Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Assunto principal
Intervalo de ano de publicação
1.
Sensors (Basel) ; 24(10)2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38793995

RESUMO

A broadband differential-MMIC low-noise amplifier (DLNA) using metamorphic high-electron-mobility transistors of 70 nm in Gallium Arsenide (70 nm GaAs mHEMT technology) is presented. The design and results of the performance measurements of the DLNA in the frequency band from 1 to 16 GHz are shown, with a high dynamic range, and a noise figure (NF) below 1.3 dB is obtained. In this work, two low-noise amplifiers (LNAs) were designed and manufactured in the OMMIC foundry: a dual LNA, which we call balanced, and a differential LNA, which we call DLNA. However, the paper focuses primarily on DLNA because of its differential architecture. Both use a 70 nm GaAs mHEMT space-qualified technology with a cutoff frequency of 300 GHz. With a low power bias Vbias/Ibias (5 V/40.5 mA), NF < 1.07 dB "on wafer" was achieved, from 2 to 16 GHz; while with the measurements made "on jig", NF = 1.1 dB, from 1 to 10 GHz. Furthermore, it was obtained that NF < 1.5 dB, from 1 to 16 GHz, with a figure of merit equal to 145.5 GHz/mW. Finally, with the proposed topology, several LNAs were designed and manufactured, both in the OMMIC process and in other foundries with other processes, such as UMS. The experimental results showed that the NF of the DLNA MMIC with multioctave bandwidth that was built in the frequency range of the L-, S-, C-, and X-bands was satisfactory.

2.
Sensors (Basel) ; 23(23)2023 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-38067975

RESUMO

In this paper, the precise design of a high-power amplifier (HPA) is shown, along with the problems associated with the stability of "on-wafer" measurements. Here, techniques to predict possible oscillations are discussed to ensure the stability of a monolithic microwave-integrated circuit (MMIC). In addition, a deep reflection is made on the instabilities that occur when measuring both on wafer and using a mounted chip. Stability techniques are used as tools to characterize measurement results. Both a precise design and instabilities are shown through the design of a three-stage X-band HPA in gallium nitride (GaN) from the WIN Semiconductors Corp. foundry. As a result, satisfactory performance was obtained, achieving a maximum output power equal to 42 dBm and power-added efficiency of 32% at a 20 V drain bias. In addition to identifying critical points in the design or measurement of the HPA, this research shows that the stability of the amplifier can be verified through a simple analysis and that instabilities are often linked to errors in the measurement process or in the characterization of the measurement process.

3.
Sensors (Basel) ; 22(22)2022 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-36433581

RESUMO

In this paper, a comparative analysis between the PM2.5 concentration in downtown Quito, Ecuador, during the COVID-19 pandemic in 2020 and the previous five years (from 2015 to 2019) was carried out. Here, in order to fill in the missing data and achieve homogeneity, eight datasets were constructed, and 35 different estimates were used together with six interpolation methods to put in the estimated value of the missing data. Additionally, the quality of the estimations was verified by using the sum of squared residuals and the following correlation coefficients: Pearson's r, Kendall's τ, and Spearman's ρ. Next, feature vectors were constructed from the data under study using the wavelet transform, and the differences between feature vectors were studied by using principal component analysis and multidimensional scaling. Finally, a robust method to impute missing data in time series and characterize objects is presented. This method was used to support the hypothesis that there were significant differences between the PM2.5 concentration in downtown Quito in 2020 and 2015-2019.


Assuntos
COVID-19 , Humanos , COVID-19/epidemiologia , Pandemias , Controle de Doenças Transmissíveis , Projetos de Pesquisa , Material Particulado
4.
Sensors (Basel) ; 21(1)2021 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-33401639

RESUMO

This paper analyzes 12 years of tropospheric ozone (O3) concentration measurements using robust techniques. The measurements were taken at an air quality monitoring station called Belisario, which is in Quito, Ecuador; the data collection time period was 1 January 2008 to 31 December 2019, and the measurements were carried out using photometric O3 analyzers. Here, the measurement results were used to build variables that represented hours, days, months, and years, and were then classified and categorized. The index of air quality (IAQ) of the city was used to make the classifications, and robust and nonrobust confidence intervals were used to make the categorizations. Furthermore, robust analysis methods were compared with classical methods, nonparametric methods, and bootstrap-based methods. The results showed that the analysis using robust methods is better than the analysis using nonrobust methods, which are not immune to the influence of extreme observations. Using all of the aforementioned methods, confidence intervals were used to both establish and quantify differences between categories of the groups of variables under study. In addition, the central tendency and variability of the O3 concentration at Belisario station were exhaustively analyzed, concluding that said concentration was stable for years, highly variable for months and hours, and slightly changing between the days of the week. Additionally, according to the criteria established by the IAQ, it was shown that in Quito, the O3 concentration levels during the study period were not harmful to human health.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...