Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 211
Filtrar
1.
Heart Rhythm O2 ; 5(2): 113-121, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38545324

RESUMO

Background: Infranodal conduction disorders are common after transcatheter aortic valve replacement (TAVR). Risk factors are incompletely understood. Objective: The purpose of this study was to assess the impact of valve implantation depth and calcium burden of the device landing zone on infranodal conduction intraprocedure pre- and post-TAVR. Methods: In all patients undergoing TAVR between June 2020 and June 2021, the His-ventricle (HV) interval was measured pre- and post-valve deployment. The difference between the 2 measurements defined delta HV, whereas infranodal conduction delay was defined as HV interval >55 ms. Valve implantation depth was measured as the distance between the aortic annular plane and the ventricular prosthesis end. Calcium burden was quantified as the volume of calcium in 6 regions of interest: the non-, right, and left coronary cusps (NCC, RCC, and LCC, respectively) and the corresponding regions of the left ventricular outflow tract (LVOT) underlying each cusp (LVOTNCC, LVOTRCC, LVOTLCC, respectively). Results: Of 101 patients (mean age 81 ± 5.7 years; 47% women), 37 demonstrated infranodal conduction delay intraprocedure post-TAVR. Overall, mean implantation depth was 5 ± 3.1 mm, median calcium volume was 2080 mm3 [interquartile range 632-2400]. Delta HV showed no correlation with implantation depth or calcium burden (r = -0.08 and r = 0.12, respectively). However, LVOTNCC calcification was a significant predictor for infranodal conduction delay post-valve deployment in a multivariable logistic regression model (odds ratio 1.62 per 100-mm3 increase (95% confidence interval 1.06-2.69; P = .04). Conclusion: Assessment of LVOTNCC calcification may identify patients at risk for infranodal conduction delay after TAVR, whereas implantation depth did not predict infranodal conduction delay.

2.
Nat Methods ; 2023 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-38110637

RESUMO

Cryo-focused ion beam milling of frozen-hydrated cells and subsequent cryo-electron tomography (cryo-ET) has enabled the structural elucidation of macromolecular complexes directly inside cells. Application of the technique to multicellular organisms and tissues, however, is still limited by sample preparation. While high-pressure freezing enables the vitrification of thicker samples, it prolongs subsequent preparation due to increased thinning times and the need for extraction procedures. Additionally, thinning removes large portions of the specimen, restricting the imageable volume to the thickness of the final lamella, typically <300 nm. Here we introduce Serial Lift-Out, an enhanced lift-out technique that increases throughput and obtainable contextual information by preparing multiple sections from single transfers. We apply Serial Lift-Out to Caenorhabditis elegans L1 larvae, yielding a cryo-ET dataset sampling the worm's anterior-posterior axis, and resolve its ribosome structure to 7 Å and a subregion of the 11-protofilament microtubule to 13 Å, illustrating how Serial Lift-Out enables the study of multicellular molecular anatomy.

3.
J Clin Med ; 12(21)2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37959355

RESUMO

We present the results of a combined approach for transapical aortic valve replacement and minimally invasive coronary artery bypass grafting (taTAVI-MIDCAB) in patients with combined aortic stenosis and coronary artery disease. BACKGROUND: For patients presenting with aortic stenosis and coronary artery disease, a simultaneous procedure addressing both diseases is recommended to reduce operative risk. In high-risk patients with hostile femoral or coronary axis, taTAVI-MIDCAB can be an alternative minimally invasive approach, offering the benefits of left interior mammary artery to left anterior descending coronary artery (LIMA-LAD) grafting. METHODS: From 2014 to 2022, 10 patients underwent taTAVI-MIDCAB for combined coronary and severe aortic stenosis in the hybrid operation theater at our institution. We assessed perioperative outcomes and follow-up outcomes. RESULTS: The median age was 83 years (81 to 86). The procedure was successfully performed in all patients without conversion to sternotomy. The median length of hospital and intensive care unit stay was 9 days (7 to 16) and 2.5 days (1 to 5), respectively. The median flow over the coronary artery bypass was 31 (22 to 44) mL/min, with a pulsatility index (PI) of 2.4 (2.1 to 3.2). Mild paravalvular leak occurred in 2 patients (10%). There were no neurological events nor acute kidney injury. Pacemaker implantation was required in 1 patient (10%). CONCLUSIONS: Simultaneous surgical coronary revascularization and interventional valve implantation in the setting of a hostile femoral and coronary axis appears to be safe and beneficial.

4.
Lancet ; 402(10416): 1979-1990, 2023 11 25.
Artigo em Inglês | MEDLINE | ID: mdl-37898137

RESUMO

BACKGROUND: Biodegradable polymer sirolimus-eluting stents improve early stent-related clinical outcomes compared to durable polymer everolimus-eluting stents in patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention. The long-term advantages of biodegradable polymer sirolimus-eluting stents after complete degradation of its polymer coating in patients with STEMI remains however uncertain. METHODS: BIOSTEMI Extended Survival (BIOSTEMI ES) was an investigator-initiated, follow-up extension study of the BIOSTEMI prospective, multicentre, single-blind, randomised superiority trial that compared biodegradable polymer sirolimus-eluting stents with durable polymer everolimus-eluting stents in patients with STEMI undergoing primary percutaneous coronary intervention at ten hospitals in Switzerland. All individuals who had provided written informed consent for participation in the BIOSTEMI trial were eligible for this follow-up study. The primary endpoint was target lesion failure, defined as a composite of cardiac death, target vessel myocardial re-infarction, or clinically indicated target lesion revascularisation, at 5 years. Superiority of biodegradable polymer sirolimus-eluting stents over durable polymer everolimus-eluting stents was declared if the Bayesian posterior probability for a rate ratio (RR) of less than 1 was greater than 0·975. Analyses were performed according to the intention-to-treat principle. The study was registered with ClinicalTrials.gov, NCT05484310. FINDINGS: Between April 26, 2016, and March 9, 2018, 1300 patients with STEMI (1622 lesions) were randomly allocated in a 1:1 ratio to treatment with biodegradable polymer sirolimus-eluting stents (649 patients, 816 lesions) or durable polymer everolimus-eluting stents (651 patients, 806 lesions). At 5 years, the primary composite endpoint of target lesion failure occurred in 50 (8%) patients treated with biodegradable polymer sirolimus-eluting stents and in 72 (11%) patients treated with durable polymer everolimus-eluting stents (difference of -3%; RR 0·70, 95% Bayesian credible interval 0·51-0·95; Bayesian posterior probability for superiority 0·988). INTERPRETATION: In patients undergoing primary percutaneous coronary intervention for STEMI, biodegradable polymer sirolimus-eluting stents were superior to durable polymer everolimus-eluting stents with respect to target lesion failure at 5 years of follow-up. The difference was driven by a numerically lower risk for ischaemia-driven target lesion revascularisation. FUNDING: Biotronik.


Assuntos
Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Sirolimo/uso terapêutico , Everolimo/uso terapêutico , Seguimentos , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Infarto do Miocárdio com Supradesnível do Segmento ST/tratamento farmacológico , Polímeros , Teorema de Bayes , Método Simples-Cego , Estudos Prospectivos , Resultado do Tratamento , Implantes Absorvíveis , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/métodos
5.
J Clin Med ; 12(18)2023 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-37762811

RESUMO

INTRODUCTION: Transcatheter aortic valve replacement (TAVR) has become a widely used, comparably efficient and safe alternative to surgical aortic valve replacement (SAVR). Its utilization continues to grow, especially among younger patients. Despite improvements in durability, degeneration and subsequent re-interventions of failed prosthetic valves are still common. Even though valve-in-valve procedures have become more frequent, little is known about the trends over time or about clinical and echocardiographic long-term outcomes. MATERIALS AND METHODS: Patients who underwent a valve-in-valve procedure between December 2011 and December 2022 in a large tertiary university hospital were analyzed. Primary outcomes were defined as procedural and device successes as well as event-free survival. Secondary analyses between subsets of patients divided by index valve and date of procedure were performed. RESULTS: Among 1407 procedures, 58 (4%) were valve-in-valve interventions, with an increased frequency observed over time. Overall, technical success was achieved in 88% and device success in 85% of patients. Complications were predominantly minor, with similar success rates among TAVR-in-SAVR (TiSAVR) and TAVR-in-TAVR (TiTAVR). Notably, there were significant and lasting improvements in mean echocardiographic gradients at 1 year. Event-free survival was 76% at one month and 69% at one year. CONCLUSIONS: Over the last decade, a rising trend of valve-in-valve procedures was observed. Despite an increase in procedures, complications show a contrasting decline with improved technical and device success over time. TiSAVR and TiTAVR showed comparable rates of procedural and device success as well as similar outcomes, highlighting the utility of valve-in-valve procedures in an aging population.

6.
Sci Rep ; 13(1): 15227, 2023 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-37710028

RESUMO

Microscopic compartmentalization is beneficial in synthetic chemistry and indispensable for the evolution of life to separate a reactive "inside" from a hydrolyzing "outside". Here, we show compartmentalization in aqueous solution containing mixtures of fatty acids up to 19 carbon atoms which were synthesized by one-pot reactions of acetylene and carbon monoxide in contact with nickel sulfide at 105 °C, reaction requirements which are compatible to Hadean Early Earth conditions. Based on confocal, dynamic light scattering (DLS) and transmission electron microscopy (TEM) measurements, vesicle-like structures with diameters of 10-150 nm are formed after solvent extraction and resolubilisation. Moreover fluorescent dye was encapsulated into the structures proving their vesicular properties. This self-assembly could also have occurred on Early Earth as a crucial step in establishing simple membranes of proto-cells as a prerequisite in the evolution of metabolism and life.

8.
J Mol Biol ; 435(20): 168253, 2023 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-37640152

RESUMO

Engineering in vitro selected RNA aptamers into in vivo functional riboswitches represents a long-standing challenge in molecular biology. The highly specific aptamer domain of the riboswitch undergoes a conformational adjustment in response to ligand sensing, which in turn exerts the regulatory function. Besides essential factors like structural complexity and ligand binding kinetics, the active role of magnesium ions in stabilizing RNA tertiary structures and assisting in ligand binding can be a vital criterion. We present spectroscopic studies on the magnesium ion-driven folding of the Tetracycline binding aptamer. Using fluorescent labels, the aptamer pre-folding and subsequent ligand binding is monitored by magnesium titration experiments and time-resolved stopped-flow measurements. A minimum concentration of 0.5 mM magnesium is required to fold into a magnesium ion-stabilized binding-competent state with a preformed binding pocket. Tetracycline binding causes a pronounced conformational change that results in the establishment of the triple helix core motif, and that further propagates towards the closing stem. By a dynamic acquisition of magnesium ions, a kink motif is formed at the intersection of the triple helix and closing stem regions. This ultimately entails a stabilization of the closing stem which is discussed as a key element in the regulatory function of the Tetracycline aptamer.


Assuntos
Antibacterianos , Aptâmeros de Nucleotídeos , Magnésio , Riboswitch , Tetraciclina , Antibacterianos/química , Aptâmeros de Nucleotídeos/química , Íons , Ligantes , Magnésio/química , Conformação de Ácido Nucleico , Tetraciclina/química
9.
J Am Coll Cardiol ; 82(18): 1737-1747, 2023 10 31.
Artigo em Inglês | MEDLINE | ID: mdl-37640248

RESUMO

BACKGROUND: The frequency, characteristics, and outcomes of patients treated with high-intensity lipid-lowering therapy and showing concomitant atheroma volume reduction, lipid content reduction, and increase in fibrous cap thickness (ie, triple regression) are unknown. OBJECTIVES: This study was designed to investigate rates, determinants, and prognostic implications of triple regression in patients presenting with acute myocardial infarction and treated with high-intensity lipid-lowering therapy. METHODS: The PACMAN-AMI (Effects of the PCSK9 Antibody Alirocumab on Coronary Atherosclerosis in Patients with Acute Myocardial Infarction) trial used serial intravascular ultrasound, near-infrared spectroscopy, and optical coherence tomography to compare the effects of alirocumab vs placebo in patients receiving high-intensity statin therapy. Triple regression was defined by the combined presence of percentage of atheroma volume reduction, maximum lipid core burden index within 4 mm reduction, and minimal fibrous cap thickness increase. Clinical outcomes at 1-year follow-up were assessed. RESULTS: Overall, 84 patients (31.7%) showed triple regression (40.8% in the alirocumab group vs 23.0% in the placebo group; P = 0.002). On-treatment low-density lipoprotein cholesterol levels were lower in patients with vs without triple regression (between-group difference: -27.1 mg/dL; 95% CI: -37.7 to -16.6 mg/dL; P < 0.001). Triple regression was independently predicted by alirocumab treatment (OR: 2.83; 95% CI: 1.57-5.16; P = 0.001) and a higher baseline maximum lipid core burden index within 4 mm (OR: 1.03; 95% CI: 1.01-1.06; P = 0.013). The composite clinical endpoint of death, myocardial infarction, and ischemia-driven revascularization occurred less frequently in patients with vs without triple regression (8.3% vs 18.2%; P = 0.04). CONCLUSIONS: Triple regression occurred in one-third of patients with acute myocardial infarction who were receiving high-intensity lipid-lowering therapy and was associated with alirocumab treatment, higher baseline lipid content, and reduced cardiovascular events. (Vascular Effects of Alirocumab in Acute MI-Patients [PACMAN-AMI]; NCT03067844).


Assuntos
Doença da Artéria Coronariana , Inibidores de Hidroximetilglutaril-CoA Redutases , Infarto do Miocárdio , Placa Aterosclerótica , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/tratamento farmacológico , Pró-Proteína Convertase 9 , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/tratamento farmacológico , Infarto do Miocárdio/tratamento farmacológico , Lipídeos , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Resultado do Tratamento
10.
Clin Res Cardiol ; 2023 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-37495797

RESUMO

BACKGROUND AND OBJECTIVES: Recent data have established non-inferiority of drug-coated balloons (DCB) compared to drug-eluting stents (DES) for treatment of small-vessel coronary artery disease. Since coronary vessels in women might have anatomical and pathophysiological particularities, the safety of the DCB strategy among women compared to men needs to be assessed in more detail. METHODS: In BASKET-SMALL 2, patients with de novo lesions in coronary vessels < 3 mm and an indication for percutaneous coronary intervention were randomly allocated (1:1) to DCB vs. DES after successful lesion preparation. The primary objective of the randomized trial was to establish non-inferiority of DCB vs. DES regarding major adverse cardiac events (MACE; i.e., cardiac death, non-fatal myocardial infarction, and target vessel revascularization) after 12 months. The aim of the current sub-analysis is to evaluate whether the DCB strategy is equally safe among women and men after 12 and 36 months. RESULTS: Among 758 randomized patients, 382 were assigned to DCB (23% women) and 376 to DES (30% women). In general, women were older, had more often diabetes mellitus and renal insufficiency, and presented more often with an acute coronary syndrome, whereas men were more often smokers, had multivessel disease and a previous history of acute myocardial infarction, and received a treatment with a statin. After 3 years, the primary clinical end point was not significantly different between groups (13% women vs. 16% men, HR 0.82; 95% CI 0.52-1.30; p = 0.40). There was no interaction between sex and coronary intervention strategy regarding MACE at 36 months (10% women vs. 16% men in DCB, 16% women vs. 15% men in DES; pinteraction = 0.31). CONCLUSION: In small native coronary artery disease, there was no statistically significant effect of sex on the difference between DCB and DES regarding MACE up to 36 months. CLINICAL TRIAL REGISTRATION: URL: http://www. CLINICALTRIALS: gov . Unique identifier: NCT01574534. CAD coronary artery disease, MACE major adverse cardiovascular events, HR Hazard ratio, DCB drug-coated balloon, DES drug-eluting stent.

11.
Artigo em Inglês | MEDLINE | ID: mdl-37327913

RESUMO

BACKGROUND: The aim of this study was to report outcomes of all patients undergoing transcatheter mitral valve implantation with the Tendyne Mitral Valve System (Tendyne) in Switzerland. METHODS: We retrospectively analyzed preoperative echocardiographic and computed tomography (CT) data, procedural findings, and 30-day and 1-year follow-up echocardiographic and clinical data of patients who underwent transcatheter mitral valve implantation with Tendyne in Switzerland. RESULTS: A total of 24 patients (age, 74.8 ± 7.8 years; 67% male) underwent transapical transcatheter mitral valve implantation with Tendyne between June 2020 and October 2022. Technical success rate was 96%. In five patients, concomitant interventions in the form of transcatheter aortic valve implantation (one patient), minimally invasive direct coronary artery bypass (one patient), and transcatheter edge-to-edge repair (three patients) were performed prior to or after the index procedure. There was one device embolization, and two patients required valve retrieval. In-hospital outcomes included one stroke and three major bleeding events. None of the patients died within 30 days. Two patients were rehospitalized for decompensated heart failure. At 1-year follow-up, there were three noncardiovascular-related deaths. CONCLUSION: Transcatheter mitral valve implantation with Tendyne is feasible to treat polymorbid patients suffering from complex mitral valve disease as well as patients with previous mitral interventions. Perioperative risk was acceptable and procedural success high.

12.
EuroIntervention ; 19(4): e286-e296, 2023 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-37341586

RESUMO

BACKGROUND: Treatment with proprotein convertase subtilisin/kexin type 9 (PCSK9) inhibitors on top of statins leads to plaque regression and stabilisation. The effects of PCSK9 inhibitors on coronary physiology and angiographic diameter stenosis (DS%) are unknown. AIMS: This study aimed to investigate the effects of the PCSK9 inhibitor alirocumab on coronary haemodynamics as assessed by quantitative flow ratio (QFR) and DS% by three-dimensional quantitative coronary angiography (3D-QCA) in non-infarct-related arteries (non-IRA) among acute myocardial infarction (AMI) patients. METHODS: This was a prespecified substudy of the randomised controlled PACMAN-AMI trial, comparing alirocumab versus placebo on top of rosuvastatin. QFR and 3D-QCA were assessed at baseline and 1 year in any non-IRA ≥2.0 mm and 3D-QCA DS% >25%. The prespecified primary endpoint was the number of patients with a mean QFR increase at 1 year, and the secondary endpoint was the change in 3D-QCA DS%. RESULTS: Of 300 enrolled patients, 265 had serial follow-up, of which 193 underwent serial QFR/3D-QCA analysis in 282 non-IRA. At 1 year, QFR increased in 50/94 (53.2%) patients with alirocumab versus 40/99 (40.4%) with placebo (Δ12.8%; odds ratio 1.7, 95% confidence interval [CI]: 0.9 to 3.0; p=0.076). DS% decreased by 1.03±7.28% with alirocumab and increased by 1.70±8.27% with placebo (Δ-2.50%, 95% CI: -4.43 to -0.57; p=0.011). CONCLUSIONS: Treatment of AMI patients with alirocumab versus placebo for 1 year resulted in a significant regression in angiographic DS%, whereas no overall improvement of coronary haemodynamics was observed. CLINICALTRIALS: gov: NCT03067844.


Assuntos
Inibidores de Hidroximetilglutaril-CoA Redutases , Infarto do Miocárdio , Placa Aterosclerótica , Humanos , Pró-Proteína Convertase 9 , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Infarto do Miocárdio/tratamento farmacológico , Placa Aterosclerótica/tratamento farmacológico , Artérias
13.
J Cardiovasc Electrophysiol ; 34(6): 1464-1468, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37146212

RESUMO

INTRODUCTION: Electrophysiological testing has been proposed in the latest European Society of Cardiology (ESC) guidelines for cardiac pacing to identify left bundle branch block (LBBB) patients with infrahisian conduction delay (IHCD) after transcatheter aortic valve replacement (TAVR). While in general IHCD is defined by a His-ventricular (HV) interval of >55 ms, a cut-off of ≥70 ms to trigger pacemaker (PM) implantation has been proposed in the latest ESC guidelines. The ventricular pacing (VP) burden during follow-up in such patients is largely unknown. As such, we aimed to assess the VP burden during follow-up of patients receiving PM therapy for LBBB after TAVR based on an HV interval > 55 ms and ≥70 ms. METHODS: All patients with new-onset or pre-existing LBBB after undergoing TAVR at a tertiary referral center underwent EP testing the day after TAVR. In patients with a prolonged HV interval (>55 ms), PM implantation was performed by a trained electrophysiologist in a standardized fashion. All devices were programmed to avoid unnecessary VP by specific algorithms (e.g., AAI-DDD). RESULTS: 701 patients underwent TAVR at the University Hospital of Basel. One hundred seventy-seven patients presented with new-onset or pre-existing LBBB the day following TAVR and underwent EP testing. An HV interval > 55 ms was found in 58 patients (33%) and an HV interval ≥ 70 ms in 21 patients (12%). 51 patients (mean age 84 ± 6.2 years, 45% women) agreed to receive a PM, out of which 20 (39%) patients had an HV Interval over 70 ms. Atrial fibrillation was present in 53% of the patients. A dual chamber PM was implanted in 39 (77%), and a single chamber PC in 12 (23%) patients, respectively. Median follow-up was 21 months. The median VP burden overall was 3%. The median VP burden was not significantly different between patients with an HV ≥ 70 ms (6.5 [0.8-52]) and those with an HV between 55 and 69 ms (2 [0-17], p = .23). 31% of patients demonstrated a VP burden < 1%, 27% 1%-5% and 41% > 5%. The median HV intervals in patients with VP burdens < 1%, 1%-5% and >5% were 66 (IQR 62-70) ms, 66 (IQR 63-74) ms and 68 (IQR 60-72) ms, respectively, p = .52. When only assessing patients with an HV interval 55-69 ms, 36% demonstrated a VP burden of <1%, 29% of 1%-5% and 35% of >5%. In patients with an HV Interval ≥ 70 ms, 25% demonstrated a VP burden < 1%, 25% of 1%-5% and 50% of >5% %, p = .64 (Figure). CONCLUSION: In patients with LBBB after TAVR and IHCD defined by an HV interval > 55 ms, VP burden is relevant in a non-negligible amount of patients during follow-up. Further studies are warranted to define the optimal cut-off value for the HV interval or to develop risk models incorporating HV measurements and other risk factors to trigger PM implantation in patients with LBBB after TAVR.


Assuntos
Estenose da Valva Aórtica , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Masculino , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/etiologia , Bloqueio de Ramo/terapia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Arritmias Cardíacas/terapia , Marca-Passo Artificial/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia
14.
Am Heart J ; 263: 73-84, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37192697

RESUMO

BACKGROUND: Whether ultrathin-strut stents are particularly beneficial for lesions requiring implantation of more than 1 stent is unknown. METHODS: In a post-hoc lesion-level analysis of 2 randomized trials comparing ultrathin-strut biodegradable polymer Sirolimus-eluting stents (BP-SES) vs thin-strut durable polymer Everolimus-eluting stents (DP-EES), lesions were stratified into multistent lesions (MSL) vs single-stent lesions (SSL). The primary endpoint was target lesion failure (TLF), a composite of lesion-related unclear/cardiac death, myocardial infarction (MI), or revascularization, at 24 months. RESULTS: Among 5328 lesions in 3397 patients, 1492 (28%) were MSL (722 with BP-SES, 770 with DP-EES). At 2 years, TLF occurred in 63 lesions (8.9%) treated with BP-SES and 60 lesions (7.9%) treated with DP-EES in the MSL-group (subdistibution hazard ratio [SHR], 1.13; 95% CI, 0.77-1.64; P = .53), and in 121 (6.4%) and 136 (7.4%) lesions treated with BP-SES and DP-EES respectively (SHR, 0.86; 95% CI, 0.62-1.18; P = .35) in the SSL-group (P for interaction = .241). While the rates of lesion-related MI or revascularization were significantly lower in SSL treated with BP-SES as compared to DP-EES (3.5% vs 5.2%; SHR, 0.67; 95% CI 0.46-0.97; P = .036), no significant difference was observed in MSL (7.1% vs 5.4%; SHR, 1.31; 95% CI 0.85-2.03; P = .216) with significant interaction between groups (P for interaction = .014). CONCLUSIONS: Rates of TLF are similar between ultrathin-strut BP-SES and thin-strut DP-EES in MSL and SSL. The use of ultrathin-strut BP-SES vs thin-strut DP-EES did not prove to be particularly beneficial for the treatment of multistent lesions. TRIAL REGISTRATION: Post-hoc analysis from the BIOSCIENCE (NCT01443104) and BIOSTEMI (NCT02579031) trials.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Implantes Absorvíveis , Doença da Artéria Coronariana/cirurgia , Everolimo/farmacologia , Infarto do Miocárdio/epidemiologia , Polímeros , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Sirolimo , Resultado do Tratamento
15.
J Cardiovasc Dev Dis ; 10(3)2023 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-36975883

RESUMO

BACKGROUND: We evaluated the outcome of PCI of de novo stenosis with drug-coated balloons (DCB) versus drug-eluting stents (DES) in patients with insulin-treated diabetes mellitus (ITDM) versus non-insulin-treated diabetes mellitus (NITDM). METHODS: Patients were randomized in the BASKET-SMALL 2 trial to DCB or DES and followed over 3 years for MACE (cardiac death, non-fatal myocardial infarction [MI], and target vessel revascularization [TVR]). Outcome in the diabetic subgroup (n = 252) was analyzed with respect to ITDM or NITDM. RESULTS: In NITDM patients (n = 157), rates of MACE (16.7% vs. 21.9%, hazard ratio [HR] 0.68, 95% confidence interval [CI] 0.29-1.58, p = 0.37), death, non-fatal MI, and TVR (8.4% vs. 14.5%, HR 0.30, 95% CI 0.09-1.03, p = 0.057) were similar between DCB and DES. In ITDM patients (n = 95), rates of MACE (DCB 23.4% vs. DES 22.7%, HR 1.12, 95% CI 0.46-2.74, p = 0.81), death, non-fatal MI, and TVR (10.1% vs. 15.7%, HR 0.64, 95% CI 0.18-2.27, p = 0.49) were similar between DCB and DES. TVR was significantly lower with DCB versus DES in all diabetic patients (HR 0.41, 95% CI 0.18-0.95, p = 0.038). CONCLUSIONS: DCB compared to DES for treatment of de novo coronary lesions in diabetic patients was associated with similar rates of MACE and numerically lower need for TVR both for ITDM and NITDM patients.

17.
Catheter Cardiovasc Interv ; 101(4): 687-700, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36807456

RESUMO

BACKGROUND: Ultrathin-strut biodegradable polymer sirolimus-eluting stents (BP-SES) are superior to thin-strut durable polymer everolimus-eluting stents (DP-EES) with respect to target lesion failure (TLF) at 2 years among patients with ST-segment elevation myocardial infarction (STEMI). We sought to determine the impact of primary percutaneous coronary intervention (pPCI) complexity on long-term clinical outcomes with BP-SES versus DP-EES in STEMI patients. METHODS: We performed a post hoc subgroup analysis from the BIOSTEMI (NCT02579031) randomized trial, which included individual data from 407 STEMI patients enrolled in the BIOSCIENCE trial (NCT01443104). STEMI patients were randomly assigned to treatment with ultrathin-strut BP-SES or thin-strut DP-EES, and further categorized into those undergoing complex versus noncomplex pPCI. Complex pPCI was defined by the presence of ≥1 of the following criteria: 3 vessel treatment, ≥3 stents implanted, ≥3 lesions treated, bifurcation lesion with ≥2 stents implanted, total stent length ≥60 mm, and/or chronic total occlusion treatment. The primary endpoint was TLF, a composite of cardiac death, target-vessel myocardial reinfarction, or clinically indicated target lesion revascularization, within 2 years. RESULTS: Among a total of 1707 STEMI patients, 421 (24.7%) underwent complex pPCI. Baseline characteristics were similar between groups. At 2 years, TLF occurred in 14 patients (7.1%) treated with BP-SES and 25 patients (11.6%) treated with DP-EES (hazard ratio [HR]: 0.62; 95% confidence interval [CI]: 0.32-1.19; p = 0.15) in the complex pPCI group, and in 28 patients (4.4%) treated with BP-SES and 49 patients (8.2%) treated with DP-EES (HR: 0.54; 95% CI: 0.34-0.86; p = 0.008; p for interaction = 0.74) in the noncomplex pPCI group. Individual TLF components and stent thrombosis rates did not significantly differ between groups. CONCLUSION: In a post hoc subgroup analysis from the BIOSTEMI randomized trial, ultrathin-strut BP-SES were superior to thin-strut DP-EES with respect to TLF at 2 years among STEMI patients undergoing both complex and noncomplex pPCI.


Assuntos
Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Implantes Absorvíveis , Stents Farmacológicos , Everolimo/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Polímeros , Desenho de Prótese , Sirolimo/efeitos adversos , Infarto do Miocárdio com Supradesnível do Segmento ST/etiologia , Resultado do Tratamento , Stents
18.
Bioengineering (Basel) ; 10(2)2023 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-36829650

RESUMO

Transapical transcatheter aortic valve implantation (TA-TAVI) is generally considered to be associated with increased morbidity and mortality compared with transfemoral transcatheter aortic valve implantation TAVI (TF-TAVI). We aimed to compare different patient risk profiles, access-related complications, and long-term survival using inverse probability treatment weighting. This is a retrospective, single-center analysis of 925 consecutive patients with aortic valve stenosis undergoing TF-TAVI (n = 802) or TA-TAVI (n = 123) at the University Hospital Basel, Switzerland, as a single procedure between September 2011 and August 2020. Baseline characteristics revealed a higher perioperative risk as reflected in the EuroSCORE II (geometric mean 2.3 (95% confidence interval (CI) 2.2 to 2.4) vs. 3.7 (CI 3.1 to 4.5); before inverse probability of treatment weighting (IPTW) p < 0.001) in the transfemoral than in the transapical group, respectively. After 30 days, TF-TAVI patients had a higher incidence of any bleeding than TA-TAVI patients (TF-TAVI n = 146 vs. TA-TAVI n = 15; weighted hazard ratio (HR) 0.52 (0.29 to 0.95); p = 0.032). After 5 years, all-cause mortality did not differ between the two groups (TF-TAVI n = 162 vs. TA-TAVI n = 45; weighted HR 1.31, (0.92 to 1.88); p = 0.138). With regard to our data, we could demonstrate, despite a higher perioperative risk, the short- and long-term safety and efficacy of the transapical approach for TAVI therapies. Though at higher perioperative risk, transapically treated patients suffered from less bleeding or vascular complications than transfemorally treated patients. It is of utmost interest that 5-year mortality did not differ between the groups.

20.
Chem Asian J ; 17(24): e202201077, 2022 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-36321802

RESUMO

Protein synthesis via ribosomes is a fundamental process in all known living organisms. However, it can be completely stalled by removing a single nucleobase (depurination) at the sarcin/ricin loop of the ribosomal RNA. In this work, we describe the preparation and optimization process of a fluorescent probe that can be used to visualize depurination. Starting from a fluorescent thiophene nucleobase analog, various RNA probes that fluoresce exclusively in the presence of a depurinated sarcin/ricin-loop RNA were designed and characterized. The main challenge in this process was to obtain a high fluorescence signal in the hybridized state with an abasic RNA strand, while keeping the background fluorescence low. With our new RNA probes, the fluorescence intensity and lifetime can be used for efficient monitoring of depurinated RNA.


Assuntos
Ricina , Ricina/metabolismo , Sondas RNA , RNA , Fluorescência , Purinas/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...