Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
2.
Physiol Meas ; 45(5)2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38697210

RESUMO

Objective.Electrical impedance tomography (EIT) produces clinical useful visualization of the distribution of ventilation inside the lungs. The accuracy of EIT-derived parameters can be compromised by the cardiovascular signal. Removal of these artefacts is challenging due to spectral overlapping of the ventilatory and cardiovascular signal components and their time-varying frequencies. We designed and evaluated advanced filtering techniques and hypothesized that these would outperform traditional low-pass filters.Approach.Three filter techniques were developed and compared against traditional low-pass filtering: multiple digital notch filtering (MDN), empirical mode decomposition (EMD) and the maximal overlap discrete wavelet transform (MODWT). The performance of the filtering techniques was evaluated (1) in the time domain (2) in the frequency domain (3) by visual inspection. We evaluated the performance using simulated contaminated EIT data and data from 15 adult and neonatal intensive care unit patients.Main result.Each filter technique exhibited varying degrees of effectiveness and limitations. Quality measures in the time domain showed the best performance for MDN filtering. The signal to noise ratio was best for DLP, but at the cost of a high relative and removal error. MDN outbalanced the performance resulting in a good SNR with a low relative and removal error. MDN, EMD and MODWT performed similar in the frequency domain and were successful in removing the high frequency components of the data.Significance.Advanced filtering techniques have benefits compared to traditional filters but are not always better. MDN filtering outperformed EMD and MODWT regarding quality measures in the time domain. This study emphasizes the need for careful consideration when choosing a filtering approach, depending on the dataset and the clinical/research question.


Assuntos
Artefatos , Impedância Elétrica , Processamento de Sinais Assistido por Computador , Tomografia , Humanos , Tomografia/métodos , Razão Sinal-Ruído , Adulto , Análise de Ondaletas , Sistema Cardiovascular , Recém-Nascido
3.
Respir Res ; 25(1): 179, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38664685

RESUMO

BACKGROUND: Prolonged weaning from mechanical ventilation is associated with poor clinical outcome. Therefore, choosing the right moment for weaning and extubation is essential. Electrical Impedance Tomography (EIT) is a promising innovative lung monitoring technique, but its role in supporting weaning decisions is yet uncertain. We aimed to evaluate physiological trends during a T-piece spontaneous breathing trail (SBT) as measured with EIT and the relation between EIT parameters and SBT success or failure. METHODS: This is an observational study in which twenty-four adult patients receiving mechanical ventilation performed an SBT. EIT monitoring was performed around the SBT. Multiple EIT parameters including the end-expiratory lung impedance (EELI), delta Tidal Impedance (ΔZ), Global Inhomogeneity index (GI), Rapid Shallow Breathing Index (RSBIEIT), Respiratory Rate (RREIT) and Minute Ventilation (MVEIT) were computed on a breath-by-breath basis from stable tidal breathing periods. RESULTS: EELI values dropped after the start of the SBT (p < 0.001) and did not recover to baseline after restarting mechanical ventilation. The ΔZ dropped (p < 0.001) but restored to baseline within seconds after restarting mechanical ventilation. Five patients failed the SBT, the GI (p = 0.01) and transcutaneous CO2 (p < 0.001) values significantly increased during the SBT in patients who failed the SBT compared to patients with a successful SBT. CONCLUSION: EIT has the potential to assess changes in ventilation distribution and quantify the inhomogeneity of the lungs during the SBT. High lung inhomogeneity was found during SBT failure. Insight into physiological trends for the individual patient can be obtained with EIT during weaning from mechanical ventilation, but its role in predicting weaning failure requires further study.


Assuntos
Impedância Elétrica , Tomografia , Desmame do Respirador , Humanos , Desmame do Respirador/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Tomografia/métodos , Monitorização Fisiológica/métodos , Adulto , Respiração Artificial/métodos , Respiração , Idoso de 80 Anos ou mais , Pulmão/fisiopatologia , Pulmão/diagnóstico por imagem , Pulmão/fisiologia
4.
Intensive Care Med Exp ; 12(1): 30, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38502268

RESUMO

BACKGROUND: Mechanical power (MP) is the energy delivered by the ventilator to the respiratory system and combines factors related to the development of ventilator-induced lung injury (VILI). Flow-controlled ventilation (FCV) is a new ventilation mode using a constant low flow during both inspiration and expiration, which is hypothesized to lower the MP and to improve ventilation homogeneity. Data demonstrating these effects are scarce, since previous studies comparing FCV with conventional controlled ventilation modes in ICU patients suffer from important methodological concerns. OBJECTIVES: This study aims to assess the difference in MP between FCV and pressure-controlled ventilation (PCV). Secondary aims were to explore the effect of FCV in terms of minute volume, ventilation distribution and homogeneity, and gas exchange. METHODS: This is a physiological study in post-cardiothoracic surgery patients requiring mechanical ventilation in the ICU. During PCV at baseline and 90 min of FCV, intratracheal pressure, airway flow and electrical impedance tomography (EIT) were measured continuously, and hemodynamics and venous and arterial blood gases were obtained repeatedly. Pressure-volume loops were constructed for the calculation of the MP. RESULTS: In 10 patients, optimized FCV versus PCV resulted in a lower MP (7.7 vs. 11.0 J/min; p = 0.004). Although FCV did not increase overall ventilation homogeneity, it did lead to an improved ventilation of the dependent lung regions. A stable gas exchange at lower minute volumes was obtained. CONCLUSIONS: FCV resulted in a lower MP and improved ventilation of the dependent lung regions in post-cardiothoracic surgery patients on the ICU. Trial registration Clinicaltrials.gov identifier: NCT05644418. Registered 1 December 2022, retrospectively registered.

6.
Curr Opin Crit Care ; 30(1): 28-34, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38062927

RESUMO

PURPOSE OF REVIEW: To summarize the key concepts, physiological rationale and clinical evidence for titrating positive end-expiratory pressure (PEEP) using transpulmonary pressure ( PL ) derived from esophageal manometry, and describe considerations to facilitate bedside implementation. RECENT FINDINGS: The goal of an esophageal pressure-based PEEP setting is to have sufficient PL at end-expiration to keep (part of) the lung open at the end of expiration. Although randomized studies (EPVent-1 and EPVent-2) have not yet proven a clinical benefit of this approach, a recent posthoc analysis of EPVent-2 revealed a potential benefit in patients with lower APACHE II score and when PEEP setting resulted in end-expiratory PL values close to 0 ±â€Š2 cmH 2 O instead of higher or more negative values. Technological advances have made esophageal pressure monitoring easier to implement at the bedside, but challenges regarding obtaining reliable measurements should be acknowledged. SUMMARY: Esophageal pressure monitoring has the potential to individualize the PEEP settings. Future studies are needed to evaluate the clinical benefit of such approach.


Assuntos
Pulmão , Respiração com Pressão Positiva , Humanos , Manometria , Esôfago/fisiologia
7.
Am J Respir Crit Care Med ; 209(6): 670-682, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38127779

RESUMO

Hypoxemic respiratory failure is one of the leading causes of mortality in intensive care. Frequent assessment of individual physiological characteristics and delivery of personalized mechanical ventilation (MV) settings is a constant challenge for clinicians caring for these patients. Electrical impedance tomography (EIT) is a radiation-free bedside monitoring device that is able to assess regional lung ventilation and changes in aeration. With real-time tomographic functional images of the lungs obtained through a thoracic belt, clinicians can visualize and estimate the distribution of ventilation at different ventilation settings or following procedures such as prone positioning. Several studies have evaluated the performance of EIT to monitor the effects of different MV settings in patients with acute respiratory distress syndrome, allowing more personalized MV. For instance, EIT could help clinicians find the positive end-expiratory pressure that represents a compromise between recruitment and overdistension and assess the effect of prone positioning on ventilation distribution. The clinical impact of the personalization of MV remains to be explored. Despite inherent limitations such as limited spatial resolution, EIT also offers a unique noninvasive bedside assessment of regional ventilation changes in the ICU. This technology offers the possibility of a continuous, operator-free diagnosis and real-time detection of common problems during MV. This review provides an overview of the functioning of EIT, its main indices, and its performance in monitoring patients with acute respiratory failure. Future perspectives for use in intensive care are also addressed.


Assuntos
Síndrome do Desconforto Respiratório , Insuficiência Respiratória , Humanos , Impedância Elétrica , Tomografia Computadorizada por Raios X/métodos , Pulmão , Insuficiência Respiratória/diagnóstico por imagem , Insuficiência Respiratória/terapia , Tomografia/métodos , Síndrome do Desconforto Respiratório/diagnóstico por imagem , Síndrome do Desconforto Respiratório/terapia
9.
Intensive Care Med Exp ; 11(1): 73, 2023 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-37891413

RESUMO

There is a need to monitor tidal volume in critically ill patients with acute respiratory failure, given its relation with adverse clinical outcome. However, quantification of tidal volume in non-intubated patients is challenging. In this proof-of-concept study, we evaluated whether ultrasound measurements of diaphragm excursion could be a valid surrogate for tidal volume in patients with respiratory failure. Diaphragm excursions and tidal volumes were simultaneously measured in invasively ventilated patients (N = 21) and healthy volunteers (N = 20). Linear mixed models were used to estimate the ratio between tidal volume and diaphragm excursion. The tidal volume-diaphragm excursion ratio was 201 mL/cm in ICU patients [95% confidence interval (CI) 161-240 mL/cm], and 361 (294-428) mL/cm in healthy volunteers. An excellent association was shown within participants (R2 = 0.96 in ICU patients, R2 = 0.90 in healthy volunteers). However, the differences between observed tidal volume and tidal volume as predicted by the linear mixed models were considerable: the 95% limits of agreement in Bland-Altman plots were ± 91 mL in ICU patients and ± 396 mL in healthy volunteers. Likewise, the variability in tidal volume estimation between participants was large. This study shows that diaphragm excursions measured with ultrasound correlate with tidal volume, yet quantification of absolute tidal volume from diaphragm excursion is unreliable.

10.
Eur Respir Rev ; 32(168)2023 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-37197768

RESUMO

There is a well-recognised importance for personalising mechanical ventilation settings to protect the lungs and the diaphragm for each individual patient. Measurement of oesophageal pressure (P oes) as an estimate of pleural pressure allows assessment of partitioned respiratory mechanics and quantification of lung stress, which helps our understanding of the patient's respiratory physiology and could guide individualisation of ventilator settings. Oesophageal manometry also allows breathing effort quantification, which could contribute to improving settings during assisted ventilation and mechanical ventilation weaning. In parallel with technological improvements, P oes monitoring is now available for daily clinical practice. This review provides a fundamental understanding of the relevant physiological concepts that can be assessed using P oes measurements, both during spontaneous breathing and mechanical ventilation. We also present a practical approach for implementing oesophageal manometry at the bedside. While more clinical data are awaited to confirm the benefits of P oes-guided mechanical ventilation and to determine optimal targets under different conditions, we discuss potential practical approaches, including positive end-expiratory pressure setting in controlled ventilation and assessment of inspiratory effort during assisted modes.


Assuntos
Pulmão , Respiração Artificial , Humanos , Respiração Artificial/efeitos adversos , Mecânica Respiratória/fisiologia , Ventiladores Mecânicos , Monitorização Fisiológica
11.
Am J Respir Crit Care Med ; 208(1): 25-38, 2023 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-37097986

RESUMO

Rationale: Defining lung recruitability is needed for safe positive end-expiratory pressure (PEEP) selection in mechanically ventilated patients. However, there is no simple bedside method including both assessment of recruitability and risks of overdistension as well as personalized PEEP titration. Objectives: To describe the range of recruitability using electrical impedance tomography (EIT), effects of PEEP on recruitability, respiratory mechanics and gas exchange, and a method to select optimal EIT-based PEEP. Methods: This is the analysis of patients with coronavirus disease (COVID-19) from an ongoing multicenter prospective physiological study including patients with moderate-severe acute respiratory distress syndrome of different causes. EIT, ventilator data, hemodynamics, and arterial blood gases were obtained during PEEP titration maneuvers. EIT-based optimal PEEP was defined as the crossing point of the overdistension and collapse curves during a decremental PEEP trial. Recruitability was defined as the amount of modifiable collapse when increasing PEEP from 6 to 24 cm H2O (ΔCollapse24-6). Patients were classified as low, medium, or high recruiters on the basis of tertiles of ΔCollapse24-6. Measurements and Main Results: In 108 patients with COVID-19, recruitability varied from 0.3% to 66.9% and was unrelated to acute respiratory distress syndrome severity. Median EIT-based PEEP differed between groups: 10 versus 13.5 versus 15.5 cm H2O for low versus medium versus high recruitability (P < 0.05). This approach assigned a different PEEP level from the highest compliance approach in 81% of patients. The protocol was well tolerated; in four patients, the PEEP level did not reach 24 cm H2O because of hemodynamic instability. Conclusions: Recruitability varies widely among patients with COVID-19. EIT allows personalizing PEEP setting as a compromise between recruitability and overdistension. Clinical trial registered with www.clinicaltrials.gov (NCT04460859).


Assuntos
COVID-19 , Síndrome do Desconforto Respiratório , Humanos , Impedância Elétrica , Estudos Prospectivos , Pulmão/diagnóstico por imagem , Síndrome do Desconforto Respiratório/diagnóstico por imagem , Síndrome do Desconforto Respiratório/terapia , Tomografia Computadorizada por Raios X/métodos , Tomografia/métodos
12.
Anesthesiology ; 138(3): 274-288, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36520507

RESUMO

BACKGROUND: Monitoring and controlling lung stress and diaphragm effort has been hypothesized to limit lung injury and diaphragm injury. The occluded inspiratory airway pressure (Pocc) and the airway occlusion pressure at 100 ms (P0.1) have been used as noninvasive methods to assess lung stress and respiratory muscle effort, but comparative performance of these measures and their correlation to diaphragm effort is unknown. The authors hypothesized that Pocc and P0.1 correlate with diaphragm effort and lung stress and would have strong discriminative performance in identifying extremes of lung stress and diaphragm effort. METHODS: Change in transdiaphragmatic pressure and transpulmonary pressure was obtained with double-balloon nasogastric catheters in critically ill patients (n = 38). Pocc and P0.1 were measured every 1 to 3 h. Correlations between Pocc and P0.1 with change in transdiaphragmatic pressure and transpulmonary pressure were computed from patients from the first cohort. Accuracy of Pocc and P0.1 to identify patients with extremes of lung stress (change in transpulmonary pressure > 20 cm H2O) and diaphragm effort (change in transdiaphragmatic pressure < 3 cm H2O and >12 cm H2O) in the preceding hour was assessed with area under receiver operating characteristic curves. Cutoffs were validated in patients from the second cohort (n = 13). RESULTS: Pocc and P0.1 correlate with change in transpulmonary pressure (R2 = 0.62 and 0.51, respectively) and change in transdiaphragmatic pressure (R2 = 0.53 and 0.22, respectively). Area under receiver operating characteristic curves to detect high lung stress is 0.90 (0.86 to 0.94) for Pocc and 0.88 (0.84 to 0.92) for P0.1. Area under receiver operating characteristic curves to detect low diaphragm effort is 0.97 (0.87 to 1.00) for Pocc and 0.93 (0.81 to 0.99) for P0.1. Area under receiver operating characteristic curves to detect high diaphragm effort is 0.86 (0.81 to 0.91) for Pocc and 0.73 (0.66 to 0.79) for P0.1. Performance was similar in the external dataset. CONCLUSIONS: Pocc and P0.1 correlate with lung stress and diaphragm effort in the preceding hour. Diagnostic performance of Pocc and P0.1 to detect extremes in these parameters is reasonable to excellent. Pocc is more accurate in detecting high diaphragm effort.


Assuntos
Diafragma , Respiração Artificial , Humanos , Diafragma/fisiologia , Respiração Artificial/métodos , Estado Terminal , Músculos Respiratórios , Pulmão
14.
Respir Care ; 68(5): 611-619, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36368776

RESUMO

BACKGROUND: The Oxylator is an automatic resuscitator, powered only by an oxygen cylinder with no electricity required, that could be used in acute respiratory failure in situations in which standard mechanical ventilation is not available or feasible. We aimed to assess the feasibility and safety of mechanical ventilation by using this automatic resuscitator in an animal model of ARDS. METHODS: A randomized experimental study in a porcine ARDS model with 12 pigs randomized to the Oxylator group or the control group (6 per group) and ventilated for 4 h. In the Oxylator group, peak pressure was set at 20 cm H2O and PEEP was set at the lowest observed breathing frequency during a decremental PEEP titration. The control pigs were ventilated with a conventional ventilator by using protective settings and PEEP at the crossing point of collapse and overdistention, as indicated by electrical impedance tomography. Our end points were feasibility and safety as well as respiratory mechanics, gas exchange, and hemodynamics. RESULTS: After lung injury, the mean ± SD respiratory system compliance and PaO2 /FIO2 were 13 ± 2 mL/cm H2O and 61 ± 17 mm Hg, respectively. The mean ± SD total PEEP was 10 ± 2 cm H2O and 13 ± 2 cm H2O in the control and Oxylator groups, respectively (P = .046). The mean plateau pressure was kept to < 30 cm H2O in both groups. In the Oxylator group, the tidal volume was transiently > 8 mL/kg but was 6 ± 0.4 mL/kg at 4 h, whereas the breathing frequency increased from 38 ± 4 to 48 ± 3 breaths/min (P < .001). There was no difference in driving pressure, compliance, PaO2 /FIO2 , and pulmonary shunt between the groups. The mean ± SD PaCO2 was higher in the Oxylator group after 4 h, 74 ± 9 mm Hg versus 58 ± 6 mm Hg (P < .001). There were no differences in hemodynamics between the groups, including blood pressure and cardiac output. CONCLUSIONS: Short-term mechanical ventilation by using an automatic resuscitator and a fixed pressure setting in an ARDS animal model was feasible and safe.


Assuntos
Respiração Artificial , Síndrome do Desconforto Respiratório , Animais , Pulmão , Respiração com Pressão Positiva/métodos , Respiração Artificial/métodos , Síndrome do Desconforto Respiratório/terapia , Suínos , Volume de Ventilação Pulmonar
15.
Chest ; 162(6): e343-e345, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36494141
16.
Crit Care Med ; 50(11): 1607-1617, 2022 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-35866658

RESUMO

OBJECTIVES: To determine the diagnostic accuracy of lung ultrasound signs for both the diagnosis of interstitial syndrome and for the discrimination of noncardiogenic interstitial syndrome (NCIS) from cardiogenic pulmonary edema (CPE) in a mixed ICU population. DESIGN: A prospective diagnostic accuracy study with derivation and validation cohorts. SETTING: Three academic mixed ICUs in the Netherlands. PATIENTS: Consecutive adult ICU patients that received a lung ultrasound examination. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULT: The reference standard was the diagnosis of interstitial syndrome (NCIS or CPE) or noninterstitial syndromes (other pulmonary diagnoses and no pulmonary diagnoses) based on full post-hoc clinical chart review except lung ultrasound. The index test was a lung ultrasound examination performed and scored by a researcher blinded to clinical information. A total of 101 patients were included in the derivation and 122 in validation cohort. In the derivation cohort, patients with interstitial syndrome ( n = 56) were reliably discriminated from other patients based on the presence of a B-pattern (defined as greater than or equal to 3 B-lines in one frame) with an accuracy of 94.7% (sensitivity, 90.9%; specificity, 91.1%). For discrimination of NCIS ( n = 29) from CPE ( n = 27), the presence of bilateral pleural line abnormalities (at least two: fragmented, thickened or irregular) had the highest diagnostic accuracy (94.6%; sensitivity, 89.3%; specificity, 100%). A diagnostic algorithm (Bedside Lung Ultrasound for Interstitial Syndrome Hierarchy protocol) using B-pattern and bilateral pleural abnormalities had an accuracy of 0.86 (95% CI, 0.77-0.95) for diagnosis and discrimination of interstitial syndromes. In the validation cohort, which included 122 patients with interstitial syndrome, bilateral pleural line abnormalities discriminated NCIS ( n = 98) from CPE ( n = 24) with a sensitivity of 31% (95% CI, 21-40%) and a specificity of 100% (95% CI, 86-100%). CONCLUSIONS: Lung ultrasound can diagnose and discriminate interstitial syndromes in ICU patients with moderate-to-good accuracy. Pleural line abnormalities are highly specific for NCIS, but sensitivity is limited.


Assuntos
Pulmão , Edema Pulmonar , Adulto , Humanos , Unidades de Terapia Intensiva , Pulmão/diagnóstico por imagem , Estudos Prospectivos , Sensibilidade e Especificidade , Ultrassonografia/métodos
17.
Chest ; 161(6): e337-e341, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35680312

RESUMO

In critically ill patients receiving mechanical ventilation, expiratory muscles are recruited with high respiratory loading and/or low inspiratory muscle capacity. In this case report, we describe a previously unrecognized patient-ventilator dyssynchrony characterized by ventilator triggering by expiratory muscle relaxation, an observation that we termed expiratory muscle relaxation-induced ventilator triggering (ERIT). ERIT can be recognized with in-depth respiratory muscle monitoring as (1) an increase in gastric pressure (Pga) during expiration, resulting from expiratory muscle recruitment; (2) a drop in Pga (and hence, esophageal pressure) at the time of ventilator triggering; and (3) diaphragm electrical activity onset occurring after ventilator triggering. Future studies should focus on the incidence of ERIT and the impact in the patient receiving mechanical ventilation.


Assuntos
Doenças Neuromusculares , Humanos , Expiração/fisiologia , Relaxamento Muscular , Respiração Artificial/efeitos adversos , Respiração Artificial/métodos , Músculos Respiratórios/fisiologia , Ventiladores Mecânicos
19.
Crit Care Med ; 50(2): 192-203, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-35100192

RESUMO

OBJECTIVES: Lung- and diaphragm-protective ventilation is a novel concept that aims to limit the detrimental effects of mechanical ventilation on the diaphragm while remaining within limits of lung-protective ventilation. The premise is that low breathing effort under mechanical ventilation causes diaphragm atrophy, whereas excessive breathing effort induces diaphragm and lung injury. In a proof-of-concept study, we aimed to assess whether titration of inspiratory support based on diaphragm effort increases the time that patients have effort in a predefined "diaphragm-protective" range, without compromising lung-protective ventilation. DESIGN: Randomized clinical trial. SETTING: Mixed medical-surgical ICU in a tertiary academic hospital in the Netherlands. PATIENTS: Patients (n = 40) with respiratory failure ventilated in a partially-supported mode. INTERVENTIONS: In the intervention group, inspiratory support was titrated hourly to obtain transdiaphragmatic pressure swings in the predefined "diaphragm-protective" range (3-12 cm H2O). The control group received standard-of-care. MEASUREMENTS AND MAIN RESULTS: Transdiaphragmatic pressure, transpulmonary pressure, and tidal volume were monitored continuously for 24 hours in both groups. In the intervention group, more breaths were within "diaphragm-protective" range compared with the control group (median 81%; interquartile range [64-86%] vs 35% [16-60%], respectively; p < 0.001). Dynamic transpulmonary pressures (20.5 ± 7.1 vs 18.5 ± 7.0 cm H2O; p = 0.321) and tidal volumes (7.56 ± 1.47 vs 7.54 ± 1.22 mL/kg; p = 0.961) were not different in the intervention and control group, respectively. CONCLUSIONS: Titration of inspiratory support based on patient breathing effort greatly increased the time that patients had diaphragm effort in the predefined "diaphragm-protective" range without compromising tidal volumes and transpulmonary pressures. This study provides a strong rationale for further studies powered on patient-centered outcomes.


Assuntos
Diafragma/metabolismo , Pulmão/metabolismo , Respiração Artificial/normas , Trabalho Respiratório/fisiologia , Diafragma/fisiopatologia , Feminino , Humanos , Unidades de Terapia Intensiva/organização & administração , Unidades de Terapia Intensiva/estatística & dados numéricos , Pulmão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Países Baixos/epidemiologia , Respiração Artificial/métodos , Respiração Artificial/estatística & dados numéricos , Insuficiência Respiratória/epidemiologia , Insuficiência Respiratória/prevenção & controle , Insuficiência Respiratória/terapia , Trabalho Respiratório/efeitos dos fármacos
20.
Crit Care Med ; 50(5): 750-759, 2022 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-34582414

RESUMO

OBJECTIVES: To determine the diagnostic accuracy of extended lung ultrasonographic assessment, including evaluation of dynamic air bronchograms and color Doppler imaging to differentiate pneumonia and atelectasis in patients with consolidation on chest radiograph. Compare this approach to the Simplified Clinical Pulmonary Infection Score, Lung Ultrasound Clinical Pulmonary Infection Score, and the Bedside Lung Ultrasound in Emergency protocol. DESIGN: Prospective diagnostic accuracy study. SETTING: Adult ICU applying selective digestive decontamination. PATIENTS: Adult patients that underwent a chest radiograph for any indication at any time during admission. Patients with acute respiratory distress syndrome, coronavirus disease 2019, severe thoracic trauma, and infectious isolation measures were excluded. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Lung ultrasound was performed within 24 hours of chest radiograph. Consolidated tissue was assessed for presence of dynamic air bronchograms and with color Doppler imaging for presence of flow. Clinical data were recorded after ultrasonographic assessment. The primary outcome was diagnostic accuracy of dynamic air bronchogram and color Doppler imaging alone and within a decision tree to differentiate pneumonia from atelectasis. Of 120 patients included, 51 (42.5%) were diagnosed with pneumonia. The dynamic air bronchogram had a 45% (95% CI, 31-60%) sensitivity and 99% (95% CI, 92-100%) specificity. Color Doppler imaging had a 90% (95% CI, 79-97%) sensitivity and 68% (95% CI, 56-79%) specificity. The combined decision tree had an 86% (95% CI, 74-94%) sensitivity and an 86% (95% CI, 75-93%) specificity. The Bedside Lung Ultrasound in Emergency protocol had a 100% (95% CI, 93-100%) sensitivity and 0% (95% CI, 0-5%) specificity, while the Simplified Clinical Pulmonary Infection Score and Lung Ultrasound Clinical Pulmonary Infection Score had a 41% (95% CI, 28-56%) sensitivity, 84% (95% CI, 73-92%) specificity and 68% (95% CI, 54-81%) sensitivity, 81% (95% CI, 70-90%) specificity, respectively. CONCLUSIONS: In critically ill patients with pulmonary consolidation on chest radiograph, an extended lung ultrasound protocol is an accurate and directly bedside available tool to differentiate pneumonia from atelectasis. It outperforms standard lung ultrasound and clinical scores.


Assuntos
COVID-19 , Pneumonia , Atelectasia Pulmonar , Adulto , Estado Terminal , Humanos , Pulmão/diagnóstico por imagem , Pneumonia/diagnóstico por imagem , Estudos Prospectivos , Atelectasia Pulmonar/diagnóstico por imagem , Sensibilidade e Especificidade , Ultrassonografia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...