Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 285
Filtrar
1.
J Orthop ; 60: 1-9, 2025 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-39345685

RESUMO

Background: With the advent of outpatient total joint arthroplasty (TJA), the days of routinely drawing postoperative labs (complete blood counts [CBCs] and metabolic panels [CMPs/BMPs]) to monitor for complications are behind us. However, there does exist a subset of at-risk patients that may benefit from diligent postoperative monitoring, though the circumstances under which labs should be ordered remains unclear and subject to surgeon discretion. A systematic review of the literature was therefore conducted to evaluate the utility of postoperative laboratory testing, approaches to targeted patient selection and associated cost-savings. Methods: The PubMed, MEDLINE, EBSCOhost, and Google Scholar electronic databases were searched on August 17, 2023, to identify all studies published since January 1, 2000, that evaluated the role of postoperative lab testing in TJA. (PROSPERO study protocol registration: CRD42023437334). Articles were included if a full-text English manuscript was available and the study assessed the utility of routine postoperative labs in TJA. 19 studies were included comprising 34,166 procedures. The mean Methodological index for Nonrandomized Studies score was 18.2 ± 1.5. Results: Abnormal postoperative lab results were common and infrequently required clinical intervention. Among several identified risk factors for patients that may benefit from postoperative laboratory monitoring, preoperative lab values proved excellent discriminators of transfusion requirement and metabolite-associated intervention. Selective testing demonstrated the ability to generate substantial cost-savings. Conclusion: Routine postoperative laboratory testing offers little clinical utility and produces unnecessary expenditures. Preoperative lab values offer the greatest predictive utility for postoperative transfusion requirement and metabolite-associated clinical intervention, with a preoperative hemoglobin threshold of 111.5 g/L offering an area under the curve (AUC) of 0.93 for predicting postoperative transfusion. Further investigations are needed for metabolic panel predictive models and should incorporate preoperative lab values. The refinement of such models can enable targeted patient selection to avoid unnecessary labs and generate substantial cost savings without compromising patient safety.

2.
Gait Posture ; 114: 62-68, 2024 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-39260073

RESUMO

INTRODUCTION: The advent of digital and mobile health innovations, especially use of wearables for passive data collection, allows remote monitoring and creates an abundance of data. For this information to be interpretable, machine learning (ML) processes are necessary. RESEARCH QUESTION: Can a machine learning model successfully identify patients expected to have low gait speed in the early recovery period following joint replacement surgery? METHODS: A commercial database from a smartphone-based care management platform passively collecting mobility data pre- and post-lower limb arthroplasty was used. We sought to create a ML model to predict gait speed recovery curves and identify patients at risk of poor gait speed outcome, a measure associated with range of motion and patient-reported outcomes. Model performance including sensitivity, specificity, precision, and accuracy were determined. Receiver operator curve (ROC) analysis was used to compare true and false positive rates. To benchmark our model, we compared threshold-based notifications based on the patient's current gait speed. RESULTS: The performance of the predictive model was significantly improved compared to baseline of threshold-based exceptions using current gait speed. The ML model currently provides 53 % precision, 88 % accuracy, 36 % sensitivity, and 95 % specificity on the held-out test set. The ROC analysis suggests good clinical performance (AUC=0.81). SIGNIFICANCE: Utilization of ML to predict gait recovery following total joint replacement is feasible and provides results with excellent specificity. This model will allow inclusion of additional data for retraining as patient populations evolve. Clinician feedback regarding notifications, including resulting actions and outcomes, can be used to further inform the model and improve clinical utility.

3.
Artigo em Inglês | MEDLINE | ID: mdl-39115540

RESUMO

BACKGROUND: Intraoperative fluoroscopy is increasingly common in orthopaedics, although recent guidelines have reduced the maximum recommended exposure to 20 mSv annually. A systematic review of the literature was conducted to comprehensively assess current adherence to exposure guidelines, identify practice settings at increased risk for exposure, and determine the best practices and personal protective equipment for ocular radiation risk mitigation. QUESTIONS/PURPOSES: In this systematic review we asked: (1) Is the annual amount of eye irradiation received by orthopaedic surgeons below the recommended limit of 20 mSv? (2) What is the effectiveness of leaded glasses in reducing the eye's exposure to radiation? (3) Which imaging setups and operative techniques reduce ocular irradiation? METHODS: PubMed, Medline, EBSCOhost, and Google Scholar were queried on September 28, 2023, to identify studies assessing intraoperative ocular radiation exposure among orthopaedic surgeons. Studies that measured radiation in or around the eye (such as the bridge of the nose or eyebrows) during orthopaedic procedures were included. Exclusion criteria were duplicate studies, studies that only estimated eye radiation based on the radiation dose recorded at parts of the body distant from the eyes, nonoriginal research, case reports, and articles without full-text English versions available. A total of 393 unique articles were retrieved, and after title, abstract, and full-text screening, 23 dosimetry studies were included, comprising 12 prospective observational studies, 7 phantom models, 1 cadaver model, 2 observational studies, and 1 randomized control trial. Risk of bias was determined via the Methodological Index for Nonrandomized Studies (MINORS) tool. Study quality was generally good to excellent, with noncomparative studies having a mean MINORS score of 14 ± 0 of 16 and comparative studies achieving a mean score of 19 ± 1 of 24, with higher scores representing better study quality. Due to extensive heterogeneity in study design, a meta-analysis was not conducted, with the results rather presented as a narrative summary of key findings. RESULTS: The vast majority of surgeons conducting a variety of orthopaedic and traumatologic procedures were not exposed to a hazardous level of eye irradiation annually, but surgeons who perform a high volume of fluoroscopy-intensive procedures may exceed guidelines. Leaded eyeglasses reduced eye radiation by about 90%, with sport wrap-around glasses offering better shielding than alternatives, although leaded glasses overall were largely underutilized. Positioning mini C-arms in the standard vertical configuration was shown to provide up to a 13-fold decrease in radiation exposure compared with inverted configuration, while standing perpendicular to the fluoroscope further reduced eye irradiation. CONCLUSION: We found that orthopaedic surgeons who perform a high volume of fluoroscopy-intensive procedures may be at risk of exceeding recommendations on annual radiation exposure, although exposure can be mitigated through various simple strategies. In particular, this analysis found that the use of sport wrap-around leaded glasses, positioning of mini-C arms in the standard vertical configuration, and standing perpendicular to the fluoroscope provide the most effective means of limiting ocular radiation exposure. As ophthalmic radiation exposure presents a potentially important occupational health hazard to orthopaedic surgeons, further investigations of radiation exposure specific to high-volume, fluoroscopy-intensive orthopaedic practices and long-term ophthalmic outcomes will help determine the extent of the potential harm posed by frequent exposure to intraoperative radiation over the span of a career. LEVEL OF EVIDENCE: Level III, therapeutic study.

4.
Artigo em Inglês | MEDLINE | ID: mdl-39212689

RESUMO

INTRODUCTION: Machine learning (ML) models may offer a novel solution to reducing postoperative complication rates and improving post-surgical outcomes after total joint arthroplasty (TJA). However, the variety of different ML models that exist paired with the increasing number of potential inputs can make the implementation of this tool challenging. Therefore, we conducted a systematic review to assess the most optimal inputs of different ML models in predicting postoperative (1) medical outcomes, (2) orthopedic outcomes, and (3) patient-reported outcome measures (PROMs) after total joint arthroplasty. METHODS: The PubMed, MEDLINE, EBSCOhost, and Google Scholar databases were utilized to identify all studies evaluating ML models predicting outcomes following TJA between January 1, 2000, and June 23, 2023 (PROSPERO study protocol registration: CRD42023437586). The mean risk of bias in non-randomized studies-of interventions score, was 13.8 ± 0.5. Our initial query yielded 656 articles, of which 25 articles aligned with our aims, examining over 20 machine learning models and 1,555,300 surgeries. The area under the curve (AUC), accuracy, inputs, and the importance of each input were reported. RESULTS: Twelve studies evaluating medical complications with 13 ML models reported AUCs ranging from 0.57 to 0.997 and accuracy between 88% and 99.98%. Key predictors included age, hyper-coagulopathy, total number of diagnoses, admission month, and malnutrition. Five studies evaluating orthopedic complications with 10 ML models reported AUCs from 0.49 to 0.93 and accuracy ranging from 92 to 97%, with age, BMI, CCI, AKSS scores, and height identified as key predictors. Ten studies evaluating PROMs comprising of 12 different ML models had an AUC ranging from 0.453 to 0.97 ranked preoperative PROMs as the post-predictive input. Overall, age was the most predictive risk factor for complications post-total joint arthroplasty (TJA). CONCLUSION: These studies demonstrate the predictive capabilities of these models for anticipating complications and outcomes. Furthermore, these studies also highlight ML models' ability to identify non-classical variables not commonly considered in addition to confirming variables known to be crucial. To advance the field, forthcoming research should adhere to established guidelines for model development and training, employ industry-standard input parameters, and subject their models to external validity assessments.

5.
J Robot Surg ; 18(1): 273, 2024 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-38949665

RESUMO

Robotic assistance for total hip arthroplasty (THA) has been demonstrated to improve accuracy of acetabular cup placement relative to manual, unassisted technique. The purpose of this investigation was to compare the accuracy and precision between a fluoroscopy-based robotic total hip arthroplasty platform (FL-RTHA) and a computerized tomography-based (CT-RTHA) platform. The study included 98 consecutive FL-RTHA and 159 CT-RTHA procedures performed via direct anterior approach (DAA). All cases were performed for a pre-operative diagnosis of osteoarthritis, avascular necrosis, or rheumatoid arthritis. Primary outcome variables included cup implantation accuracy and precision (variance). Implantation accuracy was calculated as the absolute value of the difference between pre-operative target cup angles (inclination and anteversion) and the same post-operative angles. Percentage placement in the Lewinnek safe zone was also measured for both cohorts. The FL-RTHA and CT-RTHA cohorts demonstrated a 1.2° difference in absolute values for cup inclination accuracy (4.6° ± 3.6 vs. 3.4 ± 2.7; p = 0.005), and no difference in absolute values for cup anteversion accuracy (4.7° ± 4.1 vs. 4.6 ± 3.4; p = 0.991). Cohorts demonstrated similar precision for cup inclination and anteversion placement parameters, as well as equivalent Lewinnek safe zone placement. The use of a fluoroscopy-based robotic assistance platform for primary DAA THA resulted in similar accuracy and precision of acetabular cup placement when compared to a CT-based robotic assistance system.


Assuntos
Artroplastia de Quadril , Procedimentos Cirúrgicos Robóticos , Tomografia Computadorizada por Raios X , Humanos , Artroplastia de Quadril/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Fluoroscopia/métodos , Tomografia Computadorizada por Raios X/métodos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Prótese de Quadril , Acetábulo/cirurgia , Acetábulo/diagnóstico por imagem , Cirurgia Assistida por Computador/métodos
6.
J Arthroplasty ; 39(10): 2433-2439.e1, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38857711

RESUMO

BACKGROUND: Research has suggested that glucagon-like peptide-1 receptor agonists (GLP-1-RAs) may have therapeutic effects on osteoarthritis of the hip and knee, in addition to managing diabetes and obesity. However, there is a lack of understanding regarding the association between GLP-1-RA use and the diagnosis of osteoarthritis (OA) of the hip and knee. METHODS: A collaborative network analytics platform was queried for obese diabetic (n = 1,094,198), obese nondiabetic (n = 916,235), and nonobese diabetic (n = 157,305) patients who had an index visit between 2015 and 2017. Patients who had pre-existing hip and/or knee OA were excluded. A 1:1 propensity score matching was used to balance GLP-1-RA use in stratified cohorts for age, sex, race, body mass index, and hemoglobin A1c. The primary outcomes were rates of progression to hip OA, knee OA, major joint injections, total hip arthroplasty, and total knee arthroplasty. Cox proportional hazards models determined hazard ratios (HRs) between cohorts prescribed and not prescribed GLP-1-RAs. RESULTS: All patients had a five-year follow-up. Rates of progression to hip and knee OA were higher among the GLP-1-RA users in both obese diabetic (hip HR: 1.63, 95% confidence interval [CI]: 1.46 to 1.82; knee HR: 1.52, CI: 1.41 to 1.64) and nonobese diabetic (hip HR: 1.78, CI: 1.50 to 2.10; knee HR: 1.58, CI: 1.39 to 1.80) cohorts. These diabetic cohorts received higher rates of major joint injections, though there was no difference in rates of total hip arthroplasty or total knee arthroplasty. No differences in five-year outcomes were seen when comparing obese, nondiabetic patients who were prescribed GLP-1-RAs with obese, nondiabetic patients not exposed to GLP-1-RAs. CONCLUSIONS: This five-year analysis found a greater risk of progression to hip and knee OA among obese and non-obese diabetic GLP-1-RA users. Further studies should explore GLP-1-RA effects upon glucose management, weight loss, and lower extremity arthritis development. LEVEL OF EVIDENCE: III, retrospective cohort study.


Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Receptor do Peptídeo Semelhante ao Glucagon 1 , Obesidade , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Diabetes Mellitus Tipo 2/tratamento farmacológico , Diabetes Mellitus Tipo 2/complicações , Progressão da Doença , Receptor do Peptídeo Semelhante ao Glucagon 1/agonistas , Hipoglicemiantes/uso terapêutico , Incidência , Obesidade/complicações , Osteoartrite do Quadril/cirurgia , Osteoartrite do Joelho/cirurgia , Estudos Retrospectivos
7.
Int J Med Robot ; 20(3): e2650, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38856120

RESUMO

BACKGROUND: The purpose of this study was to compare one-year patient reported outcome measures between a novel fluoroscopy-based robotic-assisted (FL-RTHA) system and an existing computerised tomography-based robotic assisted (CT-RTHA) system. METHODS: A review of 85 consecutive FL-RTHA and 125 consecutive CT-RTHA was conducted. Outcomes included one-year post-operative Veterans RAND-12 (VR-12) Physical (PCS)/Mental (MCS), Hip Disability and Osteoarthritis Outcome (HOOS) Pain/Physical Function (PS)/Joint replacement, and University of California Los Angeles (UCLA) Activity scores. RESULTS: The FL-RTHA cohort had lower pre-operative VR-12 PCS, HOOS Pain, HOOS-PS, HOOS-JR, and UCLA Activity scores compared with patients in the CT-RTHA cohort. The FL-RTHA cohort reported greater improvements in HOOS-PS scores (-41.54 vs. -36.55; p = 0.028) than the CT-RTHA cohort. Both cohorts experienced similar rates of major post-operative complications, and had similar radiographic outcomes. CONCLUSIONS: Use of the fluoroscopy-based robotic system resulted in greater improvements in HOOS-PS in one-year relative to the CT-based robotic technique.


Assuntos
Artroplastia de Quadril , Procedimentos Cirúrgicos Robóticos , Tomografia Computadorizada por Raios X , Humanos , Fluoroscopia , Procedimentos Cirúrgicos Robóticos/métodos , Feminino , Masculino , Artroplastia de Quadril/métodos , Pessoa de Meia-Idade , Idoso , Resultado do Tratamento , Estudos Retrospectivos , Articulação do Quadril/cirurgia , Articulação do Quadril/diagnóstico por imagem
8.
J Bone Joint Surg Am ; 106(14): 1256-1267, 2024 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-38753809

RESUMO

BACKGROUND: The International Consensus Meeting on Venous Thromboembolism (ICM-VTE) in 2022 proclaimed low-dose aspirin as the most effective agent in patients across all risk profiles undergoing joint arthroplasty. However, data on large patient populations assessing trends in chemoprophylactic choices and related outcomes following total knee arthroplasty (TKA) remain scant. The present study was designed to characterize the clinical use of various chemoprophylactic agents in patients undergoing TKA and to determine the efficacy of aspirin compared with other agents in patient groups stratified by VTE risk profiles. METHODS: This study utilized a national database to determine the proportion of patients undergoing TKA who received low-dose aspirin versus other chemoprophylaxis between 2012 and 2022. VTE risk profiles were determined on the basis of comorbidities established in the ICM-VTE. The odds ratios (ORs) and 95% confidence intervals (CIs) between various classes of thromboprophylaxis in patients with high and low risk of VTE were calculated. The odds of deep-vein thrombosis (DVT), pulmonary embolus (PE), bleeding events, infections, mortality, and hospitalizations were also assessed in the 90-day postoperative period for propensity-matched cohorts receiving low-dose (81 mg) aspirin only versus other prophylaxis, segregating patients by VTE risk profile. RESULTS: A total of 126,692 patients undergoing TKA across 60 health-care organizations were included. The proportion of patients receiving low-dose aspirin increased from 7.65% to 55.29% between 2012 and 2022, whereas the proportion of patients receiving other chemoprophylaxis decreased from 96.25% to 42.98%. Low-dose-aspirin-only use increased to approximately 50% in both high-risk and low-risk populations but was more likely in low-risk populations (OR, 1.17; 95% CI, 1.15 to 1.20) relative to high-risk populations. Both low-risk and high-risk patients in the low-dose-aspirin-only cohorts had decreased odds of DVT, PE, bleeding, infections, and hospitalizations compared with other prophylaxis regimens. CONCLUSIONS: The findings of the present study on a very large population of patients undergoing TKA support the recent ICM-VTE statement by showing that low-dose aspirin is a safe and effective method of prophylaxis in patients across various risk profiles. LEVEL OF EVIDENCE: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Artroplastia do Joelho , Aspirina , Tromboembolia Venosa , Humanos , Artroplastia do Joelho/efeitos adversos , Aspirina/administração & dosagem , Aspirina/uso terapêutico , Tromboembolia Venosa/prevenção & controle , Tromboembolia Venosa/etiologia , Feminino , Idoso , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/epidemiologia , Fatores de Risco
9.
J Orthop ; 55: 134-148, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38706587

RESUMO

Introduction: When indicated, Birmingham Hip Resurfacing (BHR) presents a viable alternative to total hip arthroplasty (THA), but there remain questions about the long-term outcomes of BHR. Therefore, we asked: 1) what are the long-term patient-reported outcomes and 2) survivorship rates following BHR; 3) what are the causes for revision surgery after BHR? and 4) how have these outcomes compared to THA at long-term follow-up. Methods: A query of PubMed, MEDLINE, Scopus, and Cochrane in September 2023 was performed. Articles were included if they reported BHR survivorship rates at ≥10 years. Survivorship was defined as an all-cause revision of any BHR component. This review encompasses 26 articles, totaling 13,103 hips. Mean follow-up ranged from 6.0 to 20.9 years, but each study had at least a subgroup analysis for ≥10-year follow-up. Results: Five studies compared preoperative and postoperative PROs for BHR, with four reporting improvement in at least one PRO after 10-year follow-up. Overall, survivorship rates ranged from 83% to 100% across diverse long-term timeframes, with 25 of 26 studies reporting 10-year survivorship rates greater than 87%. The primary reasons for revisions were implant loosening (22%), adverse reactions to metal debris (21.2%), and fractures of any kind (17.2%). In the six studies that compared BHR to THA, long-term survivorship was similar while BHR exhibited slightly superior activity levels. Conclusion: The findings from this study suggested favorable long-term survivorship and postoperative outcomes of BHR. In studies comparing long-term BHR and THA, survivorship was comparable, with BHR potentially providing enhanced postoperative activity levels.

10.
Ann Jt ; 9: 21, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38694811

RESUMO

Background and Objective: Due to growing numbers of primary total hip replacement (THR), the revision THR burden is also increasing. Common indications for revision are osteolysis, infection, instability, and mechanical failure of implants, which can cause acetabular bone loss. Massive acetabular bone defects and pelvic discontinuity are extremely challenging problems. Many techniques have been utilized to address bone loss while maintaining a stable revision THR. Structural allografts, cemented prosthesis, reconstruction cages, and custom triflanged implants have all been used successfully albeit with relatively high complications rates. We have tried to highlight emerging trends to utilize Custom Made Monoflange or Triflange Acetabular Components to reconstruct massive acetabular defects with favourable midterm implant survival, better functional outcomes, relatively lesser complications, and almost similar cost of prosthesis as compared to conventional reconstruction techniques. However, long-term data and study is still recommended to draw a definitive conclusion. Methods: In this narrative review article, we searched PubMed and Cochrane for studies on managing acetabular bone loss in revision THR with a focus on recent literature for mid to long-term outcomes and compared results from various studies on different reconstruction methods. Key Content and Findings: Hemispherical cementless acetabular prosthesis with supplemental screws are commonly utilized to manage mild to moderate acetabular bone loss. Recent trends have shown much interest and paradigm shift in patient specific custom triflange acetabular components (CTAC) for reconstructing massive acetabular defects and pelvic discontinuity. Studies have reported high patient satisfaction, improved patient reported daily functioning, high mid-term implant survival, similar complications, and encouraging all cause re-revision rate. However, more prospective and quality studies with larger sample sizes are needed to validate the superiority of CTACs over conventional acetabular implants. Conclusions: There is no consensus regarding the best option for reconstructing massive acetabular defects. Thorough preoperative workup and planning is an absolute requirement for successful revision THR. While most of the moderate acetabular bone loss can be managed with cementless hemispherical acetabular shells with excellent long-term outcomes, reconstructing massive acetabular bone defects in revision THR remains a challenge. Depending on the size and location of the defect, various constucts have demonstrated long-term success as discussed in this review, but complications are not negligible. CTACs provide a treatment for massive bone loss that may be otherwise difficult to achieve anatomic stability with other constructs. Although long-term data is sparse, the cost and complication rate is comparable to other reconstruction methods.

12.
J Knee Surg ; 37(10): 757-763, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38677297

RESUMO

Improvement after knee arthroplasty (KA) is often measured using patient-reported outcome measures (PROMs). However, PROMs are limited due to their subjectivity. Therefore, wearable technology is becoming commonly utilized to objectively assess physical activity and function. We assessed the correlation between PROMs and step/stair flight counts in total (TKA) and partial knee arthroplasty (PKA) patients.Analysis of a multicenter, prospective, longitudinal cohort study investigating the collection of average daily step and stair flight counts, was performed. Subjects (N = 1,844 TKA patients and N = 489 PKA patients) completed the Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS JR) and provided numerical rating scale pain scores pre- and postoperatively. Only patients who reported living in a multilevel home environment (N = 896 TKA patients and N = 258 PKA patients) were included in analysis of stair flight counts. Pearson correlation coefficients were calculated to determine correlations between variables.Among TKA patients, pain scores demonstrated a negative correlation to mean step counts at preoperative (r = -0.14, p < 0.0001) and 1-month follow-up (r = -0.14, p < 0.0001). Similar negative correlations were true for pain and stair flight counts at preoperative (r = -0.16, p < 0.0001) and 1-month follow-up (r = -0.11, p = 0.006). KOOS JR scores demonstrated weak positive correlations with mean step counts at preoperative (r = 0.19, p < 0.0001) and 1-month postoperative (r = 0.17, p < 0.0001). Similar positive correlations were true for KOOS JR scores and stair flight counts preoperatively (r = 0.13, p = 0.0002) and at 1-month postoperatively (r = 0.10, p = 0.0048). For PKA patients, correlations between pain and KOOS JR with step/stair counts demonstrated similar directionality.Given the correlation between wearable-generated data and PROMs, wearable technology may be beneficial in evaluating patient outcomes following KA. By combining subjective feedback with the objective data, health care providers can gain a holistic view of patients' progress and tailor treatment plans accordingly.


Assuntos
Artroplastia do Joelho , Medidas de Resultados Relatados pelo Paciente , Dispositivos Eletrônicos Vestíveis , Humanos , Artroplastia do Joelho/reabilitação , Artroplastia do Joelho/instrumentação , Masculino , Feminino , Idoso , Estudos Prospectivos , Pessoa de Meia-Idade , Estudos Longitudinais , Osteoartrite do Joelho/cirurgia , Recuperação de Função Fisiológica
13.
J Am Acad Orthop Surg ; 32(13): e634-e641, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38569220

RESUMO

INTRODUCTION: Although the 5-factor modified frailty index (mFI-5) has been shown to be an independent predictor of complications after primary total hip arthroplasty (THA), its predictive value has not been evaluated in the setting of hip fracture. We therefore assessed the utility of mFI-5 score as an independent predictor of morbidity and mortality in patients who underwent THA or hemiarthroplasty for femoral neck fracture. METHODS: The American College of Surgeons National Surgical Quality Improvement database was queried for all patients with femoral neck fractures treated with THA or hemiarthroplasty between 2006 and 2020. A multivariate logistic regression analysis was done using mFI-5 as a predictor while controlling for baseline demographic and clinical variables. RESULTS: In total, 45,185 patients (hemiarthroplasty: 37,645; THA: 7,540) were identified. For hemiarthroplasty patients, the mFI-5 strongly predicted risk of any complication (OR, 1.1; 95% CI, 1.1 to 1.2; P < 0.001), bleeding (OR, 1.2; 95% CI, 1.1 to 1.3; P < 0.001), and readmission (OR, 1.2; 95% CI, 1.1 to 1.3; P < 0.001). For THA patients, the mFI-5 was a strong predictor of any complication (OR, 1.2; 95% CI, 1.0 to 1.3; P = 0.023), pneumonia (OR, 1.4; 95% CI, 1.0 to 2.0; P = 0.047), and readmission (OR, 1.3; 95% CI, 1.1 to 1.6; P = 0.004). DISCUSSION: The mFI-5 is an independent predictor of morbidity and complications after hemiarthroplasty and THA for femoral neck fracture. Importantly, readmission risk was predicted by the mFI-5. The mFI-5 may present a valuable clinical tool for assessment of high-risk patients who might require additional resources and specialized care after femoral neck fracture.


Assuntos
Artroplastia de Quadril , Fraturas do Colo Femoral , Fragilidade , Hemiartroplastia , Complicações Pós-Operatórias , Humanos , Fraturas do Colo Femoral/cirurgia , Hemiartroplastia/efeitos adversos , Artroplastia de Quadril/efeitos adversos , Feminino , Masculino , Idoso , Fragilidade/complicações , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/epidemiologia , Idoso de 80 Anos ou mais , Pessoa de Meia-Idade , Resultado do Tratamento , Valor Preditivo dos Testes , Readmissão do Paciente/estatística & dados numéricos
14.
J Bone Joint Surg Am ; 106(17): 1631-1637, 2024 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-38603562

RESUMO

BACKGROUND: Understanding the trends and patterns of research funding can aid in enhancing growth and innovation in orthopaedic research. We sought to analyze financial trends in public orthopaedic surgery funding and characterize trends in private funding distribution among orthopaedic surgeons and hospitals to explore potential disparities across orthopaedic subspecialties. METHODS: We conducted a cross-sectional analysis of private and public orthopaedic research funding from 2015 to 2021 using the Centers for Medicare & Medicaid Services Open Payments database and the National Institutes of Health (NIH) RePORTER through the Blue Ridge Institute for Medical Research, respectively. Institutions receiving funds from both the NIH and the private sector were classified separately as publicly funded and privately funded. Research payment characteristics were categorized according to their respective orthopaedic fellowship subspecialties. Descriptive statistics, Wilcoxon rank-sum tests, and Mann-Kendall tests were employed. A p value of <0.05 was considered significant. RESULTS: Over the study period, $348,428,969 in private and $701,078,031 in public research payments were reported. There were 2,229 unique surgeons receiving funding at 906 different institutions. The data showed that a total of 2,154 male orthopaedic surgeons received $342,939,782 and 75 female orthopaedic surgeons received $5,489,187 from 198 different private entities. The difference in the median payment size between male and female orthopaedic surgeons was not significant. The top 1% of all practicing orthopaedic surgeons received 99% of all private funding in 2021. The top 20 publicly and top 20 privately funded institutions received 77% of the public and 37% of the private funding, respectively. Private funding was greatest (31.5%) for projects exploring adult reconstruction. CONCLUSION: While the amount of public research funding was more than double the amount of private research funding, the distribution of public research funding was concentrated in fewer institutions when compared with private research funding. This suggests the formation of orthopaedic centers of excellence (CoEs), which are programs that have high concentrations of talent and resources. Furthermore, the similar median payment by gender is indicative of equitable payment size. In the future, orthopaedic funding should follow a distribution model that aligns with the existing approach, giving priority to a nondiscriminatory stance regarding gender, and allocate funds toward CoEs. CLINICAL RELEVANCE: Securing research funding is vital for driving innovation in orthopaedic surgery, which is crucial for enhancing clinical interventions. Thus, understanding the patterns and distribution of research funding can help orthopaedic surgeons tailor their future projects to better align with current funding trends, thereby increasing the likelihood of securing support for their work.


Assuntos
Pesquisa Biomédica , Ortopedia , Apoio à Pesquisa como Assunto , Humanos , Estados Unidos , Estudos Transversais , Pesquisa Biomédica/economia , Masculino , Feminino , Ortopedia/economia , Apoio à Pesquisa como Assunto/economia , Apoio à Pesquisa como Assunto/estatística & dados numéricos , Apoio à Pesquisa como Assunto/tendências , Setor Privado/economia , Financiamento Governamental/economia , Financiamento Governamental/estatística & dados numéricos , Financiamento Governamental/tendências , Cirurgiões Ortopédicos/economia , Cirurgiões Ortopédicos/estatística & dados numéricos , Setor Público/economia , Procedimentos Ortopédicos/economia , Procedimentos Ortopédicos/estatística & dados numéricos
15.
Arthroplasty ; 6(1): 16, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38576001

RESUMO

INTRODUCTION: Mental and psychiatric status continue to be underscreened prior to total joint arthroplasty (TJA). Research on the role of resilience as a psychiatric factor affecting TJA outcomes remains limited. Therefore, our systematic review sought to evaluate the impact of patient resilience in TJA. METHODS: A systematic review of the literature from the Pubmed, MEDLINE, EBSCOhost, and Google Scholar online databases was performed in abidance with Preferred Reporting Items for Systematic Review and Meta-Analyses (PRISMA) guidelines. Studies reporting on outcomes following primary total hip arthroplasty (THA) and/or total knee arthroplasty (TKA) segregated by patient resilience were included. Case reports, reviews, meta-analyses, and conference abstracts were excluded. Primary outcomes of interest included patient-reported outcomes (PROs), surgical outcomes, and postoperative opioid consumption. RESULTS: Twelve articles were included reporting on a total of 1,577 TJAs. There was a strong agreement that the Patient Reported Outcomes Measurement Information System (PROMIS)-Physical Health and Mental Health components were strongly predicted by patient resilience. However, there was inconclusive evidence regarding the impact of resilience on UCLA Activity Scales (UCLA) and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) outcomes as well as postoperative hip and knee function. Similarly, conflicting evidence was presented regarding the effect of resilience on length of stay (LOS). Greater resilience was associated with reduced opioid usage in the immediate inpatient postoperative period. However, resilience had no significant effect on opioid requirements in the postoperative outpatient follow-up time frame. CONCLUSION: The present analysis demonstrated mixed, inconclusive evidence regarding the impact of resilience on postoperative outcomes. The paucity of research evaluating this relationship warrants further investigation, examining both short and long-term outcomes. Due to the limited literature evaluating resilience as a predictor of outcomes following TJA, we cannot definitively rule out resilience as a valuable metric and must further examine its utility as a preoperative screening tool. LEVEL OF EVIDENCE: III.

16.
J Orthop ; 53: 140-146, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38601894

RESUMO

Introduction: Although gluteal tears have been observed in a substantial percentage of total hip arthroplasty (THA) patients and hip osteoarthritis (OA) has been shown to alter the function of the gluteal muscles, the association between gluteal tears and hip OA has not been characterized. Therefore, we evaluated (1) the overlap between hip OA and gluteal tears, (2) the relative risks of gluteal tears in patients who have hip OA, and (3) gluteal tear-free survival after diagnosis or treatment for hip osteoarthritis. Methods: This retrospective study sourced data from TriNetX, a research network that aggregates data from over 92 million patients. Relative risks for gluteal tears were calculated for known risk factors for gluteal tears, age ≥45 years, female sex, and obesity, as well as for hip OA, hip injections, and THA. A subgroup analysis was performed utilizing a Cox proportional hazard model for patients who were diagnosed with hip OA, received a hip injection, or underwent THA in 2015 to assess gluteal tear-free survival over a 9-year timeframe. Results: There was a large degree of overlap between patients with hip OA and gluteal tears, as 17.9% of patients with hip OA and 27.5% of patients with a gluteal tear also had the other pathology. Hip OA was associated with a markedly increased risk of a gluteal tear compared to healthy controls (Relative risk: 26.75, 95% CI: 26.64-26.86). Upon controlling for the established risk factors of gluteal tears, patients with hip OA had a markedly more likely to subsequently be diagnosed with an abductor tear (Hazard ratio: 12.46, 95% CI: 11.75-13.22). Conclusion: Overall, these findings suggest a strong association between hip OA and the development of gluteal tears, in which further investigation is merited to determine the biomechanical pathophysiology underlying this potential relationship to inform prevention and treatment strategies.

17.
J Robot Surg ; 18(1): 160, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38578350

RESUMO

Robotic assisted (RA) total hip arthroplasty (THA) offers improved acetabular component placement and radiographic outcomes, but inconsistent assessment methods of its learning curves render the evaluation of adopting novel platforms challenging. Therefore, we conducted a systematic review to assess the learning curve associated with RA-THA, both tracking a surgeon's performance across initial cases and comparing their performance to manual THA (M-THA). PubMed, MEDLINE, EBSCOhost, and Google Scholar were searched on June 16, 2023, to identify studies published between January 1, 2000 and June 16, 2023 (PROSPERO registration: CRD42023437339). The query yielded 655 unique articles, which were screened for eligibility. The final analysis included 11 articles, evaluating 1351 THA procedures. Risk of bias was assessed via the Methodological Index for Nonrandomized Studies (MINORS) tool. The mean MINORS score was 21.3 ± 0.9. RA-THA provided immediate improvements in acetabular component placement accuracy and radiographic outcomes compared to M-THA, with little to no experience required to achieve peak proficiency. A modest learning curve (12-17 cases) was associated with operative time, which was elevated compared to M-THA (+ 9-13 min). RA-THA offers immediate advantages to M-THA for component placement accuracy and radiographic outcomes. Surgeons should expect to experience increased operative times, which become less pronounced or equivalent to M-THA after a modest caseload.


Assuntos
Artroplastia de Quadril , Procedimentos Cirúrgicos Robóticos , Cirurgia Assistida por Computador , Humanos , Artroplastia de Quadril/métodos , Curva de Aprendizado , Procedimentos Cirúrgicos Robóticos/métodos , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Cirurgia Assistida por Computador/métodos
18.
Arch Orthop Trauma Surg ; 144(5): 1977-1987, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38554209

RESUMO

INTRODUCTION: Prior studies investigating the racial and ethnic representation of orthopedic trial participants have found low rates of reporting, but these studies are dated due to the passing of the National Institutes of Health Final Rule in 2017 requiring the reporting of racial and ethnic data among clinical trials. Therefore, we evaluated the representativeness of orthopedic clinical trials before and after the Final Rule. METHODS: A cross-sectional survey of orthopaedic clinical trials registered at ClinicalTrials.gov between October 1, 2007 and May 20, 2023 was conducted. After identifying and screening 23,752 clinical trials, 1564 trials were included in the analysis. Trials started before the implementation of the Final Rule on January 18, 2017 were grouped and compared to trials that began after. Odds ratios (OR) were utilized to identify trial characteristics associated with reporting race/ethnicity data. One-proportion z tests compared the representation of each racial and ethnic category to the 2020 United States Census. RESULTS: In total, 34% (544 of 1564) of orthopedic clinical trials evaluated reported the race of participants, while 28% (438 of 1564) reported ethnicity. Trials registered after the Final Rule were more likely to report racial (OR: 5.15, 95%CI: 3.72-7.13, p < 0.001) and ethnic (OR: 3.23, 95%CI: 2.41-4.33, p < 0.001) representation of participants. Compared with the distribution of race and ethnicity reported by the United States 2020 Census, orthopedic trials had 16.6% more White participants (95% CI 16.4%, 16.8%; p < 0.001), 3.2% fewer Black participants (95%CI 3.1%, 3.3%; p < 0.001), and 5.7% fewer Hispanic/Latino participants (95%CI 5.2%, 6.2%; p < 0.001). Trials with enrollment sizes over 100 participants were also more likely to report race and ethnicity, with odds increasing with increased sample size. CONCLUSIONS: The Final Rule marginally improved the reporting of race and ethnicity in orthopedic clinical trials, and underrepresentation of Black or African American, Multiracial, and Hispanic populations persists. LEVEL OF EVIDENCE: III.


Assuntos
Ensaios Clínicos como Assunto , Procedimentos Ortopédicos , Humanos , Ensaios Clínicos como Assunto/estatística & dados numéricos , Estudos Transversais , Etnicidade/estatística & dados numéricos , Procedimentos Ortopédicos/estatística & dados numéricos , Ortopedia/estatística & dados numéricos , Grupos Raciais/estatística & dados numéricos , Estados Unidos , Negro ou Afro-Americano , Hispânico ou Latino , Brancos
19.
J Orthop ; 53: 125-132, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38515529

RESUMO

Introduction: Robotic-assisted (RA) and computer-navigated (CN) total hip arthroplasty (THA) have been demonstrated to improve component placement accuracy compared to manual THA (mTHA) for primary osteoarthritis. As hip dysplasia presents several additional challenges in component placement accuracy and leg length discrepancy (LLD) correction during THA, a systematic review was conducted to evaluate whether utilizing these platforms may be associated with superior outcomes over mTHA in patients who have hip dysplasia. Methods: PubMed, Medline, EBSCOhost, and Google Scholar were searched on September 13, 2023 to identify comparative studies published after January 1, 2000 that evaluated outcomes of RA-THA or CN-THA in patients who have hip dysplasia. The query yielded 197 unique articles, which were screened for alignment with the study aims. After screening, 10 studies fulfilled all inclusion criteria, comprising 946 patients. Risk of bias was evaluated via the Methodological Index for Nonrandomized Studies tool, and the mean score was 21.2 ± 1.5. Results: Both RA-THA and CN-THA were not associated with improved acetabular anteversion and inclination when evaluating Crowe I-IV types altogether compared to mTHA, but studies reported improved accuracy for each Crowe I and II cases when assessed individually. While studies reporting acetabular cup placement within the Lewinnek and Callanan safe zones consistently found higher odds of accurate positioning for RA-THA versus mTHA, accuracy in achieving targeted center of rotation was mixed. Also, studies reported no difference in LLD restoration for RA-THA and CN-THA compared to mTHA. While operative time may be increased when utilizing these platforms, they may also expedite specific sequences, offsetting most of the increase in operative time. Conclusion: This review highlights the advantages of RA-THA and CN-THA for patients who have DDH, particularly when treating Crowe I and II types as superior radiographic outcomes were achieved with these intraoperative technologies. However, there remains a need for studies to investigate whether this results in patient-reported outcome measures.

20.
J Robot Surg ; 18(1): 104, 2024 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-38430388

RESUMO

PURPOSE: Computer-navigated (CN) total hip arthroplasty (THA) offers improved acetabular component placement and radiographic outcomes, but inconsistent assessment methods of its learning curves render the evaluation of adopting a novel platform challenging. Therefore, we conducted a systematic review to assess the learning curve associated with CN-THA, both tracking a surgeon's performance across initial cases and comparing their performance to manual THA (M-THA). METHODS: A search was conducted using PubMed, MEDLINE, EBSCOhost, and Google Scholar on June 16, 2023 to find research articles published after January 1, 2000 (PROSPERO registration: CRD4202339403) that investigated the learning curve associated with CN-THA. 655 distinct articles were retrieved and subsequently screened for eligibility. In the final analysis, nine publications totaling 847 THAs were evaluated. The Methodological Index for Nonrandomized Studies (MINORS) tool was utilized to evaluate the potential for bias, with the mean MINORS score of 21.3 ± 1.2. RESULTS: CN-THA showed early advantages to M-THA for component placement accuracy and radiographic outcomes but longer operative times (+ 3- 20 min). There was a learning curve required to achieve peak proficiency in these metrics, though mixed methodologies made the required caseload unclear. CONCLUSIONS: CN-THA offers immediate advantages to M-THA for component placement accuracy and radiographic outcomes, though CN-THA's advantages become more pronounced with experience. Surgeons should anticipate longer operative times during the learning curve for CN-THA, which lessen following a modest caseload. A more thorough evaluation of novel computer-navigated technologies would be enhanced by adopting a more uniform method of defining learning curves for outcomes of interest. Registration PROSPERO registration of the study protocol: CRD42023394031, 27 June 2023.


Assuntos
Artroplastia de Quadril , Procedimentos Cirúrgicos Robóticos , Humanos , Artroplastia de Quadril/métodos , Curva de Aprendizado , Procedimentos Cirúrgicos Robóticos/métodos , Resultado do Tratamento , Computadores
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA