1.
Nucl Med Commun ; 45(5): 389-395, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38312095

RESUMO

OBJECTIVES: To increase understanding of optimal imaging parameters [ 18 F]PSMA-1007 when imaging patients with prostate cancer and to determine interrater agreement using [ 18 F]PSMA-1007. METHODS: In this observational study, four independent physicians read reconstruction sets using bedtimes of 1, 2 and 3 minutes of patients undergoing [ 18 F]PSMA-1007. positron emission topography. Clear and equivocal lesions and their locations were recorded. Image noise was rated on a four-point scale. Lesion counts were compared using inter-class correlation whereas noise ratings were compared using generalized estimating equations. Repeated cases were used to assess intra-rater agreement. RESULTS: Sixty reconstruction sets of 16 consecutively examined participants were included. Participants had a mean age of 71.5 years, six of them were examined prior to any treatment, three had a history of radiotherapy and seven of prostatectomy. Median Gleason score of primary tumors was 7. Imaging was performed after a mean of 132 min using a mean 3.95 MBq/Kg body weight of [ 18 F] PSMA-1007. Neither the total number of lesions per location nor the proportion of equivocal lesions varied consistently between bedtimes. Inter-rater reliability scores varied depending on location from 0.40 to 1.0 and were similar for all bedtimes. Intra-rater reliability varied between 0.70 and 0.76 for the three different bedtimes. Noise ratings were significantly lower for 1 minute than 3 minutes per bed. CONCLUSION: In the setting of [ 18 F]PSMA-1007 PET CT, 1, 2 and 3 minutes per bed produce similar results unlikely to affect clinical interpretation. Image noise ratings favor 2 and 3 minutes per bed.


Assuntos
Niacinamida/análogos & derivados , Oligopeptídeos , Tomografia por Emissão de Pósitrons , Neoplasias da Próstata , Masculino , Humanos , Idoso , Reprodutibilidade dos Testes , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Neoplasias da Próstata/patologia , Radioisótopos de Gálio
3.
Diagnostics (Basel) ; 11(4)2021 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-33807370

RESUMO

In prostate cancer, the early detection of distant spread has been shown to be of importance. Prostate-specific membrane antigen (PSMA)-binding radionuclides in positron emission tomography (PET) is a promising method for precise disease staging. PET diagnostics depend on image reconstruction techniques, and ordered subset expectation maximization (OSEM) is the established standard. Block sequential regularized expectation maximization (BSREM) is a more recent reconstruction algorithm and may produce fewer equivocal findings and better lesion detection. METHODS: 68Ga PSMA-11 PET/CT scans of patients with de novo or suspected recurrent prostate cancer were retrospectively reformatted using both the OSEM and BSREM algorithms. The lesions were counted and categorized by three radiologists. The intra-class correlation (ICC) and Cohen's kappa for the inter-rater reliability were calculated. RESULTS: Sixty-one patients were reviewed. BSREM identified slightly fewer lesions overall and fewer equivocal findings. ICC was excellent with regards to definitive lymph nodes and bone metastasis identification and poor with regards to equivocal metastasis irrespective of the reconstruction algorithm. The median Cohen's kappa were 0.66, 0.74, 0.61 and 0.43 for OSEM and 0.61, 0.63, 0.66 and 0.53 for BSREM, with respect to the tumor, local lymph nodes, metastatic lymph nodes and bone metastasis detection, respectively. CONCLUSIONS: BSREM in the setting of 68Ga PMSA PET staging or restaging is comparable to OSEM.

4.
Ultrasound J ; 13(1): 3, 2021 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-33544258

RESUMO

BACKGROUND: Renal resistive index (RRI) is a promising tool for the assessment of acute kidney injury (AKI) in critically ill patients in general, but its role and association to AKI among patients with Coronavirus disease 2019 (COVID-19) is not known. OBJECTIVE: The aim of this study was to describe the pattern of RRI in relation to AKI in patients with COVID-19 treated in the intensive care unit. METHODS: In this observational cohort study, RRI was measured in COVID-19 patients in six intensive care units at two sites of a Swedish University Hospital. AKI was defined by the creatinine criteria in the Kidney Disease Improving Global Outcomes classification. We investigated the association between RRI and AKI diagnosis, different AKI stages and urine output. RESULTS: RRI was measured in 51 patients, of which 23 patients (45%) had AKI at the time of measurement. Median RRI in patients with AKI was 0.80 (IQR 0.71-0.85) compared to 0.72 (IQR 0.67-0.78) in patients without AKI (p = 0.004). Compared to patients without AKI, RRI was higher in patients with AKI stage 3 (median 0.83, IQR 0.71-0.85, p = 0.006) but not in patients with AKI stage 1 (median 0.76, IQR 0.71-0.83, p = 0.347) or AKI stage 2 (median 0.79, min/max 0.79/0.80, n = 2, p = 0.134). RRI was higher in patients with an ongoing AKI episode compared to patients who never developed AKI (median 0.72, IQR 0.69-0.78, p = 0.015) or patients who developed AKI but had recovered at the time of measurement (median 0.68, IQR 0.67-0.81, p = 0.021). Oliguric patients had higher RRI (median 0.84, IQR 0.83-0.85) compared to non-oliguric patients (median 0.74, IQR 0.69-0.81) (p = 0.009). After multivariable adjustment, RRI was independently associated with AKI (OR for 0.01 increments of RRI 1.22, 95% CI 1.07-1.41). CONCLUSIONS: Critically ill COVID-19 patients with AKI have higher RRI compared to those without AKI, and elevated RRI may have a role in identifying severe and oliguric AKI at the bedside in these patients.

5.
Acta Radiol Open ; 8(12): 2058460119880315, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31839989

RESUMO

BACKGROUND: If screening participants do not trust computerized decision-making, screening participation may be affected by the introduction of such methods. PURPOSE: To survey breast cancer screening participants' attitudes towards potential future uses of computerization. MATERIAL AND METHODS: A survey was constructed. Women in a breast cancer screening program were invited via the final report letter to participate. Data were collected from February 2018 to March 2019 and 2196 surveys were completed. Questions asked participants to rate propositions using Likert scales. Data analysis was done using χ2 and logistic regression tests. RESULTS: The mean age of participants was 61 years. Response rate was 1.3%. Of the submitted surveys, 97.5% were complete; 38% of respondents reported a preference for a computer-only examination. The highest level of confidence was given a computer-only reading followed by a physician reading. Participants with > 12 years of education were more likely to prefer a computer-only reading (odds ratio [OR] 1.655, 95% confidence interval [CI] 1.168-2.344), had a greater trust in letting a computer determine screening intervals and the need for a supplemental MRI (OR 1.606, 95% CI 1.171-2.202 and OR 1.577, 95% CI 1.107-2.247, respectively). Age was not found to be a significant predictor. CONCLUSION: A high level of trust in computerized decision-making was expressed. Higher age was associated with a lower understanding of technology but did not affect attitudes to computerized decision-making. A lower level of education was associated with a lower trust in computerization. This may be valuable knowledge for future studies.

7.
Paediatr Anaesth ; 18(2): 184-7, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18184252

RESUMO

The loss-of-resistance technique was used to place a 20G epidural needle in the lumbar region in an anesthetized and paralyzed infant. There was no cerebrospinal fluid (CSF) leakage and a 24G catheter was inserted through the needle. At end of surgery, when the patient was breathing spontaneously and a bupivacaine bolus was given through the catheter, a total spinal block was identified. A bench test demonstrated that CSF leakage from a 20G needle can be delayed if CSF pressure is low and if air bubbles are present in the needle.


Assuntos
Analgesia Epidural/efeitos adversos , Agulhas/efeitos adversos , Feminino , Hemodinâmica , Humanos , Lactente , Período Pós-Operatório , Punção Espinal