Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Orthop Surg ; 11(6): 1173-1179, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31823497

RESUMO

OBJECTIVE: To evaluate clinical and radiological outcomes of proximal femoral nail anti-rotation (PFNA-II) devices and demonstrate the effectiveness of PFNA-II for the treatment of basicervical fractures in elderly patients. METHODS: A retrospective review of all patients treated with PFNA-II for a proximal femoral fracture between January 2013 and February 2017 at three different institutions (Shanghai General Hospital, Shanghai Punan Hospital and Shanghai Seventh People's Hospital) was conducted. The X-ray films were strictly reviewed by three trauma surgeons and a professional radiology doctor. Patients over 60 years of age who met the following criteria were included: (i) sustained low-energy trauma; (ii) a two-part fracture; (iii) fracture line located at the base of the femoral neck and that was medial to the intertrochanteric line and exited above the lesser trochanter but was more lateral than a classic transcervical fracture. Follow-up time should be longer than 6 months. A total of 52 patients who met the inclusion criteria were selected. The average age at diagnosis was 75.1 years (range, 63-91 years); 13 patients were men and 39 were women. The same proximal femoral nail anti-rotation devices and the same surgical procedures were applied to all patients. Postoperative radiographic union time and modified Harris hip scores were used as major indicators for evaluating the effectiveness of surgery. RESULTS: The average follow-up period was 22.5 months (18.5, 23.9, and 21.2 months, respectively) and radiographic unions were observed at an average of 19.6 weeks (range, 12-28 weeks). The patients were evaluated immediately after surgery, as well as 6 weeks, 3 months, 6 months, 1 year, and 2 years postoperatively. Of the 49 patients, 38 had good reduction qualities (75.5%), 9 acceptable (18.3%), and 3 poor (6.1%). Radiographic union was confirmed in all fractures at an average of 19.6 weeks (range, 12-28 weeks). The mean Harris hip score was 84.9 (range, 65-99): excellent in 9 patients (18.36%), good in 30 (61.22%), medium in 8 (16.32%), and poor in 2 (4.08%). Slight persistent pain occurred in 3 patients, but these patients could still walk with the help of a cane. Two patients had symptoms of excessive telescoping. Eight patients experienced postoperative medical complications, mainly pneumonia and urinary tract infection. CONCLUSION: Based on the clinical and radiological outcomes, the PFNA-II devices provide strong rotational stability and excellent clinical prognosis, and are an appropriate treatment option for basicervical proximal femoral fracture in elderly patients.


Assuntos
Fraturas do Fêmur/cirurgia , Fraturas do Colo Femoral/cirurgia , Fixação Intramedular de Fraturas/métodos , Idoso , Idoso de 80 Anos ou mais , Pinos Ortopédicos , Avaliação da Deficiência , Feminino , Fixação Intramedular de Fraturas/instrumentação , Humanos , Fixadores Internos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Rotação
2.
Zhong Yao Cai ; 37(9): 1604-8, 2014 Sep.
Artigo em Chinês | MEDLINE | ID: mdl-25857162

RESUMO

OBJECTIVE: To establish a fingerprint of seeds of Schisandra chinensis (SSC) and develop a method of quantitative analysis of multi-components by single marker (QAMS) for simultaneous determining six lignanoids in SSC. METHODS: Eleven batches of SSC were determined by HPLC and a common mode of fingerprint has been established. A method was developed for QAMS to determine schizandrol A, schizandrol B, schisantherin A, deoxyschizandrin, schizandrin B and schizandrin C in SSC. Schizandrol A was selected as internal reference; the relative correction factors (RCF)of other five lignanoids to the internal reference were calculated. The contents of the six lignanoids in eleven batches of SSC were determined by both external standard method and QAMS. The QAMS method was evaluated by comparison of its assay results with that of external standard method. RESULTS: There were 24 common peaks in fingerprints of eleven batches of SSC, six of them were identified. The similarities of fingerprints of eleven batches of SSC were over 0.980. The established RCF had a good reproducibility. No significant differences were found between the quantitative results of external standard method and QAMS. CONCLUSION: The developed method is accurate,feasible, and can be used for the qualitative and quantitative analysis of lignanoids in SSC.


Assuntos
Schisandra , Cromatografia Líquida de Alta Pressão , Ciclo-Octanos , Dioxóis , Lignanas , Compostos Policíclicos , Reprodutibilidade dos Testes , Sementes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA