Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
1.
Europace ; 19(4): 651-659, 2017 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-28431061

RESUMO

AIMS: Mutations in PRKAG2, the gene encoding for the γ2 subunit of 5'-AMP-activated protein kinase (AMPK), are responsible for an autosomal dominant glycogenosis with a cardiac presentation, associating hypertrophic cardiomyopathy (HCM), ventricular pre-excitation (VPE), and progressive heart block. The aim of this study was to perform a retrospective time-to-event study of the clinical manifestations associated with PRKAG2 mutations. METHODS AND RESULTS: A cohort of 34 patients from 9 families was recruited between 2001 and 2010. DNA were sequenced on all exons and flanking sequences of the PRKAG2 gene using Sanger sequencing. Overall, four families carried the recurrent p.Arg302Gln mutation, and the five others carried private mutations among which three had never been reported. In the total cohort, at 40 years of age, the risk of developing HCM was 61%, VPE 70%, conduction block 22%, and sudden cardiac death (SCD) 20%. The global survival at 60 years of age was 66%. Thirty-two per cent of patients (N = 10) required a device implantation (5 pacemakers and 5 defibrillators) at a median age of 66 years, and two patients required heart transplant. Only one patient presented with significant skeletal muscle symptoms. No significant differences regarding the occurrence of VPE, ablation complications, or death incidence were observed between different mutations. CONCLUSION: This study of patients with PRKAG2 mutations provides a more comprehensive view of the natural history of this disease and demonstrates a high risk of cardiac complications. Early recognition of this disease appears important to allow an appropriate management.


Assuntos
Proteínas Quinases Ativadas por AMP/genética , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/genética , Cardiomiopatia Hipertrófica/genética , Cardiomiopatia Hipertrófica/mortalidade , Doença de Depósito de Glicogênio/genética , Doença de Depósito de Glicogênio/mortalidade , Adulto , Comorbidade , Feminino , França/epidemiologia , Marcadores Genéticos/genética , Predisposição Genética para Doença/epidemiologia , Predisposição Genética para Doença/genética , Humanos , Masculino , Pessoa de Meia-Idade , Mutação/genética , Polimorfismo de Nucleotídeo Único/genética , Prevalência , Fatores de Risco , Taxa de Sobrevida
2.
Eur Heart J ; 38(22): 1749-1755, 2017 06 07.
Artigo em Inglês | MEDLINE | ID: mdl-29688304

RESUMO

Aims: Remote monitoring of implantable cardioverter-defibrillators may improve clinical outcome. A recent meta-analysis of three randomized controlled trials (TRUST, ECOST, IN-TIME) using a specific remote monitoring system with daily transmissions [Biotronik Home Monitoring (HM)] demonstrated improved survival. We performed a patient-level analysis to verify this result with appropriate time-to-event statistics and to investigate further clinical endpoints. Methods and results: Individual data of the TRUST, ECOST, and IN-TIME patients were pooled to calculate absolute risks of endpoints at 1-year follow-up for HM vs. conventional follow-up. All-cause mortality analysis involved all three trials (2405 patients). Other endpoints involved two trials, ECOST and IN-TIME (1078 patients), in which an independent blinded endpoint committee adjudicated the underlying causes of hospitalizations and deaths. The absolute risk of death at 1 year was reduced by 1.9% in the HM group (95% CI: 0.1-3.8%; P = 0.037), equivalent to a risk ratio of 0.62. Also the combined endpoint of all-cause mortality or hospitalization for worsening heart failure (WHF) was significantly reduced (by 5.6%; P = 0.007; risk ratio 0.64). The composite endpoint of all-cause mortality or cardiovascular (CV) hospitalization tended to be reduced by a similar degree (4.1%; P = 0.13; risk ratio 0.85) but without statistical significance. Conclusion: In a pooled analysis of the three trials, HM reduced all-cause mortality and the composite endpoint of all-cause mortality or WHF hospitalization. The similar magnitudes of absolute risk reductions for WHF and CV endpoints suggest that the benefit of HM is driven by the prevention of heart failure exacerbation.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca/prevenção & controle , Adulto , Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/prevenção & controle , Feminino , Insuficiência Cardíaca/mortalidade , Humanos , Masculino , Monitorização Ambulatorial/métodos , Estudos Multicêntricos como Assunto , Ensaios Clínicos Controlados Aleatórios como Assunto , Resultado do Tratamento
3.
Arch Cardiovasc Dis ; 109(10): 517-526, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27342808

RESUMO

BACKGROUND: Little is known about the long-term outcomes of patients who receive an implantable cardioverter-defibrillator (ICD) for purely secondary prevention indications. AIMS: To assess the rates and predictors of appropriate therapies over a very long-term follow-up period in this population. METHODS: Between June 2003 and August 2006, 239 consecutive patients with structural left ventricular disease and a secondary prophylaxis indication for ICD therapy (survivors of life-threatening ventricular tachyarrhythmias) were prospectively enrolled. An extended follow-up of these patients was carried out. The primary endpoint was the occurrence of appropriate device therapy. Secondary endpoints were all-cause death, electrical storm and inappropriate therapy. RESULTS: The study population consisted of 239 patients (90% men; mean age 64±12 years; 72% ischaemic cardiomyopathy; left ventricular ejection fraction 37±12%). During a median follow-up of 7.8 (3.5-9.3) years, appropriate device therapy occurred in 139 (58.2%) patients. Death occurred in 141 patients (59%), electrical storm in 73 (30.5%) and inappropriate therapy in 42 (17.6%). Multivariable analysis identified patients whose presenting arrhythmia was ventricular fibrillation as being less likely to require appropriate device therapy than those whose presenting arrhythmia was ventricular tachycardia (sub-hazard ratio 0.62, 95% confidence interval 0.40-0.97; P=0.04). Independent predictors of all-cause death were age at implantation (P<0.0001), wide QRS complexes (P=0.024), creatinine concentration (P=0.0002) and B-type natriuretic peptide at implantation (P=0.0001). CONCLUSION: Secondary prevention ICD recipients exhibit a high risk of appropriate device therapy and death over prolonged follow-up. Patients who presented initially with ventricular fibrillation were less likely to require the delivery of appropriate device therapy.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Prevenção Secundária/métodos , Taquicardia Ventricular/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Morte Súbita Cardíaca/etiologia , Eletrocardiografia , Feminino , Seguimentos , França/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida/tendências , Taquicardia Ventricular/mortalidade , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo , Adulto Jovem
4.
Europace ; 18(6): 820-7, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26498163

RESUMO

AIMS: Lead fractures in implantable cardioverter-defibrillator (ICD) patients may cause inappropriate shocks (ISs). An early diagnosis is essential to prevent adverse clinical events. Implantable cardioverter-defibrillator remote monitoring (RM) permits prompt detection of lead fracture. Limited data define the impact of RM on ISs specifically related to lead fracture. We sought to compare the number of ISs related to lead fracture in patients with vs. without RM follow-up. METHODS AND RESULTS: We checked the registry of our institution and collected, between July 2007 and June 2014, 115 cases of right ventricular lead fractures. All relevant data were documented from patients' files, device-interrogation printouts and electronic records, and remote transmissions databases when applicable. We assessed the ISs that were related to lead fracture. The first study endpoint was the number of ISs per shocked patient. Among the 82 patients with conventional follow-up (CFU) and the 33 patients with RM, a first IS occurred to 32.9% (n = 27) and 30.3% (n = 10, P = 0.83) of the patients, respectively. Shocked patients in the RM group underwent significantly fewer ISs with a mean of 6 ± 2 shocks per patient [median of 3.5 shocks (2-8)] than those in the CFU group with a mean of 18 ± 5 shocks per patient [median of 10 shocks (5-22), P = 0.03]. CONCLUSION: Remote monitoring helps to reduce the burden of ISs related to ICD lead fractures.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica/efeitos adversos , Falha de Equipamento , Tecnologia de Sensoriamento Remoto , Feminino , Seguimentos , França , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros
5.
Europace ; 18(12): 1809-1817, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26711741

RESUMO

AIMS: Despite increased use of remote monitoring (RM) to follow up implantable cardioverter-defibrillator (ICD) recipients, many patients still receive ICD shocks in the community and present to the emergency department. Our aim was to identify the best predictors of impending shock delivery that can be measured with an ICD and to identify the most appropriate activities to alert physicians to during RM follow-up. METHODS AND RESULTS: All patients presenting to our institution for ICD shock, from November 2011 to November 2014, were enrolled in this prospective study. Patient characteristics, investigation results, and details of electrical activities from ICD interrogation were recorded at presentation. Presentations were classified as potentially avoidable if activities from a list of set criteria were apparent more than 48 h before index shock. Univariate and multivariate analyses were then used to identify predictors of potentially avoidable shocks. In total, 109 emergency presentations were recorded in 90 patients (male: 85%; 57 ± 16 years; ischaemic cardiomyopathy: 49%; LVEF: 34 ± 13%; electrical storm: 40%), of which 26 (24%) were potentially avoidable. Antitachycardia pacing (ATP) episodes were the most important predictor of impending shock. Potentially avoidable shocks were preceded by more episodes of ATP than unavoidable shocks (13 [3-67] vs. 3 [0-10]; P < 0.001). Patients followed up with RM systems configured to generate alerts following ATP delivery experienced significantly less ICD shocks (24 vs. 16%, P < 0.01). CONCLUSION: Remote monitoring systems that generate alerts following ATP delivery could reduce emergency presentations for ICD shock by 24%, as ATP is a key predictor of impending shock delivery.


Assuntos
Estimulação Cardíaca Artificial/efeitos adversos , Desfibriladores Implantáveis , Cardioversão Elétrica/efeitos adversos , Tecnologia de Sensoriamento Remoto , Taquicardia Ventricular/terapia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Cardioversão Elétrica/instrumentação , Eletrocardiografia , Serviços Médicos de Emergência , Feminino , França , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/métodos , Análise Multivariada , Isquemia Miocárdica/epidemiologia , Isquemia Miocárdica/etiologia , Estudos Prospectivos , Telemedicina , Disfunção Ventricular Esquerda/epidemiologia , Disfunção Ventricular Esquerda/etiologia , Adulto Jovem
6.
Circ Cardiovasc Qual Outcomes ; 8(4): 403-12, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26105725

RESUMO

BACKGROUND: Implantable cardioverter-defibrillators (ICDs) are a standard means of sudden cardiac death prevention. Compared with ambulatory visits, remote monitoring (RM) of ICD recipients has improved the quality of health care and spared its resources. Few studies have addressed the organization of RM. We optimized and validated our institutional model of RM organization for ICD recipients. METHODS AND RESULTS: This observational study of 562 ICD recipients compared 2 RM periods consisting of iterative, qualitative, and quantitative (1) device diagnostic evaluations by nurses and cardiologists; and (2) selected decisional trees. The main study end points were the professional interventions prompted by, and times allocated to, RM alerts. During the first period, 1134 alerts occurred in 427 patients (286 patient-year), of which 376 (33%) were submitted to cardiologists' reviews, compared with, 1522 alerts in 562 patients (458 patient-year), of which 273 (18%) were submitted to cardiologists' reviews during the second period (P<0.001). An intervention was prompted by 73 of 376 (19.4%) alerts in the first versus 77 of 273 (28.2%) in the second period (P=0.009). The mean time to manage an alert was 4 minutes 31 s in the first versus 2 minutes 10 s in the second period (P<0.001). The annual numbers of alert-related hospitalizations were 10.8 versus 8.1 per 100-patient-year (P=0.230), and annual numbers of alert-related visits were 9.8 and 6.1 per 100-patient-year (P=0.081), respectively. CONCLUSIONS: An optimized RM organization based on automated alerts and decisional trees enabled a focus on clinically relevant events and a decrease in the consumption of resources without compromising the quality of ICD recipients' care.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Gerenciamento Clínico , Insuficiência Cardíaca/terapia , Modelos Organizacionais , Monitorização Fisiológica/métodos , Telemedicina/métodos , Feminino , Seguimentos , Insuficiência Cardíaca/fisiopatologia , Hospitalização/tendências , Humanos , Masculino , Pessoa de Meia-Idade , Qualidade de Vida , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Tempo
7.
Arch Cardiovasc Dis ; 107(12): 664-71, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25241223

RESUMO

BACKGROUND: Remote monitoring (RM) is increasingly used to follow up patients with implantable cardioverter-defibrillators (ICDs). Randomized control trials provide evidence for the benefit of this intervention, but data for RM in daily clinical practice with multiple-brands and unselected patients is lacking. AIMS: To assess the effect of RM on patient management and clinical outcome for recipients of ICDs in daily practice. METHODS: We reviewed ICD recipients followed up at our institution in 2009 with RM or with traditional hospital only (HO) follow-up. We looked at the effect of RM on the number of scheduled ambulatory follow-ups and urgent unscheduled consultations, the time between onset of asymptomatic events to clinical intervention and the clinical effectiveness of all consultations. We also evaluated the proportion of RM notifications representing clinically relevant situations. RESULTS: We included 355 patients retrospectively (RM: n=144, HO: n=211, 76.9% male, 60.3±15.2 years old, 50.1% with ICDs for primary prevention and mean left ventricular ejection fraction 35.5±14.5%). Average follow-up was 13.5 months. The RM group required less scheduled ambulatory follow-up consultations (1.8 vs. 2.1/patient/year; P<0.0001) and a far lower median time between the onset of asymptomatic events and clinical intervention (7 vs. 76 days; P=0.016). Of the 784 scheduled ambulatory follow-up consultations carried out, only 152 (19.4%) resulted in therapeutic intervention or ICD reprogramming. We also found that the vast majority of RM notifications (61.9%) were of no clinical relevance. CONCLUSION: RM allows early management of asymptomatic events and a reduction in scheduled ambulatory follow-up consultations in daily clinical practice, without compromising safety, endorsing RM as the new standard of care for ICD recipients.


Assuntos
Arritmias Cardíacas/terapia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Prevenção Primária/instrumentação , Ensaios Clínicos Controlados Aleatórios como Assunto , Telemedicina/métodos , Telemetria , Adulto , Idoso , Assistência Ambulatorial , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/fisiopatologia , Medicina Baseada em Evidências , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Encaminhamento e Consulta , Estudos Retrospectivos , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda
8.
Can J Cardiol ; 30(6): 606-11, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24882530

RESUMO

BACKGROUND: For patients presenting with syncope and bundle branch block (BBB), results during electrophysiological studies (EPS) might depend on the electrocardiographic pattern of conduction disturbances. We sought to identify predictors of advanced His-Purkinje conduction disturbances (HPCDs) in these patients. METHODS: In this retrospective multicentre study, patients were included who: (1) presented with unexplained syncope; (2) had BBB (QRS duration ≥ 120 ms); and (3) were investigated with EPS. HPCD was diagnosed if the baseline His-ventricular interval was ≥ 70 ms or if second- or third-degree His-Purkinje block was observed during atrial pacing or pharmacological challenge. RESULTS: Of the 171 patients studied (72 ± 13 years, 64% male sex, mean left ventricular ejection fraction 57 ± 9%), advanced HPCD was found in 73 patients (43%). The following electrocardiographic features were associated with HPCD (P = 0.01): isolated right BBB (34.4%), right BBB with left anterior fascicular block (36.4%), left BBB (46.2%), and right BBB with left posterior fascicular block (LPFB, 78.6%). Multivariate analysis identified first-degree atrioventricular block (odds ratio, 2.4; 95% confidence interval, 1.2-4.7; P = 0.01) and LPFB (odds ratio, 4.8; 95% confidence interval, 1.3-18.5; P = 0.02) as the only 2 independent predictors of advanced HPCD. CONCLUSIONS: For patients presenting with syncope and BBB, first-degree atrioventricular block and LPFB increased the likelihood of finding HPCDs during EPS. However, no single electrocardiographic feature could consistently predict the outcome of EPS, so this investigation is still necessary in assessing the need for pacemaker implantation, irrespective of the precise appearance of abnormalities on ECG.


Assuntos
Fascículo Atrioventricular/fisiopatologia , Bloqueio de Ramo/fisiopatologia , Técnicas Eletrofisiológicas Cardíacas , Ramos Subendocárdicos/fisiopatologia , Síncope/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Bloqueio Atrioventricular/classificação , Bloqueio Atrioventricular/fisiopatologia , Bloqueio Atrioventricular/cirurgia , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/cirurgia , Desfibriladores Implantáveis , Eletrocardiografia , Feminino , Humanos , Masculino , Análise Multivariada , Marca-Passo Artificial , Estudos Retrospectivos , Volume Sistólico/fisiologia
9.
Europace ; 16(8): 1181-8, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24614572

RESUMO

AIMS: The Effectiveness and Cost of ICD follow-up Schedule with Telecardiology (ECOST) trial evaluated prospectively the economic impact of long-term remote monitoring (RM) of implantable cardioverter defibrillators (ICDs). METHODS AND RESULTS: The analysis included 310 patients randomly assigned to RM (active group) vs. ambulatory follow-ups (control group). Patients in the active group were seen once a year unless the system reported an event mandating an ambulatory visit, while patients in the control group were seen in the ambulatory department every 6 months. The costs of each follow-up strategy were compared, using the actual billing documents issued by the French health insurance system, including costs of (i) (a) ICD-related ambulatory visits and transportation, (b) other ambulatory visits, (c) cardiovascular treatments and procedures, and (ii) hospitalizations for the management of cardiovascular events. The ICD and RM system costs were calculated on the basis of the device remaining longevity at the end of the study. The characteristics of the study groups were similar. Over a follow-up of 27 months, the mean non-hospital costs per patient-year were €1695 ± 1131 in the active, vs. €1952 ± 1023 in the control group (P = 0.04), a €257 difference mainly due to device management. The hospitalization costs per patient-year were €2829 ± 6382 and €3549 ± 9714 in the active and control groups, respectively (P = 0.46). Adding the ICD to the non-hospital costs, the savings were €494 (P = 0.005) or, when the monitoring system was included, €315 (P = 0.05) per patient-year. CONCLUSION: From the French health insurance perspective, the remote management of ICD patients is cost saving. CLINICAL TRIALS REGISTRATION: NCT00989417, www.clinicaltrials.gov.


Assuntos
Assistência Ambulatorial/economia , Desfibriladores Implantáveis/economia , Cardioversão Elétrica/economia , Custos de Cuidados de Saúde , Telemedicina/economia , Telemetria/economia , Idoso , Redução de Custos , Análise Custo-Benefício , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/instrumentação , Feminino , França , Gastos em Saúde , Custos Hospitalares , Humanos , Reembolso de Seguro de Saúde , Masculino , Pessoa de Meia-Idade , Visita a Consultório Médico/economia , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Fatores de Tempo , Transporte de Pacientes/economia , Resultado do Tratamento
10.
Europace ; 16(11): 1587-94, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24596396

RESUMO

AIMS: To describe obstetric/neonatal and cardiac outcomes for a cohort of women carrying implantable cardioverter-defibrillators (ICDs) during pregnancy. METHODS AND RESULTS: All women in routine follow-up at our institution for ICD implantation who became pregnant between 2006 and 2013 were included in this study. All ICDs were pre-pectoral devices with bipolar endocardial leads. Obstetric/neonatal and cardiac outcomes were assessed during pregnancy and post-partum. Twenty pregnancies were conceived by 12 women carrying ICD devices, 14 of which resulted in live births and none in maternal death. Seven of these women had structural cardiomyopathies and five had channelopathies. No device-related complications were recorded. Twelve shocks (nine transthoracic and three from ICDs) were experienced during pregnancy by two women, one of whom miscarried shortly afterwards at 4 weeks gestation. One stillbirth, three miscarriages and one termination were recorded for women with long QT syndrome, repaired tetralogy of Fallot and repaired Laubry-Pezzi syndrome, respectively. Intrauterine growth restriction, low birth weight, and neonatal hypoglycaemia were recorded in four, three, and five pregnancies, respectively. CONCLUSIONS: Pregnancy had no effect on ICD operation and no evidence was found to link ICD carriage with adverse pregnancy outcomes, although one miscarriage may have been induced by ICD shock therapy. A worsening of cardiac condition occurs in specific cardiac diseases and ß-blocker therapy should be continued for all women carrying ICDs in pregnancy as the benefits outweigh the risks of taking this medication.


Assuntos
Cardiomiopatias/terapia , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Cardiopatias Congênitas/terapia , Complicações Cardiovasculares na Gravidez/terapia , Aborto Espontâneo/etiologia , Antagonistas Adrenérgicos beta/uso terapêutico , Adulto , Cardiomiopatias/congênito , Cardiomiopatias/diagnóstico , Cardiomiopatias/fisiopatologia , Progressão da Doença , Cardioversão Elétrica/efeitos adversos , Eletrocardiografia , Feminino , França , Idade Gestacional , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/fisiopatologia , Humanos , Nascido Vivo , Segurança do Paciente , Gravidez , Complicações Cardiovasculares na Gravidez/diagnóstico , Complicações Cardiovasculares na Gravidez/fisiopatologia , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
11.
J Cardiovasc Electrophysiol ; 25(7): 763-70, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24602062

RESUMO

INTRODUCTION: Inappropriate shocks remain a highly challenging complication of implantable cardioverter defibrillators (ICD). We examined whether automatic wireless remote monitoring (RM) of ICD, by providing early notifications of triggering events, lowers the incidence of inappropriate shocks. METHODS AND RESULTS: We studied 433 patients randomly assigned to RM (n = 221; active group) versus ambulatory follow-up (n = 212; control group). Patients in the active group were seen in the ambulatory department once a year, unless RM reported an event requiring an earlier ambulatory visit. Patients in the control group were seen in the ambulatory department every 6 months. The occurrence of first and further inappropriate shocks, and their causes in each group were compared. The characteristics of the study groups, including pharmaceutical regimens, were similar. Over a follow-up of 27 months, 5.0% of patients in the active group received ≥1 inappropriate shocks versus 10.4% in the control group (P = 0.03). A total of 28 inappropriate shocks were delivered in the active versus 283 in the control group. Shocks were triggered by supraventricular tachyarrhythmias (SVTA) in 48.5%, noise oversensing in 21.2%, T wave oversensing in 15.2%, and lead dysfunction in 15.2% of patients. The numbers of inappropriate shocks delivered per patient, triggered by SVTA and by lead dysfunction, were 74% and 98% lower, respectively, in the active than in the control group. CONCLUSION: RM was highly effective in the long-term prevention of inappropriate ICD shocks.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/instrumentação , Traumatismos por Eletricidade/prevenção & controle , Falha de Prótese , Tecnologia de Sensoriamento Remoto , Telemedicina/métodos , Idoso , Assistência Ambulatorial , Diagnóstico Precoce , Traumatismos por Eletricidade/diagnóstico , Traumatismos por Eletricidade/etiologia , Traumatismos por Eletricidade/fisiopatologia , Feminino , França , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
12.
J Interv Card Electrophysiol ; 40(1): 75-80, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24626999

RESUMO

INTRODUCTION: A quadripolar left ventricular (LV) pacing can deliver multipoint pacing (MPP). It is unknown if this confers improved cardiac function compared to conventional cardiac resynchronization therapy (CRT). METHODS AND RESULTS: We aimed to characterize changes in acute cardiac contractility and hemodynamics with multisite left ventricular "multipoint" pacing (MPP) in a prospective multicenter study in patients implanted with a CRT-defibrillator incorporating a quadripolar LV lead. The device was programmed to deliver MPP acutely pacing with eight configurations of varying timing delays. Global peak LV radial strain and LV outflow velocity time integral (LVOT VTI) were measured for conventional CRT and each MPP configuration. Out of the eight tested MPP configurations, the one that yielded the best echocardiographic measurement for each patient was defined as "optimal MPP". Forty CRT recipients had complete radial strain datasets suitable for analysis. Compared to conventional CRT, the mean peak radial strain was significantly higher for the optimal MPP configuration (18.3 ± 7.4 vs. 9.3 ± 5.3%, p < 0.001), and at least one MPP configuration was significantly superior (>20%) in 63% of patients. LVOT VTI data were collected in a subset of 13 patients. In these patients, mean VTI was significantly higher for optimal MPP compared to conventional CRT (13.5 ± 2.7 vs. 10.9 ± 3.3 cm, p < 0.01). CONCLUSION: MPP delivered via a quadripolar LV lead resulted in a significant improvement in acute cardiac contractility and hemodynamics compared to conventional CRT in the majority of patients studied. CLINICAL TRIAL REGISTRATION: Clinicaltrials.gov identifier NCT01044784.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Contração Miocárdica , Idoso , Eletrodos Implantados , Desenho de Equipamento , Feminino , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
13.
Eur Heart J ; 35(2): 116-22, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24258072

RESUMO

AIMS: Limited data are available on long-term prognosis or causes-of-death analysis among survivors of acute myocardial infarction (MI) according to whether or not they developed ventricular fibrillation (VF) during the acute stage of MI. METHODS AND RESULTS: Among 3670 MI patients hospitalized in France in 2005 and enrolled in this prospective follow-up cohort study, we assessed in-hospital mortality and 5-year cause of death among those who survived to hospital discharge, according to whether they developed VF (116 cases) or not, during the acute stage. 94.5% of patients had complete follow-up at 5 years. In-hospital mortality was significantly higher among VF patients (adjusted OR 7.38, 95% CI 4.27-12.75, P < 0.001). Among 3463 survivors at hospital discharge, 1024 died during a mean follow-up of 52 ± 2 months. The overall survival rate at 5 years was 74.4% (95% CI 72.8-76.0). In Cox multivariate analysis, occurrence of VF during the acute phase of MI was not associated with an increased mortality at 5 years (HR 0.78, 95% CI 0.38-1.58, P = 0.21). The distribution of causes of death at 5 years did not statistically differ according to the presence or absence of VF, especially for sudden cardiac death (13.1% in VF group vs.12.9% in non-VF group), despite a very low rate of implantation of cardioverter defibrillator in both groups (Overall rate 1.2%). CONCLUSION: Patients developing VF in the setting of acute MI are at higher risk of in-hospital mortality. However, VF is not associated with a higher long-term all-cause or sudden cardiac death mortality.


Assuntos
Morte Súbita Cardíaca/epidemiologia , Infarto do Miocárdio/mortalidade , Fibrilação Ventricular/mortalidade , Métodos Epidemiológicos , França/epidemiologia , Humanos , Tempo de Internação/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/complicações , Prognóstico , Fibrilação Ventricular/complicações
14.
J Interv Card Electrophysiol ; 39(2): 177-84, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24338204

RESUMO

PURPOSE: This study aims to study the clinical implications of the concomitant use of a left ventricular assist device (LVAD) and an implantable cardioverter-defibrillator (ICD). METHODS: In this retrospective study, all patients who underwent LVAD (Heart Mate II) implantation with concomitant ICD therapy at our institution between June 2007 and August 2012 were included. We sought to investigate (1) the electromagnetic interference between LVAD and ICD telemetry, (2) the effect of LVAD implantation on right ventricular (RV) lead parameters and (3) the ventricular tachyarrhythmias (VAs) that occur post-LVAD implantation. RESULTS: Of the 23 patients (53 ± 9 years, 73 % male, LVEF 19 ± 9 %) included, ICD telemetry was lost in four patients post-LVAD implantation (Saint-Jude-Medical Atlas V-193, V-240, V-243, and Sorin CRT-8750), prompting either use of a metal shield (n = 1), a change in position of the programmer head (n = 1) or ICD replacement (n = 2). LVAD implantation was associated with a decrease in both RV signal amplitude (p = 0.04) and RV impedance (p < 0.01), and a trend towards an increased RV pacing threshold (p = 0.08), without affecting clinical outcome. Eleven patients (47.8 %) experienced VAs after LVAD implantation, which on the whole were well tolerated. Their occurrence was strongly linked to a history of VAs before device implantation (p < 0.01). CONCLUSIONS: Electromagnetic interference between LVADs and ICD telemetry may necessitate ICD replacement. LVAD placement is associated with significant changes in RV lead parameters that have minimal clinical significance. VAs occur in approximately half of LVAD patients seen and their occurrence is strongly related to a history of VAs prior to LVAD implantation.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Falha de Equipamento , Insuficiência Cardíaca/prevenção & controle , Coração Auxiliar/efeitos adversos , Fibrilação Ventricular/etiologia , Fibrilação Ventricular/prevenção & controle , Adulto , Idoso , Terapia Combinada/efeitos adversos , Terapia Combinada/instrumentação , Feminino , Insuficiência Cardíaca/complicações , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
15.
J Card Fail ; 19(11): 731-8, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24263116

RESUMO

BACKGROUND: A novel quadripolar left ventricular (LV) pacing lead has the ability to deliver multisite LV pacing (MSLV). We set out to characterize the safety and changes in acute mechanical dyssynchrony with MSLV in cardiac resynchronization therapy (CRT) patients. METHODS AND RESULTS: Prospective multicenter study in 52 patients receiving CRT. An acute pacing protocol comprising 8 MSLV configurations covering a range of delays was compared with conventional CRT (baseline). Transthoracic tissue Doppler imaging (TDI) was used to measure the standard deviation of time to peak contraction of 12 LV segments (Ts-SD) and delayed longitudinal contraction. No ventricular arrhythmia occurred in any of the 52 patients. Complete TDI datasets were collected in 41 patients. Compared with baseline: 1) The mean Ts-SD was significantly lower for the optimal MSLV configuration (35.3 ± 36.4 vs 50.2 ± 29.1 ms; P < .001); 2) at least 1 MSLV configuration exhibited a significant dyssynchrony improvement in 63% of patients; and 3) the mean number of LV segments with delayed longitudinal contractions was significantly reduced with the optimal MSLV configuration (0.37 ± 7.99 vs 2.20 ± 0.19; P < .001). CONCLUSIONS: Acute MSLV was acutely safe, and a proportion of MSLV vectors resulted in a significant reduction in echocardiographic dyssynchrony compared with conventional CRT.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Isquemia Miocárdica/fisiopatologia , Isquemia Miocárdica/terapia , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Esquerda/terapia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico , Função Ventricular Esquerda/fisiologia
16.
Europace ; 15 Suppl 1: i6-i10, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23737234

RESUMO

Pacemaker (PM) and implantable cardioverter defibrillator (ICD) patients are ideally suited to remote management in the form of remote follow-up as well as of remote monitoring, which are both acts of telemedicine. Large randomized trials, such as TRUST, COMPAS, CONNECT, ECOST and EVOLVO, and the huge ALTITUDE registry provided a high level of evidence for the multiple advantages of remote management. These trials demonstrated the capability of early detection of events, the ability to reduce the incidence of inappropriate shocks and also of all charged shocks and this despite fewer in-clinic visits for the patients. The studies also demonstrated the safety of remote management of ICD and PM patients and moreover its positive impact on the survival of patients. Thereby, remote monitoring is clinically much more effective and efficient than conventional follow-up.


Assuntos
Eletrocardiografia Ambulatorial/estatística & dados numéricos , Medicina Baseada em Evidências , Cardiopatias/diagnóstico , Cardiopatias/mortalidade , Cardiopatias/prevenção & controle , Próteses e Implantes/estatística & dados numéricos , Telemedicina/instrumentação , Desfibriladores Implantáveis/estatística & dados numéricos , Diagnóstico por Computador , Humanos , Marca-Passo Artificial/estatística & dados numéricos , Administração dos Cuidados ao Paciente/estatística & dados numéricos , Prevalência , Fatores de Risco , Taxa de Sobrevida , Tecnologia sem Fio/estatística & dados numéricos
17.
Eur Heart J ; 34(8): 605-14, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23242192

RESUMO

AIMS: The ECOST trial examined prospectively the long-term safety and effectiveness of home monitoring (HM) of implantable cardioverter defibrillators (ICD). METHODS AND RESULTS: The trial's primary objective was to randomly compare the proportions of patients experiencing ≥ 1 major adverse event (MAE), including deaths from all causes, and cardiovascular, procedure-related, and device-related MAE associated with HM (active group) vs. ambulatory follow-ups (control group) in a sample of 433 patients. The 221 patients assigned to the active group were seen once a year, unless HM reported an ICD dysfunction or a clinical event requiring an ambulatory visit, while the 212 patients in the control group underwent ambulatory visits every 6 months. The characteristics of the study groups were similar. Over a follow-up of 24.2 months, 38.5% of patients in the active and 41.5% in the control group experienced ≥ 1 MAE (P < 0.05 for non-inferiority). The overall number of shocks delivered was significantly lower in the active (n = 193) than in the control (n = 657) group (P < 0.05) and the proportion of patients who received inappropriate shocks was 52% lower in the active (n = 11) than in the control (n = 22) group (P < 0.05). At the end of the follow-up, the battery longevity was longer in the active group because of a lower number of capacitor charges (499 vs. 2081). CONCLUSION: Our observations indicate that long-term HM of ICD is at least as safe as standard ambulatory follow-ups with respect to a broad spectrum of MAE. It also lowered significantly the number of appropriate and inappropriate shocks delivered, and spared the device battery. Clinical trials registration NCT00989417.


Assuntos
Arritmias Cardíacas/terapia , Desfibriladores Implantáveis/efeitos adversos , Assistência Ambulatorial , Arritmias Cardíacas/mortalidade , Causas de Morte , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Ambulatorial , Estudos Prospectivos , Consulta Remota , Resultado do Tratamento
18.
Pacing Clin Electrophysiol ; 35(10): 1209-16, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22817404

RESUMO

BACKGROUND: Little is known about predictors of antitachycardia pacing (ATP) failure in implantable cardioverter defibrillator (ICD) recipients. Distance between the stimulation site and the ventricular tachycardia (VT) site of origin may critically affect ATP effectiveness. We hypothesized that ATP may be less effective in ICD patients who had basal VT than in those who had apical VT. METHODS: We reviewed data from 52 patients with sustained monomorphic VT and left ventricular disease referred for ICD implantation. ATP was delivered exclusively at the right ventricular apex. The clinical VTs site of origin (basal, midventricular, or apical) was determined in each patient, using 12-lead electrocardiogram. VTs episodes treated with ATP during the 1-year follow-up were studied. ATP success rate (%), defined as the ratio between the number of successful ATP sequences and the number of delivered ATP sequences, was determined in each patient. RESULTS: VT exit site was apical in 19 patients (36%), basal in 18 patients (35%), and midventricular in 15 patients (29%). In those 52 patients, 1,393 ATP sequences, delivered to treat 761 VT episodes, were analyzed. ATP success rate was found to be associated with the VT site of origin (median [interquartile range]): basal (33%[11-67]), midventricular (50%[37-100]), apical (100%[41-100]) (P = 0.027). Multivariate analysis identified basal VT site of origin as an independent predictor of ATP failure (P = 0.023). CONCLUSION: ATP is less effective in ICD patients who had basal VT than in those who had apical VT before ICD implantation.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Falha de Equipamento , Taquicardia Ventricular/terapia , Idoso , Eletrocardiografia/instrumentação , Eletrocardiografia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Taquicardia Ventricular/fisiopatologia
20.
Eur Heart J Cardiovasc Imaging ; 13(10): 840-8, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22398658

RESUMO

AIMS: The present study was undertaken to investigate the concordance between longitudinal two-dimensional (2D)-speckle-tracking data and endocardial mapping for localizing atrioventricular accessory pathways (AP), and whether longitudinal 2D-speckle-tracking imaging accurately identifies the contractile abnormalities associated with AP and the effect of radiofrequency ablation. METHODS AND RESULTS: Echocardiograms were repeated twice in 40 patients with Wolff-Parkinson-White (WPW) syndrome (before and early after ablation) and in 40 healthy controls to obtain longitudinal 2D strain and strain rate data. The site of ablation was considered as the gold standard for the AP localization. While control patients had a homogeneous strain pattern, all but two patients with WPW had an abnormal deformation pattern with three peaks in one or two basal contiguous segments: an early peak concomitantly with the delta wave followed by a systolic and a post-sytolic one. The rapid increase in LV longitudinal deformation within the basal pre-excited zone resulted in a pre-systolic peak strain rate at the beginning of the delta wave by SR imaging that was not found in controls. The early basal contraction spread towards the mid-ventricle before merging with the normal activated segments in 15 patients (39%). Contractile abnormalities were no more than one adjacent segment different compared with the AP ablation site in all these 38 patients. Regional strain was impaired in the pre-excited areas especially in AP localized in the interventricular septum. The abnormal deformation pattern persisted in 16 (42%) patients despite successful radiofrequency ablation. However, the difference in the regional strain between WPW patients and controls did not remain after ablation. CONCLUSION: Longitudinal 2D-speckle-tracking data accurately match with endocardial mapping findings for localizing AP. Longitudinal 2D-speckle-tracking imaging accurately identifies AP-associated contractile abnormalities. Longitudinal 2D-speckle-tracking identifies persistence of local ventricular pre-excitation immediately after successful ablation.


Assuntos
Feixe Acessório Atrioventricular/cirurgia , Nó Atrioventricular/patologia , Ablação por Cateter , Ecocardiografia , Síndrome de Wolff-Parkinson-White/cirurgia , Feixe Acessório Atrioventricular/diagnóstico por imagem , Feixe Acessório Atrioventricular/patologia , Adulto , Nó Atrioventricular/diagnóstico por imagem , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Estudos Prospectivos , Estatísticas não Paramétricas , Taquicardia Supraventricular/diagnóstico por imagem , Taquicardia Supraventricular/patologia , Fatores de Tempo , Síndrome de Wolff-Parkinson-White/diagnóstico por imagem , Síndrome de Wolff-Parkinson-White/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...