Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 77
Filtrar
1.
Circ Cardiovasc Interv ; : e013729, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38666384

RESUMO

BACKGROUND: Transverse aortic arch obstruction is a challenging lesion for which stent implantation provides a potentially important alternate therapy. The objectives were to evaluate the technical, procedural, and medium-to-long-term clinical outcomes of percutaneous stent implantation of transverse aortic arch obstruction. METHODS: This is a retrospective, multicenter study of transverse aortic arch stent implantation. Univariable and multivariable analyses were performed. RESULTS: Index catheterization included 187 stent implants in 146 patients. The median age is 14.3 years (interquartile range, 9.3-19), weight is 53 kg (30-69), and follow-up is 53 months (12-120). The most common stent design was open cell (n=90, 48%). Stents overlapped 142 arch vessels (37 carotid arteries) in 118 (81%) cases. Technical and procedural success rates were 100% and 88%, respectively. Lower weight (P=0.018), body surface area (P=0.013), and minimum-to-descending aortic diameter ratio (P<0.001) were associated with higher baseline aortic gradient. The residual gradient was inversely associated with implant and final dilation diameters (P<0.001). The combined incidence of aortic injury and stent-related complications was 14%. There were no reports of abnormal brain scans or stroke. Blood pressure cuff gradient, echocardiographic arch velocity, and hypertension rates improved within 1-year follow-up with increased antihypertensive medication use. Reintervention was reported in 60 (41%) patients at a median of 84 (22-148) months to first reintervention. On multivariable logistic regression, residual aortic gradient >10 mm Hg was associated with increased odds of reintervention at all time points when controlling for each final dilation diameter, weight, and minimum-to-descending aortic diameter ratio. CONCLUSIONS: Transverse aortic arch stent implantation has high rates of technical, procedural, and medium-to-long-term clinical success. Aortic gradient >10 mm Hg is associated with increased odds of reintervention at 1-year and most recent follow-ups. Open cell stent design was frequently used for its advantages in conformability, perfusion of arch vessels, low fracture rate, and the ability to perform effective angioplasty of side cells.

2.
JACC Cardiovasc Interv ; 17(2): 231-244, 2024 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-38267137

RESUMO

BACKGROUND: Transcatheter pulmonary valve replacement (TPVR) has expanded and evolved since its initial commercial approval in the United States in 2010. OBJECTIVES: This study sought to characterize real-world practice, including patient selection, procedural outcomes, complications, and off-label usage. METHODS: Characteristics and outcomes for patients undergoing balloon-expandable TPVR were collected from the American College of Cardiology National Cardiovascular Data Registry IMPACT (Improving Pediatric and Adult Congenital Treatment) Registry. RESULTS: Between April 2016 and March 2021, 4,513 TPVR procedures were performed in patients with a median age of 19 years, 57% with a Melody (Medtronic Inc) and 43% with a SAPIEN (Edwards Lifesciences) valve. Most implanting centers performed <10 cases annually. One-third of transcatheter pulmonary valve implants were into homograft conduits, one-third were into bioprosthetic valves (BPVs), 25% were in native or patched right ventricular outflow tracts (RVOTs), and 6% were into Contegra (Medtronic Inc) conduits. Over the course of the study period, SAPIEN valve use grew from ∼25% to 60%, in large part because of implants in patients with a native/patched RVOT. Acute success was achieved in 95% of patients (95.7% in homografts, 96.2% in BPVs, 94.2% in native RVOTs, and 95.4% in Contegra conduits). Major adverse events occurred in 2.4% of procedures, more commonly in patients with a homograft (2.9%) or native RVOT (3.4%) than a prior BPV (1.4%; P = 0.004). CONCLUSIONS: This study describes novel population data on the use and procedural outcomes of TPVR with balloon-expandable valves. Over time, there has been increasing use of TPVR to treat regurgitant native RVOT anatomy, with the SAPIEN valve more commonly used for this application.


Assuntos
Próteses Valvulares Cardíacas , Valva Pulmonar , Substituição da Valva Aórtica Transcateter , Adulto , Humanos , Criança , Adulto Jovem , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Resultado do Tratamento , Sistema de Registros
3.
JACC Cardiovasc Interv ; 16(15): 1917-1928, 2023 08 14.
Artigo em Inglês | MEDLINE | ID: mdl-37278682

RESUMO

BACKGROUND: The Harmony transcatheter pulmonary valve (TPV) is the first U.S. Food and Drug Administration-approved device for severe pulmonary regurgitation (PR) in the native or surgically repaired right ventricular outflow tract (RVOT). OBJECTIVES: One-year safety and effectiveness of the Harmony TPV were evaluated in patients from the Harmony Native Outflow Tract Early Feasibility Study, Harmony TPV Pivotal Study, and Continued Access Study, representing the largest cohort to date of Harmony TPV recipients. METHODS: Eligible patients had severe PR by echocardiography or PR fraction ≥ 30% by cardiac magnetic resonance imaging and clinical indications for pulmonary valve replacement. The primary analysis included 87 patients who received a commercially available TPV22 (n = 42) or TPV25 (n = 45) device; 19 patients who received an early device iteration prior to its discontinuation were evaluated separately. RESULTS: In the primary analysis, median patient age at treatment was 26 years (IQR: 18-37 years) in the TPV22 group and 29 years (IQR: 19-42 years) in the TPV25 group. At 1 year, there were no deaths; 98% of TPV22 and 91% of TPV25 patients were free from the composite of PR, stenosis, and reintervention (moderate or worse PR, mean RVOT gradient >40 mmHg, device-related RVOT reoperation, and catheter reintervention). Nonsustained ventricular tachycardia occurred in 16% of patients. Most patients had none/trace or mild PR (98% of TPV22 patients, 97% of TPV25 patients). Outcomes with the discontinued device are reported separately. CONCLUSIONS: The Harmony TPV device demonstrated favorable clinical and hemodynamic outcomes across studies and valve types through 1 year. Further follow-up will continue to assess long-term valve performance and durability.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar , Valva Pulmonar , Obstrução do Fluxo Ventricular Externo , Humanos , Cateterismo Cardíaco , Estudos Prospectivos , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/cirurgia , Resultado do Tratamento , Obstrução do Fluxo Ventricular Externo/etiologia
4.
JACC Cardiovasc Interv ; 15(9): 979-988, 2022 05 09.
Artigo em Inglês | MEDLINE | ID: mdl-35512922

RESUMO

OBJECTIVES: The aim of this study was to evaluate the accuracy of cardiac magnetic resonance (CMR) in predicting coronary artery (CA) compression during transcatheter pulmonary valve implantation (TPVi). BACKGROUND: TPVi is a widely available option to treat dysfunctional right ventricle (RV)-to-pulmonary artery (PA) conduits, but CA compression is an absolute contraindication. CMR can evaluate coronary anatomy, but its utility in predicting CA compression is not well established. METHODS: After Institutional Review Board approval was obtained, all patients at 9 centers with attempted TPVi in RV-PA conduits and recent CMR (≤12 months) were analyzed. A core laboratory reviewed all CMR studies for the shortest orthogonal distance from a CA to the conduit, the shortest distance from a CA to the most stenotic area of the conduit, and subjective assessment of CA compression risk. RESULTS: Among 231 patients, TPVi was successful in 198 (86%); in 24 (10%), balloon testing precluded implantation (documented CA compression or high risk). Distance to the RV-PA conduit ≤2.1 mm (area under the curve [AUC]: 0.70) and distance to most stenotic area ≤13.1 mm (AUC: 0.69) predicted CA compression. Subjective assessment had the highest AUC (0.78), with 96% negative predictive value. Both distances and qualitative assessment remained independently associated with CA compression when controlling for abnormal coronary anatomy or degree of conduit calcification. CONCLUSIONS: CMR can help predict the risk for CA compression during TPVi in RV-PA conduits but cannot completely exclude CA compression. CMR may assist in patient selection and counseling families prior to TPVi, although balloon testing remains essential.


Assuntos
Implante de Prótese de Valva Cardíaca , Valva Pulmonar , Cateterismo Cardíaco/efeitos adversos , Vasos Coronários , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Espectroscopia de Ressonância Magnética , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/cirurgia , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
5.
Catheter Cardiovasc Interv ; 99(5): 1679-1682, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35253339

RESUMO

Significant hemolysis is a recognized complication of transcatheter high-velocity shunt occlusion using some Amplatzer devices. We describe a case of severe hemolysis following occlusion of an iatrogenic Gerbode defect with an Amplatzer muscular ventricular septal defect occluder successfully managed by transcatheter device removal and reocclusion with a Gore Cardioform Atrial Septal Defect Occluder.


Assuntos
Comunicação Interatrial , Comunicação Interventricular , Dispositivo para Oclusão Septal , Cateterismo Cardíaco/efeitos adversos , Comunicação Interatrial/complicações , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/terapia , Hemólise , Humanos , Dispositivo para Oclusão Septal/efeitos adversos , Resultado do Tratamento
6.
Pediatr Cardiol ; 43(7): 1438-1443, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35274168

RESUMO

Determine outcomes of catheter intervention for aortic coarctation in infants. Aortic coarctation in infants following surgical repair and in high surgical risk native cases remains a challenging problem. Catheter intervention is an alternative to surgical intervention. Single-center, chart review of infants with biventricular anatomy who underwent coarctation stent placement or balloon angioplasty between 04/2004 and 04/2020. Outcomes of interest included change in aortic lumen diameter, peak gradient, number of re-interventions, time to re-intervention, and adverse events. Thirty-four patients were included in analysis, of those 16 underwent stent placement. Patients' mean age was 4.0 ± 3.0 months and weight of 5.3 ± 1.9 kg. Follow-up interval was 5.4 ± 5.1 years (0.2-16.1 years). Twelve (35%) patients underwent procedure due to ventricular dysfunction; the rest were for high resting gradient. Coarctation diameter increased from 2.4 ± 1.0 to 4.5 ± 1.3 (p < 0.01) and gradient decreased from 32.0 ± 18.4 mmHg to 9.2 ± 8.8 mmHg (p < 0.01). Thirteen (81%) of the stented patients required at least one re-intervention, at an average of 1.7 ± 3.2 years from the index procedure. Five (28%) of those undergoing balloon angioplasty required repeat intervention. There was no mortality due to the procedure and one late mortality. One patient had a serious procedural adverse event. On follow-up, 12 (35%) were on anti-hypertensive medications. Catheter intervention, including stent placement, for aortic coarctation in infants is feasible with an acceptable adverse event profile. Repeat interventions are common.


Assuntos
Angioplastia com Balão , Coartação Aórtica , Angioplastia com Balão/efeitos adversos , Angioplastia com Balão/métodos , Anti-Hipertensivos , Coartação Aórtica/diagnóstico por imagem , Coartação Aórtica/cirurgia , Seguimentos , Humanos , Lactente , Recidiva , Estudos Retrospectivos , Stents , Resultado do Tratamento
7.
J Am Coll Cardiol ; 79(1): 18-32, 2022 01 04.
Artigo em Inglês | MEDLINE | ID: mdl-34991785

RESUMO

BACKGROUND: Transcatheter pulmonary valve (TPV) replacement (TPVR) has become the standard therapy for postoperative pulmonary outflow tract dysfunction in patients with a prosthetic conduit/valve, but there is limited information about risk factors for death or reintervention after this procedure. OBJECTIVES: This study sought to evaluate mid- and long-term outcomes after TPVR in a large multicenter cohort. METHODS: International registry focused on time-related outcomes after TPVR. RESULTS: Investigators submitted data for 2,476 patients who underwent TPVR and were followed up for 8,475 patient-years. A total of 95 patients died after TPVR, most commonly from heart failure (n = 24). The cumulative incidence of death was 8.9% (95% CI: 6.9%-11.5%) 8 years after TPVR. On multivariable analysis, age at TPVR (HR: 1.04 per year; 95% CI: 1.03-1.06 per year; P < 0.001), a prosthetic valve in other positions (HR: 2.1; 95% CI: 1.2-3.7; P = 0.014), and an existing transvenous pacemaker/implantable cardioverter-defibrillator (HR: 2.1; 95% CI: 1.3-3.4; P = 0.004) were associated with death. A total of 258 patients underwent TPV reintervention. At 8 years, the cumulative incidence of any TPV reintervention was 25.1% (95% CI: 21.8%-28.5%) and of surgical TPV reintervention was 14.4% (95% CI: 11.9%-17.2%). Risk factors for surgical reintervention included age (0.95 per year [95% CI: 0.93-0.97 per year]; P < 0.001), prior endocarditis (2.5 [95% CI: 1.4-4.3]; P = 0.001), TPVR into a stented bioprosthetic valve (1.7 [95% CI: 1.2-2.5]; P = 0.007), and postimplant gradient (1.4 per 10 mm Hg [95% CI: 1.2-1.7 per 10 mm Hg]: P < 0.001). CONCLUSIONS: These findings support the conclusion that survival and freedom from reintervention or surgery after TPVR are generally comparable to outcomes of surgical conduit/valve replacement across a wide age range.


Assuntos
Implante de Prótese de Valva Cardíaca , Valva Pulmonar/cirurgia , Reoperação/estatística & dados numéricos , Adolescente , Adulto , Fatores Etários , Criança , Pré-Escolar , Desfibriladores Implantáveis , Endocardite/epidemiologia , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial , Sistema de Registros , Adulto Jovem
8.
Circ Cardiovasc Interv ; 15(1): e010852, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34930015

RESUMO

BACKGROUND: The Melody valve was developed to extend the useful life of previously implanted right ventricular outflow tract (RVOT) conduits or bioprosthetic pulmonary valves, while preserving RV function and reducing the lifetime burden of surgery for patients with complex congenital heart disease. METHODS: Enrollment for the US Investigational Device Exemption study of the Melody valve began in 2007. Extended follow-up was completed in 2020. The primary outcome was freedom from transcatheter pulmonary valve (TPV) dysfunction (freedom from reoperation, reintervention, moderate or severe pulmonary regurgitation, and/or mean RVOT gradient >40 mm Hg). Secondary end points included stent fracture, catheter reintervention, surgical conduit replacement, and death. RESULTS: One hundred seventy-one subjects with RVOT conduit or bioprosthetic pulmonary valve dysfunction were enrolled. One hundred fifty underwent Melody TPV replacement. Median age was 19 years (Q1-Q3: 15-26). Median discharge mean RVOT Doppler gradient was 17 mm Hg (Q1-Q3: 12-22). The 149 patients implanted >24 hours were followed for a median of 8.4 years (Q1-Q3: 5.4-10.1). At 10 years, estimated freedom from mortality was 90%, from reoperation 79%, and from any reintervention 60%. Ten-year freedom from TPV dysfunction was 53% and was significantly shorter in children than in adults. Estimated freedom from TPV-related endocarditis was 81% at 10 years (95% CI, 69%-89%), with an annualized rate of 2.0% per patient-year. CONCLUSIONS: Ten-year outcomes from the Melody Investigational Device Exemption trial affirm the benefits of Melody TPV replacement in the lifetime management of patients with RVOT conduits and bioprosthetic pulmonary valves by providing sustained symptomatic and hemodynamic improvement in the majority of patients. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT00740870.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Pulmonar , Valva Pulmonar , Adolescente , Adulto , Humanos , Desenho de Prótese , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
9.
J Am Coll Cardiol ; 78(6): 575-589, 2021 08 10.
Artigo em Inglês | MEDLINE | ID: mdl-34353535

RESUMO

BACKGROUND: Endocarditis has emerged as one of the most impactful adverse events after transcatheter pulmonary valve replacement (TPVR), but there is limited information about risk factors for and outcomes of this complication. OBJECTIVES: The purpose of this study was to evaluate risk factors for and outcomes of endocarditis in a large multicenter cohort. METHODS: The authors established an international registry focused on characterizing endocarditis after TPVR, including the incidence, risk factors, characteristics, and outcomes. RESULTS: Investigators submitted data for 2,476 patients who underwent TPVR between July 2005 and March 2020 and were followed for 8,475 patient-years. In total, 182 patients were diagnosed with endocarditis a median of 2.7 years after TPVR, for a cumulative incidence of 9.5% (95% CI: 7.9%-11.1%) at 5 years and 16.9% (95% CI: 14.2%-19.8%) at 8 years (accounting for competing risks: death, heart transplant, and explant) and an annualized incidence of 2.2 per 100 patient-years. Staphylococcus aureus and Viridans group Streptococcus species together accounted for 56% of cases. Multivariable analysis confirmed that younger age, a previous history of endocarditis, and a higher residual gradient were risk factors for endocarditis, but transcatheter pulmonary valve type was not. Overall, right ventricular outflow tract (RVOT) reintervention was less often to treat endocarditis than for other reasons, but valve explant was more often caused by endocarditis. Endocarditis was severe in 44% of patients, and 12 patients (6.6%) died, nearly all of whom were infected with Staphylococcus aureus. CONCLUSIONS: The incidence of endocarditis in this multicenter registry was constant over time and consistent with prior smaller studies. The findings of this study, along with ongoing efforts to understand and mitigate risk, will be critical to improve the lifetime management of patients with heart disease involving the RVOT. Although endocarditis can be a serious adverse outcome, TPVR remains an important tool in the management of RVOT dysfunction.


Assuntos
Endocardite , Implante de Prótese de Valva Cardíaca , Valva Pulmonar/cirurgia , Reoperação , Adulto , Cateterismo Cardíaco/métodos , Endocardite/etiologia , Endocardite/microbiologia , Endocardite/mortalidade , Endocardite/cirurgia , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/estatística & dados numéricos , Humanos , Incidência , Cooperação Internacional , Masculino , Sistema de Registros/estatística & dados numéricos , Reoperação/métodos , Reoperação/estatística & dados numéricos , Staphylococcus aureus/isolamento & purificação , Obstrução do Fluxo Ventricular Externo/etiologia , Obstrução do Fluxo Ventricular Externo/cirurgia , Estreptococos Viridans/isolamento & purificação
10.
Heart ; 107(23): 1875-1880, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34380660

RESUMO

OBJECTIVE: To evaluate the frequency of and risk factors for stroke as a presenting feature in adult patients with secundum atrial septal defect (ASD); rates of post-closure atrial fibrillation (AF) and stroke were also assessed. METHODS: We retrospectively reviewed adult patients who presented with an ASD between 2002 and 2018, excluding those with known atrial arrhythmias. Risk factors for stroke were identified using multivariable logistic regression. Post-closure stroke was evaluated using survival analysis stratified by the presence of post-procedure AF. RESULTS: Of 346 patients with ASD (median age 44 years), 34 (10%) presented with a history of stroke. Independent risk factors included elevated body mass index over 25 (OR: 18.2; 95% CI: 4.0 to 82.2; p<0.001), smoking (OR: 9.5; 95% CI: 3.8 to 23.9; p<0.001) and a prominent Eustachian valve (OR: 9.2; 95% CI: 3.4 to 25.2; p<0.001). A scoring system based on these three parameters provided robust stroke risk stratification. During a median follow-up of 12 months after closure, 12 patients (4%) experienced AF and 4 patients (1%) had a new stroke. AF was highly associated with development of stroke post-closure (p<0.001). CONCLUSIONS: In this study population, the incidence of stroke prior to ASD closure among patients without atrial arrhythmias was 10%. Risk factors included obesity, smoking and prominent Eustachian valve anatomy. Lifestyle changes should be recommended for at-risk patients, and it may be reasonable to consider ASD closure in the absence of haemodynamic indications in patients at increased risk of stroke.


Assuntos
Cateterismo Cardíaco/métodos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Comunicação Interatrial/cirurgia , Complicações Pós-Operatórias/etiologia , Medição de Risco/métodos , Acidente Vascular Cerebral/etiologia , Adulto , Progressão da Doença , Ecocardiografia/métodos , Feminino , Seguimentos , Comunicação Interatrial/diagnóstico , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Prevalência , Estudos Retrospectivos , Fatores de Risco , Acidente Vascular Cerebral/epidemiologia , Estados Unidos/epidemiologia
11.
Catheter Cardiovasc Interv ; 98(2): E262-E274, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-33780150

RESUMO

OBJECTIVE: We compared 5-year outcomes of transcatheter pulmonary valve (TPV) replacement with the Melody TPV in the post-approval study (PAS) and the investigational device exemption (IDE) trial. BACKGROUND: As a condition of approval of the Melody TPV after the IDE trial, the Food and Drug Administration required that a PAS be conducted to evaluate outcomes of TPV replacement in a "real-world" environment. The 5-year outcomes of the PAS have not been published, and the IDE and PAS trials have not been compared. METHODS: The cohorts comprised all patients catheterized and implanted at 5 IDE sites and 10 PAS sites. Differences in trial protocols were detailed. Time-related outcomes and valve-related adverse events were compared between the two trials with Kaplan-Meier curves and log-rank testing. RESULTS: 167 patients (median age, 19 years) were catheterized and 150 underwent TPV replacement in the IDE trial; 121 were catheterized (median age, 17 years) and 100 implanted in the PAS. Freedom from hemodynamic dysfunction (p = .61) or any reintervention (p = .74) over time did not differ between trials. Freedom from stent fracture (p = .003) and transcatheter reintervention (p = .010) were longer in PAS, whereas freedom from explant (p = .020) and TPV endocarditis (p = .007) were shorter. Clinically important adverse events (AEs) were reported in 14% of PAS and 7.2% of IDE patients (p = .056); the incidence of any particular event was low in both. CONCLUSIONS: Hemodynamic and time-related outcomes in the PAS and IDE trials were generally similar, confirming the effectiveness of the Melody TPV with real-world providers. There were few significant complications and limited power to identify important differences in AEs. The lack of major differences in outcomes between the two studies questions the usefulness of mandated costly post-approval studies as part of the regulatory process for Class III medical devices.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar , Valva Pulmonar , Adolescente , Adulto , Cateterismo Cardíaco/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Desenho de Prótese , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/cirurgia , Resultado do Tratamento , Adulto Jovem
12.
JACC Cardiovasc Interv ; 13(13): 1529-1540, 2020 07 13.
Artigo em Inglês | MEDLINE | ID: mdl-32646693

RESUMO

OBJECTIVES: The aim of this analysis was to evaluate outcomes following transcatheter reintervention for degenerated transcatheter pulmonary valves (TPVs). BACKGROUND: TPV replacement (TPVR) with the Melody valve demonstrated sustained relief of right ventricular outflow tract (RVOT) obstruction and pulmonary regurgitation. METHODS: All patients who underwent TPVR with a Melody valve as part of 3 Medtronic-sponsored prospective multicenter studies were included. Transcatheter reinterventions included balloon dilation of the previously implanted Melody valve, placement of a bare-metal stent within the implanted TPV, or placement of a new TPV in the RVOT (TPV-in-TPV). Indications for reintervention, decisions to reintervene, and the method of reintervention were at physician discretion. All patients provided written informed consent to participate in the trials, and each trial was approved by local or central Institutional Review Boards or ethics committees at participating sites. RESULTS: A total of 309 patients who underwent TPVR were discharged from the implantation hospitalization with Melody valves in place. Transcatheter reintervention on the TPV was performed in 46 patients. The first transcatheter reintervention consisted of TPV-in-TPV in 28 patients (median 6.9 years [quartile 1 to quartile 3: 5.2 to 7.8 years] after TPVR), simple balloon dilation of the implanted Melody valve in 17 (median 4.9 years [quartile 1 to quartile 3: 4.0 to 6.0 years] after TPVR), and bare-metal stent placement alone in 1 (4.4 years after TPVR). There were no major procedural complications. Overall, 4-year freedom from explant and from any later RVOT reintervention after the first reintervention were 83% and 60%, respectively. Freedom from repeat RVOT reintervention was longer in patients undergoing TPV-in-TPV than balloon dilation (71% vs. 46% at 4 years; p = 0.027). CONCLUSIONS: TPV-in-TPV can be an effective and durable treatment for Melody valve dysfunction. Although balloon dilation of the Melody valve was also acutely effective at reducing RVOT obstruction, the durability of this therapy was limited in this cohort compared with TPV-in-TPV.


Assuntos
Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Falha de Prótese , Insuficiência da Valva Pulmonar/cirurgia , Valva Pulmonar/cirurgia , Obstrução do Fluxo Ventricular Externo/cirurgia , Adolescente , Adulto , Valvuloplastia com Balão , Cateterismo Cardíaco/efeitos adversos , Criança , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/fisiopatologia , Recuperação de Função Fisiológica , Fatores de Tempo , Resultado do Tratamento , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem , Obstrução do Fluxo Ventricular Externo/fisiopatologia , Adulto Jovem
13.
Catheter Cardiovasc Interv ; 96(6): 1266-1276, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32433821

RESUMO

OBJECTIVES: Characterize the safety and effectiveness of the Amplatzer Piccolo Occluder for patent ductus arteriosus (PDA) closure. BACKGROUND: The presence of a hemodynamically significant PDA has been associated with an increased risk of morbidity and mortality in children born premature. METHODS: This was a single arm, prospective, multicenter, non-randomized study to evaluate the Amplatzer Piccolo Occluder to treat PDA in patients ≥700 g. From June 2017 to February 2019, 200 patients were enrolled at nine centers, with 100 patients weighing ≤2 kg. Primary effectiveness endpoint was the rate of PDA closure at 6-month follow-up. Primary safety endpoint was the rate of major complications through 6 months. Secondary endpoint was rate of significant pulmonary or aortic obstruction through 6 months' follow-up. RESULTS: The implant success rate was 95.5% (191/200) overall and 99% in patients ≤2 kg (99/100). The primary effectiveness endpoint was achieved in 99.4% of implanted patients. Four patients experienced a primary safety endpoint event (2 transfusions, 1 hemolysis, and 1 aortic obstruction). There were no branch pulmonary artery obstructions. Five patients, all ≤2 kg, were noted to have worsening of tricuspid regurgitation (TR) after the procedure. None of the TR incidences manifested clinically. The Amplatzer Piccolo Occluder received FDA approval in January 2019 and became the first device approved for PDA closure in patients ≥700 g. CONCLUSIONS: This study supports the safety and effectiveness of the Amplatzer Piccolo Occluder, particularly in patients between 700 g and 2 kg where there is currently a significant unmet need in the United States. ClinicalTrials.gov identifier: NCT03055858.


Assuntos
Cateterismo Cardíaco/instrumentação , Permeabilidade do Canal Arterial/terapia , Lactente Extremamente Prematuro , Recém-Nascido de muito Baixo Peso , Dispositivo para Oclusão Septal , Peso ao Nascer , Cateterismo Cardíaco/efeitos adversos , Circulação Coronária , Permeabilidade do Canal Arterial/diagnóstico por imagem , Permeabilidade do Canal Arterial/fisiopatologia , Feminino , Idade Gestacional , Hemodinâmica , Humanos , Recém-Nascido , Masculino , Estudos Prospectivos , Desenho de Prótese , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
14.
Catheter Cardiovasc Interv ; 94(4): 607-617, 2019 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-31419019

RESUMO

OBJECTIVES: To investigate whether age and valve size at implant contribute to outcomes after Melody transcatheter pulmonary valve replacement (TPVR). BACKGROUND: Patient age and valve size at implant contribute to longevity of surgical pulmonary valves. METHODS: All patients discharged with a Melody valve in the pulmonary position, as part of three prospective Melody valve multicenter studies, comprised the study cohort. Acute and time-related outcomes were analyzed according to age: children (≤12 years), adolescents (13-18 years), young adults (19-29 years), and older adults (≥30 years). RESULTS: Successful Melody valve implantation occurred in 49 children, 107 adolescents, 96 young adults, and 57 older adults. Pediatric patients (≤18 years) were more likely to have TPVR for conduit stenosis than adults (62% vs. 44%); children had the smallest conduits. After TPVR, pediatric and adult patients had similar decreases in right ventricular (RV) size by MRI, but adults had improved percentage predicted peak VO2 (58% preimplant to 64% postimplant, p = .02) and FEV1 (69% pre to 71% post, p = .005). Younger age was associated with shorter freedom from RVOT dysfunction, reintervention, and explant. Children had the shortest freedom from endocarditis (p = .041), but all other groups had 5-year freedom from endocarditis of ≥90%. CONCLUSIONS: Younger age was associated with shorter time to RVOT dysfunction, reintervention, and explant after Melody TPVR. Patients ≥13 years of age were at low risk for endocarditis and explant to 5 years. A better understanding of time-related outcomes by age will aid in the comparison of therapeutic options for TPVR candidates. CLINICAL TRIAL REGISTRATION: https://clinicaltrials.gov/ct2/show/NCT00740870 (NCT00740870), https://clinicaltrials.gov/ct2/show/NCT01186692 (NCT01186692), and https://clinicaltrials.gov/ct2/show/NCT00688571 (NCT00688571).


Assuntos
Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Valva Pulmonar/cirurgia , Adolescente , Fatores Etários , Canadá , Cateterismo Cardíaco/efeitos adversos , Criança , Ensaios Clínicos como Assunto , Bases de Dados Factuais , Remoção de Dispositivo , Endocardite/etiologia , Endocardite/fisiopatologia , Endocardite/cirurgia , Europa (Continente) , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Hemodinâmica , Humanos , Masculino , Intervalo Livre de Progressão , Desenho de Prótese , Falha de Prótese , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/fisiopatologia , Reoperação , Fatores de Risco , Fatores de Tempo , Estados Unidos , Obstrução do Fluxo Ventricular Externo/etiologia , Obstrução do Fluxo Ventricular Externo/fisiopatologia , Obstrução do Fluxo Ventricular Externo/cirurgia , Adulto Jovem
15.
Catheter Cardiovasc Interv ; 93(3): 474-480, 2019 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-30419603

RESUMO

OBJECTIVES: This study describes procedural and 1-year outcomes of the 16 mm Melody PB1016 valve in patients with dysfunctional RVOT conduits. BACKGROUND: The Melody PB1016 is a standard Melody valve produced from a 16 mm bovine jugular vein and is intended for deployment up to 20 mm. METHODS: This is a prospective, non-randomized, multicenter study of the procedural and short-term outcomes of Melody PB1016 TPV replacement within dysfunctional RVOT conduits. Data from eight centers were included in the analysis. RESULTS: During the study period, 39 patients underwent attempted Melody TPVR. Of the 39 patients, 30 underwent successful Melody TPVR. The majority of patients underwent placement of one or more stents prior to TPVR. There was a significant reduction in peak conduit pressure gradient following TPVR (38 mmHg vs. 11 mmHg, P < 0.001). There were three cases of confined conduit tears successfully treated with covered stents or the valve itself. Repeat catheterization was performed in one patient for early re-obstruction that was successfully treated with balloon valvuloplasty. At recent follow-up, there were no cases of more than mild valve regurgitation and the mean pulmonary valve gradient by echocardiogram remained reduced relative to pre-TPVR implant measurements (33.5 mmHg vs. 15.2 mmHg). There were no cases of valve stent fracture or endocarditis reported at the 1-year follow-up. CONCLUSIONS: Our analysis of TPVR with the PB1016 valve in RVOT conduits showed it to be safe and effective and can be performed in a wide range of conduit sizes with preserved valve function. ClinicalTrials.gov Identifier: NCT02347189.


Assuntos
Bioprótese , Cateterismo Cardíaco/instrumentação , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Cardiopatias Congênitas/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Veias Jugulares/transplante , Insuficiência da Valva Pulmonar/cirurgia , Valva Pulmonar/cirurgia , Stents , Adolescente , Adulto , Animais , Canadá , Cateterismo Cardíaco/efeitos adversos , Bovinos , Criança , Europa (Continente) , Feminino , Cardiopatias Congênitas/fisiopatologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Xenoenxertos , Humanos , Masculino , Estudos Prospectivos , Desenho de Prótese , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/fisiopatologia , Recuperação de Função Fisiológica , Resultado do Tratamento , Estados Unidos , Adulto Jovem
16.
Catheter Cardiovasc Interv ; 93(4): 645-651, 2019 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-30511498

RESUMO

OBJECTIVES: To report the results of the Nit-Occlud PDA prospective postapproval study (PAS) along with a comparison to the results of the pivotal and continued access trials. BACKGROUND: The Nit-Occlud PDA (PFM Medical, Cologne, Germany), a nitinol coil patent ductus arteriosus (PDA) occluder, was approved by the Food and Drug Administration in 2013. METHODS: The PAS enrolled a total of 184 subjects greater than 6 months of age, weighing at least 5 kg, with PDAs less than 4 mm by angiography at 11 centers. Patients were followed prospectively at 2 months, 12 months, and 24 months postprocedure. These outcomes were compared to the 357 subjects enrolled in the pivotal and continued access protocols. Efficacy and safety data were reported. RESULTS: Among 184 subjects enrolled for the PAS between 2014 and 2017, 180 (97.8%) had successful device implantation. After 12 months, 98.7% (150/152) had trivial or no residual shunt by echocardiography and two subjects had only small residual shunts. There were three device embolizations that were all retrieved by snare without clinical consequence. Together with the pivotal and continued access study, 97.4% (449/461) had complete echocardiographic closure at 12 months in 541 enrolled subjects. The composite success was 94.4%. There were no mortalities and no serious device-related adverse events. CONCLUSIONS: The Nit-Occlud PDA is a safe and effective device for closure of a small to moderate sized PDA. There were no serious device-related adverse events in a large cohort of three clinical trials.


Assuntos
Cateterismo Cardíaco/instrumentação , Permeabilidade do Canal Arterial/terapia , Adolescente , Ligas , Cateterismo Cardíaco/efeitos adversos , Criança , Pré-Escolar , Aprovação de Equipamentos , Permeabilidade do Canal Arterial/diagnóstico por imagem , Desenho de Equipamento , Feminino , Humanos , Lactente , Masculino , Ensaios Clínicos Controlados não Aleatórios como Assunto , Vigilância de Produtos Comercializados , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento , Estados Unidos , Adulto Jovem
17.
J Am Coll Cardiol ; 72(22): 2717-2728, 2018 12 04.
Artigo em Inglês | MEDLINE | ID: mdl-30497557

RESUMO

BACKGROUND: Endocarditis has emerged as one of the most concerning adverse outcomes in patients with congenital anomalies involving the right ventricular outflow tract (RVOT) and prosthetic valves. OBJECTIVES: The aim of this study was to evaluate rates and potential risk factors for endocarditis after transcatheter pulmonary valve replacement in the prospective Melody valve trials. METHODS: All patients in whom a transcatheter pulmonary valve (TPV) was implanted in the RVOT as part of 3 prospective multicenter studies comprised the analytic cohort. The diagnosis of endocarditis and involvement of the TPV were determined by the implanting investigator. RESULTS: A total of 309 patients underwent transcatheter pulmonary valve replacement (TPVR) and were discharged with a valve in place. The median follow-up duration was 5.1 years, and total observation until study exit was 1,660.3 patient-years. Endocarditis was diagnosed in 46 patients (median 3.1 years after TPVR), and a total of 35 patients were reported to have TPV-related endocarditis (34 at the initial diagnosis, 1 with a second episode). The annualized incidence rate of endocarditis was 3.1% per patient-year and of TPV-related endocarditis was 2.4% per patient-year. At 5 years post-TPVR, freedom from a diagnosis of endocarditis was 89% and freedom from TPV-related endocarditis was 92%. By multivariable analysis, age ≤12 years at implant (hazard ratio: 2.3; 95% confidence interval: 1.2 to 4.4; p = 0.011) and immediate post-implant peak gradient ≥15 mm Hg (2.7; 95% confidence interval: 1.4 to 4.9; p = 0.002) were associated with development of endocarditis and with development of TPV-related endocarditis (age ≤12 years: 2.8; 95% confidence interval: 1.3 to 5.7; p = 0.006; gradient ≥15 mm Hg: 2.6; 95% confidence interval: 1.3 to 5.2; p = 0.008). CONCLUSIONS: Endocarditis is an important adverse outcome following TVPR in children and adults with post-operative congenital heart disease involving the RVOT. Ongoing efforts to understand, prevent, and optimize management of this complication are paramount in making the best use of TPV therapy. (Melody Transcatheter Pulmonary Valve [TPV] Study: Post Approval Study of the Original Investigational Device Exemption [IDE] Cohort; NCT00740870; Melody Transcatheter Pulmonary Valve Post-Approval Study; NCT01186692; and Melody Transcatheter Pulmonary Valve [TPV] Post-Market Surveillance Study; NCT00688571).


Assuntos
Endocardite Bacteriana/etiologia , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Complicações Pós-Operatórias/etiologia , Insuficiência da Valva Pulmonar/cirurgia , Valva Pulmonar/cirurgia , Adolescente , Adulto , Criança , Endocardite Bacteriana/diagnóstico por imagem , Endocardite Bacteriana/epidemiologia , Contaminação de Equipamentos , Feminino , Seguimentos , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/epidemiologia , Implante de Prótese de Valva Cardíaca/tendências , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/epidemiologia , Estudos Prospectivos , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/microbiologia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/epidemiologia , Adulto Jovem
18.
Pediatr Transplant ; 22(8): e13307, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30338630

RESUMO

BACKGROUND: The hybrid stage 1 palliation for hypoplastic left heart syndrome (HLHS) was first described in 1993 as a bridge to heart transplant for HLHS. There are limited data on this strategy as primary heart transplantation for HLHS has become less common. METHODS: This is an observational, single-center study comparing pre- and post-transplant outcomes of patients listed for transplant following hybrid palliation with those following surgical stage 1 palliation. RESULTS: From 2004 to 2017, 21 patients underwent hybrid palliation as a bridge to heart transplant and 28 patients were listed for transplant following surgical stage 1 palliation or aortic arch repair and pulmonary artery band placement. Premature birth and the presence of genetic or anatomic abnormalities were more common in the hybrid group. Need for extracorporeal membrane oxygenation (ECMO) support and ventricular dysfunction was more common in the surgical group. There was a trend toward shorter waitlist times in the surgical cohort (36 days vs 70 days, P = 0.06). There was no difference in waitlist mortality (19% vs 21%, P = 0.61). Survival at 1 and 5 years post-transplant was similar for the hybrid and surgical cohorts (5-year survival, 80% vs 85%, P = 0.94, respectively). There was no difference in the number of post-transplant interventions. CONCLUSIONS: Although the hybrid patients represented a higher risk cohort and demonstrated longer wait times, the waitlist and post-transplant mortality was equivalent between the two groups. For high-risk patients, the hybrid palliation as a bridge to transplant appears to be a reasonable strategy.


Assuntos
Transplante de Coração/métodos , Ventrículos do Coração/fisiopatologia , Síndrome do Coração Esquerdo Hipoplásico/cirurgia , Cuidados Paliativos/métodos , Aorta Torácica/cirurgia , Cardiologia/métodos , Feminino , Derivação Cardíaca Direita , Humanos , Lactente , Recém-Nascido , Masculino , Artéria Pulmonar/cirurgia , Estudos Retrospectivos , Risco , Resultado do Tratamento , Listas de Espera
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...