Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Acta Chir Belg ; 119(3): 152-161, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29911494

RESUMO

INTRODUCTION: Any surgical procedure develops a stress situation for the patient, which can modulate the individual outcome. At present, there is only limited information about stress response in colorectal resections by laparoscopic compared to conventional surgery. Therefore, our objectives were the feasibility and the investigation of stress biomarkers including copeptin and steroid hormones before, during and after colorectal surgery. METHODS: Eleven patients underwent minimally invasive and ten patients conventionally open colorectal surgery. Blood samples were collected before, during and 24 h after surgery and copeptin, NT-proBNP, cortisol, cortisone, interleukin-6 and glucose were analyzed. RESULTS: Both, minimally invasive and conventional-open colorectal surgery caused a fast but heterogeneous response of stress biomarkers. However, the postoperative decrease of cortisol, cortisone and glucose differed between both groups. The stress biomarkers decreased faster down to baseline after minimally invasive surgery, while in open surgery cortisol, cortisone and glucose did not return to baseline within 24 h after operation. CONCLUSIONS: We show in this feasibility study for the first time an increase of copeptin in combination with glucocorticoids as stress biomarkers by open surgery compared to minimally invasive procedures in patients undergoing colorectal surgery. Exceeding an individual threshold of 'stress burden' may have unfavorable effects on the long-time clinical outcome.


Assuntos
Biomarcadores/sangue , Doenças do Colo/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos , Doenças Retais/cirurgia , Estresse Fisiológico/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Glicemia/metabolismo , Pressão Sanguínea , Doenças do Colo/sangue , Cortisona/sangue , Estudos de Viabilidade , Feminino , Glicopeptídeos/sangue , Humanos , Hidrocortisona/sangue , Interleucina-6/sangue , Masculino , Pessoa de Meia-Idade , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Doenças Retais/sangue
2.
Clin Chem Lab Med ; 55(6): 826-835, 2017 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-27898397

RESUMO

BACKGROUND: Untreated disorders of the adrenocortical system, such as Cushing's or Addison's disease, can be fatal, and accurate quantification of a patient's cortisol levels is vital for diagnosis. The objective of this study was to assess the analytical performance of a new fully-automated Elecsys® Cortisol II assay (second generation) to measure cortisol levels in serum and saliva. METHODS: Four European investigational sites assessed the intermediate precision and reproducibility of the Cortisol II assay (Roche Diagnostics) under routine conditions. Method comparisons of the Cortisol II assay vs. liquid chromatography-tandem mass spectrometry (LC-MS/MS), the gold standard for cortisol measurement, were performed. Cortisol reference ranges from three US sites were determined using samples from self-reported healthy individuals. RESULTS: The coefficients of variation (CVs) for repeatability, intermediate precision, and reproducibility for serum samples were ≤2.6%, ≤5.8%, and ≤9.5%, respectively, and for saliva were ≤4.4% and ≤10.9%, and ≤11.4%, respectively. Agreement between the Cortisol II assay and LC-MS/MS in serum samples was close, with a slope of 1.02 and an intercept of 4.473 nmol/L. Reference range samples were collected from healthy individuals (n=300) and serum morning cortisol concentrations (5-95th percentile) were 166.1-507 nmol/L and afternoon concentrations were 73.8-291 nmol/L. Morning, afternoon, and midnight saliva concentrations (95th percentile) were 20.3, 6.94, and 7.56 nmol/L, respectively. CONCLUSIONS: The Cortisol II assay had good precision over the entire measuring range and had excellent agreement with LC-MS/MS. This test was found suitable for routine diagnostic application and will be valuable for the diagnosis of adrenocortical diseases.


Assuntos
Análise Química do Sangue/métodos , Hidrocortisona/análise , Análise Química do Sangue/normas , Reações Cruzadas , Humanos , Hidrocortisona/sangue , Hidrocortisona/imunologia , Limite de Detecção , Valores de Referência , Saliva/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...