Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Chem ; 92(11): 7393-7398, 2020 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-32410446

RESUMO

Although bioluminescent molecular beacons designed around resonance quenchers have shown higher signal-to-noise ratios and increased sensitivity compared with fluorescent beacon systems, bioluminescence quenching is still comparatively inefficient. A more elegant solution to inefficient quenching can be realized by designing a competitive inhibitor that is structurally very similar to the native substrate, resulting in essentially complete substrate exclusion. In this work, we designed a conjugated anti-interferon-γ (IFN-γ) molecular aptamer beacon (MAB) attached to a bioluminescent protein, Gaussia luciferase (GLuc), and an inhibitor molecule with a similar structure to the native substrate coelenterazine. To prove that a MAB can be more sensitive and have a better signal-to-noise ratio, a bioluminescence-based assay was developed against IFN-γ and provided an optimized, physiologically relevant detection limit of 1.0 nM. We believe that this inhibitor approach may provide a simple alternative strategy to standard resonance quenching in the development of high-performance molecular beacon-based biosensing systems.


Assuntos
Aptâmeros de Nucleotídeos/química , Técnicas Biossensoriais , Inibidores Enzimáticos/química , Imidazóis/química , Luciferases/química , Proteínas Luminescentes/química , Pirazinas/química , Animais , Aptâmeros de Nucleotídeos/síntese química , Copépodes/enzimologia , Inibidores Enzimáticos/farmacologia , Imidazóis/farmacologia , Luciferases/antagonistas & inibidores , Luciferases/metabolismo , Medições Luminescentes , Proteínas Luminescentes/antagonistas & inibidores , Proteínas Luminescentes/metabolismo , Modelos Moleculares , Estrutura Molecular , Pirazinas/farmacologia , Razão Sinal-Ruído
2.
Anal Biochem ; 556: 16-22, 2018 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-29920236

RESUMO

DNA biosensors are attractive tools for genetic analysis as there is an increasing need for rapid and low-cost DNA analysis, primarily driven by applications in personalized pharmacogenomics, clinical diagnostics, rapid pathogen detection, food traceability and forensics. A rapid electrochemical genosensor detection methodology exploiting a combination of modified primers for solution-phase isothermal amplification, followed by rapid detection via hybridization on gold electrodes is reported. Modified reverse primers, exploiting a C18 spacer between the primer-binding site and an engineered single stranded tail, are used in a recombinase polymerase amplification reaction to produce an amplicon with a central duplex flanked by two single stranded tails. These tails are designed to be complementary to a gold electrode tethered capture oligo probe as well as a horseradish peroxidase labelled reporter oligo probe. The time required for hybridization of the isothermally generated amplicons with each of the immobilized and reporter probes was optimised to be 2 min, in both cases. The effect of amplification time and the limit of detection were evaluated using these hybridization times for both single stranded and double stranded DNA templates. The best detection limit of 70 fM for a ssDNA template was achieved using 45 min amplification, whilst for a dsDNA template, just 30 min amplification resulted in a slightly lower detection limit of 14 fM, whilst both 20 and 45 min amplification times were observed to provide detection limits of 71 and 72 fM, respectively, but 30 and 45 min amplification resulted in a much higher signal and sensitivity. The genosensor was applied to genomic DNA and real patient and control blood samples for detection of the coeliac disease associated DQB1*02 HLA allele, as a model system, demonstrating the possibility to carry out molecular diagnostics, combining amplification and detection in a rapid and facile manner.


Assuntos
Doença Celíaca/genética , Primers do DNA/genética , Técnicas Eletroquímicas/métodos , Cadeias beta de HLA-DQ/genética , Técnicas de Amplificação de Ácido Nucleico/métodos , Alelos , Humanos
3.
Analyst ; 143(14): 3374-3381, 2018 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-29897056

RESUMO

Here we describe the design of a bioluminescent stem-loop probe for the sensitive detection of HIV-1 spliced RNA. In this study, we employed Gaussia luciferase (GLuc), a bioluminescent protein that has several advantages over other bioluminescent proteins, including smaller size, higher bioluminescent intensity, and chemical and thermal stability. GLuc was chemically conjugated to the DABCYL-modified stem-loop probe (SLP) and was purified with a 2-step process to remove unconjugated GLuc and SLP. The binding of the target RNA to the loop region of the SLP results in the open conformation separating the stem part of SLP. GLuc conjugated to the stem acts as a reporter that produces light by a chemical reaction upon adding its substrate, coelenterazine in the presence of the target, while DABCYL serves as a quencher of bioluminescence in the closed conformation of SLP in the absence of the target. The optimized GLuc based-SLP assay resulted in a signal-to-background ratio of 47, which is the highest reported with bioluminescent SLPs and is significantly higher compared to traditional fluorescence-based SLPs that yield low signal to background ratio. Moreover, the assay showed an excellent selectivity against a single and double mismatched nucleic acid target, low detection limit, and ability to detect spiked HIV-1 RNA in human serum matrix.


Assuntos
HIV-1 , Luciferases/química , Proteínas Luminescentes/química , RNA Viral/análise , Animais , Copépodes/enzimologia , Humanos
4.
Anal Chem ; 89(6): 3378-3385, 2017 03 21.
Artigo em Inglês | MEDLINE | ID: mdl-28211676

RESUMO

Recent understandings in the development and spread of cancer have led to the realization of novel single cell analysis platforms focused on circulating tumor cells (CTCs). A simple, rapid, and inexpensive analytical platform capable of providing genetic information on these rare cells is highly desirable to support clinicians and researchers alike to either support the selection or adjustment of therapy or provide fundamental insights into cell function and cancer progression mechanisms. We report on the genetic profiling of single cancer cells, exploiting a combination of multiplex ligation-dependent probe amplification (MLPA) and electrochemical detection. Cells were isolated using laser capture and lysed, and the mRNA was extracted and transcribed into DNA. Seven markers were amplified by MLPA, which allows for the simultaneous amplification of multiple targets with a single primer pair, using MLPA probes containing unique barcode sequences. Capture probes complementary to each of these barcode sequences were immobilized on a printed circuit board (PCB) manufactured electrode array and exposed to single-stranded MLPA products and subsequently to a single stranded DNA reporter probe bearing a HRP molecule, followed by substrate addition and fast electrochemical pulse amperometric detection. We present a simple, rapid, flexible, and inexpensive approach for the simultaneous quantification of multiple breast cancer related mRNA markers, with single tumor cell sensitivity.


Assuntos
Técnicas Biossensoriais , Neoplasias da Mama/genética , Técnicas Eletroquímicas , Células Neoplásicas Circulantes/patologia , RNA Mensageiro/genética , Análise de Célula Única , Neoplasias da Mama/patologia , Feminino , Perfil Genético , Humanos
5.
Anal Bioanal Chem ; 408(19): 5337-46, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27220524

RESUMO

The interface between the sample and the transducer surface is critical to the performance of a biosensor. In this work, we compared different strategies for covalent self-assembly of antibodies onto bare gold substrates by introducing disulfide groups into the immunoglobulin structure, which acted as anchor molecules able to chemisorb spontaneously onto clean gold surfaces. The disulfide moieties were chemically introduced to the antibody via the primary amines, carboxylic acids, and carbohydrates present in its structure. The site-directed modification via the carbohydrate chains exhibited the best performance in terms of analyte response using a model system for the detection of the stroke marker neuron-specific enolase. SPR measurements clearly showed the potential for creating biologically active densely packed self-assembled monolayers (SAMs) in a one-step protocol compared to both mixed SAMs of alkanethiol compounds and commercial immobilization layers. The ability of the carbohydrate strategy to construct an electrochemical immunosensor was investigated using electrochemical impedance spectroscopy (EIS) and differential pulse voltammetry (DPV) transduction. Graphical Abstract Left: Functionalization strategies of bare gold substrates via direct bio-SAM using disulfide-containing antibody chemically modified via their primary amines (A), carbohydrates (B) and carboxylic acids (C). Right: Dependence of the peak height with NSE concentration at NSE21-CHO modified electrochemical immunosensor. Inset: Logarithmic calibration plot.


Assuntos
Anticorpos/química , Anticorpos/imunologia , Condutometria/instrumentação , Dissulfetos/química , Ouro/química , Imunoensaio/instrumentação , Ressonância de Plasmônio de Superfície/instrumentação , Sítios de Ligação , Técnicas Biossensoriais/instrumentação , Materiais Revestidos Biocompatíveis/síntese química , Desenho de Equipamento , Análise de Falha de Equipamento , Ligação Proteica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Propriedades de Superfície
6.
Biosens Bioelectron ; 73: 64-70, 2015 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-26043316

RESUMO

Direct detection of PCR product via hybridisation assay, would facilitate the development of rapid tools for genetic analysis. Here, a PCR primer designed to generate a PCR amplicon tagged with single stranded DNA tails at each end of the duplex, which can be used for direct hybridisation with a surface immobilised probe and an enzyme labelled reporter probe is presented. Four modified sequence specific primers (SSP) pairs were designed for the selective amplification of coeliac disease associated alleles (DQA1*05, DQB1*02, DQB1*03:02 alleles), and human growth hormone (positive control). Multiplex PCR products were electrochemically detected in less than 5 min at 37 °C via direct hybridisation to short probes immobilised on individual electrodes of a genosensor array, and subsequent hybridisation to an enzyme labelled reporter probe. The developed electrochemical genosensor array exploiting the modified primers for the direct detection of PCR products was applied to the genotyping of real patient samples.


Assuntos
Doença Celíaca/genética , Doença Celíaca/imunologia , Técnicas Eletroquímicas/métodos , Antígenos HLA/genética , Alelos , Sequência de Bases , Técnicas Biossensoriais , Primers do DNA/genética , Técnicas de Genotipagem , Humanos , Dispositivos Lab-On-A-Chip , Reação em Cadeia da Polimerase Multiplex
7.
Electrophoresis ; 36(16): 1920-6, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26031238

RESUMO

Celiac disease is an auto-immune disorder induced by ingestion of gluten in genetically predisposed individuals. Its diagnostics is more accurate using a combination of immunologic and genetic tests to detect of high levels of certain auto-antibodies and the presence human leukocyte antigen HLA-DQ2 or HLA-DQ8 genetic markers. In this work, we report the design and testing of automated microsystems combining sample treatment, storage, fluidic transport, and detection in a single platform able to carry out genetic or serologic analysis for detection of celiac disease markers. These microsystems share a common footprint and many fluidic features and are thus able to perform a complete assay. The microsystem for the genetic assay extracts and amplifies the DNA prior to detection, while the serology microsystem contains a filter and chamber for the generation and subsequent dilution of plasma. The performance of both platforms is demonstrated and compared with reference methods with an excellent correlation, which makes the developed platform amenable for clinical studies.


Assuntos
Biomarcadores/sangue , Doença Celíaca/sangue , Técnicas Eletroquímicas/instrumentação , Técnicas Genéticas/instrumentação , Imunoensaio/instrumentação , Dispositivos Lab-On-A-Chip , Autoanticorpos/sangue , Doença Celíaca/genética , Técnicas Eletroquímicas/métodos , Desenho de Equipamento , Humanos
8.
Anal Biochem ; 474: 66-8, 2015 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-25524618

RESUMO

We report on a simple approach to enhance solid-phase hybridization-based single base mismatch discrimination at high ionic strength based on the deliberate insertion of a natural DNA base mismatch in the surface-tethered probe. A large drop in hybridization signal of single base mismatched alleles using the designed probe as compared with the conventional probe, from 80% to less than 25% of the signal obtained with the fully complementary, non-mutation-containing sequence, when using colorimetric detection was further improved to 20% when using electrochemical detection, attributable to a difference of spacing of immobilized probes. Finally, the designed probe was used for the electrochemical detection of the DQA1*05:05 allele amplified from real human blood samples.


Assuntos
Pareamento Incorreto de Bases/genética , Técnicas Biossensoriais/métodos , DNA/genética , Mutação/genética , Hibridização de Ácido Nucleico/genética , Alelos , Sequência de Bases , Colorimetria , Técnicas Eletroquímicas , Teste de Histocompatibilidade , Humanos , Dados de Sequência Molecular
9.
Anal Bioanal Chem ; 406(12): 2757-69, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24633503

RESUMO

Coeliac disease is a small intestinal disorder, induced by ingestion of gluten in genetically predisposed individuals. Coeliac disease has been strongly linked to human leukocyte antigens (HLA) located on chromosome 6, with almost 100 % of coeliac disease sufferers carrying either a HLA-DQ2 or HLA-DQ8 heterodimer, with the majority carrying HLA-DQ2 encoded by the DQA1*05:01/05:05, DQB1*02:01/02:02 alleles, whereas the remaining carry the HLA-DQ8 encoded by the DQA1*03:01, DQB1*03:02 alleles. In this work, we present the development of a multiplex electrochemical genosensor array of 36 electrodes, housed within a dedicated microfluidic platform and using a total of 10 sequence-specific probes for rapid medium-high resolution HLA-DQ2/DQ8 genotyping. An evaluation of the selectivity of the designed probes was carried out with the target sequences and 44 potentially interfering alleles, including single base mismatch differentiations; good selectivity was demonstrated. The performance of the electrochemical genosensor array was validated, analyzing real human samples for the presence of HLA-DQ2/DQ8 alleles, and compared with those obtained using laboratory-based HLA typing, and an excellent correlation was obtained.


Assuntos
Doença Celíaca/diagnóstico , Doença Celíaca/genética , Técnicas Eletroquímicas/métodos , Antígenos HLA-DQ/genética , Análise em Microsséries/métodos , Alelos , Suscetibilidade a Doenças , Genótipo , Antígenos HLA-DQ/análise , Humanos
10.
Anal Bioanal Chem ; 403(3): 807-19, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22418762

RESUMO

Coeliac disease is an inflammation of the small intestine, occurring in genetically susceptible individuals triggered by the ingestion of gluten. Human Leukocyte Antigens (HLA) DQ2 and DQ8 gene have been identified as key genetic factors in coeliac disease as they are presented in almost 100 % of the patients. These genes are encoded by the combination of certain alleles in the DQA and DQB region of chromosome 6. Specifically, DQA1*05:01 and DQB1*02:01 alleles for serologically defined leukocyte antigen DQ2 cis, DQA1*05:05 and DQB1*02:02 for DQ2 trans and DQA1*03:01 and DQB1*03:02 alleles for the DQ8. Specific identification of these alleles is a challenge due to the high number of alleles that have been identified so far: 46 in the DQA region and 160 in the DQB region (as of IMGT/HLA Database 10/2011 release). In the reported work, the development of a multiplex colorimetric assay for the low to medium HLA typing of the DQ2 and DQ8 genes is presented. The optimisation of probe design and assay conditions, performed by both surface plasmon resonance and enzyme-linked oligonucleotide assay, are reported. Finally, the performances of the developed typing platform were validated by the analysis of real patient samples and HLA typing, compared with those obtained using hospital based typing technology and an excellent correlation obtained.


Assuntos
Doença Celíaca/genética , Técnicas de Genotipagem/métodos , Antígenos HLA-DQ/genética , Alelos , Sequência de Bases , Colorimetria/métodos , Sondas de DNA/genética , Predisposição Genética para Doença , Genótipo , Humanos , Hibridização de Ácido Nucleico/métodos , Sensibilidade e Especificidade , Ressonância de Plasmônio de Superfície
11.
Anal Bioanal Chem ; 402(3): 1001-9, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22086396

RESUMO

Coeliac disease is an inflammation of the small intestine triggered by gluten ingestion. We present a fluorescent genosensor, exploiting molecular-beacon-functionalized gold nanoparticles, for the identification of human leukocyte antigen (HLA) DQ2 gene, a key genetic factor in coeliac disease. Optimization of sensor performance was achieved by tuning the composition of the oligonucleotide monolayer immobilized on the gold nanoparticle and the molecular beacon design. Co-immobilization of the molecular beacon with a spacing oligonucleotide (thiolated ten-thymine oligonucleotide) in the presence of ten-adenine oligonucleotides resulted in a significant increase of the sensor response owing to improved spacing of the molecular beacons and extension of the distance from the nanoparticle surface, which renders them more available for recognition. Further increase in the response (approximately 40%) was shown to be achievable when the recognition sequence of the molecular beacon was incorporated in the stem. Improvement of the specificity of the molecular beacons was also achieved by the incorporation within their recognition sequence of a one-base mismatch. Finally, gold nanoparticles functionalized with two molecular beacons targeting the DQA1*05* and DQB1*02* alleles allowed the low-resolution typing of the DQ2 gene at the nanomolar level.


Assuntos
Corantes Fluorescentes/química , Ouro/química , Antígenos HLA-DQ/genética , Nanopartículas/química , Oligonucleotídeos/química , Sequência de Bases , Calibragem , Doença Celíaca/genética , Genótipo , Humanos , Nanopartículas/ultraestrutura , Sensibilidade e Especificidade , Espectrometria de Fluorescência/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...