Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Vasc Surg Cases Innov Tech ; 9(4): 101362, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38078281

RESUMO

The off-the-shelf single fenestrated stent graft is based on the Cook Zenith fenestrated platform (Cook Medical Europe) with a premade 8-mm fenestration for the superior mesenteric artery (SMA). The device is suitable for emergency treatment of paravisceral aneurysms when combined with in situ laser fenestration for the renal arteries (and, if required, the celiac trunk). The presence of a premade SMA fenestration results in minimal visceral ischemia time. We present the case of a 69-year-old woman with a ruptured Crawford type I thoracoabdominal aortic aneurysm and a tandem abdominal aortic aneurysm that was treated successfully using the single fenestrated device with in situ laser fenestration for the renal arteries, with no SMA ischemia time. A 6-month computed tomography angiogram showed patent renovisceral stents without an endoleak.

2.
J Endovasc Ther ; : 15266028231215976, 2023 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-38049945

RESUMO

INTRODUCTION: Endovascular solutions to emergent juxtarenal and pararenal abdominal aortic aneurysms (AAAs) are complicated. Endovascular aortic repair (EVAR) with in situ laser fenestration (ISLF) is promising but requires a period of visceral ischemia. With an off-the-shelf, single superior mesenteric artery (SMA)-fenestrated device mesenteric ischemia is avoided and renal ischemia decreased. The aim was to develop an optimized design of such an endograft suitable for >90% of juxtarenal and pararenal AAAs. METHODS: Single-center analysis on 44 consecutive preoperative CTs for previously elective fenestrated EVARs for juxtarenal and pararenal aneurysms. Anatomical characteristics were analyzed to define: (1) shortest aortic coverage above SMA fenestration to achieve ≥4 cm seal; (2) feasibility of a scallop for the celiac artery; (3) shortest distance between the SMA and lowest renal, to facilitate renal ISLF in a straight endograft; (4) distance from the lowest renal to the aortic bifurcation, to allow an overlapping zone >40 mm with a bifurcated stent graft; (5) aortic diameter in the sealing zone, for optimal proximal stent graft diameter with 10% to 30% oversizing; (6) the final design was then tested on individual level. RESULTS: (1) The stent graft needs to start 40 mm above the SMA fenestration to achieve a 4 cm sealing zone in >90% of cases. (2) A proximal sealing zone of 40 mm without a scallop covers 77% of celiac arteries. With an addition of a 20 mm deep, 20 mm wide scallop at 12:30, the stent graft still covers 27% of celiacs. This suggests that a scallop would not be practically feasible. (3) In >90% of cases, the lowest renal was <31 mm from the SMA, suggesting that the tapering should start 30 mm below the SMA. (4) The distance from the lowest renal to the aortic bifurcation ranged from 82 to 166 mm. This allows for a 20 mm tapering and 50 mm straight part in all cases. (5) The 5th and 95th percentile of the aortic diameter in the sealing zone was 22 and 31 mm, respectively. Thus, 2 different stent graft diameters (28 and 34 mm) would fit >90% of cases. (6) The final design was suitable in 91% cases. CONCLUSIONS: Two sizes of a single-fenestrated aortic stent graft without scallop cover >90% of juxtarenal and pararenal anatomies. CLINICAL IMPACT: Emergent juxta- and pararenal aortic aneurysms is a difficult clinical scenario that continuously challenges physicians. An endovascular option is in situ laser fenestrated endografts. One risk with these is the complete visceral ischemia occurring before the fenestrations are completed. An off-the-shelf single-fenestrated stent graft facilitates the treatment by removing the ischemia time for the SMA and reducing the ischemia time for the celiac and renal arteries thus decreasing the risk of visceral ischemia complications.

3.
J Vasc Surg ; 78(3): 575-583.e2, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37105333

RESUMO

OBJECTIVE: A common measure to lower the risk for spinal cord ischemia (SCI) during complex endovascular aortic repair (cEVAR) is prophylactic cerebrospinal fluid drainage (CSFD). This method has caused controversy because of drain-related complications. Spinal drains are usually pressure directed. The objective of this study was to evaluate the risk of CSFD-related complications and SCI within the context of an automated volume-directed drain protocol. METHODS: This is a retrospective, single-center study of all cEVARs with CSFD at a tertiary vascular center between January 2014 and December 2020. Demographics, complications, and spinal drain data were recorded. All drainages were volume based using an automatic drainage system (LiquoGuard7; Möller Medical GmbH). Spinal drain complications were categorized as disabling and nondisabling according to the modified Rankin scale. The primary end point was any CSFD-related complication. RESULTS: A total of 448 cEVAR patients were identified, of whom 147 (32.8%) had prophylactic CSFD. The mean age was 69 years (63% male). The most common pathology (61%) was thoracoabdominal aortic aneurysm, and the most common procedure was branched EVAR (55.1%). Eighteen (12.2%) patients developed a CSFD-related complication, whereof three (2%) were disabling. Nineteen (13%) patients developed SCI: 12 (8.4%) paraparetic, 5 (3.4%) paraplegic, and 2 (1.4%) paresthesias. Of these, 13 (68%) had full reversal of symptoms, whereas 6 patients (4%) had residual symptoms and were deemed disabling. Drain-related complications were more common in patients with SCI (31.6%) compared with those without (9.4%, P = .014). In the latter group, only two patients (1.6%) developed a disabling drain-related complication. CONCLUSIONS: Selective use of prophylactic, automated volume-directed CSFD in patients at high risk for SCI was associated with a high incidence of complications and should be used with caution. Among those developing SCI, reversal was achieved frequently with increased CSFD volume, but at the price of more bleeding complications.


Assuntos
Aneurisma da Aorta Torácica , Procedimentos Endovasculares , Isquemia do Cordão Espinal , Humanos , Masculino , Idoso , Feminino , Aneurisma da Aorta Torácica/cirurgia , Correção Endovascular de Aneurisma , Estudos Retrospectivos , Fatores de Risco , Paraplegia/diagnóstico , Paraplegia/etiologia , Paraplegia/prevenção & controle , Isquemia do Cordão Espinal/diagnóstico , Isquemia do Cordão Espinal/etiologia , Isquemia do Cordão Espinal/prevenção & controle , Vazamento de Líquido Cefalorraquidiano/complicações , Procedimentos Endovasculares/efeitos adversos , Resultado do Tratamento
4.
Ann Vasc Surg ; 78: 141-151, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34175417

RESUMO

INTRODUCTION: Ischemic spinal cord injury (SCI) is a serious complication of complex aortic repair. Prophylactic cerebrospinal fluid (CSF) drainage, used to decrease lumbar cerebrospinal fluid (CSF) pressure, enables monitoring of CSF biomarkers that may aid in detecting impending SCI. We hypothesized that biomarkers, previously evaluated in traumatic SCI and brain injury, would be altered in CSF over time following complex endovascular aortic repair (cEVAR). OBJECTIVES: To examine if a chosen cohort of CSF biomarker correlates to SCI and warrants further research. METHODS: A prospective observational study on patients undergoing cEVAR with extensive aortic coverage. Vital parameters and CSF samples were collected on ten occasions during 72 hours post-surgery. A panel of ten biomarkers were analyzed (Neurofilament Light Polypeptide (NFL), Tau, Glial Fibrillary Acidic Protein (GFAP), Soluble Amyloid Precursos Protein (APP) α and ß, Amyloid ß 38, 40 and 42 (Aß38, 40 and 42), Chitinase-3-like protein 1 (CHI3LI or YKL-40), Heart-type fatty acid binding protein (H-FABP).). RESULTS: Nine patients (mean age 69, 7 males) were included. Median total aortic coverage was 68% [33, 98]. One patient died during the 30-day post-operative period. After an initial stable phase for the first few postoperative hours, most biomarkers showed an upward trend compared with baseline in all patients with >50% increase in value for NFL in 5/9 patients, in 7/9 patients for Tau and in 5/9 patients for GFAP. One patient developed spinal cord and supratentorial brain ischemia, confirmed with MRI. In this case, NF-L, GFAP and tau were markedly elevated compared with non-SCI patients (maximum increase compared with baseline in the SCI patient versus mean value of the maximal increase for all other patients: NF-L 367% vs 79%%, GFAP 95608% versus 3433%, tau 1020% vs 192%). CONCLUSION: This study suggests an increase in all ten studied CSF biomarkers after coverage of spinal arteries during endovascular aortic repair. However, the pilot study was not able to establish a specific correlation between spinal fluid biomarker elevation and clinical symptoms of SCI due to small sample size and event rate.


Assuntos
Aorta/cirurgia , Aneurisma Aórtico/cirurgia , Biomarcadores/líquido cefalorraquidiano , Procedimentos Endovasculares , Complicações Pós-Operatórias/prevenção & controle , Isquemia do Cordão Espinal/prevenção & controle , Adulto , Idoso , Proteínas Amiloidogênicas/líquido cefalorraquidiano , Pressão do Líquido Cefalorraquidiano , Proteína 1 Semelhante à Quitinase-3/líquido cefalorraquidiano , Proteínas de Ligação a Ácido Graxo/líquido cefalorraquidiano , Feminino , Proteína Glial Fibrilar Ácida/líquido cefalorraquidiano , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Prognóstico , Estudos Prospectivos , Isquemia do Cordão Espinal/etiologia , Proteínas tau/líquido cefalorraquidiano
5.
Laeknabladid ; 104(10): 439-441, 2018.
Artigo em Islandês | MEDLINE | ID: mdl-30256214

RESUMO

In this case report we describe a patient with a confirmed diagnosis of Peutz-Jegher syndrome. A diagnosis made from a positive tissue sample from the small bowels and characteristic hyperpigmentation on the patient's lips. This particular patient wasn't diagnosed till he got intussusception which required an operation. There's a possibility that the diagnosis could have been made earlier in the patient's life because of the hyperpigmented macules on his lips in addition to frequent abdominal pain.


Assuntos
Intussuscepção/etiologia , Síndrome de Peutz-Jeghers/complicações , Humanos , Intussuscepção/diagnóstico por imagem , Intussuscepção/cirurgia , Masculino , Síndrome de Peutz-Jeghers/diagnóstico , Tomografia Computadorizada por Raios X , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...