Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Polymers (Basel) ; 14(19)2022 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-36235945

RESUMO

A novel waste-based plasticizer derived from modified used palm oil (mUPO) was successfully developed and has been used as a new plasticizer to non-glutinous thermoplastic starch foam to improve their properties. The molecular weight and hydroxyl number of the mUPO was 3150 g/mol and 192.19 mgOH/g, respectively. The effects of mUPO content ranging from 0 to 9 phr were investigated. The results revealed that the optimal mUPO content as an additive was 6 wt%. The addition of mUPO had a direct effect on the mechanical properties and thermal properties. The impact strength increased from 1.30 to 4.55 J/m, while the glass transition temperature (Tg) decreased from 70.83 to 66.50 °C by increasing mUPO from 0 phr to 6 phr in the thermoplastic starch foam. The mUPO, on the other hand, has also the potential to reduce shrinkage from 33.91 to 21.77% and moisture absorption from 5.93 to 1.73% by increasing the content from 0 phr to 6 phr in starch foam. Furthermore, the mUPO helps the forming of the foam structure as measured by SEM, and the mUPO utilization of waste-based material could be a promising green alternative plasticizer for starch components, especially starch foam applications.

2.
Mikrochim Acta ; 189(6): 224, 2022 05 18.
Artigo em Inglês | MEDLINE | ID: mdl-35585361

RESUMO

An electrochemical sensor for the determination of artemisinin has been developed based on a glassy carbon electrode modified with hybrid nanocomposites of cobalt phthalocyanine, graphene nanoplatelets, multi-walled carbon nanotubes and ionic liquids (IL). To improve the sensitivity and selectivity of the sensor, cobalt phthalocyanine (CoPc) was used as an effective redox mediator to promote and catalyze the artemisinin reduction. Furthermore, the graphene nanoplatelets and multi-walled carbon nanotubes were used as excellent conducting supporting materials to improve the sensitivity of the electrochemical sensor. Moreover, IL with a surface charge was also employed to prevent aggregation of the graphene nanoplatelets and multi-walled carbon nanotubes. The analytical signal was generated from the reduction of Co(III)Pc generated by artemisinin. The proposed electrochemical sensor was applied to the detection of artemisinin using differential pulse voltammetry and provided a signal with wide linearity ranging from 1.5-60 µM and 60-600 µM and a detection limit of 0.70 µM (3SD/m). Furthermore, the proposed sensor displayed good repeatability and reproducibility of 2.9-3.0 and 3.1-4.4% RSD, respectively. Applications of the sensor to drug and plant samples demonstrated accuracy in a range of 105-116% recoveries. In addition, the results were in good agreement with those obtained from the HPLC method as a reference technique. Thus, the proposed electrochemical sensor provides a new alternative platform for sensitive and selective determination of artemisinin in the analysis of pharmaceuticals with good precision and accuracy.


Assuntos
Artemisininas , Grafite , Nanotubos de Carbono , Indóis , Compostos Organometálicos , Reprodutibilidade dos Testes
3.
Talanta ; 142: 35-42, 2015 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-26003689

RESUMO

An amperometric biosensor based on chemisorption of glucose oxidase (GOx) on Au seeds decorated on magnetic core Fe3O4 nanoparticles (Fe3O4@Au) and their immobilization on screen-printed carbon electrode bulk-modified with manganese oxide (SPCE{MnO2}) was designed for the determination of glucose. The Fe3O4@Au/GOx modified SPCE{MnO2} was used in a flow-injection analysis (FIA) arrangement. The experimental conditions were investigated in amperometric mode with the following optimized parameters: flow rate 1.7 mL min(-1), applied potential +0.38 V, phosphate buffer solution (PBS; 0.1 mol L(-1), pH 7.0) as carrier and 3.89 unit mm(-2) enzyme glucose oxidase loading on the active surface of the SPCE. The designed biosensor in FIA arrangement yielded a linear dynamic range for glucose from 0.2 to 9.0 mmol L(-1) with a sensitivity of 2.52 µA mM(-1) cm(-2), a detection limit of 0.1 mmol L(-1) and a quantification limit of 0.3 mmol L(-1). Moreover, a good repeatability of 2.8% (number of measurements n=10) and a sufficient reproducibility of 4.0% (number of sensors n=3) were achieved. It was found that the studied system Fe3O4@Au facilitated not only a simpler enzyme immobilization but also provided wider linear range. The practical application of the proposed biosensor for FIA quantification of glucose was tested in glucose sirup samples, honeys and energy drinks with the results in good accordance with those obtained by an optical glucose meter and with the contents declared by the producers.


Assuntos
Técnicas Biossensoriais , Enzimas Imobilizadas/química , Glucose Oxidase/química , Glucose/análise , Ouro/química , Nanopartículas de Magnetita/química , Eletroquímica , Bebidas Energéticas/análise , Glucose/química , Mel/análise , Peróxido de Hidrogênio/química , Compostos de Manganês/química , Óxidos/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA