Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Res Cardiol ; 2023 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-38117299

RESUMO

BACKGROUND: Anxiety and limited patient comprehension may pose significant barriers when informing elderly patients about complex procedures such as transcatheter aortic valve implantation (TAVI). OBJECTIVES: We aimed to evaluate the utility of medical graphics to improve the patient informed consent (IC) before TAVI. METHODS: In this prospective, randomized dual center study, 301 patients were assigned to a patient brochure containing medical graphics (Comic group, n = 153) or sham information (Control group, n = 148) on top of usual IC. Primary outcomes were patient understanding of central IC-related aspects and periprocedural anxiety assessed by the validated Spielberger State Trait Anxiety Inventory (STAI), both analyzed by cognitive status according to the Montreal Cognitive Assessment (MoCA). RESULTS: Patient understanding was significantly higher in the Comic group [mean number of correct answers 12.8 (SD 1.2) vs. 11.3 (1.8); mean difference 1.5 (95% CI 1.2-1.8); p < 0.001]. This effect was more pronounced in the presence of cognitive dysfunction (MoCA < 26) [12.6 (1.2) in the Comic vs. 10.9 (1.6) in the Control group; mean difference 1.8 (1.4-2.2), p < 0.001]. Mean STAI score declined by 5.7 (95% CI 5.1-6.3; p < 0.001) in the Comic and 0.8 points (0.2-1.4; p = 0.015) in the Control group. Finally, mean STAI score decreased in the Comic group by 4.7 (3.8-5.6) in cognitively impaired patients and by 6.6 (95% CI 5.8 to 7.5) in patients with normal cognitive function (p < 0.001 each). CONCLUSIONS: Our results prove beneficial effects for using medical graphics to inform elderly patients about TAVI by improving patient understanding and reducing periprocedural anxiety (DRKS00021661; 23/Oct/2020). Medical graphics entailed significant beneficial effects on the primary endpoints, patient understanding and periprocedural anxiety, compared to the usual patient informed consent (IC) procedure. Patient understanding of IC-related aspects was significantly higher in the Comic group, with a more pronounced benefit in patients with cognitive impairment (p for IC method and cognitive status < 0.001, respectively; p for IC method x MoCA category interaction = 0.017). There further was a significant decline of periprocedural anxiety in patients with and without cognitive impairment (p for IC method x measuring time point < 0.001; p for IC method x MoCA category x measuring time point interaction = 0.018).

2.
Herzschrittmacherther Elektrophysiol ; 23(2): 131-4, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22457167

RESUMO

A 73-year-old man with nonischemic cardiomyopathy underwent catheter ablation of ventricular tachycardia that had resulted in frequent shocks from his implanted cardiac resynchronization therapy defibrillator (CRT-D). Coexisting atrial fibrillation required AV node ablation which rendered the patient pacemaker dependent. During follow-up, recurrent episodes of dizziness occurred caused by inhibition of pacing due to oversensing of pectoral muscle myopotentials. Surgical revision was performed and the intraoperative examination revealed an intact integrated bipolar defibrillator lead with appropriate connections to the CRT-D header. The placement of an additional pace/sense lead completely resolved the patient's symptoms and no further myopotential oversensing was recorded.


Assuntos
Nó Atrioventricular/cirurgia , Desfibriladores Implantáveis/efeitos adversos , Eletrodos Implantados/efeitos adversos , Falha de Equipamento , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/prevenção & controle , Idoso , Humanos , Masculino , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...