Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Cardiol Rev ; 2024 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-38520337

RESUMO

Furoscix, a subcutaneous pH-neutral formulation of furosemide, obtained US Food and Drug Administration approval in October 2022 for adult patients with New York Heart Association class II and class III chronic heart failure. This approval marks an anticipated potential shift in the traditional management of decongestive therapy in chronic heart failure patients from the confines of the hospital to more accessible outpatient or home-based care. In this review, we will summarize existing evidence regarding the use of subcutaneous furosemide in comparison to both oral and intravenous formulations, highlighting the demonstrable benefits of its application in both outpatient and inpatient settings, and also discuss several factors that may limit its use.

2.
JACC Cardiovasc Interv ; 14(20): 2215-2227, 2021 10 25.
Artigo em Inglês | MEDLINE | ID: mdl-34600871

RESUMO

OBJECTIVES: The aim of this study was to clarify the dynamics of the mitral annulus throughout the cardiac cycle and its relevance to transcatheter mitral valve replacement (TMVR) sizing and case selection. BACKGROUND: Limited data are available regarding the relevance of mitral annular (MA) and neo-left ventricular outflow tract (LVOT) dynamics in the overall population presenting with significant mitral valve disease. METHODS: Patients attending a combined surgical-transcatheter heart valve clinic for severe symptomatic mitral valve disease were assessed using multiphase computed tomography. The relative influence of MA and neo-LVOT dynamics to TMVR case selection was studied. RESULTS: A total of 476 patients with significant mitral valve disease were evaluated. In 99 consecutive patients with severe mitral regurgitation, a 10-phase assessment showed that the mitral annulus was on average largest in late systole. On comparing maximal MA dimension with late systolic dimension, TMVR size assignment changed in 24.2% of patients. If the average MA perimeter was used to determine sizing, 48.5% were excluded because of MA dimension being too large; in a multiphase assessment of the neo-LVOT, an additional 16.2% were excluded on the basis of neo-LVOT dimension. In an expanded series of 312 consecutive patients, selection protocol influenced anatomical exclusion: a manufacturer-proposed early systolic approach excluded 69.2% of patients, whereas a late systolic approach excluded 82.7% of patients, the vast majority because of large mitral annuli. CONCLUSIONS: Contemporary TMVR can treat only a minority of patients with severe mitral regurgitation, principally because of limitations of large MA dimension.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Obstrução do Fluxo Ventricular Externo , Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento
3.
Catheter Cardiovasc Interv ; 98(2): 319-327, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-33180381

RESUMO

BACKGROUND: Patients with renal insufficiency have poor short-term outcomes after transcatheter aortic valve replacement (TAVR). METHODS: Retrospective chart review identified 575 consecutive patients not on hemodialysis who underwent TAVR between September 2014 and January 2017. Outcomes were defined by VARC-2 criteria. Primary outcome of all-cause mortality was evaluated at a median follow-up of 811 days (interquartile range 125-1,151). RESULTS: Preprocedural glomerular filtration rate (GFR) was ≥60 ml/min in 51.7%, 30-60 ml/min in 42.1%, and < 30 ml/min in 6.3%. Use of transfemoral access (98.8%) and achieved device success (91.0%) did not differ among groups, but less contrast was used with lower GFR (23 ml [15-33], 24 ml [14-33], 13 ml [8-20]; p < .001). Peri-procedural stroke (0.7%, 2.1%, 11.1%; p < .001) was higher with lower GFR. Core lab analysis of preprocedural computed tomography scans of patients who developed a peri-procedural stroke identified potential anatomic substrate for stroke in three out of four patients with GFR 30-60 ml/min and all three with GFR <30 ml/min (severe atheroma was the most common subtype of anatomical substrate present). Compared to GFR ≥60 ml/min, all-cause mortality was higher with GFR 30-60 ml/min (HR 1.61 [1.00-2.59]; aHR 1.61 [0.91-2.83]) and GFR <30 ml/min (HR 2.41 [1.06-5.48]; aHR 2.34 [0.90-6.09]) but not significant after multivariable adjustment. Follow-up echocardiographic data, available in 63%, demonstrated no difference in structural heart valve deterioration over time among groups. CONCLUSIONS: Patients with baseline renal insufficiency remain a challenging population with poor long-term outcomes despite procedural optimization with a transfemoral-first and an extremely low-contrast approach.


Assuntos
Estenose da Valva Aórtica , Insuficiência Renal Crônica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/diagnóstico , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA