1.
J Appl Crystallogr ; 46(Pt 4): 1031-1037, 2013 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-24046504

RESUMO

A novel 2π detector geometry for small-angle neutron scattering (SANS) applications is presented and its theoretical performance evaluated. Such a novel geometry is ideally suited for a SANS instrument at the European Spallation Source (ESS). Motivated by the low availability and high price of 3He, the new concept utilizes gaseous detectors with 10B as the neutron converter. The shape of the detector is inspired by an optimization process based on the properties of the conversion material. Advantages over the detector geometry traditionally used on SANS instruments are discussed. The angular and time resolutions of the proposed detector concept are shown to satisfy the requirements of the particular SANS instrument.

2.
J Appl Crystallogr ; 46(Pt 5): 1528, 2013 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-24068845

RESUMO

Errors in the paper by Kanaki, Jackson, Hall-Wilton, Piscitelli, Kirstein & Andersen [J. Appl. Cryst. (2013), 46, 1031-1037] are corrected.[This corrects the article DOI: 10.1107/S0021889813011862.].