Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Chemosphere ; 354: 141687, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38484990

RESUMO

Biogas obtained from livestock manure is used as fuel for solid oxide fuel cells. Although H2S is a typical biogas, it is a fatal disadvantage for fuel-cell power generation and, thus, must be removed. In this study, we proposed an effective method for sulfide removal from water using a multi-hole dielectric barrier discharge (DBD) system. In this system, active species, such as ozone, ultraviolet rays, hydroxyl radicals, and hydrogen peroxide, were simultaneously generated. Under optimal conditions, dissolved sulfide (initial concentration: 120 mg/L) was completely degraded within 10 min in air plasma and 6 min in oxygen plasma. Changes in the physical properties of the sulfide-treated water were confirmed by measuring the pH, oxidation-reduction potential, and dissolved oxygen. Results of the by-product analysis showed that sulfide was converted into sulfate by reacting with a large amount of ozone, and the active species were emitted from the multi-hole DBD system. In summary, multi-hole DBD technology has demonstrated merit as a water-contaminant purification technology and for the removal of dissolved sulfide.


Assuntos
Ozônio , Poluentes Químicos da Água , Água , Biocombustíveis , Poluentes Químicos da Água/análise , Oxigênio/análise , Ozônio/química
2.
Animals (Basel) ; 13(23)2023 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-38067045

RESUMO

Whole blood viscosity, a hemorheological factor, is currently used for diagnosis, as it is correlated with various vascular diseases that are difficult to diagnose early with a general blood test. It was determined that it was necessary to set reference intervals for further studies and utilization of whole blood viscosity in cats, a representative companion animal, and this study was conducted. Fifty healthy cats were recruited for the study, and whole blood viscosity, complete blood count, and serum chemistry tests were performed. The reference intervals of whole blood viscosity were 15.169 to 43.684 cP at a shear rate of 1 s-1 reflecting diastole, and 3.524 to 5.544 cP at a shear rate of 300 s-1 reflecting systole. Red blood cells, hematocrit, hemoglobin, white blood cells, and neutrophils in the complete blood count, and total protein, albumin, globulin, and cholesterol in the serum chemistry were significantly correlated with whole blood viscosity. The results of this study set the reference intervals of whole blood viscosity for healthy cats in a wide shear rate range that has not yet been fully established, and its correlation with other blood indicators investigated.

3.
Micromachines (Basel) ; 14(9)2023 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-37763899

RESUMO

Traditional goal of microfabrication was to limitedly construct nano- and micro-geometries on silicon or quartz wafers using various semiconductor manufacturing technologies, such as photolithography, soft lithography, etching, deposition, and so on. However, recent integration with biotechnologies has led to a wide expansion of microfabrication. In particular, many researchers studying pharmacology and pathology are very interested in producing in vitro models that mimic the actual intestine to study the effectiveness of new drug testing and interactions between organs. Various bio-microfabrication techniques have been developed while solving inherent problems when developing in vitro micromodels that mimic the real large intestine. This intensive review introduces various bio-microfabrication techniques that have been used, until recently, to realize two-dimensional and three-dimensional biomimetic experimental models. Regarding the topic of gut chips, two major review subtopics and two-dimensional and three-dimensional gut chips were employed, focusing on the membrane-based manufacturing process for two-dimensional gut chips and the scaffold-based manufacturing process for three-dimensional gut chips, respectively.

4.
Membranes (Basel) ; 12(7)2022 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-35877891

RESUMO

Polydimethylsiloxane (PDMS) membranes can allow the precise control of well-defined micropore generation. A PDMS solution was mixed with a Rushton impeller to generate a large number of microbubbles. The mixed solution was spin-coated on silicon wafer to control the membrane thickness. The microbubbles caused the generation of a large number of small and large micropores in the PDMS membranes with decreased membrane thickness. The morphology of the thinner porous PDMS membrane induced higher values of roughness, Young's modulus, contact angle, and air permeability. At day 7, the viability of cells on the porous PDMS membranes fabricated at the spin-coating speed of 5000 rpm was the highest (more than 98%) due to their internal networking structure and surface properties. These characteristics closely correlated with the increased formation of actin stress fibers and migration of keratinocyte cells, resulting in enhanced physical connection of actin stress fibers of neighboring cells throughout the discontinuous adherent junctions. The intact detachment of a cell sheet attached to a porous PDMS membrane was demonstrated. Therefore, PDMS has a great potential for enhancing the formation of cell sheets in regenerative medicine.

5.
J Biophotonics ; 15(10): e202200091, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35770625

RESUMO

In the field of biology, dark field microscopy provides superior insight into cells and subcellular structures. However, most dark field microscopes are equipped with a dark field filter and a light source on a 2D-based specimen, so only a flat sample can be observed in a limited space. We propose a compact cell monitoring system with built-in dark field filter with an optimized incident angle of the light source to provide real-time cell imaging and spatial cell monitoring for long-term free from phototoxicity. 2D projection imaging was implemented using a modular condenser lens to acquire high-contrast images. This enabled the long-term monitoring of cells, and the real-time monitoring of cell division and death. This system was able to image, by 2D projection, cells on the surface thinly coated with multiwalled carbon nanotubes, as well as living cells that migrated along the surface of glass beads and hydrogel droplets with a diameter of about 160 µm. The optimal incident light angle-fitted dark field system combines high-contrast imaging sensitivity and high spatial resolution to even image cells on 3D surfaces.


Assuntos
Lentes , Nanotubos de Carbono , Hidrogéis , Microscopia/métodos
6.
Micromachines (Basel) ; 13(4)2022 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-35457863

RESUMO

Recently, with the development of biomedical fields, the viscosity of prepolymer fluids, such as hydrogels, has played an important role in determining the mechanical properties of the extracellular matrix (ECM) or being closely related to cell viability in ECM. The technology for measuring viscosity is also developing. Here, we describe a method that can measure the viscosity of a fluid with trace amounts of prepolymers based on a simple flow-focused microdroplet generator. We also propose an equation that could predict the viscosity of a fluid. The viscosity of the prepolymer was predicted by measuring and calculating various lengths of the disperse phase at the cross junction of two continuous-phase channels and one disperse-phase channel. Bioprepolymer alginates and gelatin methacryloyl (GelMA) were used to measure the viscosity at different concentrations in a microdroplet generator. The break-up length of the dispersed phase at the cross junction of the channel gradually increased with increasing flow rate and viscosity. Additional viscosity analysis was performed to validate the standard viscosity calculation formula depending on the measured length. The viscosity formula derived based on the length of the alginate prepolymer was applied to GelMA. At a continuous phase flow rate of 400 uL/h, the empirical formula of alginate showed an error within about 2%, which was shown to predict the viscosity very well in the viscometer. Results of this study are expected to be very useful for hydrogel tuning in biomedical and tissue regeneration fields by providing a technology that can measure the dynamic viscosity of various prepolymers in a microchannel with small amounts of sample.

7.
Diagnostics (Basel) ; 11(10)2021 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-34679588

RESUMO

Assessment of carotid bulb hemodynamics using four-dimensional (4D) flow magnetic resonance imaging (MRI) requires accurate segmentation of recirculation regions that is frequently hampered by limited resolution. This study aims to improve the accuracy of 4D flow MRI carotid bulb segmentation and subsequent recirculation regions analysis. Time-of-flight (TOF) MRI and 4D flow MRI were performed on bilateral carotid artery bifurcations in seven healthy volunteers. TOF-MRI data was segmented into 3D geometry for computational fluid dynamics (CFD) simulations. ITK-SNAP segmentation software was included in the workflow for the semi-automatic generation of 4D flow MRI angiographic data. This study compared the velocities calculated at the carotid bifurcations and the 3D blood flow visualization at the carotid bulbs obtained by 4D flow MRI and CFD. By applying ITK-SNAP segmentation software, an obvious improvement in the 4D flow MRI visualization of the recirculation regions was observed. The 4D flow MRI images of the recirculation flow characteristics of the carotid artery bulbs coincided with the CFD. A reasonable agreement was found in terms of velocity calculated at the carotid bifurcation between CFD and 4D flow MRI. However, the dispersion of velocity data points relative to the local errors of measurement in 4D flow MRI remains. Our proposed strategy showed the feasibility of improving recirculation regions segmentation and the potential for reliable blood flow visualization in 4D flow MRI. However, quantitative analysis of recirculation regions in 4D flow MRI with ITK-SNAP should be enhanced for use in clinical situations.

8.
Nanomaterials (Basel) ; 11(9)2021 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-34578663

RESUMO

It is necessary to investigate effective energy storage devices that can fulfill the requirements of short-term and long-term durable energy outputs. Here, we report a simple one-pot hydrothermal technique through which to fabricate the MoS2/Te nanocomposite to be used as an effective electrode material for high-performance supercapacitors. Comprehensive characterization of the as-fabricated nanomaterial was performed using FESEM, HRTEM, XRD, FTIR, XPS, etc., as well as electrochemical characterizations. The electrochemical characterization of the as-fabricated nanocomposite electrode material showed a high specific capacitance of 402.53 F g-1 from a galvanostatic charge-discharge (GCD) profile conducted at 1 A g-1 current density. The electrode material also showed significant rate performance with high cyclic stability reaching up to 92.30% under 4000 cycles of galvanostatic charge-discharge profile at a current density of 10 A g-1. The highly encouraging results obtained using this simple synthetic approach demonstrate that the hetero-structured nanocomposite of MoS2/Te electrode material could serve as a promising composite to use in effective supercapacitors or energy storage devices.

10.
J Pers Med ; 11(4)2021 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-33808514

RESUMO

A multimodality approach was applied using four-dimensional flow magnetic resonance imaging (4D flow MRI), time-of-flight magnetic resonance angiography (TOF-MRA) signal intensity gradient (SIG), and computational fluid dynamics (CFD) to investigate the 3D blood flow characteristics and wall shear stress (WSS) of the cerebral arteries. TOF-MRA and 4D flow MRI were performed on the major cerebral arteries in 16 healthy volunteers (mean age 34.7 ± 7.6 years). The flow rate measured with 4D flow MRI in the internal carotid artery, middle cerebral artery, and anterior cerebral artery were 3.8, 2.5, and 1.2 mL/s, respectively. The 3D blood flow pattern obtained through CFD and 4D flow MRI on the cerebral arteries showed reasonable consensus. CFD delivered much greater resolution than 4D flow MRI. TOF-MRA SIG and CFD WSS of the major cerebral arteries showed reasonable consensus with the locations where the WSS was relatively high. However, the visualizations were very different between TOF-MRA SIG and CFD WSS at the internal carotid artery bifurcations, the anterior cerebral arteries, and the anterior communicating arteries. 4D flow MRI, TOF-MRA SIG, and CFD are complementary methods that can provide additional insight into the hemodynamics of the human cerebral artery.

11.
J Nanobiotechnology ; 19(1): 72, 2021 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-33750392

RESUMO

This review highlights current developments, challenges, and future directions for the use of invasive and noninvasive biosample-based small biosensors for early diagnosis of Alzheimer's disease (AD) with biomarkers to incite a conceptual idea from a broad number of readers in this field. We provide the most promising concept about biosensors on the basis of detection scale (from femto to micro) using invasive and noninvasive biosamples such as cerebrospinal fluid (CSF), blood, urine, sweat, and tear. It also summarizes sensor types and detailed analyzing techniques for ultrasensitive detection of multiple target biomarkers (i.e., amyloid beta (Aß) peptide, tau protein, Acetylcholine (Ach), microRNA137, etc.) of AD in terms of detection ranges and limit of detections (LODs). As the most significant disadvantage of CSF and blood-based detection of AD is associated with the invasiveness of sample collection which limits future strategy with home-based early screening of AD, we extensively reviewed the future trend of new noninvasive detection techniques (such as optical screening and bio-imaging process). To overcome the limitation of non-invasive biosamples with low concentrations of AD biomarkers, current efforts to enhance the sensitivity of biosensors and discover new types of biomarkers using non-invasive body fluids are presented. We also introduced future trends facing an infection point in early diagnosis of AD with simultaneous emergence of addressable innovative technologies.


Assuntos
Doença de Alzheimer/diagnóstico , Biomarcadores/sangue , Biomarcadores/líquido cefalorraquidiano , Técnicas Biossensoriais/métodos , Acetilcolina , Doença de Alzheimer/sangue , Doença de Alzheimer/líquido cefalorraquidiano , Peptídeos beta-Amiloides , Animais , Diagnóstico Precoce , Humanos , Limite de Detecção , Camundongos , MicroRNAs , Sensibilidade e Especificidade , Proteínas tau/sangue , Proteínas tau/líquido cefalorraquidiano
12.
Diagnostics (Basel) ; 10(11)2020 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-33182565

RESUMO

Above all, we would like to express our sincere thanks and appreciation for writing your comment on our research [...].

13.
Diagnostics (Basel) ; 10(7)2020 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-32664658

RESUMO

PURPOSE: To study the effect of the infusion of normal saline on hemodynamic changes in healthy volunteers using computational fluid dynamics (CFD) simulation. METHODS: Eight healthy subjects participated and 16 carotid arteries were used for the CFD analysis. A one-liter intravenous infusion of normal saline was applied to the participants to observe the hemodynamic variations. Blood viscosity was measured before and after the injection of normal saline to apply the blood properties on the CFD modeling. Blood viscosity, shear rate, and wall shear stress were visually and quantitatively shown for the comparison between before and after the infusion of normal saline. Statistical analyses were performed to confirm the difference between the before and after groups. RESULTS: After the infusion of normal saline, decreased blood viscosity was observed in the whole carotid artery. At the internal carotid artery, the recirculation zone with low intensity was found after the injection of normal saline. Increased shear rate and reduced wall shear stress was observed at the carotid bifurcation and internal carotid artery. The hemodynamic differences between before and after groups were statistically significant. CONCLUSIONS: The infusion of normal saline affected not only the overall changes of blood flow in the carotid artery but also the decrease of blood viscosity.

14.
Lab Chip ; 20(13): 2284-2295, 2020 06 30.
Artigo em Inglês | MEDLINE | ID: mdl-32478781

RESUMO

Most elderly patients after orthopedic and dental implant surgeries are exposed to cardiostimulants to reduce potential blood pressure-related risks of cardiovascular diseases. Such treatments lead to deconditioning of platelet function, which is an important factor in wound healing treatments. We introduced an innovative parylene-C coated microporous PDMS structure that can prevent the functional deconditioning of platelets caused by certain cardiostimulants. At different concentrations of cardiostimulants (IPR; isoprenaline and DA; dopamine), pre-activation, activation, and post-activation of platelets were intensively examined under mechanical and chemical stimulation mimicking the physiological environment on four different surfaces (glass, flat parylene-C coated glass (F-PPXC), microporous PDMS structure (P-PDMS), and parylene-C-coated microporous PDMS structure (S-PPXC)). The 3D microporous structure with parylene-C (S-PPXC) surface could attenuate the deconditioning of platelet function caused by IPR. Moreover, the S-PPXC surface further enhanced the DA-dependent stimulation of platelet function. The reason for this is that the 3D microporous structure with parylene-C S-PPXC induced stable and fast adhesion of platelets through increased surface roughness and softness, resulting in a significant enhancement of platelet activity. Therefore, we propose the use of functional S-PPXC surfaces as a novel strategy in the development of biomedical products.


Assuntos
Plaquetas , Dimetilpolisiloxanos , Idoso , Humanos , Polímeros , Xilenos
15.
Sensors (Basel) ; 20(9)2020 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-32349256

RESUMO

The three-dimensional volumetric application of conductive poly (3,4-ethylenedioxythiophene)/poly (4-styrenesulfonate) (PEDOT:PSS) to multiwalled carbon nanotubes (MWCNTs) has not been widely reported. In this study, the applicability of the 3D PEDOT:PSS-MWCNT composite for a gas sensor was investigated with different PEDOT:PSS concentrations. The gas-sensing performance of the 3D PEDOT:PSS-MWCNT composites was investigated using ethanol and carbon monoxide (CO) gas. Overall, in comparison with the pristine MWCNTs, as the PEDOT:PSS concentration increased, the 3D PEDOT:PSS-MWCNT composites exhibited increased conductivity and enhanced gas sensing performances (fast response and recovery times) to both ethanol and CO gases. Importantly, although the PEDOT:PSS coating layer reduced the number of sites for the adsorption and desorption of gas molecules, the charge-carrier transport between the gas molecules and MWCNTs was significantly enhanced. Thus, PEDOT:PSS can be chemically grafted to MWCNTs to enhance the connectivity and conductivity of a 3D network, leading to possible applications in gas sensors.

16.
Nanoscale ; 12(18): 9980-9990, 2020 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-32129408

RESUMO

We present multiple-bent multi-walled carbon nanotubes (MWCNTs) that enable the picomolar detection of C-reactive protein (CRP), which is considered to be a promising biomarker for various diseases. The MWCNTs were grown via chemical vapor deposition repeating the asymmetric catalytic CNT growth on atypical carbon nanoparticles that were generated by carbon coating on a silicon substrate. The multiple-bent MWCNTs with the carbon film (CF) possessed abundant hydrophilic functional groups (-COOH and -OH) at their bending sites, resulting in enhanced bioadhesion to collagen and platelets, compared to MWCNTs grown without a CF layer. Interestingly, the bent MWCNTs enhanced the reliability and sensitivity of the electrochemical detection at low CRP concentrations, possibly due to molecular affinity at the bent site. The bioactive bent MWCNTs can play a significant role in ultrasensitive biosensors to improve their detection limit, thereby achieving early detection and monitoring of CRP-related diseases such as cardiovascular events and melanoma.


Assuntos
Proteína C-Reativa/análise , Técnicas Eletroquímicas/métodos , Nanotubos de Carbono/química , Plaquetas/citologia , Plaquetas/metabolismo , Colágeno/química , Colágeno/metabolismo , Humanos , Interações Hidrofóbicas e Hidrofílicas , Limite de Detecção , Nanotubos de Carbono/toxicidade , Ativação Plaquetária/efeitos dos fármacos
17.
Diagnostics (Basel) ; 10(2)2020 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-31991621

RESUMO

PURPOSE: To analyze size-dependent hemodynamic factors [velocity, shear rate, blood viscosity, wall shear stress (WSS)] in unruptured cerebral aneurysms using computational fluid dynamics (CFD) based on the measured non-Newtonian model of viscosity. METHODS: Twenty-one patients with unruptured aneurysms formed the study cohort. Patient-specific geometric models were reconstructed for CFD analyses. Aneurysms were divided into small and large groups based on a cutoff size of 5 mm. For comparison between small and large aneurysms, 5 morphologic variables were measured. Patient-specific non-Newtonian blood viscosity was applied for more detailed CFD simulation. Quantitative and qualitative analyses of velocity, shear rate, blood viscosity, and WSS were conducted to compare small and large aneurysms. RESULTS: Complex flow patterns were found in large aneurysms. Large aneurysms had a significantly lower shear rate (235 ± 341 s-1)) than small aneurysms (915 ± 432 s-1) at peak-systole. Two times higher blood viscosity was observed in large aneurysms compared with small aneurysms. Lower WSS was found in large aneurysms (1.38 ± 1.36 Pa) than in small aneurysms (3.53 ± 1.22 Pa). All the differences in hemodynamic factors between small and large aneurysms were statistically significant. CONCLUSIONS: Large aneurysms tended to have complex flow patterns, low shear rate, high blood viscosity, and low WSS. The hemodynamic factors that we analyzed might be useful for decision making before surgical treatment of aneurysms.

18.
Diagnostics (Basel) ; 9(4)2019 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-31847224

RESUMO

PURPOSE: Knowledge of the hemodynamics in the vascular system is important to understand and treat vascular pathology. The present study aimed to evaluate the hemodynamics in the human carotid artery bifurcation measured by four-dimensional (4D) flow magnetic resonance imaging (MRI) as compared to computational fluid dynamics (CFD). METHODS: This protocol used MRI data of 12 healthy volunteers for the 3D vascular models and 4D flow MRI measurements for the boundary conditions in CFD simulation. We compared the velocities measured at the carotid bifurcation and the 3D velocity streamlines of the carotid arteries obtained by these two methods. RESULTS: There was a good agreement for both maximum and minimum velocity values between the 2 methods for velocity magnitude at the bifurcation plane. However, on the 3D blood flow visualization, secondary flows, and recirculation regions are of poorer quality when visualized through the 4D flow MRI. CONCLUSION: 4D flow MRI and CFD show reasonable agreement in demonstrated velocity magnitudes at the carotid artery bifurcation. However, the visualization of blood flow at the recirculation regions and the assessment of secondary flow characteristics should be enhanced for the use of 4D flow MRI in clinical situations.

19.
Biomed Microdevices ; 22(1): 1, 2019 11 28.
Artigo em Inglês | MEDLINE | ID: mdl-31781963

RESUMO

In this study, we propose a microchip that is sequentially capable of fluorescently staining and washing DNAs. The main advantage of this microchip is that it allows for one-step preparation of small amounts of solution without degrading microscopic bio-objects such as the DNAs, cells, and biomolecules to be stained. The microchip consists of two inlets, the main channel, staining zone, washing zone, and one outlet, and was processed using a femtosecond laser system. High molecular transport of rhodamine B to deionized water was observed in the performance test of the microchip. Results revealed that the one-step procedure of on-chip DNA staining and washing was excellent compared to the conventional staining method. The one-step preparation of stained and washed DNAs through the microchip will be useful for preparing small volumes of experimental samples.


Assuntos
DNA/química , Corantes Fluorescentes/química , Dispositivos Lab-On-A-Chip , Coloração e Rotulagem/instrumentação , Dimetilpolisiloxanos/química , Nylons/química
20.
Biofabrication ; 11(3): 035021, 2019 05 31.
Artigo em Inglês | MEDLINE | ID: mdl-31035262

RESUMO

Polydimethylsiloxane (PDMS)-based elastomers have become the de facto platform for various biomedical applications. But the stable attachment of biomolecules to PDMS for more robust and long-term performance of the PDMS-based devices has been a significant challenge, owing to its unique physical properties (e.g. hydrophobicity, dynamic molecular mobility). Herein, the PDMS membrane with tunable surface porosity is developed via high-pressure saturated steam technology in order to promote a strong and lasting bioadhesion to the PDMS membrane without additional processing steps. The resulting porous PDMS membranes demonstrate enhanced physical properties (e.g. Young's modulus, roughness, and air permeability), which is dependent on the membrane thickness. The bioactivity of porous PDMS membranes, evaluated by measuring the adhesion of various biomolecules and bioactivity of cells, shows significant improvement over conventional non-porous control. This effect can be attributed to the strong physical adsorption on the porous PDMS membrane by increased surface roughness and stiffness. In sum, the porous PDMS membrane provides a simple and yet highly effective platform to create bioactive surface for various biomedical devices.


Assuntos
Dimetilpolisiloxanos/química , Membranas Artificiais , Adesividade , Plaquetas/ultraestrutura , DNA/metabolismo , Humanos , Ativação Plaquetária , Polímeros/química , Porosidade , Xilenos/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...