Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
6.
J Appl Clin Med Phys ; 23(8): e13718, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35829667

RESUMO

Qualified medical physicists (QMPs) are in a unique position to influence the creation and application of key performance indicators (KPIs) across diverse practices in health care. Developing KPIs requires the involvement of stakeholders in the area of interest. Fundamentally, KPIs should provide actionable information for the stakeholders using or viewing them. During development, it is important to strongly consider the underlying data collection for the KPI, making it automatic whenever possible. Once the KPI has been validated, it is important to setup a review cycle and be prepared to adjust the underlying data or action levels if the KPI is not performing as intended. Examples of specific KPIs for QMPs of common scopes of practice are provided to act as models to aid in implementation. KPIs are a useful tool for QMPs, regardless of the scope of practice or practice environment, to enhance the safety and quality of care being delivered.


Assuntos
Indicadores de Qualidade em Assistência à Saúde , Humanos
7.
J Appl Clin Med Phys ; 23(7): e13664, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35699199

RESUMO

There is no current authoritative accounting of the number of clinical imaging physicists practicing in the United States. Information about the workforce is needed to inform future efforts to secure training pathways and opportunities. In this study, the AAPM Diagnostic Demand and Supply Projection Working Group collected lists of medical physicists from several state registration and licensure programs and the Conference of Radiation Control Program Directors (CRCPD) registry. By cross-referencing individuals among these lists, we were able to estimate the current imaging physics workforce in the United States by extrapolating based on population. The imaging physics workforce in the United States in 2019 consisted of approximately 1794 physicists supporting diagnostic X-ray (1073 board-certified) and 934 physicists supporting nuclear medicine (460 board-certified), with a number of individuals practicing in both subfields. There were an estimated 235 physicists supporting nuclear medicine exclusively (150 board-certified). The estimated total workforce, accounting for overlap, was 2029 medical physicists. These estimates are in approximate agreement with other published studies of segments of the workforce.


Assuntos
Radioterapia (Especialidade) , Diagnóstico por Imagem , Física Médica/educação , Humanos , Física , Radioterapia (Especialidade)/educação , Radiografia , Estados Unidos , Recursos Humanos
8.
Inflamm Bowel Dis ; 28(9): 1357-1362, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-34935946

RESUMO

BACKGROUND: Patients with inflammatory bowel disease (IBD) frequently undergo multiple computed tomography (CT) examinations. With the widespread availability of magnetic resonance imaging (MRI), it is unclear whether the use of CTs in IBD has declined. We aimed to analyze the trends of CT and MRI use in a large cohort of IBD patients in a 10-year period. METHODS: We retrospectively analyzed adults ≥18 years of age using a de-identified database, IBM Explorys. Patients with ≥1 CT of the abdomen (± pelvis) or MRI of the abdomen (± pelvis) at least 30 days after the diagnosis of Crohn's disease (CD) or ulcerative colitis (UC) were included. We examined the factors associated with patients undergoing multiple CTs (≥5 CTs of the abdomen) and performed a trend analysis from 2010 to 2019. RESULTS: Among 176 110 CD and 143 460 UC patients, those with ≥1 CT of the abdomen annually increased from 2010 to 2019 with mean annual percentage change of +3.6% for CD and +4.9% for UC. Similarly, annual percentage change for patients with ≥1 MRI (CD: +15.6%; UC: +22.8%) showed a rising trend. There was a 3.8% increase in CD patients receiving ≥5 CTs of the abdomen annually compared with a 2.4% increase among UC patients in the 10-year period. Age ≥50 years, men, African Americans, public insurance payors, body mass index ≥30kg/m2, and smoking history were associated with ≥5 CTs. CONCLUSIONS: There is a considerable increase in the number of CT scans performed in IBD patients. Further studies can explore factors influencing the use of CT and MRI of the abdomen in IBD patients.


The proportion of inflammatory bowel disease patients with ≥5 computed tomographies of the abdomen annually has increased by 2.4%-3.8% from 2010 to 2019. Age ≥50 years, men, African Americans, public insurance payors, body mass index ≥30kg/m2, and smoking history were associated with ≥5 computed tomographies of the abdomen annually.


Assuntos
Colite Ulcerativa , Doença de Crohn , Doenças Inflamatórias Intestinais , Abdome/diagnóstico por imagem , Adulto , Colite Ulcerativa/diagnóstico , Doença de Crohn/diagnóstico , Humanos , Doenças Inflamatórias Intestinais/diagnóstico por imagem , Doenças Inflamatórias Intestinais/etiologia , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/efeitos adversos
13.
Med Phys ; 48(8): 4523-4531, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34231224

RESUMO

The past decade has seen the increasing integration of magnetic resonance (MR) imaging into radiation therapy (RT). This growth can be contributed to multiple factors, including hardware and software advances that have allowed the acquisition of high-resolution volumetric data of RT patients in their treatment position (also known as MR simulation) and the development of methods to image and quantify tissue function and response to therapy. More recently, the advent of MR-guided radiation therapy (MRgRT) - achieved through the integration of MR imaging systems and linear accelerators - has further accelerated this trend. As MR imaging in RT techniques and technologies, such as MRgRT, gain regulatory approval worldwide, these systems will begin to propagate beyond tertiary care academic medical centers and into more community-based health systems and hospitals, creating new opportunities to provide advanced treatment options to a broader patient population. Accompanying these opportunities are unique challenges related to their adaptation, adoption, and use including modification of hardware and software to meet the unique and distinct demands of MR imaging in RT, the need for standardization of imaging techniques and protocols, education of the broader RT community (particularly in regards to MR safety) as well as the need to continue and support research, and development in this space. In response to this, an ad hoc committee of the American Association of Physicists in Medicine (AAPM) was formed to identify the unmet needs, roadblocks, and opportunities within this space. The purpose of this document is to report on the major findings and recommendations identified. Importantly, the provided recommendations represent the consensus opinions of the committee's membership, which were submitted in the committee's report to the AAPM Board of Directors. In addition, AAPM ad hoc committee reports differ from AAPM task group reports in that ad hoc committee reports are neither reviewed nor ultimately approved by the committee's parent groups, including at the council and executive committee level. Thus, the recommendations given in this summary should not be construed as being endorsed by or official recommendations from the AAPM.


Assuntos
Imageamento por Ressonância Magnética , Radioterapia Guiada por Imagem , Humanos , Aceleradores de Partículas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Estados Unidos
15.
Med Phys ; 48(2): e31-e35, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33320364

RESUMO

PURPOSE: A Positron Emission Tomography/Computed Tomography quality assurance program is necessary to ensure that patients receive optimal imaging and care. We summarize the AAPM Task Group (TG) 126 report on acceptance and quality assurance (QA) testing of PET/CT systems. METHODS: TG 126 was charged with developing PET/CT acceptance testing and QA procedures. The TG aimed to develop procedures that would allow for standardized evaluation of existing short-axis cylindrical-bore PET/CT systems in the spirit of NEMA NU 2 standards without requiring specialized phantoms or proprietary software tools. RESULTS: We outline eight performance evaluations using common phantoms and freely available software whereby the clinical physicist monitors each PET/CT system by comparing periodic Follow-Up Measurements to Baseline Measurements acquired during acceptance testing. For each of the eight evaluations, we also summarize the expected testing time and materials necessary and the recommended pass/fail criteria. CONCLUSION: Our report provides a guideline for periodic evaluations of most clinical PET/CT systems that simplifies procedures and requirements outlined by other agencies and will facilitate performance comparisons across vendors, models, and institutions.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Software , Humanos , Imagens de Fantasmas
16.
J Thorac Imaging ; 35(3): W75-W81, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32032249

RESUMO

The chest radiograph is the most frequently performed imaging in radiology and by including the heart and central vessels can suggest the presence of cardiovascular disease. Dual-energy subtraction radiography of the chest provides improved detection of a wide variety of cardiovascular pathologies including coronary artery disease, valvular pathologies, and pericardial disease given the presence of calcification in many subtypes of these diseases. We review the principles of dual-energy subtraction radiography and demonstrate its added value in the assessment of cardiovascular disease.


Assuntos
Doenças Cardiovasculares/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Radiografia Torácica/métodos , Humanos
18.
Med Phys ; 46(8): 3520-3531, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31063248

RESUMO

PURPOSE: Accurate photon attenuation assessment from MR data remains an unmet challenge in the thorax due to tissue heterogeneity and the difficulty of MR lung imaging. As thoracic tissues encompass the whole physiologic range of photon absorption, large errors can occur when using, for example, a uniform, water-equivalent or a soft-tissue-only approximation. The purpose of this study was to introduce a method for voxel-wise thoracic synthetic CT (sCT) generation from MR data attenuation correction (AC) for PET/MR or for MR-only radiation treatment planning (RTP). METHODS: Acquisition: A radial stack-of-stars combining ultra-short-echo time (UTE) and modified Dixon (mDixon) sequence was optimized for thoracic imaging. The UTE-mDixon pulse sequence collects MR signals at three TE times denoted as UTE, Echo1, and Echo2. Three-point mDixon processing was used to reconstruct water and fat images. Bias field correction was applied in order to avoid artifacts caused by inhomogeneity of the MR magnetic field. ANALYSIS: Water fraction and R2* maps were estimated using the UTE-mDixon data to produce a total of seven MR features, that is UTE, Echo1, Echo2, Dixon water, Dixon fat, Water fraction, and R2*. A feature selection process was performed to determine the optimal feature combination for the proposed automatic, 6-tissue classification for sCT generation. Fuzzy c-means was used for the automatic classification which was followed by voxel-wise attenuation coefficient assignment as a weighted sum of those of the component tissues. Performance evaluation: MR data collected using the proposed pulse sequence were compared to those using a traditional two-point Dixon approach. Image quality measures, including image resolution and uniformity, were evaluated using an MR ACR phantom. Data collected from 25 normal volunteers were used to evaluate the accuracy of the proposed method compared to the template-based approach. Notably, the template approach is applicable here, that is normal volunteers, but may not be robust enough for patients with pathologies. RESULTS: The free breathing UTE-mDixon pulse sequence yielded images with quality comparable to those using the traditional breath holding mDixon sequence. Furthermore, by capturing the signal before T2* decay, the UTE-mDixon image provided lung and bone information which the mDixon image did not. The combination of Dixon water, Dixon fat, and the Water fraction was the most robust for tissue clustering and supported the classification of six tissues, that is, air, lung, fat, soft tissue, low-density bone, and dense bone, used to generate the sCT. The thoracic sCT had a mean absolute difference from the template-based (reference) CT of less than 50 HU and which was better agreement with the reference CT than the results produced using the traditional Dixon-based data. CONCLUSION: MR thoracic acquisition and analyses have been established to automatically provide six distinguishable tissue types to generate sCT for MR-based AC of PET/MR and for MR-only RTP.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Tórax/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Análise por Conglomerados , Humanos
19.
J Clin Densitom ; 22(3): 374-381, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30497869

RESUMO

INTRODUCTION: Bone mineral density (BMD) analysis by Dual-Energy x-ray Absorptiometry (DXA) can have some false negatives due to overlapping structures in the projections. Spectral Detector CT (SDCT) can overcome these limitations by providing volumetric information. We investigated its performance for BMD assessment and compared it to DXA and phantomless volumetric bone mineral density (PLvBMD), the latter known to systematically underestimate BMD. DXA is the current standard for BMD assessment, while PLvBMD is an established alternative for opportunistic BMD analysis using CT. Similarly to PLvBMD, spectral data could allow BMD screening opportunistically, without additional phantom calibration. METHODOLOGY: Ten concentrations of dipotassium phosphate (K2HPO4) ranging from 0 to 600 mg/ml, in an acrylic phantom were scanned using SDCT in four different, clinically-relevant scan conditions. Images were processed to estimate the K2HPO4 concentrations. A model representing a human lumbar spine (European Spine Phantom) was scanned and used for calibration via linear regression analysis. After calibration, our method was retrospectively applied to abdominal SDCT scans of 20 patients for BMD assessment, who also had PLvBMD and DXA. Performance of PLvBMD, DXA and our SDCT method were compared by sensitivity, specificity, negative predictive value and positive predictive value for decreased BMD. RESULTS: There was excellent correlation (R2 >0.99, p < 0.01) between true and measured K2HPO4 concentrations for all scan conditions. Overall mean measurement error ranged from -11.5 ± 4.7 mg/ml (-2.8 ± 6.0%) to -12.3 ± 6.3 mg/ml (-4.8 ± 3.0%) depending on scan conditions. Using DXA as a reference standard, sensitivity/specificity for detecting decreased BMD in the scanned patients were 100%/73% using SDCT, 100%/40% using PLvBMD provided T-scores, and 90-100%/40-53% using PLvBMD hydroxyapatite density classifications, respectively. CONCLUSIONS: Our results show excellent sensitivity and high specificity of SDCT for detecting decreased BMD, demonstrating clinical feasibility. Further validation in prospective clinical trials will be required.


Assuntos
Densidade Óssea , Vértebras Lombares/diagnóstico por imagem , Osteoporose/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Absorciometria de Fóton , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Vértebras Lombares/patologia , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Osteoporose/patologia , Imagens de Fantasmas , Fosfatos , Compostos de Potássio
20.
J Am Coll Radiol ; 16(2): 236-239, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30245216

RESUMO

The ACR Dose Index Registry (DIR) provides a new source of clinical radiation exposure data that has not been used previously to establish or update the relative radiation level (RRL) values in the ACR Appropriateness Criteria (AC). The results of a recent review of DIR data for 10 common CT examinations were compared with current ACR AC RRL values for the same procedures. The AC RRL values were previously determined by consensus of members of the AC Radiation Exposure Subcommittee based on reference radiation dose values from the literature (when available) and anecdotal information from individual members' clinical practices and experiences. For 7 of the 10 examination types reviewed, DIR data agreed with existing RRL values. For 3 of 10 examination types, DIR data reflected lower dose values than currently rated in the AC. The Radiation Exposure Subcommittee will revise these RRL assignments in a forthcoming update to the AC (in October 2018) and will continue to monitor the DIR and associated reviews and analyses to refine RRL assignments for additional examination types. Given recent attention and efforts to reduce radiation exposure in CT and other imaging modalities, it is likely that other examination types will require revision of RRL assignments once information from the DIR database is considered.


Assuntos
Diagnóstico por Imagem/normas , Monitoramento de Radiação/normas , Sistema de Registros , Sociedades Médicas , Adulto , Humanos , Doses de Radiação , Exposição à Radiação/normas , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...