Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 56
Filtrar
1.
J Cardiovasc Electrophysiol ; 35(3): 501-504, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38174843

RESUMO

INTRODUCTION: We report the case of an 18-year-old female with recurrent syncope that was discovered to have congenital long QT syndrome (LQTS) and episodes of a transiently short QT interval after spontaneous termination of polymorphic ventricular tachycardia. METHODS & RESULTS: A cardiac event monitor revealed a long QT interval and initiation of polymorphic ventricular tachycardia by a premature ventricular complex on the preceding T-wave. After 1 minute of ventricular fibrillation, her arrhythmia spontaneously terminated with evidence of a short QT interval. CONCLUSIONS: A transient, potentially artificial, short QT interval following Torsades de Pointes can occur in patients with LQTS.


Assuntos
Síndrome do QT Longo , Taquicardia Ventricular , Torsades de Pointes , Humanos , Feminino , Adolescente , Torsades de Pointes/diagnóstico , Torsades de Pointes/etiologia , Eletrocardiografia , Arritmias Cardíacas , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia
2.
JACC Clin Electrophysiol ; 10(1): 31-39, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37943190

RESUMO

BACKGROUND: Bilateral cardiac sympathetic denervation (BCSD) for refractory life-threatening ventricular arrhythmias is a neuromodulatory intervention targeting sympathetically driven focal or re-entrant ventricular arrhythmias. OBJECTIVES: This study sought to provide a more complete and successful option for intervention in patients in whom premature ventricular contraction (PVC) ablation is not feasible or has been unsuccessful. METHODS: A total of 43 patients with >5% PVC burden and concomitant nonischemic cardiomyopathy (NICM) who previously failed medical and ablation therapies were referred for BCSD. All patients underwent bilateral video-assisted thoracoscopic surgical approach with T1-T4 sympathectomy. Primary effectiveness endpoints were postprocedural PVC burden resolution, improvement in left ventricular ejection fraction (LVEF), and cessation of antiarrhythmic drugs (AADs). Safety endpoints included peri- and postprocedural complications. Outcomes were assessed over a 1-year follow-up period. RESULTS: Among the 43 patients who underwent BCSD, the mean age was 52.3 ± 14.7 years, 69.8% of whom were male patients. Presenting mean LVEF was 38.7% ± 7.8%, and PVC burden was 23.7% ± 9.9%. There were significant reductions in PVC burden postprocedurally (1.3% ± 1.1% post-BCSD, compared with 23.7% ± 9.9% pre-BCSD, P < 0.001) and improvements in LVEF (46.3% ± 9.5% post-BCSD, compared with 38.7% ± 7.8% pre-BCSD, P < 0.001). The rate of ICD therapies decreased from 81.4% (n = 35) to 11.6% (n = 5) (P < 0.001), leading to a significant reduction in use of AADs (100.0% to 11.6%, P < 0.001) and improvement in mean NYHA functional class (2.5 ± 0.5 to 1.4 ± 0.2, P < 0.001). Major intraoperative complications were seen in 4.7% of patients (hemothorax and chylothorax). Of the patients, 81.4% (n = 35) experienced no mortality or major complications over a 1-year follow-up period, with the remaining still within their first year postprocedure. CONCLUSIONS: BCSD is effective for the management of refractory PVCs and ventricular tachycardia who have failed previous ablation therapy.


Assuntos
Cardiomiopatias , Complexos Ventriculares Prematuros , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Idoso , Feminino , Volume Sistólico , Função Ventricular Esquerda , Antiarrítmicos/uso terapêutico , Simpatectomia/efeitos adversos , Simpatectomia/métodos
3.
J Interv Card Electrophysiol ; 67(3): 625-635, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37858000

RESUMO

BACKGROUND: Frailty is associated with significant morbidity and mortality and may have clinical implications in an advanced age population with atrial fibrillation undergoing left atrial appendage occlusion (LAAO). We sought to develop a novel frailty scale to predict worse outcomes in patients undergoing LAAO. METHODS: Patients in the NCDR LAAO Registry between 2016 and 2021 receiving percutaneous LAAO devices were categorized as non-frail (0 points), pre-frail (1-3 points), or frail (4-5 points) based on a 5-point scale representing multiple domains of frailty: hemoglobin <13.0 g/dL in male, <12.0 g/dL in female; creatinine ≥1.2 mg/dL; albumin <3.5 g/dL; body mass index <20 kg/m2; and increased risk of falls. RESULTS: Of 57,728 patients, 44,360 (76.8%) were pre-frail and 7693 (13.3%) were frail. Compared to non-frail, pre-frail and frail patients were older, had a higher burden of co-morbidities, and more disability based on the Modified Rankin Scale. Compared to non-frail patients after adjustment, frail patients were at higher risk of in-hospital major complication (OR 1.29, 95% 1.02-1.62, p = 0.01), any complication (OR 1.29, 95% CI 1.09-1.52, p = 0.0005), and death (OR 5.79, 95% CI 1.75-19.17, p = 0.001), while no difference was observed in pre-frail patients. At 45-day follow-up, there was no difference in the risk of complications in frail patients as compared to non-frail, although mortality was significantly higher (OR 3.01, 95% CI 1.97-4.85, p < 0.0001). CONCLUSION: A simple and practical frailty scale accurately predicts adverse events in patients undergoing LAAO. The 13% of patients considered frail were at significantly higher risk of in-hospital adverse events and 45-day mortality.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Fragilidade , Acidente Vascular Cerebral , Humanos , Masculino , Feminino , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fragilidade/epidemiologia , Fragilidade/complicações , Estudos Retrospectivos , Sistema de Registros , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento
5.
Artigo em Inglês | MEDLINE | ID: mdl-37882994

RESUMO

BACKGROUND: Over 100,000 Abbott Riata® were implanted in the United States before they were recalled in 2010. There are still a significant number of Abbott Riata® leads in use, and it is unclear how these leads should be managed at the time of generator change or lead malfunction. Although data comparing both Sprint Fidelis® and Abbott Riata® leads in this setting is available, there are no multicenter comparative studies of outcomes for various lead management strategies, including lead extraction (LE), lead abandonment/revision (LA), and generator change (GC) only at the time of device at elective replacement interval (ERI) for Abbott Riata® leads. METHODS: A retrospective, multicenter study was undertaken to compare short-term outcomes (major complications-MC, death, extended or re-hospitalizations within 60 days-RH, lead malfunction-LM) and total outcomes (short-term outcomes & lead malfunction during follow-up) of patients with Riata® leads undergoing LE, LA, or GC. RESULTS: 152 patients (65 ± 13 years, 68% male) were followed for a mean 33 ± 30 months following intervention. Out of 166 procedures, 13 patients underwent LE, 16 patients underwent LA, and 137 patients underwent GC. There was 1 major complication in each group, yielding an event rate of 7.7% for LE, 6.3% for LA, and 0.7% for GC cohorts. There were significantly more short-term and total adverse outcomes in the group of patients getting LE and LA versus GC only (38.5% & 31.3% vs 7.3%, P < 0.001). Total Riata® lead dwell time follow-up was 17,067 months. A total of 3 Riata® lead malfunctions were noted during long-term follow-up. Inappropriate shocks were similar between LE 7.7% (1/13), LA 6.3% (1/16). and GC 11.0% (4/136); P = 0.57. CONCLUSIONS: There were more short-term and total adverse outcomes in more invasive management strategies (LE and LA) versus GC alone. The failure rate of Riata® leads was substantially lower compared to previous reports. Therefore, we recommend only performing battery exchange when a device with an active Riata® lead is at ERI, unless there is malfunction of the Riata® lead noted on testing. There were significantly more short-term adverse outcomes in the lead extraction (5/13) and lead abandonment/revision (5/16) groups than the generator only (8/137) group (P < 0.001). GIB - Gastrointestinal bleed, CHF - congestive heart failure, NSTEMI - non-ST elevation MI.

7.
J Am Coll Cardiol ; 82(8): 735-747, 2023 08 22.
Artigo em Inglês | MEDLINE | ID: mdl-37587585

RESUMO

Nonischemic cardiomyopathy (NICM) is common and patients are at significant risk for early mortality secondary to ventricular arrhythmias. Current guidelines recommend implantable cardioverter-defibrillator (ICD) therapy to decrease sudden cardiac death (SCD) in patients with heart failure and reduced left ventricular ejection fraction. However, in randomized clinical trials comprised solely of patients with NICM, primary prevention ICDs did not confer significant mortality benefit. Moreover, left ventricular ejection fraction has limited sensitivity and specificity for predicting SCD. Therefore, precise risk stratification algorithms are needed to define those at the highest risk of SCD. This review examines mechanisms of sudden arrhythmic death in patients with NICM, discusses the role of ICD therapy and treatment of heart failure for prevention of SCD in patients with NICM, examines the role of cardiac magnetic resonance imaging and computational modeling for SCD risk stratification, and proposes new strategies to guide future clinical trials on SCD risk assessment in patients with NICM.


Assuntos
Cardiomiopatias , Insuficiência Cardíaca , Humanos , Volume Sistólico , Função Ventricular Esquerda , Cardiomiopatias/complicações , Cardiomiopatias/terapia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle
8.
Artigo em Inglês | MEDLINE | ID: mdl-37556090

RESUMO

BACKGROUND: Real-world data have suggested inconsistent adherence to oral anticoagulation for thromboembolic event (TE) prevention in patients with Non valvular atrial fibrillation (NVAF), yet it remains unclear if event risk is elevated during gaps of non-adherence. OBJECTIVE: To compare difference in outcomes between direct oral anticoagulant (DOAC) and warfarin based on adherence to the therapy in patients with NVAF. METHODS: Using the MarketScan claims data, patients receiving prescription of warfarin or a DOAC for NVAF from January 2015 to June 2016 were included. Outcomes included hospitalization for TE (ischemic stroke or systemic embolism), hemorrhagic stroke, stroke of any kind, and major bleeding. Event rates were reported for warfarin and DOACs at a higher-adherence proportion of days covered (PDC > 80%) and lower-adherence (PDC 40-80%). RESULTS: The cohort included 83,168 patients prescribed warfarin (51% [n = 42,639]) or DOAC (49% [n = 40,529]). Lower adherence occurred in 36% (n = 15,330) of patients prescribed warfarin and 26% (n = 10,956) prescribed DOAC. As compared to higher-adherence warfarin after multivariable adjustment, the risk of TE was highest in lower-adherence DOAC (HR 1.26; 95% CI, 1.14-1.33), and lowest in higher-adherence DOAC (HR, 0.93; 95% CI, 0.88-0.99). There was a significantly higher risk of hemorrhagic stroke and stroke of any kind in the lower-adherence groups. Major bleeding was more common with lower-adherence DOAC (HR, 1.43, 95% CI, 1.35-1.52) and lower-adherence warfarin (HR, 1.32, 95% CI, 1.26-1.39). CONCLUSIONS: In this large real-world study, low adherence DOAC was associated with higher risk of TE events as compared to high and low adherence warfarin.

9.
Curr Cardiol Rep ; 25(9): 909-915, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37584874

RESUMO

PURPOSE OF REVIEW: Left atrial appendage closure (LAAC) has shown to be non-inferior to oral anticoagulation (OAC) for non-valvular atrial fibrillation (AF). LAAC is now becoming a leading method for stroke prophylaxis in patients who have atrial fibrillation and are unable to tolerate OAC. There are currently two FDA-approved endocardial closure devices, namely, the Watchman FLX and Amplatzer Amulet. RECENT FINDINGS: Current data highlights that both devices offer similar efficacy and safety for LAAC. While the two devices differ in terms of intraprocedural complication rates, they offer similar short- to long-term outcomes in regard to peri-device leaks, device-related thrombosis, and mortality. With similar risk and safety profiles, both devices are indicated for patients who are unable to tolerate OAC. Newer clinical studies are directed to establish the efficacy of both devices as the primary method for stroke prevention in AF as an alternate to OAC.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Procedimentos Cirúrgicos Cardíacos , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Fibrilação Atrial/tratamento farmacológico , Apêndice Atrial/cirurgia , Resultado do Tratamento , Procedimentos Cirúrgicos Cardíacos/métodos , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/tratamento farmacológico , Anticoagulantes/uso terapêutico
10.
Heart Rhythm O2 ; 4(6): 374-381, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37361614

RESUMO

Background: Remote monitoring (RM) has been accepted as a standard of care for follow-up of patients with cardiac implantable electronic devices (CIEDs). However, the resulting data deluge poses major challenge to device clinics. Objective: This study aimed to quantify the data deluge from CIED and stratify these data based on clinical relevance. Methods: The study included patients from 67 device clinics across the United States being remotely monitored by Octagos Health. The CIEDs included implantable loop recorders, pacemakers, implantable cardioverter-defibrillators, cardiac resynchronization therapy defibrillators, and cardiac resynchronization therapy pacemakers. Transmissions were either dismissed before reaching the clinical practice if they were repetitive or redundant or were forwarded if they were either clinically relevant or actionable transmission (alert). The alerts were further classified as level 1, 2, or 3 based on clinical urgency. Results: A total of 32,721 patients with CIEDs were included. There were 14,465 (44.2%) patients with pacemakers, 8381 (25.6%) with implantable loop recorders, 5351 (16.4%) with implantable cardioverter-defibrillators, 3531 (10.8%) with cardiac resynchronization therapy defibrillators, and 993 (3%) with cardiac resynchronization therapy pacemakers. Over a period of 2 years of RM, 384,796 transmissions were received. Of these, 220,049 (57%) transmissions were dismissed, as they were either redundant or repetitive. Only 164,747 (43%) transmissions were transmitted to the clinicians, of which only 13% (n = 50,440) had clinical alerts, while 30.6% (n = 114,307) were routine transmissions. Conclusion: Our study shows that data deluge from RM of CIEDs can be streamlined by utilization of appropriate screening strategies that will enhance efficiency of device clinics and provide better patient care.

11.
Am J Cardiol ; 201: 193-199, 2023 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-37385174

RESUMO

Surgical left atrial appendage (LAA) occlusion with an AtriClip (AtriCure, West Chester, Ohio) is frequently performed for stroke prophylaxis in patients with atrial fibrillation (AF). We conducted a retrospective analysis of all patients with long-standing persistent AF who underwent hybrid convergent ablation and LAA clipping. Contrast-enhanced cardiac computed tomography was performed at 3 to 6 months after LAA clipping to assess the degree of complete closure and the residual LAA stump. A total of 78 patients (64 ± 10 years, 72% male) underwent LAA clipping as part of hybrid convergent AF ablation, from 2019 to 2020. Median size of AtriClip used was 45 mm. Mean LA size was 4.6 ± 1 cm. At 3-to-6 months follow-up computed tomography, 46.2% of patients (n = 36) had a residual stump proximal to the deployed LAA clip. Mean depth of residual stump was 3.95 ± 5.5 mm, with 19% of patients (n = 15) having a stump depth of ≥10 mm and 1 patient requiring more endocardial LAA closure owing to large stump depth. During 1-year follow-up, 3 patients developed stroke; device leak of 6 mm was noted in 1 patient; and none of the patients had a thrombus proximal to the clip. In conclusion, high incidence of residual LAA stump was observed with AtriClip. Larger studies with long-term follow-up are needed to better assess the thromboembolic implications of a residual stump after AtriClip placement.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Procedimentos Cirúrgicos Cardíacos , Acidente Vascular Cerebral , Humanos , Masculino , Feminino , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Procedimentos Cirúrgicos Cardíacos/métodos , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Ecocardiografia Transesofagiana/efeitos adversos
13.
J Am Coll Cardiol ; 81(22): 2189-2206, 2023 06 06.
Artigo em Inglês | MEDLINE | ID: mdl-37257955

RESUMO

Electrical storm (ES) reflects life-threatening cardiac electrical instability with 3 or more ventricular arrhythmia episodes within 24 hours. Identification of underlying arrhythmogenic cardiac substrate and reversible triggers is essential, as is interrogation and programming of an implantable cardioverter-defibrillator, if present. Medical management includes antiarrhythmic drugs, beta-adrenergic blockade, sedation, and hemodynamic support. The initial intensity of these interventions should be matched to the severity of ES using a stepped-care algorithm involving escalating treatments for higher-risk presentations or recurrent ventricular arrhythmias. Many patients with ES are considered for catheter ablation, which may require the use of temporary mechanical circulatory support. Outcomes after ES are poor, including frequent ES recurrences and deaths caused by progressive heart failure and other cardiac causes. A multidisciplinary collaborative approach to the management of ES is crucial, and evaluation for heart transplantation or palliative care is often appropriate, even for patients who survive the initial episode.


Assuntos
Ablação por Cateter , Desfibriladores Implantáveis , Transplante de Coração , Taquicardia Ventricular , Humanos , Arritmias Cardíacas , Antiarrítmicos/uso terapêutico , Taquicardia Ventricular/terapia
14.
JACC Clin Electrophysiol ; 9(4): 555-564, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-37014289

RESUMO

BACKGROUND: Inpatient initiation of sotalol is recommended owing to its proarrhythmic effects. OBJECTIVES: The DASH-AF (Feasibility and Safety of Intravenous Sotalol Administered as a Loading Dose to Initiate Oral Sotalol Therapy in Adult Patients With Atrial Fibrillation) trial evaluates the safety and feasibility of intravenous (IV) sotalol, achieving a steady state with maximum QTc prolongation within 6 hours instead of the traditional 5-dose inpatient oral (PO) titration. METHODS: DASH-AF is a prospective, nonrandomized, multicenter, open-label trial consisting of patients who underwent IV sotalol loading dose to initiate rapid oral therapy for atrial arrhythmias. IV dose was calculated based on the target oral dose as indicated by baseline QTc and renal function. Patients' QTc (in sinus) was measured via electrocardiography at 15-minute intervals and after IV loading completion. Patients were discharged 4 hours after first oral dose. All patients were monitored via mobile cardiac outpatient telemetry for 72 hours. The control group was composed of patients admitted for the traditional 5 PO doses. Safety outcomes were assessed in both groups. RESULTS: A total of 120 patients from 3 centers were enrolled from 2021 to 2022 in the IV loading group (compared with type of AF- and renal function-matched patients in the conventional PO loading cohort). This study demonstrated no significant change in ΔQTc in both groups, with a significantly lower number of patients requiring dose adjustment in the IV arm compared with the PO arm (4.1% vs 16.6%; P = 0.003). This led to potential cost savings of up to $3,500.68 per admission. CONCLUSIONS: The DASH-AF trial shows that rapid IV sotalol loading in atrial fibrillation/flutter patients for rhythm control is feasible and safe compared with conventional oral loading with significant cost reduction. (Feasibility and Safety of Intravenous Sotalol Administered as a Loading Dose to Initiate Oral Sotalol Therapy in Adult Patients With Atrial Fibrillation [DASH-AF]; NCT04473807).


Assuntos
Fibrilação Atrial , Sotalol , Humanos , Adulto , Sotalol/efeitos adversos , Antiarrítmicos/efeitos adversos , Estudos Prospectivos , Estudos de Viabilidade
16.
Artigo em Inglês | MEDLINE | ID: mdl-36598717

RESUMO

BACKGROUND: Percutaneous pericardial access is the cornerstone of various procedures in clinical cardiology. The two commonly used methods utilizing large bore (LB) and smaller micropuncture (MP) needles often lead to inadvertent RV punctures. As both of these techniques push the pericardium inward, the novel blunt tip concealed needle device (BTCND) introduces the concept of bringing a small portion of the pericardium into a tube, where needle puncture and guidewire can be passed into the pericardial space all within the safety of the tube. METHODS: The BTCND (Via One®, CardioVia, Nazareth, Israel) is a tool designed to allow for safe percutaneous subxiphoid pericardial access. In this preclinical study, a total of 18 procedures were performed in 5 female pigs. All procedures were performed under general anesthesia and under fluoroscopic guidance with a team of veterinarians and cardiac electrophysiologists. A laparoscopic camera was used to demonstrate and record the procedure. The Institutional Animal Care and Use Committees approved all preclinical experiments. RESULTS: A total of 18 procedures were performed on five female pigs. In all procedures, the physicians safely introduced guidewire into the pericardial space. Device operation was not associated with any adverse events or bleeding, nor was any damage seen to the pericardium, the heart, or other organs during the procedure. CONCLUSION: The result of our preclinical report demonstrates that the device is intuitive, easy to use, and effective for its intended use. Large preclinical studies are needed to validate the results of the study.

17.
JACC Clin Electrophysiol ; 8(11): 1458-1459, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36424017
18.
Cardiovasc Digit Health J ; 3(6): 263-275, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36589314

RESUMO

Artificial intelligence (AI) and machine learning (ML) have significantly impacted the field of cardiovascular medicine, especially cardiac electrophysiology (EP), on multiple fronts. The goal of this review is to familiarize readers with the field of AI and ML and their emerging role in EP. The current review is divided into 3 sections. In the first section, we discuss the definitions and basics of AI, ML, and big data. In the second section, we discuss their application to EP in the context of detection, prediction, and management of arrhythmias. Finally, we discuss the regulatory issues, challenges, and future directions of AI in EP.

19.
Curr Cardiol Rev ; 18(2): e040821195265, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34348632

RESUMO

Implantable Cardioverter-Defibrillator (ICD) therapy is indicated for patients at risk for sudden cardiac death due to ventricular tachyarrhythmia. The most commonly used risk stratification algorithms use Left Ventricular Ejection Fraction (LVEF) to determine which patients qualify for ICD therapy, even though LVEF is a better marker of total mortality than ventricular tachyarrhythmias mortality. This review evaluates imaging tools and novel biomarkers proposed for better risk stratifying arrhythmic substrate, thereby identifying optimal ICD therapy candidates.


Assuntos
Cardiomiopatia Dilatada , Desfibriladores Implantáveis , Taquicardia Ventricular , Cardiomiopatia Dilatada/complicações , Cardiomiopatia Dilatada/terapia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Humanos , Medição de Risco/métodos , Fatores de Risco , Volume Sistólico , Taquicardia Ventricular/complicações , Taquicardia Ventricular/terapia , Função Ventricular Esquerda
20.
Artigo em Inglês | MEDLINE | ID: mdl-34690486

RESUMO

PURPOSE OF REVIEW: The COVID-19 pandemic has significantly impacted the delivery of education for all specialties, including cardiac electrophysiology. This review will provide an overview of the COVID-19 spurred digital transformation of electrophysiology education for practicing clinicians and trainees in electrophysiology and cover the use of social media in these educational efforts. RECENT FINDINGS: Major international, national, and local meetings and electrophysiology fellowship-specific educational sessions have transitioned rapidly to virtual and distanced learning, enhanced by social media. This has allowed for participation in educational activities by electrophysiologists on a wider, more global scale. Social media has also allowed rapid dissemination of new advances, techniques, and research findings in real time and to a global audience, but caution must be exercised as pitfalls also exist. SUMMARY: The digital and social media transformation of cardiac electrophysiology education has arrived and revolutionized the way education is delivered and consumed. Continued hybrid in-person and virtual modalities will provide electrophysiologists the flexibility to choose the best option to suit their individual needs and preferences for continuing education.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...