1.
Sleep ; 26(3): 337-41, 2003 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-12749556

RESUMO

Actigraphy is a method used to study sleep-wake patterns and circadian rhythms by assessing movement, most commonly of the wrist. These evidence-based practice parameters are an update to the Practice Parameters for the Use of Actigraphy in the Clinical Assessment of Sleep Disorders, published in 1995. These practice parameters were developed by the Standards of Practice Committee and reviewed and approved by the Board of Directors of the American Academy of Sleep Medicine. Recommendations are based on the accompanying comprehensive review of the medical literature regarding the role of actigraphy, which was developed by a task force commissioned by the American Academy of Sleep Medicine. The following recommendations serve as a guide to the appropriate use of actigraphy. Actigraphy is reliable and valid for detecting sleep in normal, healthy populations, but less reliable for detecting disturbed sleep. Although actigraphy is not indicated for the routine diagnosis, assessment, or management of any of the sleep disorders, it may serve as a useful adjunct to routine clinical evaluation of insomnia, circadian-rhythm disorders, and excessive sleepiness, and may be helpful in the assessment of specific aspects of some disorders, such as insomnia and restless legs syndrome/periodic limb movement disorder. The assessment of daytime sleepiness, the demonstration of multiday human-rest activity patterns, and the estimation of sleep-wake patterns are potential uses of actigraphy in clinical situations where other techniques cannot provide similar information (e.g., psychiatric ward patients). Superiority of actigraphy placement on different parts of the body is not currently established. Actigraphy may be useful in characterizing and monitoring circadian rhythm patterns or disturbances in certain special populations (e.g., children, demented individuals), and appears useful as an outcome measure in certain applications and populations. Although actigraphy may be a useful adjunct to portable sleep apnea testing, the use of actigraphy alone in the detection of sleep apnea is not currently established. Specific technical recommendations are discussed, such as using concomitant completion of a sleep log for artifact rejection and timing of lights out and on; conducting actigraphy studies for a minimum of three consecutive 24-hour periods; requiring raw data inspection; permitting some preprocessing of movement counts; stating that epoch lengths up to 1 minute are usually sufficient, except for circadian rhythm assessment; requiring interpretation to be performed manually by visual inspection; and allowing automatic scoring in addition to manual scoring methods.


Assuntos
Ritmo Circadiano/fisiologia , Transtornos do Sono do Ritmo Circadiano/diagnóstico , Sono/fisiologia , Distúrbios do Sono por Sonolência Excessiva/diagnóstico , Humanos , Monitorização Fisiológica/instrumentação , Síndrome da Mioclonia Noturna/diagnóstico , Descanso
2.
Sleep ; 25(2): 143-7, 2002 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-11902424

RESUMO

Continuous positive airway pressure (CPAP) is used to treat patients with the obstructive sleep apnea syndrome (OSAS). The current standard is for an attendant technician to titrate CPAP during full polysomnography to obtain a fixed single pressure. The patient uses CPAP nightly at this fixed single pressure. Recently, devices using new technology that automatically titrate positive airway pressure (APAP) have become available. Such devices continually adjust pressure, as needed, to maintain airway patency (APAP titration). These adjustments can be made with or without attendant technician intervention. Data obtained during APAP titration can be used to provide a fixed single pressure for subsequent treatment. Alternatively, APAP devices can be used in self-adjusting mode for treatment (APAP treatment). A task force of the Standards of Practice Committee of the American Academy of Sleep Medicine reviewed the available literature. Based on this review, the Standards of Practice Committee developed these practice parameters as a guide to the appropriate use of APAP. Recommendations are as follows: 1) A diagnosis of OSAS must be established by an acceptable method. 2) APAP titration and APAP treatment are not currently recommended for patients with congestive heart failure, significant lung disease (e.g., chronic obstructive pulmonary disease), daytime hypoxemia and respiratory failure from any cause, or prominent nocturnal desaturation other than from OSA (e.g., obesity hypoventilation syndrome). In addition, patients who do not snore (either due to palate surgery or naturally) should not be titrated with an APAP device that relies on vibration or sound in the device's algorithm. 3) APAP devices are not currently recommended for split-night studies since none of the reviewed research studies examined this issue. 4) Certain APAP devices may be used during attended titration to identify by polysomnography a single pressure for use with standard CPAP for treatment of OSA. 5) Once an initial successful attended CPAP or APAP titration has been determined by polysomnography, certain APAP devices may be used in the self-adjusting mode for unattended treatment of patients with OSA. 6) Use of unattended APAP to either initially determine pressures for fixed CPAP or for self-adjusting APAP treatment in CPAP naïve patients is not currently established. 7) Patients being treated with fixed CPAP on the basis of APAP titration or being treated with APAP must be followed to determine treatment effectiveness and safety, and 8) a re-evaluation and, if necessary, a standard attended CPAP titration should be performed if symptoms do not resolve or the CPAP or APAP treatment otherwise appears to lack efficacy.


Assuntos
Respiração com Pressão Positiva/instrumentação , Respiração com Pressão Positiva/normas , Apneia Obstrutiva do Sono/terapia , Sono REM/fisiologia , Desenho de Equipamento , Falha de Equipamento , Humanos , Polissonografia , Apneia Obstrutiva do Sono/diagnóstico