Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
PLoS One ; 18(10): e0292389, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37796850

RESUMO

At-home rapid COVID-19 tests in the U.S. utilize nasal-swab specimens and require high viral loads to reliably give positive results. Longitudinal studies from the onset of infection have found infectious virus can present in oral specimens days before nasal. Detection and initiation of infection-control practices may therefore be delayed when nasal-swab rapid tests are used, resulting in greater transmission to contacts. We assessed whether index cases first identified by rapid nasal-swab COVID-19 tests had more transmission to household contacts than index cases who used other test types (tests with higher analytical sensitivity and/or non-nasal specimen types). In this observational cohort study, 370 individuals from 85 households with a recent COVID-19 case were screened at least daily by RT-qPCR on one or more self-collected upper-respiratory specimen types. A two-level random intercept model was used to assess the association between the infection outcome of household contacts and each covariable (household size, race/ethnicity, age, vaccination status, viral variant, infection-control practices, and whether a rapid nasal-swab test was used to initially identify the household index case). Transmission was quantified by adjusted secondary attack rates (aSAR) and adjusted odds ratios (aOR). An aSAR of 53.6% (95% CI 38.8-68.3%) was observed among households where the index case first tested positive by a rapid nasal-swab COVID-19 test, which was significantly higher than the aSAR for households where the index case utilized another test type (27.2% 95% CI 19.5-35.0%, P = 0.003 pairwise comparisons of predictive margins). We observed an aOR of 4.90 (95% CI 1.65-14.56) for transmission to household contacts when a nasal-swab rapid test was used to identify the index case, compared to other test types. Use of nasal-swab rapid COVID-19 tests for initial detection of infection and initiation of infection control may be less effective at limiting transmission to household contacts than other test types.


Assuntos
COVID-19 , Humanos , COVID-19/diagnóstico , COVID-19/epidemiologia , SARS-CoV-2 , Características da Família , Estudos de Coortes , Nariz
2.
J Reconstr Microsurg ; 39(7): 549-558, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36564049

RESUMO

BACKGROUND: Successful intraoperative microvascular anastomoses are essential for deep inferior epigastric perforator (DIEP) flap survival. This study identifies factors associated with anastomotic failure during DIEP flap reconstruction and analyzes the impact of these anastomotic failures on postoperative patient outcomes and surgical costs. METHODS: A retrospective cohort study was conducted of patients undergoing DIEP flap reconstruction at two high-volume tertiary care centers from January 2017 to December 2020. Patient demographics, intraoperative management, anastomotic technique, and postoperative outcomes were collected. Data were analyzed using Student's t-tests, Chi-square analysis, and multivariate logistic regression. RESULTS: Of the 270 patients included in our study (mean age 52, majority Caucasian [74.5%]), intraoperative anastomotic failure occurred in 26 (9.6%) patients. Increased number of circulating nurses increased risk of anastomotic failure (odds ratio [OR] 1.02, 95% confidence Interval [CI] 1.00-1.03, p <0.05). Presence of a junior resident also increased risk of anastomotic failure (OR 2.42, 95% CI 1.01-6.34, p <0.05). Increased surgeon years in practice was associated with decreased failures (OR 0.12, CI 0.02-0.60, p <0.05). Intraoperative anastomotic failure increased the odds of postoperative hematoma (OR 8.85, CI 1.35-59.1, p <0.05) and was associated with longer operating room times (bilateral DIEP: 2.25 hours longer, p <0.05), longer hospital stays (2.2 days longer, p <0.05), and higher total operating room cost ($28,529.50 vs. $37,272.80, p <0.05). CONCLUSION: Intraoperative anastomotic failures during DIEP flap reconstruction are associated with longer, more expensive cases and increased rates of postoperative complications. Presence of increased numbers of circulators and junior residents was associated with increased risk of anastomotic failure. Future research is necessary to develop practice guidelines for optimizing patient and surgical factors for intraoperative anastomotic success.


Assuntos
Mamoplastia , Retalho Perfurante , Humanos , Pessoa de Meia-Idade , Mamoplastia/métodos , Retalho Perfurante/irrigação sanguínea , Estudos Retrospectivos , Modelos Logísticos , Anastomose Cirúrgica , Complicações Pós-Operatórias , Artérias Epigástricas
3.
Microbiol Spectr ; 10(6): e0387322, 2022 12 21.
Artigo em Inglês | MEDLINE | ID: mdl-36287073

RESUMO

Optimizing specimen collection methods to achieve the most reliable SARS-CoV-2 detection for a given diagnostic sensitivity would improve testing and minimize COVID-19 outbreaks. From September 2020 to April 2021, we performed a household-transmission study in which participants self-collected specimens every morning and evening throughout acute SARS-CoV-2 infection. Seventy mildly symptomatic participants collected saliva, and of those, 29 also collected nasal swab specimens. Viral load was quantified in 1,194 saliva and 661 nasal swab specimens using a high-analytical-sensitivity reverse transcription-quantitative PCR (RT-qPCR) assay. Viral loads in both saliva and nasal swab specimens were significantly higher in morning-collected specimens than in evening-collected specimens after symptom onset. This aspect of the biology of SARS-CoV-2 infection has implications for diagnostic testing. We infer that morning collection would have resulted in significantly improved detection and that this advantage would be most pronounced for tests with low to moderate analytical sensitivity. Collecting specimens for COVID-19 testing in the morning offers a simple and low-cost improvement to clinical diagnostic sensitivity of low- to moderate-analytical-sensitivity tests. IMPORTANCE Our findings suggest that collecting saliva and nasal swab specimens in the morning immediately after waking yields higher SARS-CoV-2 viral loads than collection later in the day. The higher viral loads from morning specimen collection are predicted to significantly improve detection of SARS-CoV-2 in symptomatic individuals, particularly when using moderate- to low-analytical-sensitivity COVID-19 diagnostic tests, such as rapid antigen tests.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , COVID-19/diagnóstico , Teste para COVID-19 , Saliva , Técnicas de Laboratório Clínico/métodos , Carga Viral , Manejo de Espécimes/métodos
4.
J Clin Microbiol ; 60(2): e0178521, 2022 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-34911366

RESUMO

Early detection of SARS-CoV-2 infection is critical to reduce asymptomatic and presymptomatic transmission, curb the spread of variants, and maximize treatment efficacy. Low-analytical-sensitivity nasal-swab testing is commonly used for surveillance and symptomatic testing, but the ability of these tests to detect the earliest stages of infection has not been established. In this study, conducted between September 2020 and June 2021 in the greater Los Angeles County, California, area, initially SARS-CoV-2-negative household contacts of individuals diagnosed with COVID-19 prospectively self-collected paired anterior-nares nasal-swab and saliva samples twice daily for viral-load quantification by high-sensitivity reverse-transcription quantitative PCR (RT-qPCR) and digital-RT-PCR assays. We captured viral-load profiles from the incidence of infection for seven individuals and compared diagnostic sensitivities between respiratory sites. Among unvaccinated persons, testing saliva with a high-analytical-sensitivity assay detected infection up to 4.5 days before viral loads in nasal swabs reached concentrations detectable by low-analytical-sensitivity nasal-swab tests. For most participants, nasal swabs reached higher peak viral loads than saliva but were undetectable or at lower loads during the first few days of infection. High-analytical-sensitivity saliva testing was most reliable for earliest detection. Our study illustrates the value of acquiring early (within hours after a negative high-sensitivity test) viral-load profiles to guide the appropriate analytical sensitivity and respiratory site for detecting earliest infections. Such data are challenging to acquire but critical to designing optimal testing strategies with emerging variants in the current pandemic and to respond to future viral pandemics.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , Nasofaringe , Pandemias , Saliva , Manejo de Espécimes
5.
medRxiv ; 2021 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-33851180

RESUMO

Early detection of SARS-CoV-2 infection is critical to reduce asymptomatic and pre-symptomatic transmission, curb the spread of variants by travelers, and maximize treatment efficacy. Low-sensitivity nasal-swab testing (antigen and some nucleic-acid-amplification tests) is commonly used for surveillance and symptomatic testing, but the ability of low-sensitivity nasal-swab tests to detect the earliest stages of infection has not been established. In this case-ascertained study, initially-SARS-CoV-2-negative household contacts of individuals diagnosed with COVID-19 prospectively self-collected paired anterior-nares nasal-swab and saliva samples twice daily for viral-load quantification by high-sensitivity RT-qPCR and digital-RT-PCR assays. We captured viral-load profiles from the incidence of infection for seven individuals and compared diagnostic sensitivities between respiratory sites. Among unvaccinated persons, high-sensitivity saliva testing detected infection up to 4.5 days before viral loads in nasal swabs reached the limit of detection of low-sensitivity nasal-swab tests. For most participants, nasal swabs reached higher peak viral loads than saliva, but were undetectable or at lower loads during the first few days of infection. High-sensitivity saliva testing was most reliable for earliest detection. Our study illustrates the value of acquiring early (within hours after a negative high-sensitivity test) viral-load profiles to guide the appropriate analytical sensitivity and respiratory site for detecting earliest infections. Such data are challenging to acquire but critical to design optimal testing strategies in the current pandemic and will be required for responding to future viral pandemics. As new variants and viruses emerge, up-to-date data on viral kinetics are necessary to adjust testing strategies for reliable early detection of infections.

6.
medRxiv ; 2020 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-33330885

RESUMO

Transmission of SARS-CoV-2 in community settings often occurs before symptom onset, therefore testing strategies that can reliably detect people in the early phase of infection are urgently needed. Early detection of SARS-CoV-2 infection is especially critical to protect vulnerable populations who require frequent interactions with caretakers. Rapid COVID-19 tests have been proposed as an attractive strategy for surveillance, however a limitation of most rapid tests is their low sensitivity. Low-sensitivity tests are comparable to high sensitivity tests in detecting early infections when two assumptions are met: (1) viral load rises quickly (within hours) after infection and (2) viral load reaches and sustains high levels (>105-106 RNA copies/mL). However, there are no human data testing these assumptions. In this study, we document a case of presymptomatic household transmission from a healthy young adult to a sibling and a parent. Participants prospectively provided twice-daily saliva samples. Samples were analyzed by RT-qPCR and RT-ddPCR and we measured the complete viral load profiles throughout the course of infection of the sibling and parent. This study provides evidence that in at least some human cases of SARS-CoV-2, viral load rises slowly (over days, not hours) and not to such high levels to be detectable reliably by any low-sensitivity test. Additional viral load profiles from different samples types across a broad demographic must be obtained to describe the early phase of infection and determine which testing strategies will be most effective for identifying SARS-CoV-2 infection before transmission can occur.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...