Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Vet Med Sci ; 10(4): e1501, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38923315

RESUMO

INTRODUCTION: Silica-sprayed tubes (SSTs) are often used to transport synovial fluid samples in equine practice. They promote the coagulation of the sample. The objective of the study is to evaluate the effect of SST on bacterial culture. MATERIALS AND METHODS: The study was divided into two parts: sterile saline (Part A) and synovial fluid (Part B). Four common bacteria associated with equine synovial sepsis were used: Streptococcus pyogenes, Escherichia coli, Staphylococcus aureus and methicillin-resistant S. aureus (MRSA). Three collection tubes were used: STT, plain (no-additives) and brain and heart infusion (BHI) broth. Bacteria were cultured in horse blood agar plates for 48 h. Outcome variables were negative culture, positive culture and total number of colony-forming units (CFUs). Statistical analysis was performed using Mann-Whitney U test, and significance was set at p < 0.05. RESULTS: The total number of agar plates read was 1557 (779 saline; 778 synovial fluid). Total negative cultures were 25/779 on saline and 3/778 on synovial fluid. In broth, maximum growth CFU was achieved after 8 h for both saline and synovial fluid for all bacteria. S. pyogenesand E. coli produced a significantly lower number of CFU when in SST compared to plain or broth after 4 h, whereas S. aureus (American Type Culture Collection [ATCC] and MRSA) only after 24 h. DISCUSSION: Silica-containing tubes reduced bacterial proliferation, whereas the use of a BHI broth provided the highest bacterial load in the sample. The use of SST may have a negative effect on bacterial proliferation in samples obtained from clinical cases.


Assuntos
Dióxido de Silício , Líquido Sinovial , Líquido Sinovial/microbiologia , Animais , Cavalos , Dióxido de Silício/química , Manejo de Espécimes/métodos , Manejo de Espécimes/veterinária , Escherichia coli/efeitos dos fármacos , Escherichia coli/fisiologia , Staphylococcus aureus/efeitos dos fármacos , Staphylococcus aureus/fisiologia , Staphylococcus aureus/isolamento & purificação , Técnicas Bacteriológicas/veterinária , Streptococcus pyogenes/efeitos dos fármacos , Streptococcus pyogenes/isolamento & purificação , Staphylococcus aureus Resistente à Meticilina/efeitos dos fármacos , Staphylococcus aureus Resistente à Meticilina/isolamento & purificação
2.
Vet Rec ; 187(8): e62, 2020 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-32327552

RESUMO

BACKGROUND: Refractometric determination of total protein (TP) in synovial fluid (SF) is commonly used for diagnosis and monitoring of synovial sepsis in horses. Previous studies have shown that elevated concentrations of certain anticoagulants may overestimate refractometric determination of TP concentration. OBJECTIVES: The aim of the study was to evaluate the effect of different concentrations of dipotassium EDTA (K2EDTA) and lithium heparin (LH) on TP determination by using a hand-held refractometer in equine synovial fluid. STUDY DESIGN: Cross-section observational study. METHODS: Thirty samples of synovial fluid obtained from 22 horses with different synovial conditions were collected. Synovial fluid samples were separated into different aliquots and placed in commercially available collection tubes containing K2EDTA or LH at four different concentrations (1.76, 3.52, 7.04 and 17.6 mg/ml for K2EDTA; 16, 32, 64 and 160 IU/ml for LH) . Refractometric TP determination was performed on untreated and K2EDTA and LH aliquots with a hand-held refractometer and by spectophotometric Biuret method as the gold standard. RESULTS: Refractometric TP determination was overestimated in SF samples containing 10 times the recommended K2EDTA concentrations. Lower concentrations of K2EDTA and LH concentrations did not affect refractometric TP determinations. MAIN LIMITATIONS: Limited number of samples mostly obtained from large synovial structures. CONCLUSION: To avoid incorrect TP determination, the use of LH containing collection tubes may be an appropriate alternative when the SF volume available is not enough to fill the K2EDTA collection tube.


Assuntos
Proteínas Sanguíneas/efeitos dos fármacos , Ácido Edético/farmacologia , Heparina/farmacologia , Lítio/farmacologia , Líquido Sinovial/química , Animais , Estudos Transversais , Cavalos , Refratometria/veterinária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA