Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Radiat Prot Dosimetry ; 120(1-4): 176-83, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16702247

RESUMO

The objective of the Third International Intercomparison on EPR Tooth Dosimetry was to evaluate laboratories performing tooth enamel dosimetry <300 mGy. Final analysis of results included a correlation analysis between features of laboratory dose reconstruction protocols and dosimetry performance. Applicability of electron paramagnetic resonance (EPR) tooth dosimetry at low dose was shown at two applied dose levels of 79 and 176 mGy. Most (9 of 12) laboratories reported the dose to be within 50 mGy of the delivered dose of 79 mGy, and 10 of 12 laboratories reported the dose to be within 100 mGy of the delivered dose of 176 mGy. At the high-dose tested (704 mGy) agreement within 25% of the delivered dose was found in 10 laboratories. Features of EPR dose reconstruction protocols that affect dosimetry performance were found to be magnetic field modulation amplitude in EPR spectrum recording, EPR signal model in spectrum deconvolution and duration of latency period for tooth enamel samples after preparation.


Assuntos
Espectroscopia de Ressonância de Spin Eletrônica/métodos , Odontologia Legal/métodos , Radioisótopos/análise , Radiometria/métodos , Dente/química , Espectroscopia de Ressonância de Spin Eletrônica/tendências , Odontologia Legal/tendências , Humanos , Radiometria/tendências , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Appl Radiat Isot ; 62(2): 163-71, 2005 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15607443

RESUMO

The objective of the 3rd International Intercomparison on Electron Paramagnetic Resonance (EPR) Tooth Dosimetry was the evaluation of laboratories performing tooth enamel dosimetry below 300 mGy. Participants had to reconstruct the absorbed dose in tooth enamel from 11 molars, which were cut into two halves. One half of each tooth was irradiated in a 60Co beam to doses in the ranges of 30-100 mGy (5 samples), 100-300 mGy (5 samples), and 300-900 mGy (1 sample). Fourteen international laboratories participated in this intercomparison programme. A first analysis of the results and an overview of the essential features of methods applied in different laboratories are presented. The relative standard deviation of results of all methods was better than 27% for applied doses in the range of 79-704 mGy. In the analysis of the unirradiated tooth halves 8% of the samples were identified as outliers with additional absorbed dose above background dose.


Assuntos
Espectroscopia de Ressonância de Spin Eletrônica/métodos , Espectroscopia de Ressonância de Spin Eletrônica/normas , Radiometria/métodos , Radiometria/normas , Padrões de Referência , Dente/química , Dente/efeitos da radiação , Benchmarking/métodos , Carga Corporal (Radioterapia) , Humanos , Técnicas In Vitro , Internacionalidade , Garantia da Qualidade dos Cuidados de Saúde/métodos , Garantia da Qualidade dos Cuidados de Saúde/normas , Doses de Radiação , Eficiência Biológica Relativa , Reprodutibilidade dos Testes , Estudos Retrospectivos , Medição de Risco/métodos , Medição de Risco/normas , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...