RESUMO
To evaluate the effect of acidic challenge on erosion depth and topographic characteristics of different materials used as occlusal sealants. Two hundred specimens of five sealant materials (Fuji IX, Ketac Molar, Fuji II, Equia and Clinpro) and forty bovine teeth enamel samples (control) were prepared and exposed to acidic challenge. The specimens were immersed in four different solutions (orange juice, coke drink, citric acid or distilled water) under mildly shaken conditions for 3 days. The erosion depth profiles were measured using a profilometer and Scanning Electron Microscope (SEM). Two-way ANOVA with Tukey post-hoc test was performed to evaluate the interactions. Sealant material and acidic challenge had significant effects on erosion depth. Among the materials, Fuji II presented the highest mean of erosion depth after immersion in orange juice, coke drink, and citric acid. All materials groups presented higher erosion depth values after immersion in the citric acid solution, except Clinpro. Bovine enamel presented higher erosion depth values compared to all materials when submitted to erosive challenge. Sealant materials submitted to the acidic challenge presented different degrees of erosion and topographic modification; however, they are less susceptible to erosion than bovine teeth enamel.
Assuntos
Ácido Cítrico , Esmalte Dentário , Teste de Materiais , Microscopia Eletrônica de Varredura , Selantes de Fossas e Fissuras , Propriedades de Superfície , Erosão Dentária , Bovinos , Animais , Erosão Dentária/prevenção & controle , Erosão Dentária/induzido quimicamente , Esmalte Dentário/efeitos dos fármacos , Selantes de Fossas e Fissuras/química , Análise de Variância , Fatores de Tempo , Propriedades de Superfície/efeitos dos fármacos , Cimentos de Ionômeros de Vidro/química , Cimentos de Ionômeros de Vidro/uso terapêutico , Reprodutibilidade dos Testes , Bebidas Gaseificadas/efeitos adversos , Valores de Referência , Concentração de Íons de Hidrogênio , Resinas Compostas/químicaRESUMO
STATEMENT OF PROBLEM: The influence of computer-aided manufacturing (CAM) parameters and settings on the outcomes of milled indirect restorations is poorly understood. PURPOSE: The purpose of this scoping review was to summarize the current CAM systems, parameters, and setting changes, and their effects on different outcomes of milled indirect restorations and aspects related to their manufacture. MATERIAL AND METHODS: The protocol of this review is available online (https://osf.io/x28ps/). Studies that used at least 2 different parameters (CAM units, number of axes, digital spacers, or protocols with different rotatory instruments, grit-sizes, milling speed, or others) for milling indirect restorations were included. A structured search up to July 2023 was performed by 2 independent reviewers for articles written in English in LILACS, MEDLINE via PubMed, EMBASE, Web of Science, and Scopus. RESULTS: Of 1546 studies identified, 22 were included in the review. Discrepancies were found between the planned and actual measured cement space, with a decreasing linear relationship impacting restoration adaptation at different points. The CEREC MC XL milling machine was the most used system in the included studies, with variations in bur types, milling modes, and number of burs uses affecting internal fit and surface trueness. The results demonstrated the better adaptation of restorations made with 5-axis over 3-axis milling machines. Lithium disilicate and zirconia were the most commonly used materials, and crowns and inlays were popular designs. Marginal and internal adaptation were the primary outcomes assessed using the various techniques. CONCLUSIONS: The study presented a comprehensive exploration of CAM systems and parameters, and their influence on indirect restorations. The planned cement space was not properly reproduced by the milling. Bur characteristics can affect restoration fit and trueness. The 5-axis units seem to result in better-adapted restorations compared with 3- and 4-axis units.
Assuntos
Desenho Assistido por Computador , Planejamento de Prótese Dentária , Humanos , Planejamento de Prótese Dentária/métodos , Restauração Dentária Permanente/métodos , Adaptação Marginal DentáriaRESUMO
OBJECTIVE: The aim of the present study was to evaluate the influence of multidirectional brushing on the surface roughness, morphology, and bonding interface of resin-repaired CAD-CAM ceramic and composite restorations. MATERIALS AND METHODS: Twelve (N = 12) blocks (4 mm × 4 mm × 2 mm for parallel axis; 5 mm × 4 mm × 2 mm for perpendicular axis) of lithium disilicate glass-ceramic (IPS e.max CAD, Ivoclar AG) and CAD-CAM resin composite (Tetric CAD, Ivoclar AG) were obtained and repaired with direct resin composite (Clearfil AP-X, Kuraray). An abrasive slurry was prepared and the brushing was performed according to each restorative material and axis of brushing (n = 6; perpendicular to repair interface and parallel to repair interface) during 3,650 cycles (240 strokes per minute) to simulate 3 years of brushing. The surface roughness (Ra) and the profile variation for each material (restoration and direct repair resin composite) were measured at the baseline condition and after brushing, and the mean roughness and presence of steps at the repair interface were evaluated through factorial analysis of Variance (ANOVA). Scanning Electron Microscopy (SEM) images were taken to evaluate the surface topography of the repaired materials after brushing. RESULTS: The mean roughness of the repaired CAD-CAM restorations was affected by the brushing (P < .05), mainly when evaluating the repair material and the interface (P < .05), while the restorative CAD-CAM materials presented more stable values. The profile evaluation showed higher steps at the interface when repairing lithium disilicate than for CAD-CAM resin composite. CONCLUSION: Repaired CAD-CAM restorations were susceptible to wear after brushing simulation. The surface roughness of the direct resin composite was the most affected leading to step development at the interface, particularly in the repaired lithium disilicate samples. Cinical maintenance recalls and polishing protocols must be considered to enhance the longevity of such restorations.
Assuntos
Cerâmica , Resinas Compostas , Desenho Assistido por Computador , Porcelana Dentária , Propriedades de Superfície , Escovação Dentária , Resinas Compostas/uso terapêutico , Cerâmica/química , Porcelana Dentária/química , Teste de Materiais , Restauração Dentária Permanente/métodos , Desgaste de Restauração Dentária , Microscopia Eletrônica de Varredura , Materiais Dentários/química , Humanos , Reparação de Restauração Dentária/métodosRESUMO
Despite the advancements in indirect monolithic restorations, technical complications may occur during function. To overcome this issues, intraoral repair using resin composite is a practical and low-cost procedure, being able to increase the restoration's longevity. This review aimed to evaluate the need for repair and suggest a standardized repair protocol to the main indirect restorative materials. For this, studies were surveyed from PubMed with no language or date restriction, to investigate the scientific evidence of indirect monolithic restoration repair with direct resin composite. A classification to guide clinical decisions was made based on the FDI World Dental Federation criteria about defective indirect restorations considering esthetic and functional standards, along with the patient's view, to decide when polishing, repairing or replacing a defective restoration. Based on 38 surveyed studies, different resin composite intraoral repair protocols, that included mechanical and chemical aspects, were defined depending on the substrate considering resin-based, glass-ceramic or zirconia restorations. The presented criteria and protocols were developed to guide the clinician's decision-making process regarding defective indirect monolithic restorations, prolonging longevity and increasing clinical success.
Assuntos
Resinas Compostas , Desenho Assistido por Computador , Humanos , Resinas Compostas/uso terapêutico , Resinas Vegetais , Inquéritos e QuestionáriosRESUMO
OBJECTIVE: The study aims to evaluate the shear bond and flexural strength fatigue behavior of yttrium-stabilized zirconia (4YSZ) repaired using different resin composites. MATERIALS AND METHODS: Cylindric specimens of 4YSZ were obtained for the bond strength (Ø = 6 mm, 1.5 mm of thickness) and biaxial flexural strength (Ø = 15 mm, 1 mm of thickness) fatigue tests and divided into 3 groups according to the repair resin composite: EVO (nanohybrid), BULK (bulk-fill), and FLOW (flowable). The zirconia surface was air-abraded with alumina particles, a 10-methacryloyloxydecyl dihydrogen phosphate (10-MDP) primer was applied, and the resin composite was build-up over the zirconia. Fatigue shear bond strength and flexural fatigue strength tests were performed (n = 15). One-way ANOVA and Tukey post hoc tests were carried out for both outcomes, besides scanning electron microscopy and finite element analysis. RESULTS: The repair material affected the fatigue shear bond strength of zirconia ceramic. The BULK group (18.9 MPa) depicted higher bond strength values than FLOW (14.8 MPa) (p = 0.04), while EVO (18.0 MPa) showed similar results to both groups. No effect was observed for the mechanical behavior (p = 0.53). The stress distribution was similar for all groups. CONCLUSION: The repair of yttrium-stabilized zirconia (4YSZ) ceramics with bulk-fill resin composites was the best option for high fatigue bond strength. However, the fatigue mechanical performance was similar regardless of the applied repair material. CLINICAL RELEVANCE: The repair of yttrium-stabilized zirconia (4YSZ) monolithic restorations may be performed with nanohybrid and bulk-fill resin composites in order to promote longevity in the treatment.
Assuntos
Colagem Dentária , Metacrilatos , Colagem Dentária/métodos , Propriedades de Superfície , Teste de Materiais , Resinas Compostas/química , Zircônio/química , Cerâmica/química , Resistência ao Cisalhamento , Ítrio/química , Cimentos de Resina/química , Análise do Estresse DentárioRESUMO
Objective: To evaluate the effect of different surface treatments on the morphology, shear bond, and flexural fatigue strength of a repaired translucent zirconia. Methods: Monolithic disc-shaped specimens of translucent zirconia were prepared and ground to simulate repair areas. Four groups underwent different treatments: Air-MDP (air-abrasion with alumina particles and 10-MDP primer), Si-Sil (silica-coated alumina particles with MDP-containing silane), Si-MDP (silica coating with 10-MDP primer), and Uni adhe (universal adhesive). After roughness measurements and treatments, repairs were done using resin composite. Shear bond and flexural (n = 15) fatigue tests were performed. Surface topography, interfacial analysis, fractographic, and finite element analysis were conducted. Results: The zirconia roughness was similar between the groups, however, the surface topography was modified according to the surface treatments. Si-Sil generated higher and more stable bond strength values (20.69 MPa) between translucent zirconia and resin composite when compared to Uni adhe (15.75 MPa) considering the fatigue bond strength scenario, while it was similar to Si-MDP (17.70 MPa) and Air-MDP (18.97 MPa). Regarding the mechanical behavior, Si-Sil (680.83 MPa) also showed higher and significantly different fatigue strength when compared to Uni adhe (584.55 MPa), while both were similar to Si-MDP (634.22 MPa) and Air-MDP (641.86 MPa). Conclusion: The association of mechanical and chemical approaches is essential for long-term bond strength and optimized mechanical behavior, being air-abrasion protocols and the use of silane and/or MDP-based primers suitable for zirconia repair protocols. It was found that relying solely on a universal adhesive was not as effective as other options available. Clinical significance: The surface treatment of repair protocols affects translucent zirconia's morphology. To enhance fatigue behavior in repaired monolithic zirconia, air abrasion is crucial. Exclusive use of a universal adhesive is less effective than other choices. A primer containing silane/MDP holds the potential for stable bond strength and optimized mechanical performance.
RESUMO
Abstract To evaluate the effect of acidic challenge on erosion depth and topographic characteristics of different materials used as occlusal sealants. Two hundred specimens of five sealant materials (Fuji IX, Ketac Molar, Fuji II, Equia and Clinpro) and forty bovine teeth enamel samples (control) were prepared and exposed to acidic challenge. The specimens were immersed in four different solutions (orange juice, coke drink, citric acid or distilled water) under mildly shaken conditions for 3 days. The erosion depth profiles were measured using a profilometer and Scanning Electron Microscope (SEM). Two-way ANOVA with Tukey post-hoc test was performed to evaluate the interactions. Sealant material and acidic challenge had significant effects on erosion depth. Among the materials, Fuji II presented the highest mean of erosion depth after immersion in orange juice, coke drink, and citric acid. All materials groups presented higher erosion depth values after immersion in the citric acid solution, except Clinpro. Bovine enamel presented higher erosion depth values compared to all materials when submitted to erosive challenge. Sealant materials submitted to the acidic challenge presented different degrees of erosion and topographic modification; however, they are less susceptible to erosion than bovine teeth enamel.
RESUMO
STATEMENT OF PROBLEM: The color of monolithic zirconia restorations is obtained by presintering or postsintering coloring techniques. However, studies on the differences in surface characteristics and their influence on color stability are lacking. PURPOSE: The purpose of this in vitro study was to evaluate the influence of shading and staining techniques for a zirconia ceramic on the surface characteristics and colorimetric parameters (color difference, translucency, and whiteness index) after exposure to coffee or red wine and then polishing. MATERIAL AND METHODS: Ceramic disks (N=30; Ø10×1mm) were allocated into 3 groups: preshaded-shaded by the manufacturer (IPS e.max ZirCAD MT, shade A2); manually shaded-unshaded zirconia (IPS e.max ZirCAD MT, bleaching shade-BL) colored by the brushing technique, before sintering; stained-unshaded zirconia (IPS e.max ZirCAD MT BL) colored by the staining technique, after sintering. Spectrophotometric color assessments ensured the same initial perceived color (Vita Classical A2) for specimens included in the study (∆E00<1.77 acceptability threshold). Surface characteristics were assessed by scanning electron microscopy and atomic force microscopy. The specimens were immersed in coffee (n=5) or red wine (n=5) for 12 and 24 days and subsequently polished. The data were statistically and descriptively analyzed for color differences (∆E00), translucency parameters (TP00), and whiteness indexes for dentistry (WID), considering acceptability and perceptibility thresholds. RESULTS: The shaded groups found an irregular ceramic surface with uniformly sized zirconia crystals. The stained group found a glass-covered smoother surface. Significant alterations in color parameters (∆E00, TP00, WID) were observed with immersion in pigmenting beverages (P<.001) both after 12 days, and after 24 days. The shaded specimens had greater color alterations after immersion but benefited from the polishing procedure, which reduced color differences below an acceptable threshold in comparison with the baseline. Stained specimens had lower color alterations after immersion, but the polishing protocol was detrimental as it whitened the ceramic by subsurface exposure. CONCLUSIONS: The coloring technique influences the surface characteristics of zirconia ceramic and also the color parameters after exposure to colored beverages and polishing.
Assuntos
Cerâmica , Café , Cor , Teste de Materiais , Propriedades de Superfície , Cerâmica/química , Zircônio/química , Porcelana DentáriaRESUMO
Com base no desenvolvimento da odontologia adesiva, restaurações minimamente invasivas em cerâmica são utilizadas como alternativas para restaurar um dente. As cerâmicas odontológicas são amplamente aplicadas na área odontológica principalmente devido à sua estética e resistência mecânica. Uma das propriedades da cerâmica a ser bem conhecida antes de seu uso, é a resistência ao desgaste que deve ser compatível com o comportamento de desgaste do antagonista para evitar desempenhos indesejados. Portanto, vários métodos têm sido realizados para avaliar o comportamento do desgaste dos materiais cerâmicos considerando diferentes condições presentes no complexo meio oral. Este estudo teve como objetivo compilar os métodos utilizados para investigar o desgaste das cerâmicas odontológicas e descrever os mecanismos de desgaste envolvidos nos mesmos. A obtenção e análise de dados também é abordada para discutir os resultados obtidos a partir de diferentes métodos, bem como a análise clínica do desgaste e perspectivas futuras sobre esse tema. Em conclusão, muitas metodologias estão disponíveis para medir o desgaste cerâmico. Portanto, os métodos devem ser selecionados com base na relevência clínica de cada estudo e devem seguir parâmetros previamente relatados para padronização, permitindo a comparação da literatura (AU)
Based on the development of adhesive dentistry, minimally invasive restorations in ceramics are used as alternatives to restore a tooth. Dental ceramics are largely applied in the dentistry field mainly due to their esthetic and mechanical strength. One of the ceramic properties to be well known before its use is the wear resistance that should be compatible with the antagonist wear behavior to avoid unwanted performance. Therefore, several methods have been performed to assess the ceramic materials wear behavior considering different conditions present in the complex oral medium. This study aimed to compile the methods used to investigate dental ceramics wear and to describe the wear mechanisms involved on them. Obtaining and analyzing data is also addressed to discuss the results obtained from different methods, as well as the clinical analysis of wear and future perspectives on this topic. In conclusion, many methodologies are available to measure the ceramic wear. Therefore, the methods must be selected based on the clinical significance of each study and should follow previously reported parameters for standardization, allowing literature comparison. (AU)
Assuntos
Ligas Metalo-Cerâmicas , Desgaste de Restauração Dentária , Materiais Dentários , Desgaste dos Dentes , MétodosRESUMO
It aims on evaluate the effect of the test environment on static fatigue behavior of lithium disilicate-based (LD), and yttrium oxide-stabilized zirconia (YSZ) ceramics. Specimens of LD (IPS e.max CAD, Ivoclar Vivadent) and YSZ (IPS e.max ZirCAD MO, 3 mol% Y2O3, Ivoclar Vivadent) were randomly allocated into three groups: tested in air, inert (paraffin oil, Sigma Aldrich) or distilled water. The static fatigue test (n=15) was performed using a piston-on-three ball assembly, adapted from ISO 6872, as follows: starting load 100 N for LD and 300 N for YSZ; loading application time set to 1 hour for each loading step; step size of 50 N for LD and 100 N for YSZ, applied successively until fracture. Data from static fatigue strength (MPa) and time to fracture (hours) were recorded. Fractographic analysis was executed. Survival analysis corroborates absence of influence of environment on static fatigue outcomes (fatigue strength, time to fracture and survival rates) for YSZ. For LD, specimens tested in air presented statistically superior survival rate and static fatigue strength (p= 0.025). In regards of time to fracture, LD tested in air were superior than when tested in distilled water (p=0.019) or inert (p=0.017) environments. No statistical differences for Weibull modulus were observed. Failures started on the tensile stress surface. Thus, the test environment did not affect slow crack growth (SCG) mechanisms during static fatigue test of YSZ ceramics, but it plays a significant role for the static fatigue behavior of lithium disilicate-based glass ceramics, indicating a high susceptibility to SCG.
Assuntos
Cerâmica , Porcelana Dentária , Desenho Assistido por Computador , Análise do Estresse Dentário , Vidro , Teste de Materiais , Propriedades de Superfície , ZircônioRESUMO
Abstract This study aimed to investigate the effect of surface roughness (polished vs. CAD/CAM milling simulation) on impact strength of five dental ceramics for manufacturing CAD/CAM monolithic restorations. Specimens of five ceramics (FC- feldspathic glass-ceramic; PICN- polymer-infiltrated ceramic-network; ZLS- zirconia-reinforced lithium silicate glass-ceramic; LD- lithium disilicate glass-ceramic; YZ- yttria-stabilized tetragonal zirconia polycrystal ceramic) to be tested under impact (15×10×2mm3; n= 15) were divided into two groups, according to surface treatment: polishing (pol) and grinding (gri) as CAD/CAM milling simulation. Impact strength was tested using the Dynstat method. Roughness, topographic, fractographic and finite element analyses were performed. The impact strength data were analyzed by Weibull, and Pearson correlation was used to correlate roughness and impact strength data. The CAD/CAM milling simulation led to significantly (p<0.05) greater roughness (Ra and Rz) and statistically reduced the impact strength for PICN (polPICN= 4.59 to griPICN= 1.09; ±76% decrease), for LD (polLD= 17.69 to griLD= 10.09; ±43% decrease) and for YZ (polYZ= 74.99 to griYZ= 20.67; ±72% decrease) ceramics; and also promoted a more irregular topography with scratches and grooves. Fractographic and FEA analyses depicted the origin of failure at the higher stress concentration side during the impact test, where the pendulum impacted. The CAD/CAM milling simulation significantly decreased the impact strength of the evaluated ceramic materials.
Resumo Este estudo teve como objetivo investigar o efeito da rugosidade da superfície (polido vs. simulação da usinagem em CAD/CAM) na resistência ao impacto de cinco cerâmicas odontológicas indicadas na fabricação de restaurações monolíticas em CAD/CAM. Espécimes de cinco cerâmicas (FC- vitrocerâmica feldspática; PICN- rede de cerâmica infiltrada com polímero; ZLS- vitrocerâmica de silicato de lítio reforçada com zircônia; LD- vitrocerâmica de dissilicato de lítio; YZ- cerâmica policristalina de zircônia tetragonal estabilizada com ítria), a serem testados sob impacto (15 × 10 × 2mm3; n= 15), foram divididos em dois grupos, de acordo com o tratamento superficial: polimento (pol) e desgaste (gri), usado como simulação da usinagem em CAD/CAM. A resistência ao impacto foi testada usando o método Dynstat. Foram realizadas as análises de rugosidade, topografia, fractografia e análise de elementos finitos. Os dados de resistência ao impacto foram analisados pela análise de Weibull, e a correlação de Pearson foi usada para correlacionar os dados de rugosidade e resistência ao impacto. A simulação da usinagem em CAD/CAM levou a uma rugosidade (Ra e Rz) significativamente maior (p < 0,05) para todas as cerâmicas, e reduziu estatisticamente a resistência ao impacto para as cerâmicas PICN (polPICN = 4,59 para griPICN = 1,09; redução de ± 76%), LD (polLD = 17,69 para griLD = 10,09; ± 43% de redução) e YZ (polYZ = 74,99 para griYZ = 20,67; ± 72% de redução); e também promoveu uma topografia mais irregular apresentando riscos e sulcos acentuados. As análises de fractografia e de elementos finitos mostraram a origem da falha no lado de maior concentração de tensão durante o teste de impacto, onde o pêndulo impactou o espécime. A simulação da usinagem em CAD/CAM reduziu significativamente a resistência ao impacto dos materiais cerâmicos avaliados.
RESUMO
OBJECTIVE: To evaluate the effect of surface treatments on optical, colorimetric, and surface characteristics of lithium disilicate glass-ceramic. MATERIALS AND METHODS: Specimens (n = 5, IPS e.max CAD) were randomly allocated to the following treatments: mirror-polished: SiC papers; as-cut: mimicking CAD-CAM milling; ground: 90-120 µm-grit diamond bur; ground polished: ground, finished (46-30 µm-grit diamond bur), polished (diamond cups, brush and diamond paste); ground glazed: ground, glazed; ground polished glazed: association of methods. CIELAB color coordinates were obtained by a spectrophotometer. CIEDE2000 color differences (ΔE00 ) and the translucency parameter (TP00 ) were calculated. Light transmittance was assessed with a colorimeter. Surface characteristics (topography and roughness) were analyzed. Statistical differences for each condition and outcome were detected using one-way ANOVA with Tukey's post-hoc test (α = 0.05). RESULTS: TP00 data show statistical reduction after grinding (p < 0.05), which was only restored with polishing (solely or with glazing). ΔE00 shows that grinding results in perceptible variations in color (above 0.81), which were restored after all post-processing protocols (exception to only glaze application in contact with a black background). Light transmittance data corroborated such performance. Polishing and glazing reduced roughness and improved surface topography. CONCLUSION: Grinding statistically increased roughness, reduced translucency, light transmittance through the ceramic, and resulted on color differences. On contrary, polishing (followed or not by glazing) reduced roughness and enhanced ceramic translucency and light transmittance. Glaze also reduced roughness, but it still presented reduced translucency. The positioning (facing up or down) of the ceramic treated surface influenced the considered outcomes. CLINICAL SIGNIFICANCE: Grinding with diamond burs results in a deleterious impact to the optical, colorimetric and surface characteristics of lithium disilicate ceramic. Thus, polishing (followed or not by glazing) is recommended for optical and topographical enhancements when lithium disilicate monolithic restorations require occlusal adjustments.
Assuntos
Colorimetria , Polimento Dentário , Cerâmica , Porcelana Dentária , Teste de Materiais , Propriedades de SuperfícieRESUMO
Abstract It aims on evaluate the effect of the test environment on static fatigue behavior of lithium disilicate-based (LD), and yttrium oxide-stabilized zirconia (YSZ) ceramics. Specimens of LD (IPS e.max CAD, Ivoclar Vivadent) and YSZ (IPS e.max ZirCAD MO, 3 mol% Y2O3, Ivoclar Vivadent) were randomly allocated into three groups: tested in air, inert (paraffin oil, Sigma Aldrich) or distilled water. The static fatigue test (n=15) was performed using a piston-on-three ball assembly, adapted from ISO 6872, as follows: starting load 100 N for LD and 300 N for YSZ; loading application time set to 1 hour for each loading step; step size of 50 N for LD and 100 N for YSZ, applied successively until fracture. Data from static fatigue strength (MPa) and time to fracture (hours) were recorded. Fractographic analysis was executed. Survival analysis corroborates absence of influence of environment on static fatigue outcomes (fatigue strength, time to fracture and survival rates) for YSZ. For LD, specimens tested in air presented statistically superior survival rate and static fatigue strength (p= 0.025). In regards of time to fracture, LD tested in air were superior than when tested in distilled water (p=0.019) or inert (p=0.017) environments. No statistical differences for Weibull modulus were observed. Failures started on the tensile stress surface. Thus, the test environment did not affect slow crack growth (SCG) mechanisms during static fatigue test of YSZ ceramics, but it plays a significant role for the static fatigue behavior of lithium disilicate-based glass ceramics, indicating a high susceptibility to SCG.
Resumo O presente estudo objetivou investigar a influência do ambiente de teste no comportamento a fadiga estática (resistência à fratura e tempo para falha) de cerâmicas à base de dissilicato de lítio (LD) e zircônia estabilizada com ítria (YSZ). Espécimes de LD (IPS e.max CAD, Ivoclar Vivadent) e YSZ (IPS e.max ZirCAD MO, 3mol% Y2O3, Ivoclar Vivadent) foram obtidos e alocados aleatoriamente em três grupos: testado em ar, em líquido inerte (óleo de parafina) ou em água destilada. O teste de fadiga estática (n= 15) foi realizado usando o teste pistão sobre três esferas, ISO 6872, da seguinte forma: carga inicial 100 N para LD e 300 N para YSZ; tempo de aplicação de carregamento definido para 1 hora para cada etapa de carregamento; tamanho do passo de 50 N para LD e 100 N para YSZ, aplicados sucessivamente até a fratura. Dados de resistência à fadiga estática (MPa) e tempo até a fratura (horas) foram registrados. A análise fractográfica foi executada. A análise de sobrevivência corrobora a ausência de influência do ambiente de teste nos resultados de fadiga estática (resistência à fadiga, tempo de fratura e taxas de sobrevivência) para a YSZ. Para LD, os corpos de prova testados em ar apresentaram taxa de sobrevivência e resistência à fadiga estática estatisticamente superiores (p= 0,025). Em relação ao tempo de fratura, os espécimes LD testados em ar foram superiores aos testados em água destilada (p= 0,019) ou em ambiente inerte (p= 0,017). Não foram observadas diferenças estatísticas para o módulo de Weibull. Todas as falhas começaram no lado onde se concentra a tensão de tração (lado de baixo) durante o teste. Com base nisso, observa-se que o ambiente de teste não afetou os mecanismos de crescimento lento de trinca durante o teste de fadiga estática da cerâmica YSZ, mas desempenha um papel significativo na resistência à fadiga estática da cerâmica de vidro à base de dissilicato de lítio, indicando alta susceptibilidade ao crescimento lento e subcrítico de trincas.
Assuntos
Cerâmica , Porcelana Dentária , Propriedades de Superfície , Zircônio , Teste de Materiais , Desenho Assistido por Computador , Análise do Estresse Dentário , VidroRESUMO
This study aimed to investigate the effect of surface roughness (polished vs. CAD/CAM milling simulation) on impact strength of five dental ceramics for manufacturing CAD/CAM monolithic restorations. Specimens of five ceramics (FC- feldspathic glass-ceramic; PICN- polymer-infiltrated ceramic-network; ZLS- zirconia-reinforced lithium silicate glass-ceramic; LD- lithium disilicate glass-ceramic; YZ- yttria-stabilized tetragonal zirconia polycrystal ceramic) to be tested under impact (15×10×2mm3; n= 15) were divided into two groups, according to surface treatment: polishing (pol) and grinding (gri) as CAD/CAM milling simulation. Impact strength was tested using the Dynstat method. Roughness, topographic, fractographic and finite element analyses were performed. The impact strength data were analyzed by Weibull, and Pearson correlation was used to correlate roughness and impact strength data. The CAD/CAM milling simulation led to significantly (p<0.05) greater roughness (Ra and Rz) and statistically reduced the impact strength for PICN (polPICN= 4.59 to griPICN= 1.09; ±76% decrease), for LD (polLD= 17.69 to griLD= 10.09; ±43% decrease) and for YZ (polYZ= 74.99 to griYZ= 20.67; ±72% decrease) ceramics; and also promoted a more irregular topography with scratches and grooves. Fractographic and FEA analyses depicted the origin of failure at the higher stress concentration side during the impact test, where the pendulum impacted. The CAD/CAM milling simulation significantly decreased the impact strength of the evaluated ceramic materials.
Assuntos
Cerâmica , Porcelana Dentária , Desenho Assistido por Computador , Teste de Materiais , Silicatos , Propriedades de Superfície , ZircônioRESUMO
PURPOSE: To assess stress distribution in full-crowns with a composite buildup and endocrowns under axial or oblique loads, both with different ferrules (1 or 2 mm) and ceramic materials (glass ceramic or hybrid ceramic). MATERIALS AND METHODS: Sixteen models were analyzed with finite element analysis. No-separation contacts were considered between restoration/resin cement and resin cement/tooth. The contact between the fixation cylinder and the root was considered perfectly bonded. The axial load was applied to the occlusal surface and the oblique load was applied to the buccal cusp. The resulting tensile stresses were shown for the crown, the cement layer and the tooth. RESULTS: Almost all factors influenced the stress distribution significantly in the crown and the cement layer, as well as the tooth. The only exception was found under oblique loading by the restoration material and the type of crown that were of no significant influence on the stress distribution in the tooth. CONCLUSIONS: Under axial load, the endocrown showed the least tensile stresses in the tooth, but under oblique loads, the full-crown showed less tensile stresses than the endocrown. With the hybrid ceramic material, lower stresses were found in the crown, but higher stresses were present in the cement layer. The 2 mm ferrule is beneficial for reducing the resulting tensile stresses in all modalities.
Assuntos
Coroas , Porcelana Dentária , Materiais Dentários , Análise do Estresse Dentário , Análise de Elementos Finitos , Teste de MateriaisRESUMO
PURPOSE: This study evaluated the influence of prosthesis weight and number of implants on the bone tissue microstrain. MATERIALS AND METHODS: Fifteen (15) fixed full-arch implant-supported prosthesis designs were created using a modeling software with different numbers of implants (4, 6, or 8) and prosthesis weights (10, 15, 20, 40, or 60 g). Each solid was imported to the computer aided engineering software and tetrahedral elements formed the mesh. The material properties were assigned to each solid with isotropic and homogeneous behavior. The friction coefficient was set as 0.3 between all the metallic interfaces, 0.65 for the cortical bone-implant interface, and 0.77 for the cancellous bone-implant interface. The standard earth gravity was defined along the Z-axis and the bone was fixed. The resulting equivalent strain was assumed as failure criteria. RESULTS: The prosthesis weight was related to the bone strain. The more implants installed, the less the amount of strain generated in the bone. The most critical situation was the use of a 60 g prosthesis supported by 4 implants with the largest calculated magnitude of 39.9 mm/mm, thereby suggesting that there was no group able to induce bone remodeling simply due to the prosthesis weight. CONCLUSION: Heavier prostheses under the effect of gravity force are related to more strain being generated around the implants. Installing more implants to support the prosthesis enables attenuating the effects observed in the bone. The simulated prostheses were not able to generate harmful values of peri-implant bone strain.
RESUMO
BACKGROUND/AIMS: There is a lack of data regarding the mechanical responses of the temporo-mandibular joints during an impact to the orofacial region. The aim of this study was to analyze the biomechanical effects of wearing a mouthguard (MG) on the impact response of the mandibular condyle and articular disk according to the type of occlusion. The hypothesis was that the MG would minimize the effect in those structures, regardless of the occlusion type. METHODS: Using modeling software, a human skull with jaw, teeth and articular disk was created. The models were divided according to the occlusion type (Class I, II, or III) and the presence of a mouthguard (with or without). The geometries were exported to analysis software, and the materials were considered ideal. Fixation occurred at the base of the foramen magnum. The load (0-500N, 1s) was applied to the upper central incisors with a steel ball. Maximum principal stress and Von Mises results (MPa) were obtained in the mandibular condyle and articular disk. Minimum principal stress and maximum shear stresses were also recorded in the articular disk. RESULTS: For both structures, the MG caused a decrease in stress concentration regardless of the occlusion and stress criteria. The condyle neck was the most tensile-stressed area while for the articular disk, both the superior and inferior surfaces were the most stressed areas. The highest stress peaks in the disk were found for compression followed by tensile and then shear stress. CONCLUSION: This biomechanical analysis of the effects of using a mouthguard exhibited considerably decreased stresses on the mandibular condyle and articular disk, regardless of the occlusion type.
Assuntos
Protetores Bucais , Análise de Elementos Finitos , Humanos , Côndilo Mandibular , Estresse Mecânico , Articulação TemporomandibularRESUMO
OBJECTIVE: High viscous glass ionomer cement (GIC) has gained popularity as a restorative material; however, high wear is pointed as one of the major drawbacks of this material. Protective surface coatings were developed to protect GIC from water contamination with the additional advantage of occluding any surface cracks or porosities commonly found in this material, possibly resulting in an increased wear resistance of the restorations. The objective of this study was to investigate the clinical wear of GIC approximal restorations in primary molars protected either with a nanofilled self-adhesive light-cured protective coating (NPC) or with petroleum jelly. MATERIAL AND METHODS: Approximal caries lesions in primary molars from 32 schoolchildren previously enrolled in another clinical trial were included in this investigation. GIC restorations were performed according to the Atraumatic Restorative Treatment approach and protected with either petroleum jelly or a NPC. Impressions of the restored hemiarch were done after 1 day and 6, 12, 24 and 36 months. The impressions were scanned in a 3-D appliance and the obtained images were superimposed using an appropriate computer software. Two-way ANOVA for repeated measures and Tukey's post-hoc test were used to analyze the wear of restorations (α=5%). RESULTS: A significant difference was found between the two groups, with a wear protection offered by the application of a NPC. Conclusion: These results suggest that the application of a NPC has a protective effect on the clinical wear of approximal GIC restorations in primary teeth.
Assuntos
Cimentos de Ionômeros de Vidro/química , Vaselina/química , Cimentos de Resina/química , Desgaste dos Dentes/prevenção & controle , Análise de Variância , Criança , Tratamento Dentário Restaurador sem Trauma/métodos , Falha de Restauração Dentária , Feminino , Humanos , Masculino , Teste de Materiais , Reprodutibilidade dos Testes , Propriedades de Superfície , Fatores de Tempo , Dente Decíduo , Resultado do TratamentoRESUMO
This study investigated the effect of etching with distinct hydrofluoric (HF) acid concentrations on the cyclic load-to-failure (CLf) of simplified lithium disilicate glass-ceramic restorations adhesively cemented to a dentin analogue (nâ¯=â¯20): non-etched/control (CTRL), or etched for 20â¯s with HF acid at 3% (HF3), 5% (HF5), or 10% (HF10). A silane coating was then applied onto the ceramic surfaces. Fatigue tests followed the staircase approach (initial load= 720â¯N; step-size= 70â¯N; 500,000 cycles per sample; 20â¯Hz) using a hemispheric stainless-steel piston (Ø= 40â¯mm) under water. The CLf data were analyzed using Dixon and Mood method. Topographic and fractographic analyses were conducted. CLf (in N) of HF3 (1355⯱â¯32.0) and HF5 (1335⯱â¯58.8) groups were the highest and statistically similar; HF10 presented intermediate CLf (1175⯱â¯132.9), while the non-etched group had the lowest one (965⯱â¯145.0). Topographical analysis showed that the higher the HF acid concentration, the more pronounced the topographical changes. All failures (radial cracks) started from the inner surface of the ceramic discs. Topographical changes promoted by intermediate HF acid concentrations (3% and 5%) may improve fatigue performance for adhesively-cemented lithium disilicate restorations.
Assuntos
Porcelana Dentária/química , Falha de Restauração Dentária , Ácido Fluorídrico/química , Animais , Teste de Materiais , Suporte de CargaRESUMO
STATEMENT OF PROBLEM: Computer-aided design and computer-aided manufacturing (CAD-CAM) restorations are in contact with the antagonist tooth, either a natural tooth or a restoration. Therefore, clinicians should be aware of the wear resistance of CAD-CAM materials and the wear behavior of the antagonist. PURPOSE: The purpose of this in vitro study was to evaluate the wear resistance and abrasiveness of CAD-CAM materials. MATERIAL AND METHODS: In a 2-body wear test, the materials IPS e.max CAD (Ivoclar Vivadent AG), Vita Suprinity (Vita Zahnfabrik), Lava Ultimate (3M ESPE), Vita Enamic (Vita Zahnfabrik), and Lava Plus (3M ESPE) acted as abraders and, together with bovine enamel, also as antagonists. Each antagonist wheel ran against each abrader wheel for 200000 cycles, with a spring force of 15 N, and at a rotational speed of 1 Hz in distilled water. The wear rate was determined with a surface profilometer. The surfaces were observed with scanning electron microscopy, and their hardness, coefficient of friction, and roughness were evaluated. RESULTS: Lava Plus and IPS e.max CAD exhibited the highest potential for wear of Lava Ultimate. These 2 materials, together with Vita Suprinity, provided the highest wear of enamel and Vita Enamic. Vita Suprinity and IPS e.max CAD had higher wear than Lava Plus, and the inverse was also true. Vita Enamic and Lava Ultimate were among the materials that caused the lowest wear of enamel and all other evaluated materials. Scanning electron microscopy images revealed that except for Lava Ultimate, all other materials damaged enamel, in which Vita Suprinity and IPS e.max CAD were more aggressive when sliding against the materials. Lava Plus had the greatest hardness, followed by Vita Suprinity and IPS e.max CAD, Vita Enamic, and then Lava Ultimate. The coefficient of friction varied from 0.42 to 0.53. The Vita Enamic and Lava Ultimate showed the highest surface roughness. CONCLUSIONS: The nanofilled composite resin and polymer-infiltrated ceramic were more antagonist-friendly (whether enamel or CAD-CAM material) than glass-ceramics and zirconia. Care should be taken when selecting the material that will contact mainly with glass-ceramics. Hardness should also be considered when selecting a material.