Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nat Prod Res ; : 1-6, 2024 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-38251834

RESUMO

Two new protopanaxadiol type sapogenins, (3ß,12ß)-3,12,20-trihydroxydammar-24-en-26-al (1) and (3ß,12ß)-3,12,20-trihydroxydammar-24-en-26-oic acid (2), were isolated from the alkali hydrolysate of stems-leaves of Panax notoginseng, along with seven known analogues (3-9). Their structures were elucidated by spectroscopic analyses and single-crystal X-ray diffraction. Compound 2 and the known sapogenins 5-8 displayed weak to moderate inhibition of NO production in LPS-induced RAW264.7 macrophages with IC50 values from 44.5 to 143.6 µM, respectively.

2.
Sci Rep ; 13(1): 19859, 2023 11 13.
Artigo em Inglês | MEDLINE | ID: mdl-37963909

RESUMO

Theoretically pulse wave velocity (PWV) is obtained by calculating the distance between two waveform probes divided by the time difference, and PWV ratio is used to assess the arterial stiffness gradient (SG) from proximal to distal. The aim was to investigate segmental upper-limb PWV (ulPWV) differences and the effects of hypertension and or aging on each ulPWV and SG. The study collected multi-waveform signals and conduction distances from 167 healthy individuals and 92 hypertensive patients. The results showed significant differences between ulPWVs (P < 0.001), with increased and then decreased vascular stiffness along the proximal transmission to the distal peripheral artery and then to the finger. Adjusted for age and sex, ulPWVs in hypertension exceeded that of healthy individuals, with significant differences between groups aged ≥ 50 years (P < 0.05). The hrPWV/rfPWV (heart-radial/radial-finger) was reduced in hypertension and differed significantly between the aged ≥ 50 years (P = 0.015); the ratio of baPWV (brachial-ankle) to ulPWV differed significantly between groups (P < 0.05). Hypertension affected the consistency of rfPWV with hfPWV (heart-finger). The findings suggest that segmented ulPWV is instrumental in providing stiffness corresponding to the physiological structure of the vessel. The superimposition of hypertension and or aging exacerbates peripheral arterial stiffness, as well as alteration in stiffness gradient.


Assuntos
Hipertensão , Rigidez Vascular , Humanos , Rigidez Vascular/fisiologia , Análise de Onda de Pulso/métodos , Artérias , Extremidade Superior
3.
Org Biomol Chem ; 21(8): 1737-1743, 2023 02 22.
Artigo em Inglês | MEDLINE | ID: mdl-36723156

RESUMO

Three novel actinomycins, actimomycin S (1), neo-actinomycins C and D (2 and 3), and one new benzo[d]oxazole alkaloid (4) were isolated from the Streptomyces sp. strain S22, along with three known congeners F9 (5), X2 (6) and X0ß (7) and 2-acetylamino-3-hydroxyl-4-methyl-benzoic acid methyl ester (8). The structures of the new products were elucidated by spectroscopic methods, and the absolute configuration of amino acid residues was determined by Marfey's analysis. Actinomycin S contains an aspartic acid (Asp) residue in the ß-peptidolactone ring. This is the first report of an Asp residue within an actinomycin-type natural product. Notably, neo-actinomycins C and D feature a rare tetracyclic 5H-oxazolo[4,5-b]phenoxazine chromophore. Among these, neo-actinomycin D, with an unprecedented molecular formula, represents the highest molecular weight member in the actinomycin family. Actinomycins 1-3 exhibited antimicrobial activity against multiple resistant "ESKAPE" pathogens with MIC values ranging from 1.25 to 80.0 µg mL-1. In addition, 1-3 showed potent cytotoxic activities against the HepG2 liver carcinoma cell line with IC50 values of 0.10, 0.32, and 0.024 µM, respectively. Furthermore, 1 inhibited cell proliferation by inducing G0-G1 phase arrest in the cell cycle.


Assuntos
Antineoplásicos , Streptomyces , Dactinomicina , Streptomyces/metabolismo , Antineoplásicos/farmacologia , Análise Espectral , Aminoácidos/metabolismo
4.
Med Rev (Berl) ; 1(2): 172-198, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37724302

RESUMO

Traditional Chinese Medicine (TCM), as an effective alternative medicine, utilizes tongue diagnosis as a major method to assess the patient's health status by examining the tongue's color, shape, and texture. Tongue images can also give the pre-disease indications without any significant disease symptoms, which provides a basis for preventive medicine and lifestyle adjustment. However, traditional tongue diagnosis has limitations, as the process may be subjective and inconsistent. Hence, computer-aided tongue diagnoses have a great potential to provide more consistent and objective health assessments. This paper reviewed the current trends in TCM tongue diagnosis, including tongue image acquisition hardware, tongue segmentation, feature extraction, color correction, tongue classification, and tongue diagnosis system. We also present a case of TCM constitution classification based on tongue images.

5.
Biomed Res Int ; 2018: 2964816, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30534557

RESUMO

OBJECTIVE: In this study, machine learning was utilized to classify and predict pulse wave of hypertensive group and healthy group and assess the risk of hypertension by observing the dynamic change of the pulse wave and provide an objective reference for clinical application of pulse diagnosis in traditional Chinese medicine (TCM). METHOD: The basic information from 450 hypertensive cases and 479 healthy cases was collected by self-developed H20 questionnaires and pulse wave information was acquired by self-developed pulse diagnostic instrument (PDA-1). H20 questionnaires and pulse wave information were used as input variables to obtain different machine learning classification models of hypertension. This method was aimed at analyzing the influence of pulse wave on the accuracy and stability of machine learning model, as well as the feature contribution of hypertension model after removing noise by K-means. RESULT: Compared with the classification results before removing noise, the accuracy and the area under the curve (AUC) had been improved. The accuracy rates of AdaBoost, Gradient Boosting, and Random Forest (RF) were 86.41%, 86.41%, and 85.33%, respectively. AUC were 0.86, 0.86, and 0.85, respectively. The maximum accuracy of SVM increased from 79.57% to 83.15%, and the AUC stability increased from 0.79 to 0.83. In addition, the features of importance on traditional statistics and machine learning were consistent. After removing noise, the features with large changes were h1/t1, w1/t, t, w2, h2, t1, and t5 in AdaBoost and Gradient Boosting (top10). The common variables for machine learning and traditional statistics were h1/t1, h5, t, Ad, BMI, and t2. CONCLUSION: Pulse wave-based diagnostic method of hypertension has significant value in reference. In view of the feasibility of digital-pulse-wave diagnosis and dynamically evaluating hypertension, it provides the research direction and foundation for Chinese medicine in the dynamic evaluation of modern disease diagnosis and curative effect.


Assuntos
Hipertensão/diagnóstico , Aprendizado de Máquina , Análise de Onda de Pulso , Adulto , Algoritmos , Análise por Conglomerados , Feminino , Humanos , Masculino , Curva ROC
6.
Artigo em Inglês | MEDLINE | ID: mdl-30369958

RESUMO

This study aims at introducing a method for individual agreement evaluation to identify the discordant raters from the experts' group. We exclude those experts and decide the best experts selection method, so as to improve the reliability of the constructed tongue image database based on experts' opinions. Fifty experienced experts from the TCM diagnostic field all over China were invited to give ratings for 300 randomly selected tongue images. Gwet's AC1 (first-order agreement coefficient) was used to calculate the interrater and intrarater agreement. The optimization of the interrater agreement and the disagreement score were put forward to evaluate the external consistency for individual expert. The proposed method could successfully optimize the interrater agreement. By comparing three experts' selection methods, the interrater agreement was, respectively, increased from 0.53 [0.32-0.75] for original one to 0.64 [0.39-0.80] using method A (inclusion of experts whose intrarater agreement>0.6), 0.69 [0.63-0.81] using method B (inclusion of experts whose disagreement score="0"), and 0.76 [0.67-0.83] using method C (inclusion of experts whose intrarater agreement>0.6& disagreement score="0"). In this study, we provide an estimate of external consistency for individual expert, and the comprehensive consideration of both the internal consistency and the external consistency for each expert would be superior to either one in the tongue image construction based on expert opinions.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...