MEMS) energy harvesters. An analytical model is presented for the velocity-damped resonant generator (VDRG) that delivers electrical power through the power enhancement mechanism using the mechanical resonance of a suspended mass. Deliverable power is also analytically discussed with respect to the theoretical limit, and a view to understand the VDRG behaviors is presented in association with the impedance matching condition and the quality factors. Mechano-electric power conversions including electrostatic induction, electromagnetic induction, and piezoelectric effect are discussed to study the scaling effect. Recent examples of MEMS VDRGs are reviewed and evaluated in terms of the power density.

6.
Micromachines (Basel) ; 11(1)2019 Dec 30.
Artigo em Inglês | MEDLINE | ID: mdl-31905932

RESUMO

Due to a limited lifetime of a battery, energy harvesters have been studied as alternative energy sources for implantable biomedical devices such as an implantable stimulator for epileptic seizure suppression. However, energy harvesters have weakness in providing stable power. We designed a neural recording circuit powered solely by a piezoelectric energy harvester, and applied its output to a seizure detector to analyze the reliability of the recorded signal. Performance of the seizure detector was evaluated. We found that the average time differences between with and without voltage variances were about 0.05 s under regular vibrations and about 0.07 s under irregular vibrations, respectively. The ratio of average true positive alarm period varied within about 0.02% under regular vibrations and 0.029% under irregular vibrations, respectively. The ratio of average false positive alarm period varied within about 0.004% under regular vibrations and 0.014% under irregular vibrations, respectively. This paper presents a reliability analysis of an epileptic seizure detector with a neural signal recording circuit powered by a piezoelectric energy harvester. The results showed that a supply voltage variance within ±10% could be acceptable for reliable operation of a seizure detector.

7.
J Biophotonics ; 12(5): e201800343, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30588762

RESUMO

We present a light emitting diode (LED)-based optical waveguide array that can optogenetically modulate genetically targeted neurons in the brain. The reusable part of the system consists of control electronics and conventional multi-wavelength LED. The disposable part comprises optical fibers assembled with microlens array fabricated on a silicon die. Both parts can be easily assembled and separated by snap fit structure. Measured light intensity is 3.35 mW/mm2 at 469 nm and 0.29 mW/mm2 at 590 nm when the applied current is 80 mA. In all the tested conditions, the light-induced temperature rise is under 0.5°C and over 90% of the relative light intensity is maintained at 2 mm-distance from the fiber tips. We further tested the efficiency of the optical array in vivo at 469 nm. When the optical array delivers light stimulation on to the visual cortex of a mouse expressing channelrhodopsin-2, the neural activity is significantly increased. The light-driven neural activity is successfully transformed into a percept of the mouse, showing significant learning of the task detecting the cortical stimulation. Our results demonstrate that the proposed optical array interfaces well with the neural circuits in vivo and the system is applicable to guide animal behaviors.


Assuntos
Equipamentos Descartáveis , Luz , Dispositivos Ópticos , Optogenética/instrumentação , Desenho de Equipamento , Temperatura Alta
8.
Micromachines (Basel) ; 8(10)2017 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-30400478

RESUMO

We present an electromagnetic linear vibration energy harvester with an array of rectangular permanent magnets as a springless proof mass. Instead of supporting the magnet assembly with spring element, ferrofluid has been used as a lubricating material. When external vibration is applied laterally to the harvester, magnet assembly slides back and forth on the channel with reduced friction and wear due to ferrofluid, which significantly improves the long-term reliability of the device. Electric power is generated across an array of copper windings formed at the bottom of the aluminum housing. A proof-of-concept harvester has been fabricated and tested with a vibration exciter at various input frequencies and accelerations. For the device where 5 µL of ferrofluid was used for lubrication, maximum output power of 493 µW has been generated, which was 4.37% higher than that without ferrofluid. Long-term reliability improvement due to ferrofluid lubrication has also been verified. For the device with ferrofluid, 1.02% decrease of output power has been observed, in contrast to 59.73% decrease of output power without ferrofluid after 93,600 cycles.

9.
Opt Express ; 24(14): 15813-21, 2016 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-27410851

RESUMO

We present an electromagnetic biaxial vector-graphic scanning micromirror. In contrast to conventional electromagnetic actuators using linear magnetic field, proposed device utilizes a radial magnetic field and uniquely designed current paths to enable the 2 degree-of-freedom scanning motion. As the radial field is generated by concentrically assembled magnets placed under the scanner die, large driving torque can be generated without the aid of hermetic packaging and relatively small device volume can be achieved. Mechanical half scan angle of 6.43° and 4.20° have been achieved at DC current of 250mA and 350mA for horizontal and vertical scans, respectively. Forced actuation along both scan axes has been realized by feedback control.

10.
Opt Express ; 23(13): 16792-802, 2015 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-26191691

RESUMO

We present the design, fabrication, and measurement results of an electromagnetic biaxial microscanner with mechanical amplification mechanism. A gimbaled scanner with two distinct single-crystal silicon layer thicknesses and integrated copper coils has been fabricated with combination of surface and bulk micromachining processes. A magnet assembly consisting of an array of permanent magnets and a pole piece has been placed under the substrate to provide high strength lateral magnetic field oriented 45° to two perpendicular scanning axes. Micromirror has been supported by additional gimbal to implement a mechanical amplification. A 1.2mm-diameter mirror with aluminum reflective surface has been actuated at 60Hz for vertical scan and at 21kHz for horizontal scan. Maximum scan angle of 36.12° at 21.19kHz and 17.62° at 60Hz have been obtained for horizontal and vertical scans, respectively.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...