Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Qual Life Res ; 28(10): 2821-2829, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31177411

RESUMO

PURPOSE: To examine the measurement properties of the German PROMIS short forms for pain intensity (PAIN), pain interference (PI) and physical function (PF) in orthopedic foot and ankle surgery patients. METHODS: Patient-rated outcomes were collected from consecutive patients of our foot and ankle registry before and 6 months after surgery. Measurement properties were tested according to the COnsensus-based Standards for the selection of health status Measurement Instruments (COSMIN). The German Foot Function Index (FFI-D) served as a legacy measure. RESULTS: 748 patients were included in our cross-sectional sample. Longitudinal and test-retest data were available for 202 and 65 patients, respectively. Construct validity of all short forms was good. All Cronbach's α and intraclass correlation coefficients were > 0.7. The smallest detectable change (SDC) was highest for PF (8.9) and lowest for PI (6.5). Minimal important change was 4 to 5 points and thus smaller than SDC for all instruments. We observed a baseline ceiling effect for PF. PI showed insufficiently correlated change scores with FFI-D disability change scores, and therefore failed the responsiveness testing. CONCLUSION: Our study showed some adequate psychometric properties, but also certain aspects regarding interpretability and responsiveness that researchers must be aware of when using PROMIS short forms of pain and function in foot and ankle surgery patients.


Assuntos
Articulação do Tornozelo/cirurgia , Pé/cirurgia , Medição da Dor/métodos , Dor/diagnóstico , Medidas de Resultados Relatados pelo Paciente , Psicometria/métodos , Qualidade de Vida/psicologia , Articulação do Tornozelo/fisiopatologia , Estudos Transversais , Feminino , Pé/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
2.
J Orthop Surg Res ; 14(1): 87, 2019 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-30902098

RESUMO

BACKGROUND: Recently, the AMADEUS (Area Measurement And DEpth Underlying Structures) grading system has been introduced to evaluate and grade osteochondral lesions prior to cartilage surgery. The AMADEUS score has not been connected to clinical data in order to test a potential clincial impact. PURPOSE: To examine the correlation between the AMADEUS score and preoperative patient-reported outcome measurements (PROMs). STUDY DESIGN: Case series METHODS: Patients treated with matrix-induced autologous chondrocyte implantation (MACI) were included in the study, unless exclusion criteria like BMI > 35, prior extensive meniscectomy or ongoing inflammatory arthritis were present. Preoperative magnetic resonance (MR) examinations were graded according to the standardized AMADEUS protocol. The final AMADEUS score was correlated with preoperative patient-reported outcome measurements (PROMs), including the IKDC (International Knee Documentation Committee), the Lysholm score, the Short-Form-12 (SF-12) score, and the Core Outcome Measures Index (COMI) score. RESULTS: A total of 50 patients with a mean age of 33.6 ± 11.5 years, a mean BMI of 25.1 ± 4.9, and a mean defect size of 2.3 ± 1.5 cm2 were included in the study. More severe cartilage defects, indicated by the AMADEUS grade (R = 0.35, p = 0.01) and the AMADEUS score (R = - 0.36, p = 0.01) as well as larger chondral defects (R = 0.32, p = 0.03) show a moderate correlation with the higher COMI scores. No correlative capacity was demonstrated for the AMADEUS score and the IKDC, Lysholm, and Tegner activity scores as well as for its subscales. CONCLUSION: There is a moderate correlation of the COMI and the AMADEUS score in patients treated with matrix-induced autologous chondrocyte implantation (MACI). All other patient-reported outcome measurement scores (PROMs) show no evidence of an association to the magnetic resonance-based AMADEUS score. CLINICAL RELEVANCE: The clinical and scientific implication of the COMI score as a PROM tool can be recommended when working with the AMADEUS score and patients undergoing MACI.


Assuntos
Doenças das Cartilagens/diagnóstico por imagem , Doenças das Cartilagens/cirurgia , Condrócitos/transplante , Medidas de Resultados Relatados pelo Paciente , Cuidados Pré-Operatórios/métodos , Índice de Gravidade de Doença , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cuidados Pré-Operatórios/tendências , Transplante Autólogo/tendências , Resultado do Tratamento
3.
J Patient Rep Outcomes ; 2: 31, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30294711

RESUMO

PURPOSE: To examine the measurement properties of the German International Knee Documentation Committee Subjective Knee Form (IKDC-SKF) in knee disorder patients. METHODS: Three hundred twelve consecutive patients undergoing surgery for anterior cruciate ligament, meniscus and/or cartilage injuries completed the IKDC-SKF, Lysholm Score, Tegner Activity Scale, and Short Form-12 Health Survey before and 6 months post-surgery. IKDC-SKF measurement properties were calculated and patients were also asked to rate the relevance/comprehensibility of the questionnaire items. RESULTS: Reliability was good with high Cronbach's alpha and intraclass correlation coefficients, and standard error of measurement values of 4.4 to 6.0. The smallest detectable change (SDC) ranged from 12.3 to 16.7 points. Validity was good with 90% of all hypotheses confirmed. Confirmatory factor analysis did not show adequate fitting indices within the model. Over half of the items were rated as essential, and all were well comprehended. The majority of hypotheses for responsiveness were confirmed. No floor and ceiling effects were observed. The area under the curve ranged from 0.82 to 0.89 and the minimal important difference was smaller than the SDC. CONCLUSIONS: The German IKDC-SKF is a reliable outcome measure with good hypotheses testing and responsiveness, but its MIC and structural/content validity need further analysis.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...