Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-37995962

RESUMO

OBJECTIVE: This study aimed to assess aneurysm sac dynamics and its prognostic significance following fenestrated and branched endovascular aneurysm repair (F/BEVAR). METHODS: Patients undergoing F/BEVAR for degenerative complex aortic aneurysm from 2008 to 2020 at two large vascular centres with two imaging examinations (30 day and one year) were included. Patients were categorised as regression and non-regression, determined by the proportional volume change (> 5%) at one year compared with 30 days. All cause mortality and freedom from graft related events were assessed using Kaplan-Meier methods. Factors associated with non-regression at one year and aneurysm sac volume over time were examined for FEVAR and BEVAR independently using multivariable logistic regression and linear mixed effects modelling. RESULTS: One hundred and sixty-five patients were included: 122 FEVAR, of whom 34% did not regress at one year imaging (20% stable, 14% expansion); and 43 BEVAR, of whom 53% failed to regress (26% stable, 28% expansion). Following F/BEVAR, after risk adjusted analysis, non-regression was associated with higher risk of all cause mortality within five years (hazard ratio [HR] 2.56, 95% confidence interval [CI] 1.09 - 5.37; p = .032) and higher risk of graft related events within five years (HR 2.44, 95% CI 1.10 - 5.26; p = .029). Following multivariable logistic regression, previous aortic repair (odds ratio [OR] 2.56, 95% CI 1.11 - 5.96; p = .029) and larger baseline aneurysm diameter (OR/mm 1.04, 95% CI 1.00 - 1.09; p = .037) were associated with non-regression at one year, whereas smoking history was inversely associated with non-regression (OR 0.21, 95% CI 0.04 - 0.96; p = .045). Overall following FEVAR, aneurysm sac volume decreased significantly up to two years (baseline vs. two year, 267 [95% CI 250 - 285] cm3vs. 223 [95% CI 197 - 248] cm3), remaining unchanged thereafter. Overall following BEVAR, aneurysm sac volume remained stable over time. CONCLUSION: Like infrarenal EVAR, non-regression at one year imaging is associated with higher five year all cause mortality and graft related events risks after F/BEVAR. Following FEVAR for juxtarenal aortic aneurysm, aneurysm sacs generally displayed regression (66% at one year), whereas after BEVAR for thoraco-abdominal aortic aneurysm, aneurysm sacs displayed a concerning proportion of growth at one year (28%), potentially suggesting a persistent risk of rupture and consequently requiring intensified surveillance following BEVAR. Future studies will have to elucidate how to improve sac regression following complex EVAR, and whether the high expansion risk after BEVAR is due to advanced disease extent.

3.
Eur J Vasc Endovasc Surg ; 59(5): 740-747, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32115359

RESUMO

OBJECTIVE: Long term survival after endovascular aortic aneurysm repair (EVAR) in octogenarians remains unclear. This was evaluated by comparing octogenarians after EVAR with a matched group of octogenarians without an abdominal aortic aneurysm (AAA) from the Rotterdam Study (RS). The influence of complications after EVAR on survival was also studied with the aim of identifying risk factors for the development of complications in octogenarians. METHODS: Using propensity score matching (PSM), 83 EVAR octogenarians were matched for comorbidities with 83 octogenarians from the RS, and survival was compared between these two groups using Cox proportional hazard analysis. Then, complications were studied, defined as cardiac or pulmonary, renal deterioration, access site bleeding, acute limb ischaemia or bowel ischaemia, within 30 days of surgery between 83 EVAR octogenarians and 475 EVAR non-octogenarians. Also, the difference in baseline characteristics between the octogenarians with and without complications after EVAR were studied, and survival was compared between the RS controls and the complicated and uncomplicated EVAR octogenarians separately. RESULTS: The total EVAR octogenarian population did not show an increased mortality risk compared with RS octogenarian controls (hazard ratio [HR] 1.28, 95% confidence interval [CI] 0.84-1.97). Post-operative complications occurred in 22 octogenarians (27%) and 59 non-octogenarians (12.4%, p < .001), mainly cardiac, pulmonary, and bleeding complications. All baseline characteristics were similar in the complicated EVAR octogenarians compared with the uncomplicated EVAR octogenarians. After uncomplicated EVAR, octogenarians had a similar survival compared with the RS controls (HR 1.09, 95% CI 0.68-1.77), but after complicated EVAR their mortality risk increased significantly (HR 1.93, 95% CI 1.06-3.54). CONCLUSION: After standard EVAR, the life expectancy of octogenarians is the same as that of a matched group from the general population without an AAA, provided they do not develop early post-operative complications. Patient selection and meticulous peri-operative care are key.


Assuntos
Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Abdominal/cirurgia , Procedimentos Endovasculares , Fatores Etários , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/epidemiologia , Taxa de Sobrevida
4.
J Vasc Surg ; 69(3): 783-791, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30292614

RESUMO

OBJECTIVE: Standard endovascular aneurysm repair (EVAR) is the most common treatment of abdominal aortic aneurysms (AAAs). EVAR has been increasingly used in patients with hostile neck features. This study investigated the outcomes of EVAR in patients with neck diameters ≥30 mm in the prospectively maintained Endurant Stent Graft Natural Selection Global Postmarket Registry (ENGAGE). METHODS: This is a retrospective study comparing patients with neck diameters ≥30 mm with patients with neck diameters <30 mm. The primary end point was type IA endoleak (EL1A). Secondary end points included secondary interventions to correct EL1A, aneurysm rupture, and survival. RESULTS: This study included 1257 patients (mean age, 73.1 years; 89.4% male) observed for a median 4.0 years (interquartile range, 2.7-4.8 years). A total of 97 (7.7%) patients had infrarenal neck diameters ≥30 mm and were compared with the remaining 1160 (92.3%) with neck diameters <30 mm. At baseline, there were no differences between groups regarding demographics and comorbidities other than cardiac disease, which was more frequent in the ≥30-mm neck diameter group (P = .037). There were no significant differences between the groups regarding neck length, angulation, thrombus, or calcification. Mean preoperative AAA diameter was 64.6 ± 11.3 mm in the ≥30-mm neck diameter group and 60.0 ± 11.6 mm in the <30-mm neck diameter group (P < .001). Stent graft oversizing was significantly less in the ≥30-mm neck diameter group (12.2% ± 8.9% vs 22.1% ± 11.9%; P <. 001). Five patients (5.2%) in the ≥30-mm neck diameter group and 30 (2.6%) with neck diameters <30 mm developed EL1A, yielding a 4-year freedom from EL1A of 92.4% vs 96.6%, respectively (P = .09). Oversizing was 21.8% ± 13.0% for patients developing EL1A and 21.3% ± 12.4% for the remaining cohort (P = .99). In adjusting for neck length, AAA diameter, and device oversizing, patients with neck diameter ≥30 mm were at greater risk for development of EL1A (hazard ratio, 3.0; 95% confidence interval, 1.0-9.3; P = .05). Secondary interventions due to EL1A did not differ between groups (P = .36). AAA rupture occurred in three patients with neck diameter ≥30 mm (3.1%) and in eight patients with neck diameter <30 mm (0.7%; hazard ratio, 5.1; 95% confidence interval, 1.4-19.2; P = .016); two cases were EL1A related in each group. At 4 years, overall survival was 61.6% for the ≥30-mm neck diameter group and 75.2% for the <30-mm neck diameter group (P = .009), which remained significant on correcting for sex and AAA diameter (P = .016). CONCLUSIONS: In this study, patients with infrarenal neck diameter ≥30 mm had a threefold increased risk of EL1A and fivefold risk of aneurysm rupture after EVAR as well as worse overall survival. This may influence the choice of AAA repair and underlines the need for regular computed tomography-based imaging surveillance in this subset of patients. Furthermore, these results can serve as standards with which new, possibly improved technology, such as EndoAnchors (Medtronic, Santa Rosa, Calif), can be compared.


Assuntos
Aneurisma Aórtico/cirurgia , Ruptura Aórtica/etiologia , Implante de Prótese Vascular/efeitos adversos , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Aneurisma Aórtico/complicações , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/mortalidade , Ruptura Aórtica/diagnóstico por imagem , Ruptura Aórtica/mortalidade , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Endoleak/diagnóstico por imagem , Endoleak/mortalidade , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Vigilância de Produtos Comercializados , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Stents , Fatores de Tempo , Resultado do Tratamento
5.
J Vasc Surg ; 68(6): 1725-1735, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-29914837

RESUMO

OBJECTIVE: Severe neck angulation is associated with complications after endovascular aneurysm repair (EVAR). Newer endografts may overcome this limitation, but the literature lacks long-term results. We studied the long-term outcomes of EVAR in patients with severe neck angulation. METHODS: A retrospective case-control study of a prospective multicenter database was performed. All measurements were made with dedicated software with center lumen line reconstruction. A study group including patients with neck length >15 mm, infrarenal angle (ß) >75 degrees or suprarenal angle (α) >60 degrees, and neck length 10 to 15 mm with ß >60 degrees or α >45 degrees was compared with a control group matched for demographics and other morphologic neck features. The primary end point was type IA endoleak (EL1A). Secondary end points were freedom from neck-related secondary interventions, primary clinical success, and overall survival. RESULTS: Forty-five patients were included in the angulated neck group and compared with 65 matched patients. Median follow-up was 7.4 years (interquartile range, 4.8-8.5 years). In the angulated neck group, mean α was 51.4 degrees (±21.1 degrees) and the mean ß was 80.8 degrees (±15.6 degrees); in the nonangulated group, these were 17.9 degrees (±17.0 degrees) and 35.4 degrees (±20.0 degrees), respectively. At 7 years, five patients in the angulated neck group and two nonangulated patients developed EL1A, yielding a freedom from EL1A of 86.1% (n = 14; standard error [SE], 0.069) and 96.6% (n = 34; SE, 0.023), respectively (P = .056). After exclusion of a patient who developed an EL1A secondary to an endograft infection, this difference was significant: 86.1% (n = 14; SE, 0.069) in the angulated neck group and 98.2% (n = 34; SE, 0.018) in the nonangulated group (P = .016). At 7 years, freedom from neck-related secondary interventions was 91.7% (n = 14; SE, 0.059) and 91.6% (n = 29; SE, 0.029), respectively. The 7-year primary clinical success estimates were 41.2% (n = 11; SE, 0.085) and 56.6% (n = 20; SE, 0.072) for the angulated neck and nonangulated groups, respectively (P = .12). The 7-year survival rates were 44.3% (n = 18; SE, 0.076) vs 66.7% (n = 42; SE, 0.059) for the angulated neck and nonangulated groups, respectively (P = .25). Device integrity failure was not observed. CONCLUSIONS: Despite satisfactory results early and in the midterm, a higher rate of EL1A was identified among patients with severely angulated necks in the long term. However, mortality was not affected by this difference. These findings suggest that EVAR should be used judiciously in patients with extreme angulation of the proximal neck and highlight the need for close follow-up of EVAR, especially in the long term and in patients treated outside instructions for use.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Aortografia/métodos , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Angiografia por Tomografia Computadorizada , Bases de Dados Factuais , Endoleak/etiologia , Endoleak/mortalidade , Endoleak/cirurgia , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Stents , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...