Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
J Refract Surg ; 40(6): e420-e434, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38848055

RESUMO

PURPOSE: To discuss factors influencing corneal aberrations that might influence the optical quality after intraocular lens (IOL) implantation. METHODS: PubMed and Scopus were the main resources used to search the medical literature. An extensive search was performed to identify relevant articles concerning factors influencing the level of corneal aberrations as of August 27, 2023. The following keywords were used in various combinations: corneal, aberrations, defocus, astigmatism, spherical aberration, coma, trefoil, quadrafoil, intraocular lens, and IOL. RESULTS: Conclusive evidence is lacking regarding the correlation between age and changes in corneal aberrations. Patients with astigmatism have greater corneal higher-order aberrations than those with minimal astigmatism, particularly concerning trefoil and coma. Increased levels of corneal higher-order aberrations are noted following contact lens wear, in patients with dry eye disease, and with pterygium. Increased higher-order aberrations have been reported following corneal refractive surgery and for 3 months following trabeculectomy; regarding intraocular lens surgery, the results remain controversial. CONCLUSIONS: Several factors influence the level of corneal higher-order aberrations. Multifocal and extended depth-of-focus IOLs can share similarities in their optical properties, and the main difference arises in their design and performance with respect to spherical aberration. Preoperative evaluation is critical for proper IOL choice, particularly in corneas with risk of high levels of aberrations. [J Refract Surg. 2024;40(6):e420-e434.].


Assuntos
Aberrações de Frente de Onda da Córnea , Implante de Lente Intraocular , Refração Ocular , Acuidade Visual , Humanos , Aberrações de Frente de Onda da Córnea/fisiopatologia , Aberrações de Frente de Onda da Córnea/etiologia , Fatores de Risco , Acuidade Visual/fisiologia , Refração Ocular/fisiologia , Lentes Intraoculares Multifocais , Percepção de Profundidade/fisiologia , Topografia da Córnea , Córnea/fisiopatologia
3.
Am J Ophthalmol ; 266: 135-143, 2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38692502

RESUMO

PURPOSE: To assess the effect of blue-light filtering (BLF) intraocular lenses (IOLs) on the development and progression of macular atrophy (MA) in eyes with neovascular age-related macular degeneration (nAMD). DESIGN: Retrospective, clinical cohort study. METHODS: The study included patients with nAMD with anti-vascular endothelial growth factor (VEGF) injections who underwent uneventful cataract surgery between 2007 and 2018 with follow-up until June 2023. Subsequent MA rates were compared between subjects who received a BLF IOL or a non-BLF IOL. All optical coherence tomography scans were manually reviewed in a masked manner regarding patient baseline variables and IOL status by an experienced research technician. By using Heidelberg software, the area of MA was manually evaluated and calculated (mm2) by the program. The overall risk of developing new-onset MA and the effect of IOL type on disease progression were assessed. Death was included as a censoring event. RESULTS: Included were 373 eyes of 373 patients (mean age, 78.6 ± 6.7 years at surgery; 67.4% were female). BLF IOLs were implanted in 206 eyes, and non-BLF IOLs were implanted in 167 eyes with comparable follow-up times (3164 ± 1420 days vs 3180 ± 1403 days, respectively, P = .908) and other baseline parameters (age, gender, corrected distance visual acuity, macular thickness, cumulative number of anti-VEGF injections). Nine preexisting and 77 new-onset MA cases were detected, with similar distribution between BLF and non-BLF eyes (P = .598 and P = .399, respectively). Both univariate Kaplan-Meier (P = .366) and multivariate Cox regression analyses adjusted for age and gender showed that BLF-IOLs were comparable to non-BLF IOLs regarding hazard for new-onset MA (hazard ratio [HR], 1.236; 95% CI, 0.784-1.949; P = .363). Final MA area at the last visit was 5.14 ± 4.71 mm2 for BLF IOLs and 8.56 ± 9.17 mm2 for non-BLF IOLs (P = .028), with the mean annual MA area increase of 0.78 ± 0.84 mm2 and 1.26 ± 1.32 mm2, respectively (P = .042). CONCLUSIONS: BLF IOLs did not show added benefit over non-BLF IOLs in terms of MA-free survival but were associated with less progression over time in a cohort of patients with nAMD.

4.
Int Ophthalmol ; 44(1): 185, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38634955

RESUMO

PURPOSE: The aim of the study was to analyze the time-savings associated with introduction of Streamlight™ (Alcon Laboratories, Fort Worth, TX, USA) transepithelial photorefractive keratectomy (PRK) in surface corneal ablations. METHODS: All refractive surgeries were performed using the Alcon WaveLight® EX500 at the ArtLife Clinic, Gdansk, Poland. The study included patients treated for refractive errors with transepithelial PRK between April 2019 and October 2021, who were matched with patients treated with alcohol-assisted PRK during the same period. Only results for the left eye were analyzed. RESULTS: One-hundred-five patients underwent transepithelial PRK (age 33.42 ± 8.67 years) and were matched with 105 patients that underwent alcohol-assisted PRK (age 33.05 ± 10.16 years; p = 0.11). The mean preoperative spherical equivalent refraction was - 2.04 ± 2.28 D, and - 1.9 ± 1.71 D for the transepithelial and alcohol-assisted PRK group, respectively (p = 0.20). The total surgery time was non-significantly shorter in transepithelial PRK (349.46 ± 47.83 s) than in alcohol-assisted PRK (354.93 ± 137.63 s; p = 0.7); however, the variance of surgical time was significantly lower in transepithelial PRK (p < 0.001). The laser treatment duration was greater in transepithelial PRK (41.78 ± 17.2 s) than in alcohol-assisted PRK (8.48 ± 6.12 s; p < 0.001), and so was the number of breaks during the laser treatment (0.95 ± 0.63 vs. 0.53 ± 0.88, respectively; p < 0.001). CONCLUSION: The introduction of transepithelial PRK did not bring significant time-associated savings into the refractive surgery suite.


Assuntos
Oftalmologia , Ceratectomia Fotorrefrativa , Erros de Refração , Procedimentos Cirúrgicos Refrativos , Humanos , Adulto Jovem , Adulto , Olho , Etanol
5.
Int Ophthalmol ; 44(1): 193, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38653918

RESUMO

PURPOSE: This study evaluated the tear film stability in patients with symptoms of dry eye after installation of dual polymer hydroxypropyl guar/sodium hyaluronate (DPHG/SH) vs single polymer SH. METHODS: Patients with recently diagnosed mild to moderate dry eye disease (OSDI score 23-32 points) were included. For each patient, the right eye was randomized to receive DPHG/SH or 0.15% SH. Just after the administration of the drop to the right eye, the fellow eye received the other eye drop. The first non-invasive Keratograph first break-up time (NIKBUT), average NIKBUT and tear meniscus height (TMH) were measured before administration of the eye drops, at 1-min, 15 min, 30 min, 60 min, 90 min, and 120 min after instillation. RESULTS: A total of 29 patients aged 22.8 ± 2.2 years participated in the study (21 women). No differences between the eye receiving DPHG/SH and single polymer SH were observed for the first NIKBUT (p = 0.45) and average NIKBUT (p = 0.24) variables at any time point. Both DPHG/SH and single polymer SH increased the TMH (p of time effect < 0.001), but with no difference between groups (p = 0.95). CONCLUSION: Both DPHG/SH and single polymer SH solutions provide lubrication of the eye surface, however, with no difference in NIKBUT and TMH evaluations for up to two hours following administration.


Assuntos
Síndromes do Olho Seco , Ácido Hialurônico , Soluções Oftálmicas , Lágrimas , Humanos , Síndromes do Olho Seco/tratamento farmacológico , Síndromes do Olho Seco/diagnóstico , Feminino , Ácido Hialurônico/administração & dosagem , Masculino , Soluções Oftálmicas/administração & dosagem , Adulto Jovem , Adulto , Polissacarídeos/administração & dosagem , Polímeros , Viscossuplementos/administração & dosagem , Estudos Prospectivos
6.
BMC Ophthalmol ; 24(1): 130, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38528448

RESUMO

INTRODUCTION: Photoscreeners have been shown to provide excellent measurements of the refractive error. However, whether they could be used for assessing cycloplegic refraction has not been examied. This study aimed to evaluate the agreement between cycloplegic and non-cycloplegic measurements obtained using a photoscreener and stationary autorefractor, respectively. METHODS: This study included all patients undergoing routine ophthalmic examination at the Hygeia Clinic (Poland) from June to July 2022. Each patient underwent non-cycloplegic and cycloplegic refraction assessments using the 2WIN photoscreener (Adaptica SRL, Padova, Italy) and an ARK-1 stationary autorefractor ARK-1 (Nidek Co Ltd., Tokyo, Japan), respectively. Each pair of assessments was conducted in random order, and all values were determined at a vertical distance of 12 mm. The agreement between cycloplegic and non-cycloplegic measurements was assessed using paired t-tests, Bland-Altman and ABCD ellipsoids. RESULTS: This analysis included 82 patients, of which 52 were female. Their mean age was 34.39 ± 13.13 years. The non-cycloplegic spherical equivalent (SE) did not differ significantly between the 2WIN (- 1.22 ± 2.45) and ARK-1 (- 1.19 ± 2.96) devices (p = 0.580). However, the cycloplegic SE values demonstrated more negative values with the 2WIN device (- 1.13 ± 2.19) than with the ARK-1 device (- 0.75 ± 3.03; p = 0.007). The non-cycloplegic and cycloplegic measurements were strongly correlated between the devices (r = 0.9473 and 0.9411, respectively). However, the correlation between their cycloplegic shifts in SE was low (r = 0.2645). Ellipsoid refraction aligned better non-cycloplegic (ARK-1 = 1.00; 2WIN = 1.74) than with cycloplegic refraction (ARK-1 = 1.43; 2WIN = 1.90). CONCLUSION: While the cycloplegic measurements obtained with the 2WIN photoscreener were strongly correlated with those obtained with the ARK-1 stationary autorefractor for most of the analyzed parameters, they should not be considered interchangeable.


Assuntos
Midriáticos , Erros de Refração , Humanos , Feminino , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Masculino , Testes Visuais , Refração Ocular , Erros de Refração/diagnóstico , Japão
7.
Eye Contact Lens ; 50(3): 138-144, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38181218

RESUMO

OBJECTIVE: To compare the outcomes of corneal tomography obtained with an anterior-to-posterior segment optical coherence tomography device (Revo, Optopol Technologies Sp. z o.o.) and a rotating Scheimpflug camera (Pentacam AXL, Oculus Optikgeräte, Wetzlar, Germany). METHODS: In healthy subjects, agreement in stereometric parameters commonly used in cataract and refractive surgery was assessed. Comparison between the devices was performed using correlation coefficients, the Bland-Altman method, and a paired t test. RESULTS: Results of right eyes of 78 patients (47 women) aged 25.24±5.56 years were analyzed. The flat and steep anterior keratometry values were significantly higher for Revo than Pentacam (43.65±1.58 D vs. 42.99±1.47 D; P = 0.000, and 44.53±1.57 D vs. 43.82±1.49 D; P =0.000, respectively) and showed excellent correlation ( r =0.978 and 0.974, respectively). The results for maximal keratometry manifested a higher difference (45.89±1.69 D vs. 44.27±1.51 D for Revo and Pentacam, P =0.000) but were also strongly correlated ( r =0.871). Revo showed significantly lower corneal thickness values than Pentacam, both for apex pachymetry (535.54±32.45 vs. 550.74±31.55 µm; P =0.000) and for thinnest pachymetry (522.58±32.16 vs. 547.25±31.95 µm; P =0.000). The correlation coefficients for anterior and posterior corneal elevation at the thinnest point showed weak positive correlation ( r =0.179 and 0.185), while the correlation for corneal asphericity was moderate ( r =0.317). CONCLUSIONS: There was a significant difference between keratometric values obtained with Revo and the Pentacam AXL, although the measurements showed excellent correlation. Similar results were found for corneal thickness measurements, but not for corneal surface elevation and corneal asphericity.


Assuntos
Córnea , Tomografia de Coerência Óptica , Humanos , Feminino , Tomografia de Coerência Óptica/métodos , Reprodutibilidade dos Testes , Estudos Prospectivos , Córnea/diagnóstico por imagem , Paquimetria Corneana , Topografia da Córnea/métodos
8.
J Cataract Refract Surg ; 50(1): 84-94, 2024 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-38133648

RESUMO

The pinhole effect is commonly used to discriminate uncorrected refractive error from ocular diseases. A small aperture limits the width of light beams entering the eye, thus increasing the depth of focus. The pinhole effect has also been used in spectacles, contact lenses, corneal inlays, and intraocular lenses (IOLs) to improve reading by compensating for loss of accommodative function. Pinhole spectacles improve near visual acuity, but reduce reading speed, increase interblink interval, and decrease tear break-up time. For contact lenses and IOLs, pinhole devices are usually used in the nondominant eye, which allow compensation of various refractive errors and decrease spectacle dependence. Pinhole corneal inlays are implanted during laser in situ keratomileusis or as a separate procedure. Pinhole IOLs are gaining popularity, particularly as they do not bring a risk of a local inflammatory reaction as corneal inlays do. Disadvantages of using the pinhole effect include high susceptibility to decentration, decrease in retinal luminance levels, and difficulties in performing fundus examinations or surgery in eyes with implanted devices. There are also concerns regarding perceptive issues with different retinal illuminances in the 2 eyes (the Pulfrich effect).


Assuntos
Lentes de Contato , Lentes Intraoculares , Erros de Refração , Humanos , Visão Ocular , Acuidade Visual , Acomodação Ocular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA