Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Expert Rev Med Devices ; 20(12): 1079-1086, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37942898

RESUMO

INTRODUCTION: The direct anterior approach (DAA) has its origins in the first and oldest approach for hip replacement in the literature, but at the same time it would not be fanciful to suggest its increasing popularity as the latest approach for hip replacement procedures, especially among younger surgeons. However, in a geographical context, the DAA is not considered the major approach in most countries. Moreover, the term DAA encompasses numerous variations in terms of technique. AREAS COVERED: In this narrative review, we describe our recent experience of advances in the DAA in terms of improved techniques and devices, along with some of its disadvantages. Also, we express our perspective on its future application. EXPERT OPINIONS: The DAA is established as one of exemplary approaches to THA. The use of fluoroscopy, the traction table, and appropriate soft tissue management has become essential in the DAA for a safe and trouble-free procedure with adequate patient comfort. With the combination of recent technologies such as robotics, three-dimensional preoperative planning, and artificial intelligence (AI)-based surgeon assist systems, we can look forward to the DAA being performed more efficiently in the future.


Assuntos
Artroplastia de Quadril , Cirurgiões , Humanos , Inteligência Artificial , Tração , Estudos Retrospectivos
2.
Sci Rep ; 11(1): 17195, 2021 08 25.
Artigo em Inglês | MEDLINE | ID: mdl-34433884

RESUMO

The aim of this study was to evaluate how the Charlson Comorbidity Index (CCI) scores contribute to early recovery and 2-year mortality in elderly patients undergoing surgical treatment of inter-trochanteric fractures. 60 cases with unilateral intertrochanteric fracture were retrospectively analyzed and divided into Low-CCI group (CCI: 1-4) or high-CCI groups (CCI: 5-6). All the patients' electronic hospital records were reviewed. The preoperative situations (demographic data, comorbidities and fracture conditions), perioperative situations (wait time, operation time, implant choice, blood loss, transfusion or not) and postoperative situations (complications, first time out of bed, function about 1-/2- week and 2-year mortality) were recorded. 51.67% were in low-CCI group and 48.33% in high-CCI group. The survival rates in low- and high-CCI group were 93.5% and 86.2% respectively. According to the functional results of 1- or 2- week after operation, no significant difference was found (P = 0.955, 0.140). Log-rank analysis showed that the main prognostic factors were blood loss, first time out of bed and complication (P < 0.05). Multivariate analysis confirmed that complication and first time out of bed were significant factor on survival rate (P = 0.029, 0.010). Charlson comorbidity index maybe not the indicator of 2-year mortality in older patients with intertrochanteric fractures. In order to improve the prognosis, more attentions should be paid to reduce the complications and encourage postoperative earlier excise out of bed.


Assuntos
Fixação de Fratura/estatística & dados numéricos , Fraturas do Quadril/epidemiologia , Mortalidade/tendências , Complicações Pós-Operatórias/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Comorbidade , Feminino , Fixação de Fratura/efeitos adversos , Fraturas do Quadril/cirurgia , Hospitalização/estatística & dados numéricos , Humanos , Masculino , Análise de Sobrevida
3.
J Arthroplasty ; 36(7): 2530-2535, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33744082

RESUMO

BACKGROUND: Although the antidislocation effect of total hip arthroplasty (THA) via the direct anterior approach (DAA) with dual mobility cup (DMC) for displaced femoral neck fracture (FNF) has already been reported, the clinical result of DMC-DAA-THA for displaced FNF in terms of mortality, complications, and walking ability are still unclear. METHODS: 106 cases with DMC-DAA-THA for displaced FNF were investigated of dislocation; perioperative complications; 3-, 6-, and12-month mortality rate; and pre/early postoperative walking ability. The walking ability was stratified into the following four categories: (1) use of a wheelchair (no walking), (2) walking alongside a support (including walkers designed for the elderly), (3) walking using one stick, and (4) unaided walking. RESULTS: There was no dislocation withing one-year postoperative. The 3-, 6-, and 12-month mortality rate was 2.8%, 4.7%, and 5.7%. Total complications occurred in 14 cases (14.7%). Although there was no revision surgery, two cases (1.9%) of intraoperative fracture treated without additional fixation, and one case of postoperative fracture was occurred. Among patients with preinjury walking category 2, 3, and 4 (total 94 cases), the number of patients who recovered same walking category at two-week postoperation was 56 cases (59.6%). CONCLUSIONS: Our study demonstrated that DMC-DAA-THA for displaced FNF offered quick recovery of walking ability with no dislocation and low one-year mortality rate. We believe that the combination of early postoperative recovery due to the minimal invasiveness of the DAA and decreased dislocation rate due to increased range of motion by DMC and adequate soft tissue tension by DAA contributed to null dislocation.


Assuntos
Artroplastia de Quadril , Fraturas do Colo Femoral , Prótese de Quadril , Idoso , Artroplastia de Quadril/efeitos adversos , Fraturas do Colo Femoral/cirurgia , Humanos , Reoperação
4.
Trauma Case Rep ; 31: 100381, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33426258

RESUMO

INTRODUCTION: In recent years, it has been reported that periprosthetic femoral fractures in the form of atypical femoral fractures (AFFs) are found occasionally as difficult-to-treat conditions. To date, there have been no reports of interprosthetic femoral fractures (IPFFs) having the form of AFFs. We report a case of an atypical IPFF with breakage of the plate due to abnormal femoral alignment. CASE REPORT: A 70-year-old woman was admitted. She underwent left knee replacement and left hemi-arthroplasty at ages 61 and 60. And she had been taking bisphosphonate for 5 years. A plain X-ray revealed IPFF. The fracture was a complete transverse fracture with circumscribed thickening of the lateral cortical bone ("beak sign") at the fracture site. She underwent surgery. A reversed condylar locking compression plate (LCP) was used for internal fixation. Subsequently, she could walk without particular pain. Five months after the operation, she heard the snap of a bone breaking, and had difficulty walking. Plain X-ray revealed a re-fracture of the fracture site and breakage of the plate at the same high position. She underwent re-operation. A valgus osteotomy was performed at an angle of 15°. A reversed condylar LCP was used on the lateral side of the femur. A bone grafting was performed focusing on the fracture site. In addition, a short-LCP was fixed anteriorly to the femur. The bone union 1 year and 6 months postoperatively. She could walk, with no impairment being noted regarding ADL. CONCLUSIONS: We performed osteosynthesis for an IPFF having the characteristics of AFF, but the patient suffered breakage of the plate and re-fracture. Bone union was achieved as a result of re-operation that consisted of valgus osteotomy of the fracture site in combination with autologous bone grafting and double orthogonal plating.

5.
Arthroplasty ; 3(1): 2, 2021 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-35236437

RESUMO

BACKGROUND: Total hip arthroplasty (THA) via the direct anterior approach (DAA) using dual mobility cup (DMC) is considered to effectively prevent postoperative dislocation. However, the dislocation and reduction procedure using a trial implant during the surgery is difficult because of high soft tissue tension. Thereby, leg length discrepancy (LLD) is difficult to assess when using DM via the DAA. PURPOSE: To compare the LLD between cases using conventional SM and those using DMC in THA via the DAA with fluoroscopy. PATIENTS AND METHODS: We retrospectively investigated 34 hips treated with DMC (DMC-DAA group) and 31 hips treated with SM (SM-DAA group). The LLD was defined as the difference in the distance from the teardrop to the medial-most point of the lesser trochanter between the operative and nonoperative sides at immediate postoperative X-ray. RESULTS: The mean LLD in the DMC-DAA group and SM-DAA group was 0.68 ± 7.7 mm and 0.80 ± 5.5, respectively, with no significant difference. The absolute value of the LLD in the DMC-DAA group and SM-DAA group was 6.3 ± 4.4 mm and 5.9 ± 5.5, respectively, with no significant difference. CONCLUSION: Despite the difficulty in assessment of the LLD during THA via the DAA using DMC, this technique does not increase the LLD compared with the use of SM. LEVEL OF EVIDENCE: III, matched case-control study.

6.
SICOT J ; 6: 6, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32068533

RESUMO

INTRODUCTION: Intraoperative fluoroscopy can be easily used because patients are placed in the supine position during total hip arthroplasty via direct anterior approach (DAA-THA) to reduce complications. However, the cumulative level of radiation exposure by intraoperative fluoroscopy increases as the annual number of cases increases, increasing the risk of influencing the health of both the patients and medical workers. The objective of the study was to compare the radiation exposure time of DAA-THA with osteosynthesis and to determine if the level of radiation exposure exceeded safety limits. MATERIAL AND METHODS: DAA-THA was performed in 313 patients between January 2016 and July 2018 and 60 patients with proximal femoral fracture were treated with osteosynthesis. The intraoperative fluoroscopy time was retrospectively surveyed and compared between these two groups. A total of eight surgeons operated DAA-THA employing the same procedure using a traction table. A total of nine surgeons operated osteosynthesis and fluoroscopy was appropriately used during reduction and implant insertion. RESULTS: The mean operative time of DAA-THA was 103.3 min and that of osteosynthesis was 83.3 min, showing a significant difference (p < 0.05). The mean intraoperative fluoroscopy time was 0.83 min (SD ± 0.68) in DAA-THA and 8.91 min (SD ± 8.34) in osteosynthesis showing a significant difference (p < 0.05). CONCLUSIONS: The intraoperative exposure level was significantly lower and the fluoroscopy time was significantly shorter in DAA-THA than in osteosynthesis for proximal femoral fracture. It was clarified that the annual cumulative radiation exposure level in DAA-THA does not exceed the tissue dose limit.

7.
SICOT J ; 6: 2, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31934846

RESUMO

INTRODUCTION: The purpose of this study was to investigate revision with a Kerboull-type plate through the posterior approach (PA) and direct anterior approach (DAA) and compare the clinical outcome. SUBJECTS AND METHODS: Fifty-four patients (56 hip joints) underwent revision surgery in which acetabular reconstruction was performed concomitantly using the Kerboull-type plate and allogeneic bone. Revision surgery through DAA was performed in 21 hip joints and these were compared with 34 hip joints treated through PA. There was no significant difference in the patient demographics between the DAA and PA. RESULTS: There was no significant difference between the operative times in the DAA and PA groups (203.2 ± 43.5 and 211.7 ± 41.8 min). There was a significant difference between the intraoperative blood loss in the DAA and PA groups (503.9 ± 223.7 mL and 703.8 ± 329.6 mL, respectively, p < 0.05). There was no significant difference between the modified Harris Hip Score in the DAA and the PA groups. The loosening of the acetabular component was observed in four cases (11.8%) in the PA group. In the DAA and PA groups, the 5-year survival rates were 100 and 85.7%, respectively. Recurrent dislocation of the hip was observed in six cases (one case in the DAA group (4.8%) and five cases in the PA group (14.7%)). CONCLUSIONS: It was verified that the difference in the surgical approach of acetabular reconstruction concomitantly using the Kerboull-type plate and allogeneic bone graft influenced the postoperative outcome.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...