Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMC Oral Health ; 24(1): 462, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627762

RESUMO

BACKGROUND: This cross-sectional study aimed to identify factors associated with age-related changes in masticatory performance (MP) and oral diadochokinesis (ODK) and to provide normal values in healthy old adults for the diagnosis of oral frailty. METHODS: A total of 385 participants were divided into three age groups (Gr1-3): 20-64 years, 65-74 years, and ≥ 75 years. To investigate tongue-lip motor function, ODK was assessed as the number of repetitions of the monosyllables /pa/ta/ka/. Four questionnaires were used to assess subjective masticatory ability, cognitive ability, and psychological status. MP, bite force, and occlusal area were tested to assess dynamic objective masticatory function, and the number of remaining teeth and functional tooth pairs were determined to assess static objective masticatory function. Handgrip strength (HG), oral dryness, and tongue pressure (TP) were assessed to identify influencing factors. Intergroup differences were evaluated by ANOVA and the Kruskal‒Wallis test, and correlations between ODK and orofacial factors were evaluated. RESULTS: This study revealed significant age-related declines in TP, HG, and ODK, especially after 65 years of age. Factors affecting MP were posterior teeth, the Eichner index, bite force, occluding area, the Korean Mini-Mental State Examination (KMMSE) score, and ODK. Each ODK syllable was associated with different factors, but common factors associated with ODK were MP, HG, and PHQ-9 score. For the syllables /pa/ta/, the Eichner Index, TP, and oral dryness were also associated. For the syllable /ka/ in Gr3, MP, TP, HG, oral dryness, and the KMMSE score were associated. CONCLUSIONS: These results could provide practical guidelines for oral rehabilitation in old adults and contribute to improving the understanding of age-related changes in oral function and the multidimensional nature of masticatory dynamics.


Assuntos
Língua , Xerostomia , Adulto , Humanos , Idoso , Força da Mão , Estudos Transversais , Pressão , Mastigação
2.
J Mech Behav Biomed Mater ; 148: 106167, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37837875

RESUMO

This study aimed to assess the effect of low-temperature degradation (LTD) and surface treatment on the flexural strength of additive-manufactured (AM) zirconia by comparison to subtractive-manufactured (SM) zirconia. Disc-shaped zirconia specimens were fabricated using AM and SM technology, and each group was assigned to 3 subgroups according to the type of surface treatment: control, sandblasting (SB), and 9% hydrofluoric acid etching (HF). The groups were then further divided into 2 subgroups: unaged and aged. Biaxial flexural strength, crystal phase, surface topography, and surface roughness were measured to evaluate the mechanical properties. Statistical analyses were performed with 3-way ANOVA, followed by the comparison of means with Bonferroni post hoc analyses. The means and standard deviations of the biaxial flexural strength and Weibull parameters were calculated with descriptive statistics. All SM groups showed significantly greater flexural strength than the AM groups (p < .05), and LTD did not affect flexural strength except for the SMHF group (p < .05). After LTD, monoclinic phases (m-phase) were found in all groups, and SEM images showed grain pullout due to zirconia volume expansion in both control groups. Sandblasting significantly affected flexural strength (p < .05), whereas the HF group did not affect flexural strength except in the SMHF group after LTD (p < .05). No significant difference was observed in the surface roughness of AM compared to SM groups conditioned with the same surface treatment regardless of LTD. AM zirconia has comparable mechanical properties to SM zirconia, regardless of low-temperature degradation and surface treatment, which indicates the potential of the AM technique for clinical applications.


Assuntos
Resistência à Flexão , Zircônio , Teste de Materiais , Temperatura , Propriedades de Superfície , Zircônio/química , Cerâmica , Ítrio/química , Materiais Dentários
3.
Sci Rep ; 13(1): 9153, 2023 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-37280320

RESUMO

This study aimed to evaluate the mechanical properties of zirconia fabricated using additive manufacturing technology and compare them to those of zirconia fabricated using subtractive manufacturing technology. Sixty disc-shaped specimens were fabricated for the additive (n = 30) and subtractive manufacturing groups (n = 30), and each group was divided into two subgroups according to their air-abrasion surface treatment: control (n = 15) and air-abrasion groups (n = 15). Mechanical properties including the flexural strength (FS), Vickers hardness, and surface roughness were determined, and the values were analyzed by one-way ANOVA and Tukey's post hoc test (α = 0.05). X-ray diffraction and scanning electron microscopy were used for phase analysis and surface topography evaluation, respectively. The SMA group exhibited the highest FS (1144.97 ± 168.1 MPa), followed by the SMC (944.58 ± 141.38 MPa), AMA (905.02 ± 111.38 MPa), and AMC groups (763.55 ± 68.69 MPa). The Weibull distribution showed the highest scale value (1213.55 MPa) in the SMA group, with the highest shape value in the AMA group (11.69). A monoclinic peak was not detected in both the AMC and SMC groups, but after air abrasion, the monoclinic phase content ([Formula: see text]) reached 9% in the AMA group, exceeding that in the SMA group (7%). The AM groups exhibited statistically lower FS values than those of the SM groups under the same surface treatment (p < 0.05). Air-abrasion surface treatment increased the monoclinic phase content and FS (p < 0.05) in both the additive and subtractive groups, while it increased the surface roughness (p < 0.05) only in the additive group and did not affect the Vickers hardness in either group. For zirconia manufactured using additive technology, the mechanical properties are comparable to those of zirconia manufactured using subtractive technology.

4.
Heliyon ; 9(4): e15314, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37095924

RESUMO

Statement of problem: Biomaterials, including polymethyl methacrylate (PMMA) and bisacrylate, have been widely used as conventional interim materials and may exhibit cytotoxicity or systemic toxicity. Purpose: This study was designed to compare the mechanical properties of polylactic acid (PLA) as an alternative to conventional dental polymers for computer-aided design and manufacturing (CAD/CAM). Material and methods: Four groups (n = 20 per group) of CAD/CAM polymers were assessed. Specimens of PLA (PLA Mill) and PMMA (PMMA Mill) for subtractive manufacturing, PLA for fused deposition modeling (PLA FDM), and bisphenol for additive manufacturing by stereolithography (Bisphenol SLA) were fabricated into 2-mm-wide, 2-mm-thick and 25-mm-long specimens using a milling machine, an FDM printer, and an SLA printer, respectively.The flexural strength (FS) and elastic modulus (EM) were calculated. The surface roughness and Shore D hardness were analyzed with a 3D optical surface roughness analyzer and a Shore durometer, respectively. Results: PLA Mill showed the lowest FS (64.9 ± 8.28), followed by PLA FDM (104.27 ± 4.42 MPa), PMMA Mill (139.2 ± 20.95 MPa), and Bisphenol SLA (171.56 ± 15.38 MPa), with statistically significant differences. PLA FDM showed the highest EM, followed by PLA Mill, Bisphenol SLA, and PMMA Mill. Significant differences were observed not only between PMMA Mill and Bisphenol SLA but also between PLA FDM and PLA Mill. The lowest Shore D hardness was observed for PLA FDM, followed by PLA Mill, PMMA Mill, and Bisphenol SLA, which showed the highest value among the 4 groups, with significance. The highest values for the surface roughness parameters were observed for PLA Mill, and the lowest were observed for Bisphenol SLA. Conclusions: Among the tested CAD/CAM polymers, Bisphenol SLA was the most durable material, and the mechanical properties of PLA FDM were within the clinically acceptable range.

5.
Aging Clin Exp Res ; 35(1): 107-115, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36367631

RESUMO

BACKGROUND: Masticatory function is known to be related to cognitive ability; therefore, factors for improving masticatory function should be identified. AIMS: This study aimed to identify factors influencing masticatory function associated with mild cognitive impairment (MCI) in elderly individuals. METHODS: A total of 123 elderly participants [mean age: 76.5 ± 6.5 years; 82 females (66.7%), 41 males (33.3%)] were included. Cognitive function was evaluated by the Korean version of the Mini-Mental State Examination (KMMSE). Questionnaires for subjective evaluation were administered, and dynamic objective masticatory function evaluations, including chewing tests and bite force measurements, were performed. Intergroup differences were evaluated by the Wilcoxon rank-sum and chi-square test, and correlations between cognitive ability and masticatory function were evaluated by multilinear logistic regression. RESULTS: The number of teeth, number of posterior teeth, bite force, masticatory ability index (MAI) and posterior support status showed significant differences between the normal (KMMSE > 23) and MCI (KMMSE ≤ 23) groups. However, only the MAI, representing dynamic masticatory performance, was significantly associated with MCI regardless of age, sex and removable prostheses. The number of teeth and posterior teeth, bite force, subjective masticatory ability and posterior occlusal support showed no significant association with MCI. DISCUSSION: These results suggested the importance of chewing function for preventing the progression of cognitive impairment. CONCLUSIONS: Considering that only the MAI was significantly associated with MCI, it is more important to improve chewing efficiency by harmonizing therapeutic prosthetics with the surrounding masticatory system than simply increasing the number of teeth to prevent or delay cognitive impairment in elderly individuals.


Assuntos
Disfunção Cognitiva , Mastigação , Masculino , Feminino , Humanos , Idoso , Idoso de 80 Anos ou mais , Inquéritos e Questionários , Força de Mordida , Cognição
6.
J Prosthet Dent ; 130(4): 419-433, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36109259

RESUMO

Metal frameworks have been used for implant-supported complete arch fixed dental prostheses (ISCFDPs) for maxillary or mandibular edentulous arches with a crown height space of more than 15 mm. However, technical difficulties in the casting, weight, and lack of passivity of the metal have led dentists and dental laboratory technicians to choose materials with different biomechanical properties, including polyetheretherketone (PEEK) and polyetherketoneketone (PEKK). This clinical report describes the design of ISCFDPs using PEKK frameworks, the number of cantilevers, the condition of the opposing dentition, and the incidence of complications, including zirconia crown or PEKK framework fracture, as well as the clinical outcomes of 5 patients observed prospectively over 8 to 65 months. No mechanical complications of PEKK-made ISCFDPs opposing removable prostheses occurred, regardless of the presence of cantilevers. The ISCFDPs that opposed natural dentition or a combination of the natural dentition and fixed prostheses showed different clinical outcomes depending on the length of cantilevers and the number and location of pontics.


Assuntos
Implantes Dentários , Boca Edêntula , Humanos , Zircônio/uso terapêutico , Coroas , Prótese Dentária Fixada por Implante , Falha de Restauração Dentária
7.
Artigo em Inglês | MEDLINE | ID: mdl-34199065

RESUMO

This study aimed to investigate the influence of changes in age-related physiological muscular and dental factors on masticatory function. This study was conducted in 211 healthy participants divided into four different age groups: 20-45 years (Gr1); 45-60 years (Gr2); 61-70 years (Gr3); and ≥71 years (Gr4). For objective evaluation of masticatory function, the masticatory performance, bite force, posterior bite area (PBA), functional tooth units (FTUs), the number of remaining teeth, tongue pressure, masseter muscle thickness (MMT), and handgrip strength were examined. Food intake ability (FIA) and the Oral Health Impact Profile-14 score were assessed subjectively using questionnaires. A significant decrease in the number of remaining teeth, FTUs, handgrip strength, and FIA was found in Gr4, and a significant decrease in the tongue pressure, PBA, and bite force was found in those aged ≥61 years. In groups 1 and 3, an association of the PBA with masticatory performance was observed. However, there was no significant decreasing trend in the MMT with respect to masticatory performance with aging. With sufficient FTUs and posterior tooth support, although age-dependent decreases in the bite force, tongue pressure and handgrip strength were observed, masticatory performance was maintained. Establishing the PBA by improving occlusion through dental treatment is thought to be important for masticatory function.


Assuntos
Dentição , Força da Mão , Adulto , Humanos , Mastigação , Pessoa de Meia-Idade , Pressão , Língua , Adulto Jovem
8.
PLoS One ; 16(4): e0249208, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33793622

RESUMO

This study aimed to analyze fracture strength in vitro by varying the axial height of the titanium insert and the labial height of the zirconia abutment in an internal connection implant to identify the titanium insert axial height with optimal mechanical stability. Sixty implants with an internal connection system were used. Two-piece zirconia abutments were used with the titanium inserts. Combinations of different titanium insert axial heights (mm) and zirconia abutment labial heights (mm) constituted five groups: Gr1 (1-3), Gr2 (3-3), Gr3 (3-5), Gr4 (5-3), and Gr5 (5-5). After thermocycling, a fracture load test was performed with a universal testing machine. The initial deformation load and the fracture load were measured and analyzed. The fractured surface and cross-section of the specimens were examined by scanning electron microscopy (SEM). The groups of titanium inserts with axial heights of 3 mm and 5 mm showed significantly greater initial deformation load and fracture load than the group with an axial height of 1 mm (p < 0.05), but there was no significant difference between the two groups with axial heights of 3 mm and 5 mm. The labial height of the zirconia abutment had no significant influence on the initial deformation load and fracture load. In some specimens in Gr4 and Gr5, cracking or bending of the titanium insert and abutment screw was observed on SEM. The axial height of the titanium insert should be designed to not be less than 3 mm to increase the fracture strength and promote the long-term stability of implants.


Assuntos
Resistência à Flexão/fisiologia , Teste de Materiais/normas , Estresse Mecânico , Titânio/uso terapêutico , Dente Suporte/normas , Falha de Restauração Dentária , Análise do Estresse Dentário/métodos , Fraturas Ósseas/prevenção & controle , Humanos , Microscopia Eletrônica de Varredura , Titânio/química , Zircônio/química , Zircônio/uso terapêutico
9.
PLoS One ; 15(10): e0240508, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33064731

RESUMO

OBJECTIVES: This study aimed to evaluate the marginal and internal gaps in 3D-printed interim crowns made from digital models of cone-beam computed tomography (CBCT) conversion data. MATERIALS AND METHODS: Sixteen polyvinylsiloxane impressions were taken from patients for single crown restorations and were scanned using CBCT. The scanning data were converted to positive Standard Triangulation Language (STL) files using custom-developed software. The fabricated stone models were scanned with an intraoral optical scanner (IOS) to compare the surface accuracy with the STL data obtained by CBCT. The converted STL files were utilized to fabricate interim crowns with a photopolymer using a digital light-processing 3D printer. The replica method was used to analyze the accuracy. The marginal and internal gaps in the replica specimen of each interim crown were measured with a digital microscope. The Friedman test and Mann-Whitney U test (Wilcoxon-signed rank test) were conducted to compare the measurements of the marginal and internal gaps with a 95% level of confidence. RESULTS: The root-mean-square values of the CBCT and IOS ranged from 41.00 to 126.60 µm, and the mean was 60.12 µm. The mean values of the marginal, internal, and total gaps were 132.96 (±139.23) µm, 137.86 (±103.09) µm, and 135.68 (±120.30) µm, respectively. There were no statistically significant differences in the marginal or internal gaps between the mesiodistal and buccolingual surfaces, but the marginal area (132.96 µm) and occlusal area (255.88 µm) had significant mean differences. CONCLUSION: The marginal gap of the fabricated interim crowns based on CBCT STL data was within the acceptable range of clinical success. Through ongoing developments of high-resolution CBCT and the digital model conversion technique, CBCT might be an alternative method to acquire digital models for interim crown fabrication.


Assuntos
Materiais para Moldagem Odontológica/química , Planejamento de Prótese Dentária/métodos , Polivinil/química , Siloxanas/química , Humanos , Modelos Anatômicos , Impressão Tridimensional , Software , Tomografia Computadorizada de Feixe Cônico Espiral/instrumentação
10.
J Oral Implantol ; 45(6): 474-482, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31536449

RESUMO

Cone-beam computerized tomography (CBCT) can show an uncommon mandibular incisive canal that cannot be detected by panoramic radiography, which is used preoperatively to form the initial plan of the size and length of an implant fixture for surgical placement in the mandibular interforaminal area. Determination of the position and anatomical configuration of the mandibular incisive canal is challenging. The purpose of this case report is to discuss anatomical variations in the mandibular incisive canal and the mental canal by reviewing previous studies. Furthermore, we propose that the anterior loop length of the mental canal near the mental foramen, as well as the diameter of the mandibular incisive canal, should be verified by CBCT prior to performing implant surgery in the anterior mandibular area to prevent possible nerve damage.


Assuntos
Implantes Dentários , Tomografia Computadorizada de Feixe Cônico , Mandíbula , Radiografia Panorâmica
11.
Materials (Basel) ; 12(10)2019 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-31096562

RESUMO

Various mechanical and chemical surface treatments have been proposed to improve the retention of fiber-reinforced composite post (FRCP), but the results are still controversial. The bond strength and durability of a self-etching ceramic primer, which was recently released as an alternative to etching and silane, are not yet known. This study aimed to compare and evaluate the push-out bond strength of different surface treatments of FRCPs after an artificial aging procedure. Four groups (n = 10) were established to evaluated FRCP surface treatments (dentin adhesive bonding; silane and adhesive bonding; hydrofluoric acid, silane and adhesive bonding; and a self-etching ceramic primer). They were bonded with dual-curing rein cement (Multilink N) and stored in distilled water at 37 °C for 30 days, then thermal cycled for 7500 cycles. After being sectioned into 1 mm thickness, each coronal and apical part was evaluated for its the push-out bond strength by a universal testing machine. Each debonded specimen was observed by an optical microscope and divided according to the failure modes. The results showed that silane treatment significantly improved push-out bond strength, but the self-etching ceramic primer did not do so. Additional hydrofluoric acid treatment or the adhesive bonding agent alone did not significantly improve the retention of FRCPs. Cohesive failure of the luting material was found most frequently in all groups.

12.
Clin Oral Investig ; 23(1): 87-98, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29525925

RESUMO

OBJECTIVES: This retrospective study aimed to investigate the clinical outcome of tooth autotransplantation and related prognostic factors. MATERIALS AND METHODS: Eighty-two cases of transplanted teeth from March 2006 to December 2016 were retrospectively investigated by medical records and radiographs. The clinical outcomes of transplanted teeth, which included tooth survival, inflammatory root resorption (IRR), ankylosis, and marginal bone loss (MBL), and the related prognostic factors were assessed via survival analysis. RESULTS: The cumulative survival rate of transplanted teeth was 74% at 10 years after autotransplantation. According to Cox proportional hazards regression analysis, the eruption state of the donor tooth, recipient position, and postoperative MBL were significantly related to tooth survival. The donor tooth position was significantly associated with IRR, the recipient position and the timing of orthodontic initiation with ankylosis, and the recipient position with MBL. CONCLUSIONS: Fully erupted donor teeth and a bounded recipient site were significantly associated with longer tooth survival. Periodontal healing and management to prevent postoperative MBL were as important for successful autotransplantation. CLINICAL RELEVANCE: Knowledge about the prognostic factors that are significantly associated with each particular clinical outcome may guide clinicians to achieve predictable and successful outcomes after tooth transplantation.


Assuntos
Dente/transplante , Adolescente , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Prognóstico , Estudos Retrospectivos , Transplante Autólogo , Resultado do Tratamento
13.
Clin Oral Implants Res ; 28(12): 1501-1508, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28391648

RESUMO

OBJECTIVES: The aim was to analyze the prevalence rate of proximal contact loss (PCL) between implant-fixed prostheses (IFPs) and adjacent teeth and investigate the associated factors. MATERIAL AND METHODS: One hundred fifty participants were recruited for this prospective study from January 2009 to December 2014. Two hundred thirty-four IFPs supported by 384 implants for the posterior region were followed up until June 2016. The contact tightness had been recorded using aluminum strips of different thicknesses with a regular interval after delivery. Proximal contact was considered as lost if the contact tightness was over 50 µm, and statistical analyses were performed to estimate the prevalence rate of PCL and its influential factors. RESULTS: Among the total 299 proximal contacts of 234 IFPs, 179 were observed as a PCL (59.9%). Bone level and root configuration of the adjacent teeth, the proximal contact position and jaw position of the implant prostheses were statistically significant factors, when analyzed by the cumulative PCL rate using the log-rank test of the Kaplan-Meier method (P < 0.05) According to the Cox proportional hazard regression analysis, the proximal contact position, bone level of adjacent teeth and jaw position were revealed to be statistically significant (P < 0.05). CONCLUSION: PCL should be considered an implant prosthesis complication to which various associated factors could be related. This study revealed that the lower alveolar bone support level of the adjacent teeth, maxillary position of IFPs and mesial site of IFPs were significantly associated with a higher incidence of PCL.


Assuntos
Prótese Dentária Fixada por Implante , Prótese Parcial Fixa , Movimento Mesial dos Dentes , Adulto , Feminino , Humanos , Arcada Parcialmente Edêntula/terapia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Adulto Jovem
14.
J Dent Anesth Pain Med ; 16(2): 81-88, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28879299

RESUMO

Local anesthesia is administered to reduce pain during dental treatments, but may itself cause pain and contribute to increased dental fear. Computer-controlled local anesthetic delivery (CCLAD) is one the method to reduce patient pain during local anesthesia; it is a device that slowly administers anesthetics by using a computerized device to control the injection speed. This literature review aims to provide an objective assessment of the usefulness of CCLAD for controlling pain by reviewing papers published to date that have used CCLAD.

15.
J Dent Anesth Pain Med ; 16(2): 147-150, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28879309

RESUMO

The prevalence of thyroid disease, particularly hyperthyroidism, has rapidly increased in Korea in the past 10 years. Therefore, it is important to consider the complete medical history including thyroid disease in patients under dental treatment. Both the drugs used for dental treatment and psychological symptoms associated with treatment can induce emergencies in hyperthyroid patients. This case report considers emergency situations during dental treatment for hyperthyroid patients, and discusses risk factors and related concerns.

16.
Photomed Laser Surg ; 33(1): 9-14, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25594768

RESUMO

OBJECTIVE: The aim of this study was to evaluate the desensitizing effects of a dentifrice containing nano-carbonate apatite (n-CAP) and Er,Cr:YSGG laser in the treatment of dentin hypersensitivity. BACKGROUND DATA: Most studies of hypersensitivity treatment have been conducted with different methods of professional treatment and self-care in each study. Moreover, clinical studies that compare self-care and professional treatment have not yet been published. METHODS: Eighty-two patients with dentin hypersensitivity were divided randomly into three groups: (1) a control group with strontium chloride dentifrice (SC), (2) n-CAP dentifrice (n-CAP), and (3) an Er,Cr:YSGG laser (laser) group. The study was conducted for 4 weeks: a treatment period of 2 weeks and a maintenance period of 2 subsequent weeks. The SC and n-CAP groups were instructed to brush their teeth twice a day for 1 min. The laser group visited twice at 1 week intervals for irradiation of the sensitive teeth. The desensitizing effect was evaluated by assessing the tactile sensitivity using the visual analogue scale (VAS), and evaporative air sensitivity was determined using an air blast score (ABS). RESULTS: The n-CAP group and the laser group showed significantly different desensitizing effects in VAS after 4 weeks (69% and 63%, respectively) and a 33% (p<0.05) and 3% (p>0.05) desensitizing effect, respectively, in VAS during the maintenance period. CONCLUSIONS: The n-CAP and the laser were effective in reducing dentin hypersensitivity. The laser had a superior desensitizing effect at the initial stage, whereas the n-CAP maintained its effect for a relatively longer time in clinical situations.


Assuntos
Apatitas/uso terapêutico , Dentifrícios/uso terapêutico , Dessensibilizantes Dentinários/uso terapêutico , Sensibilidade da Dentina/tratamento farmacológico , Sensibilidade da Dentina/radioterapia , Lasers de Estado Sólido/uso terapêutico , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Nanopartículas , Método Simples-Cego , Estrôncio/uso terapêutico , Escovação Dentária , Resultado do Tratamento
17.
J Prosthodont ; 24(6): 499-505, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25521857

RESUMO

For patients with periodontally compromised, hypermobile teeth, implant-supported fixed dental prostheses (FDPs) or removable dentures are often used after extracting mobile teeth. The loss of native teeth may carry social consequences, depending upon the patient's age, state of health, and degree of social functioning. This report represents successful stabilization and preservation of questionable, hypermobile teeth that have been damaged by traumatic occlusion due to the loss of posterior support with a cross-arch splinted FDP, as well as the implementation of posterior support using implant-supported prostheses.


Assuntos
Implantação Dentária , Implantes Dentários/estatística & dados numéricos , Arcada Parcialmente Edêntula/terapia , Placas Oclusais/estatística & dados numéricos , Mobilidade Dentária/terapia , Feminino , Seguimentos , Humanos , Pessoa de Meia-Idade
18.
J Dent Anesth Pain Med ; 15(1): 17-23, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28879254

RESUMO

BACKGROUND: Dental injury as a result of oroendotracheal intubation during general anesthesia is very common. We report our experiences of using mouthguard to prevent dental injury during intubation based on our protocol. METHODS: This retrospective study enrolled patients referred for preanesthetic evaluation, those patients with a history of any of the dental treatments to their anterior teeth listed on our fabrication protocol from January 1, 2009 to June 30, 2010. RESULTS: No cases of dental trauma during oroendotracheal intubation were reported among the 202 patients who used a protective device. 66% of the patients had risk factors for hard tissue damage aged 10-40 years. At the ages of 40-70 years, the incidence of risk group for periodontal damage was higher. CONCLUSIONS: Preanesthetic consultation was effective for preventing dental injury, so preanesthetic questionnaire and proper dental consultation would be helpful.

19.
Restor Dent Endod ; 39(3): 226-9, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25110648

RESUMO

Orthodontic extrusion is usually performed by means of a fixed orthodontic appliance that utilizes arch wire attached to adjacent teeth and transfers the desired force by elastic from the wire to the root. However, clinicians often encounter cases where the bonding required for tooth traction is not possible because the adjacent teeth have been restored with ceramic or veneer. The purpose of this case report is to describe a modified orthodontic extrusion appliance that is useful when conventional orthodontic treatment is not possible. The modified appliance was fabricated using an artificial tooth, clear plastic sheeting, and a braided fiber-reinforced composite strip that covered adjacent teeth without bonding. It satisfied the esthetic and functional needs of the patient and established the optimal biologic width.

20.
J Adv Prosthodont ; 6(3): 171-6, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25006380

RESUMO

PURPOSE: The aim of this study was to determine the absolute value of the root/crown ratio (R/C ratio) using panoramic radiographs (PRGs) in a healthy Korean population. MATERIALS AND METHODS: In total, 99 patient radiographs (of 50 males and 49 females subjects; aged 16 to 24 years old) were examined, and 2,770 teeth were analyzed. Crown lengths and root lengths were measured with modified Lind's measurements using PACS tools by two examiners in two separate sessions two months apart. All data were analyzed using SPSS. The independent t-test was used to assess for gender differences, and the paired t-test was used to compare both arches with a significance level of P<.05. RESULTS: The mean R/C ratios varied from 1.29 to 1.89 (male: 1.28-1.84; females: 1.31-1.94). The highest R/C ratios were recorded for the mandibular canines (1.89), followed by the maxillary canines (1.79). The lowest R/C ratios were recorded for the maxillary second molars (1.31). In comparison with the maxillary teeth (1.29-1.78), the mandibular teeth yielded the higher R/C ratio (1.47-1.89), and this difference was significant in the females (P<.05). The difference between the genders was not statistically significant, except for the maxillary central incisors, mandibular canines and mandibular first premolars. CONCLUSION: These data may enhance the understanding of the clinical R/C ratio as a useful guideline for determining the status of teeth and the ethnic difference.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...