Resultados 1 - 16 de 16
Filtrar
1.
Phys Med Biol ; 62(17): 6980-6992, 2017 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-28791963

RESUMO

Restrictions on human exposure to electromagnetic waves at frequencies higher than 3-10 GHz are defined in terms of the incident power density to prevent excessive temperature rise in superficial tissue. However, international standards and guidelines differ in their definitions of how the power density is interpreted for brief exposures. This study investigated how the temperature rise was affected by exposure duration at frequencies higher than 6 GHz. Far-field exposure of the human face to pulses shorter than 10 s at frequencies from 6 to 100 GHz was modelled using the finite-difference time-domain method. The bioheat transfer equation was used for thermal modelling. We investigated the effects of frequency, polarization, exposure duration, and depth below the skin surface on the temperature rise. The results indicated limitations in the current human exposure guidelines and showed that radiant exposure, i.e. energy absorption per unit area, can be used to limit temperature rise for pulsed exposure. The data are useful for the development of human exposure guidelines at frequencies higher than 6 GHz.


Assuntos
Temperatura Corporal/efeitos da radiação , Campos Eletromagnéticos , Face/efeitos da radiação , Modelos Anatômicos , Humanos , Doses de Radiação
2.
Phys Med Biol ; 62(8): 3124-3138, 2017 04 21.
Artigo em Inglês | MEDLINE | ID: mdl-28176675

RESUMO

Incident power density is used as the dosimetric quantity to specify the restrictions on human exposure to electromagnetic fields at frequencies above 3 or 10 GHz in order to prevent excessive temperature elevation at the body surface. However, international standards and guidelines have different definitions for the size of the area over which the power density should be averaged. This study reports computational evaluation of the relationship between the size of the area over which incident power density is averaged and the local peak temperature elevation in a multi-layer model simulating a human body. Three wave sources are considered in the frequency range from 3 to 300 GHz: an ideal beam, a half-wave dipole antenna, and an antenna array. 1D analysis shows that averaging area of 20 mm × 20 mm is a good measure to correlate with the local peak temperature elevation when the field distribution is nearly uniform in that area. The averaging area is different from recommendations in the current international standards/guidelines, and not dependent on the frequency. For a non-uniform field distribution, such as a beam with small diameter, the incident power density should be compensated by multiplying a factor that can be derived from the ratio of the effective beam area to the averaging area. The findings in the present study suggest that the relationship obtained using the 1D approximation is applicable for deriving the relationship between the incident power density and the local temperature elevation.


Assuntos
Campos Eletromagnéticos/efeitos adversos , Doses de Radiação , Algoritmos , Humanos
3.
Bioelectromagnetics ; 37(6): 409-22, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27243146

RESUMO

Movement of a body in a static magnetic field gives rise to the Lorentz force that induces in the medium both electric currents and dielectric polarization. It is usually assumed that the conductivity of biological tissues is sufficiently high in order to neglect dielectric phenomenon arising from non-equilibrium of polarization charges. However, the permittivity of biological tissues is extremely high and the relaxation time of free charges is relatively low. In this study, we examined the effect of dielectric polarization on the electric field (EF) induced by human movements in a strong magnetic field (MF). Analytic equations for brain and bone equivalent spheres translating and rotating in a uniform MF were derived from Maxwell equations. Several examples were computed by using Fast Fourier Transform to examine transient dielectric effects in a time domain. The results showed that dielectric polarization transients do arise, but in the case of homogeneous medium, they are vanishingly small. In contrast, the local dielectric transients are not vanishingly small in heterogeneous medium. However, due to limited acceleration and deceleration of normal human movements, the transients are relatively small, at maximum a few dozen percent of the EF induced by the change of the magnetic flux. Taking into account the high uncertainty in numerical simulation, the dielectric transients can be neglected in the case of biological materials but not in the case of many non-biological materials of low conductivity. Bioelectromagnetics. 37:409-422, 2016. © 2016 Wiley Periodicals, Inc.


Assuntos
Cabeça , Campos Magnéticos , Movimento , Impedância Elétrica , Humanos , Modelos Biológicos , Rotação
4.
Bioelectromagnetics ; 35(4): 245-50, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24615825

RESUMO

Cashiers are potentially exposed to intermediate frequency (IF) magnetic fields at their workplaces because of the electronic article surveillance (EAS) systems used in stores to protect merchandise against theft. This study aimed at investigating occupational exposure of cashiers to IF magnetic fields in Finnish stores. Exposure to extremely low frequency (ELF) magnetic fields was also evaluated because cashiers work near various devices operating with 50 Hz electric power. The peak magnetic flux density was measured for IF magnetic fields, and was found to vary from 0.2 to 4 µT at the cashier's seat. ELF magnetic fields from 0.03 to 4.5 µT were found at the cashier's seat. These values are much lower than exposure limits. However, according to the International Commission on Non-Ionizing Radiation Protection (ICNIRP) occupational reference levels for IF magnetic fields (141 µT for the peak field) were exceeded in some cases (maximum 189 µT) for short periods of time when cashiers walked through the EAS gates. As the ICNIRP reference levels do not define any minimum time for exposure, additional investigations are recommended to determine compliance with basic restrictions. Even if the basic restrictions are not exceeded, persons working near EAS devices represent an exceptional group of workers with respect to exposure to electromagnetic fields. This group could serve as a basis for epidemiological studies addressing possible health effects of IF magnetic fields. Compliance with the reference levels for IF fields was evaluated using both broadband measurement of peak fields and the ICNIRP summation rule for multiple frequencies. The latter was generally more conservative, and the difference between the two methods was large (>10-fold) for EAS systems using a 58 kHz signal with complex waveform. This indicates that the ICNIRP multiple frequency rule can be unnecessarily conservative when measuring complex waveforms.


Assuntos
Campos Eletromagnéticos/efeitos adversos , Exposição Ocupacional , Comércio , Exposição Ambiental , Humanos , Campos Magnéticos/efeitos adversos
5.
Phys Med Biol ; 58(8): 2625-40, 2013 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-23552657

RESUMO

Medical staff working near magnetic resonance imaging (MRI) scanners are exposed both to the static magnetic field itself and also to electric currents that are induced in the body when the body moves in the magnetic field. However, there are currently limited data available on the induced electric field for realistic movements. This study computationally investigates the movement induced electric fields for realistic movements in the magnetic field of a 3 T MRI scanner. The path of movement near the MRI scanner is based on magnetic field measurements using a coil sensor attached to a human volunteer. Utilizing realistic models for both the motion of the head and the magnetic field of the MRI scanner, the induced fields are computationally determined using the finite-element method for five high-resolution numerical anatomical models. The results show that the time-derivative of the magnetic flux density (dB/dt) is approximately linearly proportional to the induced electric field in the head, independent of the position of the head with respect to the magnet. This supports the use of dB/dt measurements for occupational exposure assessment. For the path of movement considered herein, the spatial maximum of the induced electric field is close to the basic restriction for the peripheral nervous system and exceeds the basic restriction for the central nervous system in the international guidelines. The 99th percentile electric field is a considerably less restrictive metric for the exposure than the spatial maximum electric field; the former is typically 60-70% lower than the latter. However, the 99th percentile electric field may exceed the basic restriction for dB/dt values that can be encountered during tasks commonly performed by MRI workers. It is also shown that the movement-induced eddy currents may reach magnitudes that could electrically stimulate the vestibular system, which could play a significant role in the generation of vertigo-like sensations reported by people moving in a strong static magnetic field.


Assuntos
Eletricidade , Imageamento por Ressonância Magnética/instrumentação , Modelos Anatômicos , Movimento , Exposição Ocupacional/análise , Adulto , Feminino , Humanos , Imageamento por Ressonância Magnética/efeitos adversos , Masculino , Incerteza , Vertigem/etiologia
6.
Duodecim ; 127(17): 1788-96, 2011.
Artigo em Finlandês | MEDLINE | ID: mdl-21995116

RESUMO

The mobile phones radiate electromagnetic energy which is partly absorbed into the tissues in the vicinity of the phone. The minor heating, in maximum up to 0.3 degrees C, may cause some alterations in the expression of genes and proteins similar to physiological response to other stimuli. Biophysical studies at the cellular and molecular level have not revealed any well established interaction mechanism, through which mobile phone radiation could induce toxic effects below the thermal effect level. Research results on various biological effects in vitro and in vivo are continuously published but there is no consistent evidence on well established harmful effects. The mobile phone radiation is not carcinogenic for experimental animals or genotoxic for cells. According to epidemiological studies and psychophysiological brain function studies the use of mobile phones does not seem to increase the risk of tumors in the head and brain or disturb the function of central nervous system. However, there is a need for more research on the long-term effects of mobile phone radiation particularly on children.


Assuntos
Telefone Celular , Encéfalo/efeitos da radiação , Expressão Gênica/efeitos da radiação , Nível de Saúde , Humanos , Radiação , Medição de Risco
7.
Health Phys ; 100(6): 641-53, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22004933

RESUMO

Movement in a strong static magnetic field induces electric fields in a human body, which may result in various sensory perceptions such as vertigo, nausea, magnetic phosphenes, and a metallic taste in the mouth. These sensory perceptions have been observed by patients and medical staff in the vicinity of modern diagnostic magnetic resonance (MR) equipment and may be distracting if they were to affect the balance and eye-hand coordination of, for example, a physician carrying out a medical operation during MR scanning. The stimulation of peripheral nerve tissue by a more intense induced electric field is also theoretically possible but has not been reported to result from such movement. The main objective of this study is to consider generic criteria for limiting the slowly varying broadband (<10 Hz) electric fields induced by the motion of the body in the static magnetic field. In order to find a link between the static magnetic flux density and the time-varying induced electric field, the static magnetic field is converted to the homogeneous equivalent transient and sinusoidal magnetic fields exposing a stationary body. Two cases are considered: a human head moving in a non-uniform magnetic field and a head rotating in a homogeneous magnetic field. Then the electric field is derived from the magnetic flux rate (dB/dt) of the equivalent field by using computational dosimetric data published in the literature for various models of the human body. This conversion allows the plotting of the threshold electric field as a function of frequency for vertigo, phosphenes, and stimulation of peripheral nerves. The main conclusions of the study are: The basic restrictions for limiting exposure to extremely low frequency magnetic fields recommended by the International Commission on Non-Ionizing Radiation Protection ICNIRP in 1998 will prevent most cases of vertigo and other sensory perceptions that result from induced electric fields above 1 Hz, while limiting the static magnetic field below 2 T, as recently recommended by ICNIRP, provides sufficient protection below 1 Hz. People can experience vertigo when moving in static magnetic fields of between 2 and 8 T, but this may be controlled to some extent by slowing down head and/or body movement. In addition, limiting the static magnetic field below 8 T provides good protection against peripheral nerve stimulation.


Assuntos
Campos Eletromagnéticos/efeitos adversos , Campos Magnéticos/efeitos adversos , Movimento , Doses de Radiação , Humanos , Nervos Periféricos/fisiologia , Proteção Radiológica , Rotação , Vertigem/etiologia
8.
Phys Med Biol ; 54(7): 2243-57, 2009 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-19293469

RESUMO

Recent advances in magnetic resonance imaging (MRI) have increased occupational exposure to magnetic fields. In this study, we examined the assessment of occupational exposure to gradient magnetic fields and time-varying magnetic fields generated by motion in non-homogeneous static magnetic fields of MRI scanners. These magnetic field components can be measured simultaneously with an induction coil setup that detects the time rate of change of magnetic flux density (dB/dt). The setup developed was used to measure the field components around two MRI units (1 T open and 3 T conventional). The measured values can be compared with dB/dt reference levels derived from magnetic flux density reference levels given by the International Commission on Non-Ionizing Radiation Protection (ICNIRP). The measured motion-induced dB/dt values were above the dB/dt reference levels for both MRI units. The measured values for the gradient fields (echo planar imaging (EPI) and fast field echo (FFE) sequences) also exceeded the dB/dt reference levels in positions where the medical staff may have access during interventional procedures. The highest motion-induced dB/dt values were 0.7 T s(-1) for the 1 T scanner and 3 T s(-1) for the 3 T scanner when only the static field was present. Even higher values (6.5 T s(-1)) were measured for simultaneous exposure to motion-induced and gradient fields in the vicinity of the 3 T scanner.


Assuntos
Imageamento por Ressonância Magnética/efeitos adversos , Imageamento por Ressonância Magnética/instrumentação , Magnetismo , Exposição Ocupacional , Estudos de Viabilidade , Humanos , Movimento , Fatores de Tempo
9.
Bioelectromagnetics ; 30(4): 307-12, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19194889

RESUMO

In this article, the exposure to radio frequency electromagnetic fields was studied in close proximity (distances of 10, 100, 300, and 600 mm) to six base station antennas. The specific absorption rate (SAR) in 800 mm x 500 mm x 200 mm box phantom as well as unperturbed electric field (E) in air was measured. The results were used to determine whether the measurement of local maximum of unperturbed electric field can be used as a compliance check for local exposure. Also, the conservativeness of this assessment method compared to the ICNIRP basic restriction was studied. Moreover, the assessment of whole-body exposure was discussed and the distance ranges presented in which the ICNIRP limit for local exposure could be exceeded before the limit for whole-body SAR. These results show that the electric field measurement alone can be used for easy compliance check for the local exposure at all distances and for all antenna types studied. However, in some cases when the local peak value of E was compared directly to the ICNIRP reference level for unperturbed E, the exposure was overestimated only very slightly (by factor 1.1) compared to the basic restriction for localized SAR in a human, and hence these results can not be generalized to all antenna types. Moreover, it was shown that the limit for localized exposure could be exceeded before the limit for the whole-body average SAR, if the distance to the antenna was less than 240 mm.


Assuntos
Telefone Celular , Campos Eletromagnéticos , Monitoramento de Radiação/métodos , Exposição Ambiental , Finlândia , Humanos , Ondas de Rádio
10.
Bioelectromagnetics ; 30(2): 120-8, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18803252

RESUMO

The aim of this study was to design, implement and analyze a space-efficient setup for the whole-body exposure of unrestrained Wistar rats to radiofrequency (RF) electromagnetic fields at 900 MHz. The setup was used for 2 years in a cocarcinogenesis study and part of it for 5 weeks in a central nervous system (CNS) study. Up to 216 rats could be placed in separate cages in nine different exposure chambers on three racks requiring only 9 m2 of floor area (24 rats per m2). Chambers were radial transmission lines (RTL), where the rats could freely move in their cages where food and drinking water was provided ad libitum except during RF exposure periods. Dosimetrical analysis was based on FDTD computations with heterogeneous rat models and was validated with calorimetrical measurements carried out with homogeneous phantoms. The estimated whole-body average specific absorption rates (SAR) of rats were 0 (sham), 0.4, and 1.3 W/kg in the cocarcinogenesis study and 0 (sham), 0.27, and 2.7 W/kg in the CNS study with an estimated uncertainty of 3 dB (K = 2). The instantaneous and lifetime variations of whole-body average SAR due to the movement of rats were estimated to be 2.3 and 1.3 dB (K = 1), respectively.


Assuntos
Campos Eletromagnéticos , Animais , Modelos Teóricos , Ratos , Ratos Wistar , Incerteza
11.
Bioelectromagnetics ; 29(5): 363-70, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-18247366

RESUMO

The aim of this study was a dosimetrical analysis of the setup used in the exposure of the heads of domestic pigs to GSM-modulated radio frequency electromagnetic fields (RF-EMF) at 900 MHz. The heads of pigs were irradiated with a half wave dipole using three different exposure routines; short bursts of 1-3 s at two different exposure levels and a continuous 10-min exposure. The electroencephalogram (EEG) was registered continuously during the exposures to search for RF-EMF originated changes. The dosimetry was based on simulations with the anatomical heterogeneous numerical model of the pig head. The simulation results were validated by experimental measurements with the exposure dipole and a homogeneous liquid phantom resembling the pig head. The specific absorption rate (SAR), defined as a maximum average over 10 g tissue mass (SAR(10g)), was 7.3 W/kg for the first set of short bursts and 31 W/kg for the second set of short bursts. The SAR(10g) in the continuous 10-min exposure was 31 W/kg. The estimated uncertainty for the dosimetry was +/-25% (K = 2).


Assuntos
Telefone Celular , Exposição Ambiental , Cabeça/fisiologia , Cabeça/efeitos da radiação , Micro-Ondas , Radiometria/instrumentação , Anestesia , Animais , Desenho de Equipamento , Análise de Falha de Equipamento , Radiometria/métodos , Suínos
12.
Health Phys ; 94(2): 161-9, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18188050

RESUMO

Operators of industrial high-frequency dielectric heaters are exposed to electromagnetic fields that are high enough to significantly increase body temperature. The assessment of exposure based on the measurement of external field strengths is, however, inaccurate due to the non-uniformity of the fields. This paper presents an exposure assessment method based on the measurement of the current induced by the external electric field in the body of the operator. Body current distributions were measured at 27.12 MHz using various current meters under a condition simulating the exposure to stray fields emitted by a dielectric heater. The specific absorption rates and induced body currents were computed with the finite-difference time-domain method using heterogeneous and homogeneous human models. The numerical analysis indicated that the basic restrictions for occupational exposure are not exceeded when the current induced in the limbs is lower than the action level (100 mA), even though the maximum electric field significantly exceeds the action value (61 V m(-1)). For the heterogeneous human model the exposure limit for local specific absorption rate was exceeded when the current induced in the ankle was 166 mA at a distance of 0.3 m from the electrode of the device. The vertical component of current density proved to be much more significant than the horizontal components. The importance of the horizontal components was highest near the electrode. The computations showed no concentration of the induced current to the superficial tissues due to the skin effect.


Assuntos
Eletricidade , Campos Eletromagnéticos , Monitoramento de Radiação/métodos , Carga Corporal (Radioterapia) , Estatura , Peso Corporal , Exposição Ambiental , Temperatura Alta , Utensílios Domésticos , Humanos , Modelos Biológicos , Imagens de Fantasmas , Doses de Radiação
13.
Bioelectromagnetics ; 29(3): 207-12, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18044739

RESUMO

The aim of this study was a dosimetrical analysis of an experimental setup used in the exposure of 10 female volunteers to GSM 900 radiation. The exposure was carried out by irradiating a small region of the right forearms of the volunteers for 1 h, after which biopsies were taken from the exposed skin for protein analysis. The source of irradiation was a half-wave dipole fed with a computer controlled GSM phone. The specific absorption rate (SAR) induced in the skin biopsy was assessed by computer simulations. The numerical model of the arm consisted of a muscle tissue simulating cylinder covered with thin skin (1 mm) and fat (3 mm) layers. The simulation models were validated by measurements with a homogeneous cylindrical liquid phantom. The average SAR value in the biopsy was 1.3 W/kg and the estimated uncertainty +/-20% (K = 2). The main source of error was found to be variations in the distance of the forearm from the dipole (10 +/- 1 mm). Other significant sources of uncertainty are individual variations of the fat layer and arm thicknesses, and the uncertainty of radio frequency (RF) power measurement.


Assuntos
Telefone Celular , Fenômenos Eletromagnéticos/instrumentação , Micro-Ondas , Radiobiologia/instrumentação , Radiometria/instrumentação , Pesquisa/instrumentação , Fenômenos Fisiológicos da Pele/efeitos da radiação , Carga Corporal (Radioterapia) , Fenômenos Eletromagnéticos/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Doses de Radiação , Radiobiologia/métodos , Radiometria/métodos , Eficiência Biológica Relativa , Reprodutibilidade dos Testes , Projetos de Pesquisa , Sensibilidade e Especificidade
14.
Health Phys ; 92(6): 531-40, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17495653

RESUMO

Assessment of exposure to time varying electric and magnetic fields is difficult when the fields are non-uniform or very localized. Restriction of the local spatial peak value below the reference level may be too restrictive. Additional problems arise when the fields are not sinusoidal. The objective of this review is to present practical measurement procedures for realistic and not too conservative exposure assessment for verification of compliance with the exposure guidelines of ICNIRP. In most exposure situations above 10 MHz the electric field (E) is more important than the magnetic field (B). At frequencies above 500 MHz the equivalent electric field power density averaged over the body is the most relevant indicator of exposure. Assessment of specific absorption rate (SAR) is not needed when the spatial peak value does not exceed by 6 dB the average value. Below 50 MHz down to 50 Hz, the electric field induces currents flowing along the limbs and torso. The current is roughly directly proportional to the electric field strength averaged over the body. A convenient way to restrict current concentration and hot spots in the neck, ankle and wrist, is to measure the current induced in the body. This is not possible for magnetic fields. Instead, for a non-uniform magnetic field below 100 kHz the average magnetic flux density over the whole body and head are valid exposure indicators to protect the central nervous system. The first alternative to analyze exposure to non-sinusoidal magnetic fields below 100 kHz is based on the spectral comparison of each component to the corresponding reference level. In the second alternative the waveform of B or dB/dt is filtered in the time domain with a simple filter, where the attenuation varies proportionally to the reference level as a function of frequency, and the filtered peak value is compared to the peak reference level derived from the ICNIRP reference levels.


Assuntos
Campos Eletromagnéticos , Exposição Ambiental/análise , Modelos Biológicos , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Contagem Corporal Total/normas , Carga Corporal (Radioterapia) , Humanos , Doses de Radiação , Eficiência Biológica Relativa , Espalhamento de Radiação , Contagem Corporal Total/métodos
15.
Photochem Photobiol ; 81(2): 333-41, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15623317

RESUMO

The suitability of a new technology single-monochromator diode array spectroradiometer for UV-radiation safety measurements, in particular for sunbed measurements, was evaluated. The linearity, cosine response, temperature response, wavelength scale, stray-light and slit function of the spectroradiometer were determined and their effects on the measurement accuracy evaluated. The main error sources were stray-light and nonideal cosine response, for which correction methods are presented. Without correction, the stray-light may reduce the accuracy of the measurement excessively, particularly in the UV-B range. The expanded uncertainty of the corrected UV measurements is estimated to be 14%, which is confirmed with the comparative measurements carried out with a well-characterized double-monochromator spectroradiometer. The measurement accuracy is sufficient for sunbed measurements, provided that all corrections described above have been done and the user of the instrument has a good understanding of the instrument's operating principles and potential error sources. If these requirements are met, the tested spectroradiometer improves and facilitates market surveillance field measurements of sunbeds.


Assuntos
Monitoramento de Radiação/instrumentação , Radiometria/instrumentação , Espectrofotometria Ultravioleta/instrumentação , Raios Ultravioleta , Calibragem , Desenho de Equipamento , Estudos de Avaliação como Assunto , Monitoramento de Radiação/métodos , Radiometria/métodos , Sensibilidade e Especificidade , Espectrofotometria Ultravioleta/métodos , Temperatura
16.
Health Phys ; 86(1): 56-66, 2004 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-14695008

RESUMO

Hand-held digital mobile phones generate pulsed magnetic fields associated with the battery current. The peak value and the waveform of the battery current were measured for seven different models of digital mobile phones, and the results were applied to compute approximately the magnetic flux density and induced currents in the phone-user's head. A simple circular loop model was used for the magnetic field source and a homogeneous sphere consisting of average brain tissue equivalent material simulated the head. The broadband magnetic flux density and the maximal induced current density were compared with the guidelines of ICNIRP using two various approaches. In the first approach the relative exposure was determined separately at each frequency and the exposure ratios were summed to obtain the total exposure (multiple-frequency rule). In the second approach the waveform was weighted in the time domain with a simple low-pass RC filter and the peak value was divided by a peak limit, both derived from the guidelines (weighted peak approach). With the maximum transmitting power (2 W) the measured peak current varied from 1 to 2.7 A. The ICNIRP exposure ratio based on the current density varied from 0.04 to 0.14 for the weighted peak approach and from 0.08 to 0.27 for the multiple-frequency rule. The latter values are considerably greater than the corresponding exposure ratios 0.005 (min) to 0.013 (max) obtained by applying the evaluation based on frequency components presented by the new IEEE standard. Hence, the exposure does not seem to exceed the guidelines. The computed peak magnetic flux density exceeded substantially the derived peak reference level of ICNIRP, but it should be noted that in a near-field exposure the external field strengths are not valid indicators of exposure. Currently, no biological data exist to give a reason for concern about the health effects of magnetic field pulses from mobile phones.


Assuntos
Encéfalo/fisiologia , Telefone Celular , Fontes de Energia Elétrica , Exposição Ambiental/análise , Cabeça/fisiologia , Modelos Biológicos , Radiação , Radiometria/métodos , Medição de Risco/métodos , Simulação por Computador , Exposição Ambiental/normas , Humanos , Modelos Neurológicos , Doses de Radiação , Radiometria/instrumentação