Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
1.
J Card Fail ; 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38754697

RESUMO

BACKGROUND: Living with a left ventricular assist device (LVAD) comes with potentially burdensome aspects posed by, for example, battery packs and device drivelines. We aim to describe the impact of living with a durable LVAD on sexual quality of life (QOL), depression, and anxiety in patients and their partners. METHODS AND RESULTS: In this single-center, prospective, observational study, patients ≥4 months after LVAD implantation and their partners completed the Sexual Activities in Left Ventricular Assist Device Patients or Partners questionnaire to assess their sexual QOL, the 8-item Patient Health Questionnaire (PHQ-8) to assess symptoms of depression and the 7-item Generalized Anxiety Disorder (GAD-7) to assess symptoms of anxiety. Sixty patients and 60 partners completed the questionnaires 2.3 ± 1.9 years after implantation. Eighty-seven percent of the patients and 13% of partners were male. The mean age of patients was 57.4 ± 13.3 years, with 90% living with their partner. Ten percent of patients and 18% of partners had a current diagnosis of a psychological condition, most frequently depression and/or anxiety. Overall, 49% of participants indicated the LVAD influenced their sexual activity (patients 53% vs partners 45%; P = .33). Disturbances from the driveline were the most common problem indicated. Twenty-four percent of participants had scored in the mild to moderate depression range on the PHQ-8 and 28% scored in the mild to severe anxiety range on the GAD-7. The median total GAD-7 (1 [interquartile range (IQR) 0-4.25] vs 2.5 [IQR 0-5]; P = .06) were comparable between patients and partners; whereas patients had a higher total PHQ-8 score (3 [IQR 0-5.25] vs 1 [IQR 0-3.25]; P = .02). A preference to receive information regarding sexuality while on LVAD support was indicated by 54% of participants and did not differ between patients and partners (P > .99). Written resources were the most commonly preferred source of information. CONCLUSIONS: LVADs severely affect the sexual QOL for patients and their partners. The presence of a driveline is a major cause for concern. Patients prefer receiving written information on how to improve their sexual QOL.

2.
J Card Fail ; 29(7): 1046-1055, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36958391

RESUMO

BACKGROUND: Left ventricular (LV) volume reshaping reduces myocardial wall stress and may induce reverse remodeling in patients with heart failure with reduced ejection fraction. The AccuCinch Transcatheter Left Ventricular Restoration system consists of a series of anchors connected by a cable implanted along the LV base that is cinched to the basal free wall radius. We evaluated the echocardiographic and clinical outcomes following transcatheter left ventricular restoration. METHODS AND RESULTS: We analyzed 51 heart failure patients with a left ventricular ejection fraction between 20% and 40%, with no more than 2+ mitral regurgitation treated with optimal medical therapy, who subsequently underwent transcatheter left ventricular restoration. Serial echocardiograms, Kansas City Cardiomyopathy Questionnaire scores, and 6-minute walk test distances were measured at baseline through 12 months. Primary analysis end point was change in end-diastolic volume at 12 months compared with baseline. Patients (n = 51) were predominantly male (86%) with a mean age of 56.3 ± 13.1 years. Fluoroscopy showed LV free wall radius decreased by a median of 9.2 mm amounting to a 29.6% decrease in the free wall arc length. At 12 months, the LV end-diastolic volume decreased by 33.6 ± 34.8 mL (P < .01), with comparable decreases in the LV end-systolic volume. These decreases were associated with significant improvements in the overall Kansas City Cardiomyopathy Questionnaire score (16.4 ± 18.7 points; P < .01) and 6-minute hall walk test distance (45.9 ± 83.9 m; P < .01). There were no periprocedural deaths; through the 1-year follow-up, 1 patient died (day 280) and 1 patient received a left ventricular assist device (day 13). CONCLUSIONS: In patients with heart failure with reduced ejection fraction without significant mitral regurgitation receiving optimal medical therapy, the AccuCinch System resulted in decreases of LV volume, as well as improved quality of life and exercise endurance. A randomized trial is ongoing (NCT04331769).


Assuntos
Cardiomiopatias , Insuficiência Cardíaca , Insuficiência da Valva Mitral , Disfunção Ventricular Esquerda , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Qualidade de Vida , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda , Remodelação Ventricular
4.
N Engl J Med ; 387(1): 35-44, 2022 07 07.
Artigo em Inglês | MEDLINE | ID: mdl-35731912

RESUMO

A 57-year-old man with nonischemic cardiomyopathy who was dependent on venoarterial extracorporeal membrane oxygenation (ECMO) and was not a candidate for standard therapeutics, including a traditional allograft, received a heart from a genetically modified pig source animal that had 10 individual gene edits. Immunosuppression was based on CD40 blockade. The patient was weaned from ECMO, and the xenograft functioned normally without apparent rejection. Sudden diastolic thickening and failure of the xenograft occurred on day 49 after transplantation, and life support was withdrawn on day 60. On autopsy, the xenograft was found to be edematous, having nearly doubled in weight. Histologic examination revealed scattered myocyte necrosis, interstitial edema, and red-cell extravasation, without evidence of microvascular thrombosis - findings that were not consistent with typical rejection. Studies are under way to identify the mechanisms responsible for these changes. (Funded by the University of Maryland Medical Center and School of Medicine.).


Assuntos
Animais Geneticamente Modificados , Transplante de Coração , Xenoenxertos , Transplante Heterólogo , Animais , Animais Geneticamente Modificados/genética , Oxigenação por Membrana Extracorpórea , Coração , Transplante de Coração/métodos , Humanos , Terapia de Imunossupressão , Suínos , Transplante Heterólogo/métodos
5.
Front Cardiovasc Med ; 9: 893327, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35557521

RESUMO

Right heart failure is a major cause of morbidity and mortality following left ventricular assist device implantation. Over the past few decades, the definition proposed by the Interagency Registry of Mechanical Circulatory Support and Society of Thoracic Surgeons has continually evolved to better identify this complex pathology. We propose that the latest definition proposed by the Mechanical Circulatory Support Academic Research Consortium in 2020 will increase our recognition and understanding of this complex disease phenomenon.

6.
J Cardiothorac Vasc Anesth ; 36(8 Pt A): 2303-2312, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-34774406

RESUMO

OBJECTIVES: Acute kidney injury (AKI) remains a leading source of morbidity and mortality after cardiothoracic surgery. Insulin-like growth factor-binding protein 7 (IGFBP7), and tissue inhibitor of metalloproteinases-2 (TIMP-2), are novel early-phase renal biomarkers that have been validated as sensitive predictors of AKI. Here the authors studied the efficacy of these biomarkers for predicting AKI after left ventricular assist device (LVAD) implantation and cardiac transplantation. DESIGN/SETTING/PARTICIPANTS/INTERVENTIONS: This was a prospective study of 73 patients undergoing LVAD implantation (n = 37) or heart transplant (n = 36) from 2016 to 2017 at the authors' center. TIMP-2 and IGFBP7 were measured with the NephroCheck Test on urine samples before surgery and one-to-six hours after surgery. NephroCheck scores were assessed as predictors of moderate/severe AKI (Kidney Disease International Global Outcomes 2/3 creatinine criteria) within 48 hours of surgery, and the association with survival to one year was investigated. MEASUREMENTS AND MAIN RESULTS: The LVAD and transplant cohorts overall were similar in demographics and baseline creatinine (p > 0.05), with the exception of having more African-American patients in the LVAD arm (p = 0.003). Eleven (30%) LVAD and 16 (44%) transplant patients developed moderate/severe AKI. Overall, AKI was associated with postsurgery NephroCheck (odds ratio [95% confidence interval] for 0.1 mg/dL increase: 1.36 [1.04-1.79]; p = 0.03), but not with baseline NephroCheck (p = 0.92). When analyzed by cohort, this effect remained for LVAD (1.68 [1.05-2.71]; p = 0.03) but not for transplant (p = 0.15). Receiver operating characteristic analysis showed postoperative NephroCheck to be superior to baseline creatinine in LVAD (p = 0.046). Furthermore, an increase of 0.1 mg/dL in postoperative NephroCheck was associated with a 10% increase in the risk of mortality (adjusted hazard ratio: 1.11 [1.01-1.21]; p = 0.04) independent of age and body mass index. CONCLUSION: Assessment of TIMP-2 and IGFBP7 within six hours after surgery appeared effective at predicting AKI in patients with LVADs. Larger studies are warranted to validate these findings.


Assuntos
Injúria Renal Aguda , Transplante de Coração , Coração Auxiliar , Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/epidemiologia , Injúria Renal Aguda/etiologia , Biomarcadores/urina , Pontos de Checagem do Ciclo Celular , Creatinina , Transplante de Coração/efeitos adversos , Coração Auxiliar/efeitos adversos , Humanos , Estudos Prospectivos , Inibidor Tecidual de Metaloproteinase-2/urina
7.
Nat Med ; 27(11): 1954-1960, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34711976

RESUMO

Patients with heart failure and preserved ejection fraction (HFpEF) have a high burden of symptoms and functional limitations, and have a poor quality of life. By targeting cardiometabolic abmormalities, sodium glucose cotransporter 2 (SGLT2) inhibitors may improve these impairments. In this multicenter, randomized trial of patients with HFpEF (NCT03030235), we evaluated whether the SGLT2 inhibitor dapagliflozin improves the primary endpoint of Kansas City Cardiomyopathy Questionnaire Clinical Summary Score (KCCQ-CS), a measure of heart failure-related health status, at 12 weeks after treatment initiation. Secondary endpoints included the 6-minute walk test (6MWT), KCCQ Overall Summary Score (KCCQ-OS), clinically meaningful changes in KCCQ-CS and -OS, and changes in weight, natriuretic peptides, glycated hemoglobin and systolic blood pressure. In total, 324 patients were randomized to dapagliflozin or placebo. Dapagliflozin improved KCCQ-CS (effect size, 5.8 points (95% confidence interval (CI) 2.3-9.2, P = 0.001), meeting the predefined primary endpoint, due to improvements in both KCCQ total symptom score (KCCQ-TS) (5.8 points (95% CI 2.0-9.6, P = 0.003)) and physical limitations scores (5.3 points (95% CI 0.7-10.0, P = 0.026)). Dapagliflozin also improved 6MWT (mean effect size of 20.1 m (95% CI 5.6-34.7, P = 0.007)), KCCQ-OS (4.5 points (95% CI 1.1-7.8, P = 0.009)), proportion of participants with 5-point or greater improvements in KCCQ-OS (odds ratio (OR) = 1.73 (95% CI 1.05-2.85, P = 0.03)) and reduced weight (mean effect size, 0.72 kg (95% CI 0.01-1.42, P = 0.046)). There were no significant differences in other secondary endpoints. Adverse events were similar between dapagliflozin and placebo (44 (27.2%) versus 38 (23.5%) patients, respectively). These results indicate that 12 weeks of dapagliflozin treatment significantly improved patient-reported symptoms, physical limitations and exercise function and was well tolerated in chronic HFpEF.


Assuntos
Compostos Benzidrílicos/uso terapêutico , Glucosídeos/uso terapêutico , Insuficiência Cardíaca/tratamento farmacológico , Inibidores do Transportador 2 de Sódio-Glicose/uso terapêutico , Transportador 2 de Glucose-Sódio/efeitos dos fármacos , Volume Sistólico/efeitos dos fármacos , Idoso , Compostos Benzidrílicos/efeitos adversos , Método Duplo-Cego , Exercício Físico/fisiologia , Feminino , Glucosídeos/efeitos adversos , Nível de Saúde , Humanos , Masculino , Pessoa de Meia-Idade , Placebos/administração & dosagem , Qualidade de Vida/psicologia , Transportador 2 de Glucose-Sódio/metabolismo , Inibidores do Transportador 2 de Sódio-Glicose/efeitos adversos , Inquéritos e Questionários
9.
J Cardiovasc Nurs ; 36(2): 172-184, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33306621

RESUMO

BACKGROUND: Patients with a left ventricular assist device are a unique and growing population who deserve their own valid, reliable instrument for health-related quality of life. OBJECTIVE: We developed and tested the Health-Related Quality of Life with a Left Ventricular Assist Device (QOLVAD) questionnaire. METHODS: In a prospective, descriptive study, patients from 7 sites completed the QOLVAD and comparator questionnaires. Construct validity was tested using confirmatory factor analysis. Convergent validity was tested using correlations of QOLVAD scores to well-established measures of subjective health status, depression, anxiety, and meaning/faith. Reliability and test-retest reliability were quantified. RESULTS: Patients (n = 213) were 58.7 ± 13.9 years old; 81.0% were male, 73.7% were White, and 48.0% had bridge to transplant. Questionnaires were completed at a median time of 44 weeks post ventricular assist device. The 5 QOLVAD domains had acceptable construct validity (root mean square error of approximation = 0.064, comparative and Tucker-Lewis fit indices > 0.90, weighted root mean square residual = 0.95). The total score and domain-specific scores were significantly correlated with the instruments to which they were compared. Internal consistency reliability was acceptable for all subscales (α = .79-.83) except the cognitive domain (α = .66). Unidimensional reliability for the total score was acceptable (α = .93), as was factor determinacy for multidimensional reliability (0.95). Total test-retest reliability was 0.875 (P < .001). CONCLUSION: Our analysis provided initial support for validity and reliability of the QOLVAD for total score, physical, emotional, social, and meaning/spiritual domains. The QOLVAD has potential in research and clinical settings to guide decision making and referrals; further studies are needed.


Assuntos
Coração Auxiliar , Qualidade de Vida , Adulto , Idoso , Análise Fatorial , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Psicometria , Reprodutibilidade dos Testes , Inquéritos e Questionários
11.
mSystems ; 4(4)2019 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-31387933

RESUMO

Bacterial resistance to antibiotics is a pressing health issue around the world, not only in health care settings but also in the community and environment, particularly in crowded urban populations. The aim of our work was to characterize the microbial populations in sewage and the spread of antibiotic resistance within New York City (NYC). Here, we investigated the structure of the microbiome and the prevalence of antibiotic resistance genes in raw sewage samples collected from the fourteen NYC Department of Environmental Protection wastewater treatment plants, distributed across the five NYC boroughs. Sewage, a direct output of anthropogenic activity and a reservoir of microbes, provides an ecological niche to examine the spread of antibiotic resistance. Taxonomic diversity analysis revealed a largely similar and stable bacterial population structure across all the samples, which was found to be similar over three time points in an annual cycle, as well as in the five NYC boroughs. All samples were positive for the presence of the seven antibiotic resistance genes tested, based on real-time quantitative PCR assays, with higher levels observed for tetracycline resistance genes at all time points. For five of the seven genes, abundances were significantly higher in May than in February and August. This study provides characteristics of the NYC sewage resistome in the context of the overall bacterial populations.IMPORTANCE Urban sewage or wastewater is a diverse source of bacterial growth, as well as a hot spot for the development of environmental antibiotic resistance, which can in turn influence the health of the residents of the city. As part of a larger study to characterize the urban New York City microbial metagenome, we collected raw sewage samples representing three seasonal time points spanning the five boroughs of NYC and went on to characterize the microbiome and the presence of a range of antibiotic resistance genes. Through this study, we have established a baseline microbial population and antibiotic resistance abundance in NYC sewage which can prove to be very useful in studying the load of antibiotic usage, as well as for developing effective measures in antibiotic stewardship.

12.
J Thorac Dis ; 11(Suppl 6): S864-S870, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31183166

RESUMO

BACKGROUND: Right heart failure (RHF) is a well-known consequence of left ventricular assist device (LVAD) placement, and has been linked to negative surgical outcomes. However, little is known regarding risk factors associated with RHF. This article delineates pre- and intra-operative risk factors for RHF following LVAD implantation and demonstrates the effect of RHF severity on key surgical outcomes. METHODS: We performed a retrospective analysis of consecutive LVAD patients treated at our center between 2008 and 2016. RHF was categorized using the Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) definition of none/mild, moderate, severe, and acute-severe. We constructed a predictive model using multivariable logistic regression and performed a competing risks analysis for survival stratified by RHF severity. RESULTS: Of 202 subjects, 52 (25.7%) developed moderate or worse RHF. Cardiopulmonary bypass (CPB) time and nadir hematocrit contributed jointly to the model of RHF severity (moderate or worse vs. none/mild; area under the curve =0.77). Postoperative length of stay (LOS) was shortest in the non/mild group and longest in the acute-severe group (median 13 vs. 29.5 days; P<0.001). Stage 2/3 acute kidney injury (range, 26-57%, P=0.002), respiratory failure (13-94%, P<0.001), stroke (0-32%, P=0.02), and 1-year mortality (19-64%, P=0.002) differed by severity. Those with acute-severe RHF had 5.4 [95% confidence interval (CI), 2.5-11.8] times the risk of 1-year mortality compared to those who did not have RHF. CONCLUSIONS: RHF remains a postoperative threat and is associated with worsened surgical outcomes. Ongoing research will reveal further opportunities to mitigate RHF post-LVAD.

13.
Proc (Bayl Univ Med Cent) ; 32(2): 177-180, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31191122

RESUMO

Age has traditionally been a limiting factor for advanced heart failure (HF) therapies. Orthotopic heart transplantation (OHT) age guidelines have become less restrictive, and left ventricular assist devices (LVADs) are increasingly utilized as destination therapy for patients ≥65 years. Although indications differ, we assessed outcomes for both modalities in this older population. We reviewed charts of consecutive advanced HF therapy recipients aged ≥65 years at our center from 2012 to 2016. Of 118 patients evaluated, 46 (39%) received an LVAD and 72 (61%) received OHT. Gender, body mass index, and rate of prior sternotomy were similar between groups; OHT recipients were younger, less likely to have diabetes mellitus, and more likely to have HF due to ischemic etiology. Forty-six percent of patients receiving LVADs were urgent need (Interagency Registry for Mechanically Assisted Circulatory Support [INTERMACS] profile 1-2), compared to 29% of patients receiving OHT (United Network for Organ Sharing 1A criteria; P = 0.068). OHT recipients had shorter lengths of stay and better 1-year survival compared to LVAD recipients. Although many centers do not offer advanced HF therapy to patients aged ≥65 years, our results indicate that age alone should not be prohibitive for advanced HF therapy, particularly OHT.

14.
Cardiorenal Med ; 9(2): 100-107, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30673661

RESUMO

BACKGROUND: Although acute kidney injury (AKI) is a common complication following cardiac surgery, less is known about the occurrence and consequences of moderate/severe AKI following left ventricular assist device (LVAD) implantation. METHODS: All patients who had an LVAD implanted at our center from 2008 to 2016 were reviewed to determine the incidence of, and risk factors for, moderate/severe (stage 2/3) AKI and to compare postoperative complications and mortality rates between those with and those without moderate/severe AKI. RESULTS: Of 246 patients, 68 (28%) developed moderate/severe AKI. A multivariable logistic regression comprising body mass index and prior sternotomy had fair predictive ability (area under the curve = 0.71). A 1-unit increase in body mass index increased the risk of moderate/severe AKI by 7% (odds ratio = 1.07; 95% confidence interval: 1.03-1.11); a prior sternotomy increased the risk more than 3-fold (odds ratio = 3.4; 95% confidence interval: 1.84-6.43). The group of patients with moderate/severe AKI had higher rates of respiratory failure and death than the group of patients with mild/no AKI. Patients with moderate/severe AKI were at 3.2 (95% confidence interval: 1.2-8.2) times the risk of 30-day mortality compared to those without. Even after adjusting for age and Interagency Registry for Mechanically Assisted Circulatory Support profile, those with moderate/severe AKI had 1.75 (95% confidence interval: 1.03-3.0) times the risk of 1-year mortality compared to those without. DISCUSSION: Risk-stratifying patients prior to LVAD placement in regard to AKI development may be a step toward improving surgical outcomes.


Assuntos
Injúria Renal Aguda/etiologia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/epidemiologia , Idoso , Feminino , Seguimentos , Taxa de Filtração Glomerular/fisiologia , Insuficiência Cardíaca/fisiopatologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Índice de Gravidade de Doença , Taxa de Sobrevida/tendências , Estados Unidos/epidemiologia , Função Ventricular Direita/fisiologia
15.
Int J Cardiol ; 274: 245-247, 2019 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-30193794

RESUMO

BACKGROUND: Targeted treatment for decompensated right heart failure (RHF) with or without left heart failure is lacking. Vasopressin antagonists (vaptans) may offer an option by increasing urine output and fluid mobilization when used in acute decompensated RHF without impacting blood pressure or renal function, both common complications of loop diuretics. METHODS AND RESULTS: We searched electronic medical records from 2 institutions over 4 years for patients with RHF treated with vaptans. Urine output, creatinine, BUN and sodium, 1 day pre- versus 1 day post-vaptan initiation were compared. Baseline (admission) pre-vaptan values for patients with RHF who met inclusion criteria (n = 112) were RAP, median (interquartile range) = 19 (13-24) mmHg; cardiac index, mean ±â€¯standard deviation = 1.8 ±â€¯0.4 L/min/m2; BNP, 1078 (523-1690) pg/ml; creatinine clearance of 51 (39-69) ml/min, BUN, 37 (26-54) mg/dl, and serum [Na+] 132 (126-135) mEq/L. Most patients (n = 103/112) received intravenous inotrope (prior to vaptan, n = 91). Overall length of stay was 27 (16-43) days. Vaptan treatment (90% tolvaptan, 10% conivaptan) was associated with increased 24 h urine output, 1517 (906-2394) vs 2337 (1425-3744) mL, p = 0.005, and [Na+], 127 (124-130) vs 130 (126-135) mEq/L, p = 0.001, without significant change in Cr or BUN. Furosemide IV dose equivalent decreased or remained unchanged in 75% of patients at 24 h and 64% at 72 h compared to the 24 h prior to vaptan use. CONCLUSION: Vaptans were associated with a significant increase in urine output and serum sodium with an apparent reduction or stabilization of furosemide equivalent dosing in the early treatment period in patients with decompensated RHF. Vaptans may offer a management option for patients failing conventional diuretic-based treatment.


Assuntos
Antagonistas dos Receptores de Hormônios Antidiuréticos/uso terapêutico , Insuficiência Cardíaca/tratamento farmacológico , Volume Sistólico/fisiologia , Função Ventricular Direita/fisiologia , Benzazepinas/uso terapêutico , Creatinina/sangue , Diurese/efeitos dos fármacos , Feminino , Seguimentos , Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Volume Sistólico/efeitos dos fármacos , Tolvaptan/uso terapêutico , Resultado do Tratamento , Função Ventricular Direita/efeitos dos fármacos
16.
Artif Organs ; 43(3): 234-241, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30357882

RESUMO

Left ventricular assist devices (LVADs) have improved clinical outcomes and quality of life for those with end-stage heart failure. However, the costs and risks associated with these devices necessitate appropriate patient selection. LVAD candidates are becoming increasingly more obese and there are conflicting reports regarding obesity's effect on outcomes. Hence, we sought to evaluate the impact of extreme obesity on clinical outcomes after LVAD placement. Consecutive LVAD implantation patients at our center from June 2008 to May 2016 were studied retrospectively. We compared patients with a body mass index (BMI) ≥40 kg/m2 (extremely obese) to those with BMI < 40 kg/m2 with respect to patient characteristics and surgical outcomes, including survival. 252 patients were included in this analysis, 30 (11.9%) of whom met the definition of extreme obesity. We found that patients with extreme obesity were significantly younger (47[33, 57] vs. 60[52, 67] years, P < 0.001) with fewer prior sternotomies (16.7% vs. 36.0%, P = 0.04). They had higher rates of pump thrombosis (30% vs. 9.0%, P = 0.003) and stage 2/3 acute kidney injury (46.7% vs. 27.0%, P = 0.003), but there were no differences in 30-day or 1-year survival, even after adjusting for age and clinical factors. Extreme obesity does not appear to place LVAD implantation patients at a higher risk for mortality compared to those who are not extremely obese; however, extreme obesity was associated with an increased risk of pump thrombosis, suggesting that these patients may require additional care to reduce the need for urgent device exchange.


Assuntos
Insuficiência Cardíaca/cirurgia , Coração Auxiliar , Obesidade Mórbida/complicações , Complicações Pós-Operatórias/epidemiologia , Implantação de Prótese/efeitos adversos , Adulto , Idoso , Índice de Massa Corporal , Feminino , Ventrículos do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Implantação de Prótese/métodos , Qualidade de Vida , Estudos Retrospectivos , Resultado do Tratamento
17.
ESC Heart Fail ; 6(1): 138-145, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30350926

RESUMO

AIMS: The time course of changes in pulmonary artery (PA) pressure due to left ventricular assist devices (LVADs) is not well understood. Here, we describe longitudinal haemodynamic trends during the peri-LVAD implantation period in patients previously implanted with a remote monitoring PA pressure sensor. METHODS AND RESULTS: We retrospectively studied PA pressure trends in patients implanted with CardioMEMS™ PA pressure sensor between October 2007 and March 2017 who subsequently had an LVAD procedure. Data are presented as mean ± standard deviation, and P-values are calculated using standard t-test with equal variance. Among 436 patients in cohort, 108 (age 58 ± 11 years, 82% male) received an LVAD and 328 (age 60 ± 13 years, 70% male) did not. The mean PA pressure at sensor implant was higher by 29% (P < 0.001) among patients who later received LVAD. Mean PA pressure 6 months prior to LVAD implant was 35.5 ± 8.5 mmHg, increasing to 39.4 ± 9.9 mmHg (P = 0.04) at 4 weeks before LVAD, and then decreasing 27% to 28.8 ± 8.4 mmHg (P < 0.001) at 3 months post-implant and stabilizing at 31.0 ± 9.4 mmHg at 1 year. CONCLUSIONS: Patients who later receive LVADs have higher PA pressures at sensor implant and show a further increase leading up to LVAD implantation. There is a significant reduction of PA pressures post-LVAD implantation that persists long term. PA pressure monitoring may aid in the clinical decision making of timing for LVAD implantation and in management of LVAD patients.


Assuntos
Insuficiência Cardíaca/fisiopatologia , Coração Auxiliar , Monitorização Hemodinâmica/métodos , Artéria Pulmonar/fisiopatologia , Pressão Propulsora Pulmonar/fisiologia , Telemedicina/métodos , Idoso , Feminino , Seguimentos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/cirurgia , Ventrículos do Coração , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
18.
Am J Cardiol ; 122(11): 1902-1908, 2018 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-30442225

RESUMO

Vasoplegia following cardiac transplantation is associated with increased morbidity and mortality. Previous studies have not accounted for primary graft dysfunction (PGD). The definition of vasoplegia is based on pressor requirement at 48 hours, many PGD parameters may have normalized after the initial 24 hours on inotropes. We surmised that the purported negative effects of vasoplegia following transplantation may in part be driven by PGD. We reviewed 240 consecutive adult cardiac transplants at our center between 2012 and 2016. The severity of vasoplegia was evaluated as a risk factor for 1-year survival, and the analysis was repeated for the subgroup of 177 patients who did not develop PGD. Overall, 63 (26%) of patients developed mild, moderate, or severe PGD. In those without PGD, vasoplegia was associated with length of stay but not with short- or long-term mortality. Moderate and/or severe vasoplegia occurred in 35 (15%) patients and was associated with higher short-term mortality, length of stay, and PGD. Multivariate logistic regression identified body mass index ≥35 kg/m2, left ventricular assist device before transplantation, and use of extracorporeal membrane oxygenation as joint risk factors for vasoplegia. In patients without PGD, only left ventricular assist device before transplantation was associated with vasoplegia. In conclusion, our results show that, in the sizeable subgroup of patients with no signs of PGD, vasoplegia had a much more modest impact on post-transplant morbidity and no significant effect on 1- and 3-year survival. This suggests that PGD may be a confounder when assessing vasoplegia as a risk factor for adverse outcomes.


Assuntos
Transplante de Coração/efeitos adversos , Complicações Pós-Operatórias/etiologia , Vasoplegia/etiologia , Idoso , Feminino , Seguimentos , Transplante de Coração/mortalidade , Mortalidade Hospitalar/tendências , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Disfunção Primária do Enxerto , Prognóstico , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida/tendências , Texas/epidemiologia , Vasoplegia/mortalidade
19.
J Am Heart Assoc ; 7(11)2018 05 17.
Artigo em Inglês | MEDLINE | ID: mdl-29773577

RESUMO

BACKGROUND: Vasoplegia is associated with adverse outcomes following cardiac surgery; however, its impact following left ventricular assist device implantation is largely unexplored. METHODS AND RESULTS: In 252 consecutive patients receiving a left ventricular assist device, vasoplegia was defined as the occurrence of normal cardiac function and index but with the need for intravenous vasopressors within 48 hours following surgery for >24 hours to maintain a mean arterial pressure >70 mm Hg. We further categorized vasoplegia as none; mild, requiring 1 vasopressor (vasopressin, norepinephrine, or high-dose epinephrine [>5 µg/min]); or moderate to severe, requiring ≥2 vasopressors. Predictors of vasoplegia severity were determined using a cumulative logit (ordinal logistic regression) model, and 1-year mortality was evaluated using competing-risks survival analysis. In total, 67 (26.6%) patients developed mild vasoplegia and 57 (22.6%) developed moderate to severe vasoplegia. The multivariable model for vasoplegia severity utilized preoperative Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) profile, central venous pressure, systolic blood pressure, and intraoperative cardiopulmonary bypass time, which yielded an area under the curve of 0.76. Although no significant differences were noted in stroke or pump thrombosis rates (P=0.87 and P=0.66, respectively), respiratory failure and major bleeding increased with vasoplegia severity (P<0.01). Those with moderate to severe vasoplegia had a significantly higher risk of mortality than those without vasoplegia (adjusted hazard ratio: 2.12; 95% confidence interval, 1.08-4.18; P=0.03). CONCLUSIONS: Vasoplegia is predictive of unfavorable outcomes, including mortality. Risk factors for future research include preoperative INTERMACS profile, central venous pressure, systolic blood pressure, and intraoperative cardiopulmonary bypass time.


Assuntos
Pressão Arterial , Insuficiência Cardíaca/terapia , Coração Auxiliar , Implantação de Prótese/efeitos adversos , Implantação de Prótese/instrumentação , Vasoplegia/etiologia , Função Ventricular Esquerda , Idoso , Pressão Arterial/efeitos dos fármacos , Ponte Cardiopulmonar , Pressão Venosa Central , Feminino , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Implantação de Prótese/mortalidade , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Vasoconstritores/uso terapêutico , Vasoplegia/tratamento farmacológico , Vasoplegia/mortalidade , Vasoplegia/fisiopatologia
20.
J Heart Lung Transplant ; 37(7): 826-835, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29699850

RESUMO

BACKGROUND: Concern over the hazards associated with undersized donor hearts has impeded the utilization of otherwise viable allografts for transplantation. Previous studies have indicated predicted heart mass (PHM) may provide better size matching in cardiac transplantation than total body weight (TBW). We investigated whether size-matching donor hearts by PHM is a better predictor of primary graft dysfunction (PGD) than matching by TBW. METHODS: Records of consecutive adult cardiac transplants performed between 2012 and 2016 at a single-center academic hospital were reviewed. We compared patients implanted with hearts undersized by ≥30% with those implanted with donor hearts matched for size (within 30%), and performed the analysis both for undersizing by PHM and for undersizing by TBW. The primary outcome was moderate/severe PGD within 24 hours, according to the 2014 International Society for Heart and Lung Transplantation consensus. Secondary outcome was 1-year survival. RESULTS: Of 253 patients, 21 (8%) and 30 (12%) received hearts undersized by TBW and PHM, respectively. The overall rate of moderate/severe PGD was 13% (33 patients). PGD was associated with undersizing if performed by PHM (p = 0.007), but not if performed by TBW (p = 0.49). One-year survival was not different between groups (log-rank, p > 0.8). Multivariate analysis confirmed that undersizing donor hearts by PHM, but not by TBW, was predictive of moderate/severe PGD (OR 3.3, 95% CI 1.3 to 8.6). CONCLUSIONS: Undersized donor hearts by ≥30% by PHM may increase rates of PGD after transplantation, confirming that PHM provides more clinically appropriate size matching than TBW. Better size matching may ultimately allow for expanding the donor pool.


Assuntos
Peso Corporal , Transplante de Coração , Coração/anatomia & histologia , Disfunção Primária do Enxerto/epidemiologia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Valor Preditivo dos Testes , Estudos Retrospectivos , Doadores de Tecidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...