Opt Lett ; 48(15): 3921-3924, 2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37527083

RESUMO

This pilot study reports the development of optical coherence tomography (OCT) split-spectrum amplitude-decorrelation optoretinography (SSADOR) that measures spatially resolved photoreceptor response to light stimuli. Using spectrally multiplexed narrowband OCT, SSADOR improves sensitivity to microscopic changes without the need for cellular resolution or optical phase detection. Therefore, a large field of view (up to 3 × 1 mm2 demonstrated) using conventional OCT instrument design can be achieved, paving the way for clinical translation. SSADOR promises a fast, objective, and quantifiable functional biomarker for photoreceptor damage in the macula.


Assuntos
Tomografia de Coerência Óptica , Tomografia de Coerência Óptica/métodos , Projetos Piloto
2.
Sci Rep ; 12(1): 14834, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-36050445

RESUMO

Quantitative evaluation of the human corneal grafts stored in the tissue banks is usually limited to endothelial cell density and central thickness. Swept-source OCT (SS-OCT) is capable of measuring the central curvatures of the corneal tissue prepared for transplantation without loss of sterileness, providing insights on its refractive state. The aim of the paper is to compare in vitro SS-OCT measurements with pre-excision values. Hand-held keratometry and ultrasound pachymetry was performed on 22 corneas before excision of corneoscleral button and insertion in the vial with Eusol-C solution (AlchimiaS.r.l, Nicolò, Italy). After 12 to 36 h of hypothermic storage the corneas were examined within the vials with custom built SS-OCT system maintaining a sterile environment. The anterior and posterior central curvatures, and central corneal thickness (CCT) were measured. Rotation of the corneoscleral button was controlled by making a 6-o'clock mark during excision. Mean pre-excision CCT was 626.45 ± 28.71 µm and 468.05 ± 52.96 µm when measured with SS OCT (r = 0.55; p < 0.001). Respective values for average keratometry were 7.74 ± 0.39 mm and 7.92 ± 0.57 mm (r = 0.6; p = 0.22). Although high differences were observed in corneal thickness, keratometric radius of curvature at the flat (r = 0.42; p < 0.001) and steep (r = 0.62; p = 0.014) meridian of the anterior corneal surface, as well as corneal anterior astigmatism (r = 0.3; p < 0.001), showed good correlation with pre-excision values. SS-OCT is capable of providing quantitative evaluation of the human corneal grafts in hypothermic storage. Good correlation between curvature measurements before excision and during banking in the vial indicates its clinical utility.


Assuntos
Doenças da Córnea , Transplante de Córnea , Córnea/cirurgia , Paquimetria Corneana , Bancos de Olhos , Humanos , Reprodutibilidade dos Testes , Tomografia de Coerência Óptica
3.
Biomed Opt Express ; 13(4): 2174-2185, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-35519252

RESUMO

Cataract is one of the common causes of visual impairment due to opacification of the crystalline lens. Increased intraocular scattering affects the vision of cataract patients by reducing the quality of the retinal image. In this study, an amplitude modulation-based scatter compensation (AM-SC) method is developed to minimize the impact of straylight on the retinal image. The performance of the AM-SC method was quantified by numerical simulations of point spread function and retinal images in the presence of different amounts of straylight. The approach was also experimentally realized in a single-pass system with a digital micro-mirror device used as a spatial amplitude modulator. We showed that the AM-SC method allows to enhance contrast sensitivity in the human eyes in vivo with induced scattering.

4.
Sci Rep ; 11(1): 12460, 2021 06 14.
Artigo em Inglês | MEDLINE | ID: mdl-34127727

RESUMO

The geometry of contact lenses can be altered by wear but determining the changes that occur in soft contact lenses (SCLs) is challenging. This study aimed to investigate the shape alterations of daily disposable SCLs after wear using swept-source optical coherence tomography (SS-OCT). Forty-five eyes with myopia of - 3.00 diopters (D) were enrolled. The participants wore three types of SCLs: hydrogel lens (nesofilcon A) and silicone hydrogel lenses (delefilcon A and stenfilcon A). The SCLs were scanned 3-6 min after lens removal. We found a significant decrease in the SCL anterior curvature: 0.24 ± 0.17 mm for nesofilcon A, 0.44 ± 0.21 mm for delefilcon A, and 0.53 ± 0.29 mm for stenfilcon A. The changes in the anterior curvature of SCLs correlated moderately with the mean corneal keratometry; Pearson's correlation coefficients for nesofilcon A and delefilcon A were 0.57 and 0.52, respectively (P < 0.001). A statistically significant change in the total diameter was observed in SCL made of stenfilcon A (0.39 mm, P < 0.001). To conclude, the central radii of curvature decreased after a wearing period for all three types of daily disposable SCLs to imitate the anterior corneal surface, however, the changes in other geometrical parameters measured with SS-OCT were lens-specific.

5.
Ophthalmic Physiol Opt ; 41(4): 683-690, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33945648

RESUMO

PURPOSE: To measure geometrical changes in the anterior surface of the cornea after wearing silicon hydrogel (SiH) soft contact lenses continuously for 1 week. METHODS: Forty-three eyes with 3.0D of myopia and 22 eyes with 3.0D of hyperopia were enrolled in the prospective, interventional study. All subjects underwent a general eye examination, corneal tomography with wavefront aberration analysis, corneal thickness measurements and epithelial thickness mapping before and after wearing SiH lenses (Acuvue Oasys) for 7 days. RESULTS: No significant changes in average keratometry were observed in either refractive group. In the myopic group, keratometry findings for the flat meridian (K1) and central corneal thickness decreased significantly. After +3.0 D lens wear in the hyperopic group, a significant decrease in epithelial thickness up to 3.19 µm was observed in the central and paracentral cornea, (p < 0.001). In both refractive groups, the largest epithelial thickness increase was seen in the periphery. A decrease in spherical aberration was noted in myopic eyes, while an increase of both higher order corneal aberrations and coma was found in hyperopic subjects. CONCLUSION: Extended wear of SiH lenses results in a significant change in epithelial thickness leading to alteration in the geometry of the anterior surface of the cornea, particularly in hyperopic patients. These epithelial thickness variations lead to changes in the higher order aberrations of the cornea.


Assuntos
Lentes de Contato Hidrofílicas , Silicones , Lentes de Contato Hidrofílicas/efeitos adversos , Córnea , Humanos , Hidrogéis , Estudos Prospectivos
6.
Invest Ophthalmol Vis Sci ; 62(4): 31, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-33929483

RESUMO

Purpose: The purpose of this study was to characterize age-related changes in anterior human vitreous with 3-D swept source optical coherence tomography (SS-OCT) and evaluate associations with axial length (AL) and contrast sensitivity function (CSF). Methods: There were 49 phakic eyes in 49 patients (40.0 ± 19.3 years) had 3-D volumetric scanning of the lens and retrolental vitreous with SS-OCT at 1050 nm. OCT-derived indices of vitreous optical density (VOD), vitreous opacification ratio (VOR), and lens optical density (LOD) were correlated with AL and double-pass assessment of retinal point spread function (Objective Scatter Index [OSI]). CSF was measured using an adaptive-optics visual simulator (area under log-log contrast sensitivity function [AULCSF]). Results: Vitreous SS-OCT detected gel vitreous, liquefied lacunae, Berger's space, retrolental laminae, and fibrous opacifications. VOD, VOR, and LOD showed high reproducibility (intraclass correlation coefficients 0.968, 0.975, and 0.998, respectively). VOD was highly correlated with VOR (Pearson's R = 0.96, P < 0.000001). VOD, VOR, and LOD correlated with age (R = 0.48, 0.58, and 0.85, P < 0.001 for each). VOR and LOD correlated with OSI (R = 0.36, P = 0.0094, and R = 0.36, P = 0.0096, respectively). VOR correlated negatively with AULCSF (R = -0.53, P < 0.00009), which was related to OSI. Myopic eyes had higher OSI than nonmyopic eyes (P = 0.0121), consistent with correlation between OSI and AL (R = 0.37, P = 0.0091). Multivariable regression confirmed these findings. Conclusions: SS-OCT visualized microstructural features of anterior human vitreous, where opacification is associated with increased light scattering and CSF degradation. SS-OCT enables high-resolution optical evaluation of vitreous opacities.


Assuntos
Envelhecimento , Comprimento Axial do Olho/diagnóstico por imagem , Sensibilidades de Contraste/fisiologia , Miopia/diagnóstico , Tomografia de Coerência Óptica/métodos , Corpo Vítreo/diagnóstico por imagem , Adolescente , Adulto , Idoso , Criança , Estudos Transversais , Feminino , Humanos , Cristalino/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Miopia/fisiopatologia , Reprodutibilidade dos Testes , Adulto Jovem
7.
PLoS One ; 15(11): e0242095, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33166364

RESUMO

Contact lens wear causes mutual interactions between the ocular surface and the lens, which may affect comfort as well as vision. The aim of this study was to examine deformations in modern positive- and negative-powered silicone hydrogel soft contact lenses (SiH SCLs) after 7 days of continuous wear. This pre-post interventional study included 64 eyes: 42 eyes with myopia of -3.00 D and 22 eyes with hyperopia of +3.00 D. All patients underwent general ophthalmic examination, corneal topography/tomography, total corneal and epithelial thickness mapping, and specular microscopy before and after the wearing period. SiH SCLs made of senofilcon A were worn continuously for 7 days on all eligible eyes. The geometry of the new and used lenses was measured 3 to 6 minutes after removal in two perpendicular planes using a custom-made swept source optical coherence tomography (SS-OCT) system for in vitro measurements. The anterior and posterior radii of curvature decreased in -3.00 D lenses in two perpendicular planes. This effect correlated significantly with average keratometry of the cornea. Sagittal lens height was lower in +3.00 D lens after wear, which correlated moderately with the corneal sagittal height. A significant decrease in central corneal epithelial thickness was observed after wearing +3.0 D lenses. In conclusion, SiH SCLs made of senofilcon A undergo minor deformations after 7-day continuous wear. Geometry modifications are different for -3.00 D and +3.00 D lenses, and they imitate the shape of the anterior eye surface. These geometric changes are accompanied by a decrease in the central thickness of corneal epithelium after +3.00 D lens wear.


Assuntos
Lentes de Contato de Uso Prolongado/normas , Adulto , Lentes de Contato de Uso Prolongado/efeitos adversos , Córnea/efeitos dos fármacos , Córnea/fisiologia , Feminino , Humanos , Hidrogéis/efeitos adversos , Hidrogéis/química , Hidrogéis/normas , Masculino , Silicones/efeitos adversos , Silicones/química , Silicones/normas , Estresse Mecânico
8.
Biomed Opt Express ; 11(10): 5388-5400, 2020 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-33149958

RESUMO

We demonstrate in vivo three-dimensional (3-D) visualization of crystalline lens sutures in healthy eyes using swept source optical coherence tomography (SS-OCT). Volumetric data sets of the crystalline lenses were acquired and processed to obtain enhanced contrast projection images and to extract suture patterns in both anterior and posterior lens. The results presented different types of the sutures including Y-sutures, simple and complex star sutures. Age-related changes in suture arrangement were characterized quantitatively. Crystalline lens suture imaging with SS-OCT might be a useful tool in fundamental studies on development and ageing of human lens.

9.
Biomed Opt Express ; 10(7): 3663-3680, 2019 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-31467798

RESUMO

We demonstrate a swept source OCT-based ocular biometer integrated with an air-puff stimulus to study the reaction of the eye to mechanical stimulation in vivo. The system enables simultaneous measurement of the stimulus strength and high-speed imaging of the eye dynamics along the visual axis. We characterize the stimulus and perform optimization of the data acquisition for a proper interpretation of the results. Access to the dynamics of axial eye length allows for a determination of the eye retraction, which is used to correct the air-puff induced displacement of ocular structures. We define the parameters to quantify the reaction of the eye to the air puff and determine their reproducibility in a group of healthy subjects. We observe the corneal deformation process and axial wobbling of the crystalline lens. OCT biometer combined with the air puff is the first instrument with the potential to provide comprehensive information on the biomechanics of ocular components.

10.
Invest Ophthalmol Vis Sci ; 60(6): 1979-1986, 2019 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-31050724

RESUMO

Purpose: To analyze the dynamics of all optical components of the eye and the behavior of the eyeball under air-puff conditions in vivo. To determine the impact of the intraocular pressure (IOP) on the air-puff-induced deformation of the eye. Methods: Twenty eyes of 20 healthy subjects were included in this study. The dynamics of the ocular components, such as the cornea, the crystalline lens, and the retina, was measured by a prototype swept source optical coherence tomography biometer integrated with the air-puff system. The system allows to acquire a series of axial scans at the same location as a function of time with no transverse scanning. Several parameters were extracted from optical coherence tomography data. The IOP was measured using a Goldmann applanation tonometry. The measurements of the eyes were performed before and 2 hours after administration of IOP-reducing drops, namely, 0.2 % brimonidine tartrate. Results: There is a statistically significant correlation of corneal thickness, vitreous depth, and eye length with IOP. The deformation amplitudes of the cornea and the crystalline lens are inversely proportional to the IOP, but statistical significance is achieved only for the cornea. The crystalline lens is displaced without compression, and the return has the form of wobbling. The reduction of IOP level induces corresponding changes in the extracted parameters. Conclusions: Optical biometry combined with air puff provides comprehensive information on the in vivo behavior of all ocular components, including the crystalline lens. Measurement of the axial length dynamics of during deformation enables correcting the deformation for eye retraction.


Assuntos
Comprimento Axial do Olho/anatomia & histologia , Biometria/métodos , Córnea/anatomia & histologia , Pressão Intraocular/fisiologia , Cristalino/anatomia & histologia , Adulto , Ar , Estudos Transversais , Feminino , Voluntários Saudáveis , Humanos , Masculino , Reprodutibilidade dos Testes , Tomografia de Coerência Óptica , Tonometria Ocular , Corpo Vítreo/anatomia & histologia , Adulto Jovem