Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Arq Bras Oftalmol ; 81(1): 63-65, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29538597

RESUMO

This study reports the first case of intravitreal angiostrongyliasis in South America treated with posterior worm removal via pars plana vitrectomy. This was a retrospective, observational case study. Data from medical charts, wide-field digital imaging, ocular ultrasound, and visual evoked potential studies were reviewed. A 20-month-old boy presented with eosinophilic meningitis and right eye exotropia. Polymerase chain reaction analysis of the cerebrospinal fluid showed a positive result for Angiostrongylus cantonensis. Fundus examination revealed a pale optic disc, subretinal tracks, vitreous opacities, peripheral tractional retinal detachment, and a dead worm in the vitreous cavity. The patient underwent pars plana vitrectomy with worm removal. This case report illustrates the first case of intravitreal angiostrongyliasis in South America, possibly related to the uncontrolled spread of an exotic invasive species of snail.


Assuntos
Angiostrongylus cantonensis/isolamento & purificação , Infecções por Strongylida/cirurgia , Vitrectomia/métodos , Corpo Vítreo/parasitologia , Animais , Brasil , Humanos , Lactente , Masculino , Descolamento Retiniano/diagnóstico por imagem , Descolamento Retiniano/parasitologia , Infecções por Strongylida/diagnóstico por imagem , Resultado do Tratamento , Ultrassonografia , Corpo Vítreo/diagnóstico por imagem
2.
Arq. bras. oftalmol ; 81(1): 63-65, Jan.-Feb. 2018. graf
Artigo em Inglês | LILACS | ID: biblio-888183

RESUMO

ABSTRACT This study reports the first case of intravitreal angiostrongyliasis in South America treated with posterior worm removal via pars plana vitrectomy. This was a retrospective, observational case study. Data from medical charts, wide-field digital imaging, ocular ultrasound, and visual evoked potential studies were reviewed. A 20-month-old boy presented with eosinophilic meningitis and right eye exotropia. Polymerase chain reaction analysis of the cerebrospinal fluid showed a positive result for Angiostrongylus cantonensis. Fundus examination revealed a pale optic disc, subretinal tracks, vitreous opacities, peripheral tractional retinal detachment, and a dead worm in the vitreous cavity. The patient underwent pars plana vitrectomy with worm removal. This case report illustrates the first case of intravitreal angiostrongyliasis in South America, possibly related to the uncontrolled spread of an exotic invasive species of snail.


RESUMO O objetivo deste estudo foi relatar o primeiro caso na América do Sul de angiostrongilíase intravítrea tratada com vitrectomia posterior via pars plana e remoção do verme. Este foi um relato de caso observacional. O prontuário médico, sistema de imagem digital de campo amplo, ultrassonografia ocular, e potenciais evocados visuais foram revistos. Um menino de 1 ano e 8 meses de idade manifestou meningite eosinofílica e exotropia olho direito. A análise de PCR do liquor foi positiva para Angiostrongylus cantonensis. O exame de fundo de olho revelou disco óptico pálido, faixas sub-retinianas, opacidades vítreas, descolamento de retina tracional periférico e um verme morto no vítreo. O paciente foi submetido a vitrectomia posterior via pars plana com a remoção do verme. Concluindo, este é o primeiro relato de caso de angiostrongilíase intravítrea na América do Sul, possivelmente relacionado com a disseminação de uma espécie de lesma exótica neste continente.


Assuntos
Humanos , Animais , Masculino , Lactente , Vitrectomia/métodos , Corpo Vítreo/parasitologia , Infecções por Strongylida/cirurgia , Angiostrongylus cantonensis/isolamento & purificação , Corpo Vítreo/diagnóstico por imagem , Brasil , Descolamento Retiniano/parasitologia , Descolamento Retiniano/diagnóstico por imagem , Ultrassonografia , Resultado do Tratamento , Infecções por Strongylida/diagnóstico por imagem
3.
Arq Bras Oftalmol ; 80(2): 78-83, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28591278

RESUMO

PURPOSE:: To compare measurements of lesions clinically diagnosed as choroidal nevi using spectral domain optical coherence tomography (SD-OCT) and 10- and 20-MHz ultrasound (US). METHODS:: This prospective study, which was conducted between May 2011 and December 2011, evaluated eyes diagnosed with choroidal nevus via photographic documentation using 10- or 20-MHz A- and B-mode US (experienced examiner using both the transpalpebral technique and direct contact) or SD-OCT in the enhanced depth imaging mode (performed by a different examiner blinded to the US results). Anteroposterior (AP) and transverse (T) US sections corresponded to sections adjusted perpendicularly on SD-OCT. RESULTS:: We evaluated 14 eyes from 12 patients (six males, mean patient age= 64.5 years) diagnosed with choroidal nevus. The choroidal nevi of all samples had a melanocytic profile. Moreover, eight nevi were located at the equator, five nevi were located in the posterior pole (peripapillary in one sample), and one nevus shifted from the equator to the periphery. On SD-OCT, the maximum measurable dimension was 9 mm. The lesions in the posterior pole were easier to evaluate, and image acquisition of lesions located more peripherally was possible depending on patient cooperation. The accurate assessment of height was difficult. Baseline dimensions on 10- and 20-MHz US were larger than those determined via OCT. No significant differences in height were observed between US and SD-OCT. All parameters were statistically similar between 10- and 20-MHz US measurements. CONCLUSIONS:: No significant difference in the AP and T diameters was observed between 10- and 20-MHz US measurements; however, these measurements (AP and T) were significantly higher than those obtained using OCT. No significant differences in height were observed among the techniques adopted.


Assuntos
Neoplasias da Coroide/diagnóstico por imagem , Precisão da Medição Dimensional , Nevo Pigmentado/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Coroide/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Nevo Pigmentado/patologia , Tamanho do Órgão , Estudos Prospectivos , Tomografia de Coerência Óptica/métodos , Ultrassonografia/métodos
4.
Arq. bras. oftalmol ; 80(2): 78-83, Mar.-Apr. 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-838791

RESUMO

ABSTRACT Purpose: To compare measurements of lesions clinically diagnosed as choroidal nevi using spectral domain optical coherence tomography (SD-OCT) and 10- and 20-MHz ultrasound (US). Methods: This prospective study, which was conducted between May 2011 and December 2011, evaluated eyes diagnosed with choroidal nevus via photographic documentation using 10- or 20-MHz A- and B-mode US (experienced examiner using both the transpalpebral technique and direct contact) or SD-OCT in the enhanced depth imaging mode (performed by a different examiner blinded to the US results). Anteroposterior (AP) and transverse (T) US sections corresponded to sections adjusted perpendicularly on SD-OCT. Results: We evaluated 14 eyes from 12 patients (six males, mean patient age= 64.5 years) diagnosed with choroidal nevus. The choroidal nevi of all samples had a melanocytic profile. Moreover, eight nevi were located at the equator, five nevi were located in the posterior pole (peripapillary in one sample), and one nevus shifted from the equator to the periphery. On SD-OCT, the maximum measurable dimension was 9 mm. The lesions in the posterior pole were easier to evaluate, and image acquisition of lesions located more peripherally was possible depending on patient cooperation. The accurate assessment of height was difficult. Baseline dimensions on 10- and 20-MHz US were larger than those determined via OCT. No significant differences in height were observed between US and SD-OCT. All parameters were statistically similar between 10- and 20-MHz US measurements. Conclusions: No significant difference in the AP and T diameters was observed between 10- and 20-MHz US measurements; however, these measurements (AP and T) were significantly higher than those obtained using OCT. No significant differences in height were observed among the techniques adopted.


RESUMO Objetivo: Comparar as medidas obtidas de lesões diagnosticadas clinicamente como nevus de coroide através da tomografia de coerência óptica de domínio espectral (Spectralis, Heidelberg Engineering, Inc.), ultrassonografia com 10 MHz e de 20 MHz. Métodos: Estudo prospectivo realizado entre maio e dezembro de 2011, avaliou olhos com diagnóstico de nevus de coroide, utilizando documentação fotográfica, ultrassonografia com transdutor 10-MHz e 20-MHz A- e B-mode e SD-OCT em modo de EDI, por um examinador diferente para cada técnica. Os cortes realizados perpendiculares entre si, correspondentes ao corte ântero-posterior e latero-lateral à ultrassonografia. Resultados: Foram avaliados 14 olhos de 12 pacientes (6 do sexo masculino), com média de idade média de 64,5 anos. Todos os nevus tinham um perfil melanocítico. Observou-se 8 nevus no equador, 5 no polo posterior (peripapilar em uma amostra), e 1 deslocado a partir do equador para a periferia. Em SD-OCT, a dimensão máxima mensurável foi de 9 mm. As lesões no polo posterior eram mais fáceis de avaliar e aquisição de imagens de lesões mais periféricas era possível, dependendo da colaboração do paciente. A avaliação precisa da altura era difícil. As dimensões usando transdutor 10-MHz e 20-MHz US foram maiores que as encontradas pelo SD-OCT. Não foram observadas diferenças significativas na altura entre métodos SD-OCT e US. Todas as medidas foram estatisticamente semelhantes entre 20-MHz e 10-MHz. Conclusão: Para o parâmetro AP e T não foi detectada diferença entre as medidas utilizando US de 10-MHz e de 20-MHz. Porém estas medidas se mostraram significativamente maiores em relação à medida obtida com OCT. Para a altura, não foram detectadas diferenças estatística em relação à técnica utilizada, US 10-MHz e 20-MHz e SD-OCT.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Coroide/diagnóstico por imagem , Precisão da Medição Dimensional , Nevo Pigmentado/diagnóstico por imagem , Tamanho do Órgão , Neoplasias da Coroide/patologia , Estudos Prospectivos , Ultrassonografia/métodos , Tomografia de Coerência Óptica/métodos , Nevo Pigmentado/patologia
5.
Arq. bras. oftalmol ; 77(6): 382-387, Nov-Dec/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-735805

RESUMO

Purpose: To describe quantitative and qualitative features of eyes with advanced bullous keratopathy assessed using ultrasound biomicroscopy, before and after anterior stromal puncture (ASP) or amniotic membrane transplantation (AMT) procedures to relieve chronic pain. Methods: The present descriptive comparative study included 40 eyes of 40 patients with chronic intermittent pain due to bullous keratopathy who were randomly assigned to one of the two treatments (AMT or ASP). Ultrasound biomicroscopy (Humphrey, UBM 840, 50 MHz transducer, immersion technique) was used, and a questionnaire about pain intensity was completed preoperatively and postoperatively at days 90 and 180, respectively. Exclusion criteria were age<18 years, presence of concurrent infection, ocular hypertension, and absence of pain. Results: In a 180-day follow-up, the AMT group exhibited mean central corneal thickness (CCT), 899.4 µm preoperatively and 1122.5 µm postoperatively (p<0.001); mean epithelial thickness (ET), 156.4 µm preoperatively and 247.8 µm postoperatively (p<0.001); and mean stromal thickness (ST), 742.9 µm preoperatively and 826.3 µm postoperatively (p=0.005). The ASP group exhibited mean CCT, 756.7 µm preoperatively and 914.8 µm postoperatively (p<0.001); mean ET, 102.1 µm preoperatively and 245.2 µm postoperatively (p<0.001); and mean ST, 654.6 µm preoperatively and 681.5 µm postoperatively (p<0.999). Correlations between CCT and pain intensity in the AMT group (p=0.209 pre- and postoperatively) and the ASP group (p=0.157 preoperatively and p=0.426 at the 180-day follow-up) were not statistically significant. Epithelial and stromal edema, Descemet’s membrane folds, epithelial bullae, and the presence of interface fluid were frequently observed qualitative features. Conclusion: CCT increased over time in both groups. The magnitude of CCT did not correlate with pain intensity in the sample studied. The presence of interface ...


Objetivo: Descrever as características quantitativas e qualitativas da biomicroscopia ultrassônica (UBM) em olhos com ceratopatia bolhosa avançada, antes e após os procedimentos de punção estromal anterior (ASP) ou transplante de membrana amniótica (AMT) para alívio de dor crônica. Métodos: Estudo comparativo descritivo incluindo 40 olhos de 40 pacientes com dor crônica intermitente devido a ceratopatia bolhosa, randomizados em duas modalidades de tratamento (AMT e ASP). Biomicroscopia ultrassônica (Humphrey, UBM 840, transdutor de 50 MHz, técnica de imersão) foi utilizada, e um questionário de avaliação da intensidade da dor foi aplicado no pré-operatório, e após 90 e 180 dias de pós-operatório. Critérios de exclusão foram: idade abaixo de 18 anos, presença de infecção, hipertensão ocular, e ausência de dor. Resultados: No seguimento de 180 dias, o grupo Transplante de membrana amniótica apresentou: média da espessura corneana central (CCT): 899,4 µm (pré), 1.122,5 µm (pós-operatório) (p<0,001); média da espessura epitelial (ET): 156,4 µm (pré), 247,8 µm (pós-operatório) (p<0,001); média da espessura estromal (ST): 742,9 µm (pré), 826,3 µm (pós-operatório) (p=0,005), e, grupo ASP apresentou: CCT média: 756.7 µm (pré), 914,8µm (pós-operatório) (p<0,001); ET média: 102,1 µm (pré), 245,2 µm (pós-operatório) (p<0,001); ST média: 654,6 µm (pré), 681.5 µm (pós-operatório) (p<0,999). A correlação entre intensidade da dor e espessura corneana central no grupo AMT (p=0,209 pré e pós-operatórios) e no grupo ASP (p=0,157 pré-operatório e p=0,426 aos 180 dias de seguimento) não foi significativa. Edema epitelial e estromal, dobras na membrana de Descemet, bolhas epiteliais, e presença de fluido na interface foram características qualitativas frequentemente observadas. Conclusão: A espessura corneana central aumentou ao longo do tempo em ambos os grupos. A magnitude da espessura corneana central não interfere na intensidade da dor ...


Assuntos
Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Doenças da Córnea/cirurgia , Doenças da Córnea , Âmnio/transplante , Vesícula/cirurgia , Paquimetria Corneana , Substância Própria/patologia , Substância Própria/cirurgia , Substância Própria , Endotélio Corneano/patologia , Endotélio Corneano/cirurgia , Endotélio Corneano , Dor Ocular/cirurgia , Microscopia Acústica/métodos , Medição da Dor , Período Pós-Operatório , Período Pré-Operatório , Punções , Manejo da Dor/métodos , Cuidados Paliativos/métodos , Estatísticas não Paramétricas , Inquéritos e Questionários , Fatores de Tempo , Resultado do Tratamento
6.
Arq Bras Oftalmol ; 77(6): 382-7, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25627186

RESUMO

PURPOSE: To describe quantitative and qualitative features of eyes with advanced bullous keratopathy assessed using ultrasound biomicroscopy, before and after anterior stromal puncture (ASP) or amniotic membrane transplantation (AMT) procedures to relieve chronic pain. METHODS: The present descriptive comparative study included 40 eyes of 40 patients with chronic intermittent pain due to bullous keratopathy who were randomly assigned to one of the two treatments (AMT or ASP). Ultrasound biomicroscopy (Humphrey, UBM 840, 50 MHz transducer, immersion technique) was used, and a questionnaire about pain intensity was completed preoperatively and postoperatively at days 90 and 180, respectively. Exclusion criteria were age<18 years, presence of concurrent infection, ocular hypertension, and absence of pain. RESULTS: In a 180-day follow-up, the AMT group exhibited mean central corneal thickness (CCT), 899.4 µm preoperatively and 1122.5 µm postoperatively (p<0.001); mean epithelial thickness (ET), 156.4 µm preoperatively and 247.8 µm postoperatively (p<0.001); and mean stromal thickness (ST), 742.9 µm preoperatively and 826.3 µm postoperatively (p=0.005). The ASP group exhibited mean CCT, 756.7 µm preoperatively and 914.8 µm postoperatively (p<0.001); mean ET, 102.1 µm preoperatively and 245.2 µm postoperatively (p<0.001); and mean ST, 654.6 µm preoperatively and 681.5 µm postoperatively (p<0.999). Correlations between CCT and pain intensity in the AMT group (p=0.209 pre- and postoperatively) and the ASP group (p=0.157 preoperatively and p=0.426 at the 180-day follow-up) were not statistically significant. Epithelial and stromal edema, Descemet's membrane folds, epithelial bullae, and the presence of interface fluid were frequently observed qualitative features. CONCLUSION: CCT increased over time in both groups. The magnitude of CCT did not correlate with pain intensity in the sample studied. The presence of interface fluid was a qualitative feature specifically found in some patients who underwent AMT.


Assuntos
Doenças da Córnea/diagnóstico por imagem , Doenças da Córnea/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Âmnio/transplante , Vesícula/cirurgia , Paquimetria Corneana , Substância Própria/diagnóstico por imagem , Substância Própria/patologia , Substância Própria/cirurgia , Endotélio Corneano/diagnóstico por imagem , Endotélio Corneano/patologia , Endotélio Corneano/cirurgia , Dor Ocular/cirurgia , Feminino , Humanos , Masculino , Microscopia Acústica/métodos , Pessoa de Meia-Idade , Manejo da Dor/métodos , Medição da Dor , Cuidados Paliativos/métodos , Período Pós-Operatório , Período Pré-Operatório , Punções , Estatísticas não Paramétricas , Inquéritos e Questionários , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
7.
Arq Bras Oftalmol ; 76(4): 226-8, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24061833

RESUMO

PURPOSE: To relate the outcomes of 7 eyes of 7 patients in which a dexamethasone 0.7 mg implant (Ozurdex(®)) was placed inside the capsule bag after phacoemulsification and intraocular lens (IOL) implantation and compare with the fellow eyes, that were operated by the same technique and received dexamethasone eyedrops in the post-operatory. METHODS: Report review of 7 eyes of 7 patients who received dexamethasone 0.7 mg implant after phacoemulsification and IOL, comparing them to the fellow eyes. All the patients underwent bilateral cataract surgery, with one month interval, by the same technique and by experienced surgeons, without complications. Post operatory medication consisted of moxifloxacin eye drops for all the 14 eyes and topic dexamethasone for the 7 eyes that did not received the implant. RESULTS: Nuclear cataract classification (according to LOCS III) was 3.28 ± 0.69 in the implant eye group and 3.14 ± 0.83 in the fellow eye group. Postoperative best spectacle correct visual acuity (BSCVA) was 0.85 ± 0.12 and 0.87 ± 0.13, respectively in the implant and fellow eye groups. The intraocular pressure remained stable and similar to the pre-operative measurements. Anterior chamber reaction and cornea edema were similar in both groups in the follow-up. Two of the four no sutured pellet migrated to the anterior chamber during the first post-operative week and had to be repositioned. Another no sutured pellet dislocated and remained partially inside the capsule bag. The 3 patients with IOL haptic-sutured pellet had no complications. CONCLUSIONS: In the present study, dexamethasone 0.7 mg implant were effective in controlling the inflammation after phacoemulsification and IOL implantation, with no significant side effects.


Assuntos
Anti-Inflamatórios/administração & dosagem , Dexametasona/administração & dosagem , Implante de Lente Intraocular/métodos , Facoemulsificação/métodos , Complicações Pós-Operatórias/prevenção & controle , Administração Oftálmica , Idoso , Câmara Anterior/efeitos dos fármacos , Implantes de Medicamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/tratamento farmacológico , Fatores de Tempo , Resultado do Tratamento , Acuidade Visual
8.
Arq. bras. oftalmol ; 76(4): 226-228, jul.-ago. 2013. ilus, graf
Artigo em Inglês | LILACS | ID: lil-686558

RESUMO

PURPOSE: To relate the outcomes of 7 eyes of 7 patients in which a dexamethasone 0.7 mg implant (Ozurdex®) was placed inside the capsule bag after phacoemulsification and intraocular lens (IOL) implantation and compare with the fellow eyes, that were operated by the same technique and received dexamethasone eyedrops in the post-operatory. METHODS: Report review of 7 eyes of 7 patients who received dexamethasone 0.7 mg implant after phacoemulsification and IOL, comparing them to the fellow eyes. All the patients underwent bilateral cataract surgery, with one month interval, by the same technique and by experienced surgeons, without complications. Post operatory medication consisted of moxifloxacin eye drops for all the 14 eyes and topic dexamethasone for the 7 eyes that did not received the implant. RESULTS: Nuclear cataract classification (according to LOCS III) was 3.28 ± 0.69 in the implant eye group and 3.14 ± 0.83 in the fellow eye group. Postoperative best spectacle correct visual acuity (BSCVA) was 0.85 ± 0.12 and 0.87 ± 0.13, respectively in the implant and fellow eye groups. The intraocular pressure remained stable and similar to the pre-operative measurements. Anterior chamber reaction and cornea edema were similar in both groups in the follow-up. Two of the four no sutured pellet migrated to the anterior chamber during the first post-operative week and had to be repositioned. Another no sutured pellet dislocated and remained partially inside the capsule bag. The 3 patients with IOL haptic-sutured pellet had no complications. CONCLUSIONS: In the present study, dexamethasone 0.7mg implant were effective in controlling the inflammation after phacoemulsification and IOL implantation, with no significant side effects.


OBJETIVOS: Relatar os resultados de 7 olhos de 7 pacientes em que foi realizado o implante de dexametasona 0,7 mg (Ozurdex®) no saco capsular após facoemulsificação e implante de lente intraocular (LIO) e comparar com os olhos contralaterais, que foram operados pela mesma técnica e receberam colírio de dexametasona no pós-operatório. MÉTODOS: Relato de casos de 7 olhos de 7 pacientes que receberam o implante de dexametasona 0,7 mg após facoemulsificação e implante de LIO, comparando-os com os olhos contralaterais. Todos os pacientes foram submetidos a cirurgia de catarata bilateral, com intervalo de um mês entre as cirurgias, pela mesma técnica, por cirurgiões experientes e sem complicações. No pós-operatório foi utilizado colírio de moxifloxacino em todos os 14 olhos e dexametasona tópica nos olhos que não receberam o implante. RESULTADOS: A classificação da catarata de acordo com o LOCS III foi de 3,28 ± 0,69 no grupo que recebeu o implante e 3,14 ± 0,83 no grupo de olhos contralateral. A acuidade visual com melhor correção foi de 0,85 ± 0,12 e 0,87 ± 0,13 respectivamente nos grupos com e sem implante. A pressão intraocular permaneceu estável e similar aos valores pré-operatórios. A reação de câmara anterior e o edema de córnea foram similares nos dois grupos. Dois dos 4 implantes sem sutura migraram para a câmara anterior durante a primeira semana de pós-operatório e necessitaram de reposicionamento. Outro implante sem sutura teve deslocamento e permaneceu parcialmente dentro do saco capsular. Os 3 pacientes com implante suturado não tiveram complicações. CONCLUSÃO: No presente estudo, o implante de dexametasona 0,7 mg foi efetivo no controle da inflamação intraocular após cirurgia de facoemulsificação e implante de LIO, sem efeitos colaterais significativos.


Assuntos
Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Anti-Inflamatórios/administração & dosagem , Dexametasona/administração & dosagem , Implante de Lente Intraocular/métodos , Facoemulsificação/métodos , Complicações Pós-Operatórias/prevenção & controle , Administração Oftálmica , Câmara Anterior/efeitos dos fármacos , Implantes de Medicamento , Complicações Pós-Operatórias/tratamento farmacológico , Fatores de Tempo , Resultado do Tratamento , Acuidade Visual
9.
Arq. bras. oftalmol ; 75(6): 415-419, nov.-dez. 2012. ilus, tab
Artigo em Inglês | LILACS | ID: lil-675625

RESUMO

PURPOSE: Optical coherence tomography (OCT) is valuable for macula evaluation. However, as this technique relies on light energy it cannot be performed in the presence of opaque media. In such cases, the ultrasound (US) may predict some macular features. The aim of this study was to characterize images obtained by ultrasound with 10 and 20-MHz transducers comparing to OCT, as well as to analyze the relationship between the vitreous and retina in eyes with macular hole (MH). METHODS: 29 eyes of 22 patients with biomicroscopic evidence of MH at different stages were included. All patients were evaluated using ultrasonography with 10 and 20-MHz transducers and OCT. RESULTS: OCT identified signs of MH in 25 of 29 eyes. The remaining 4 cases not identified by US were pseudoholes caused by epiretinal membranes. In MH stages I (2 eyes) and II (1 eye), both transducers were not useful to analyze the macular thickening, but suggestive findings as macular irregularity, operculum or partial posterior vitreous detachment (PVD) were highlighted. In stages III (14 eyes) and IV (5 eyes), both transducers identified the double hump irregularity and thickening. US could measure the macular thickness and other suggestive findings for MH: operculum, vitreomacular traction and partial or complete PVD. In cases of pseudoholes, US identified irregularities macular contour and a discrete depression. CONCLUSION: 10-MHz US was useful for an overall assessment of the vitreous body as well as its relationship to the retina. The 20-MHz transducer allowed valuable information on the vitreomacular interface and macular contour. OCT provides superior quality for fine morphological study of macular area, except in cases of opaque media. In these cases, and even if OCT is not available, the combined US study is able to provide a valid evaluation of the macular area improving therapeutic approach.


OBJETIVO: A tomografia de coerência óptica (OCT) é um método diagnóstico valioso para estudo da mácula. Entretanto, por se basear na energia luminosa, não pode ser realizada quando existe opacidade de meios. Nesses casos, o ultrassom (US) pode predizer algumas características maculares. Este estudo teve como objetivos caracterizar imagens obtidas por US com transdutores de 10 e 20-MHz comparadas ao OCT, assim como analisar a relação vitreorretiniana em olhos com buraco macular (BM). MÉTODOS: Vinte e nove olhos de 22 pacientes com evidência biomicroscópica de BM em diferentes estágios foram incluídos. Todos os pacientes foram avaliados com ultrassonografia utilizando transdutores de 10 e 20-MHz e OCT de domínio espectral. RESULTADOS: OCT diagnosticou BM em 25 dentre 29 olhos estudados. Os 4 casos não identificados por US eram pseudoburacos decorrentes de membrana epirretiniana. Nos BM estágios I (2 olhos) e II (1 olho), ambos transdutores não foram úteis para analisar o espessamento macular, mas foram identificados sinais sugestivos como irregularidade macular, opérculo ou descolamento parcial do vítreo posterior (DVP). Nos estágios III (14 olhos) e IV (5 olhos), ambos transdutores identificaram irregularidade, dupla corcova e espessamento macular. O US foi capaz de medir a espessura macular e identificar outros indícios de BM, como opérculo, tração vitreorretiniana e DVP. Em pseudoburacos, o US identificou irregularidades no contorno macular e discreta depressão. CONCLUSÃO: US de 10-MHz foi útil para uma avaliação global do corpo vítreo e sua relação à retina. O US de 20-MHz forneceu informações importantes sobre a junção vitreorretiniana e contorno macular. OCT fornece qualidade superior para estudo morfológico da região macular, exceto em casos de opacidade de meios. Nesses casos, ou quando o exame tomográfico não for disponível, o estudo ultrassonográfico de 10 e 20-MHz é capaz de proporcionar análise válida da região macular e auxiliar na abordagem terapêutica.


Assuntos
Idoso , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Retina , Perfurações Retinianas , Tomografia de Coerência Óptica/métodos , Corpo Vítreo , Descolamento do Vítreo , Macula Lutea , Microscopia Acústica , Perfurações Retinianas/patologia , Transdutores , Corpo Vítreo/patologia , Descolamento do Vítreo/patologia
10.
Arq Bras Oftalmol ; 75(6): 415-9, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23715145

RESUMO

PURPOSE: Optical coherence tomography (OCT) is valuable for macula evaluation. However, as this technique relies on light energy it cannot be performed in the presence of opaque media. In such cases, the ultrasound (US) may predict some macular features. The aim of this study was to characterize images obtained by ultrasound with 10 and 20-MHz transducers comparing to OCT, as well as to analyze the relationship between the vitreous and retina in eyes with macular hole (MH). METHODS: 29 eyes of 22 patients with biomicroscopic evidence of MH at different stages were included. All patients were evaluated using ultrasonography with 10 and 20-MHz transducers and OCT. RESULTS: OCT identified signs of MH in 25 of 29 eyes. The remaining 4 cases not identified by US were pseudoholes caused by epiretinal membranes. In MH stages I (2 eyes) and II (1 eye), both transducers were not useful to analyze the macular thickening, but suggestive findings as macular irregularity, operculum or partial posterior vitreous detachment (PVD) were highlighted. In stages III (14 eyes) and IV (5 eyes), both transducers identified the double hump irregularity and thickening. US could measure the macular thickness and other suggestive findings for MH: operculum, vitreomacular traction and partial or complete PVD. In cases of pseudoholes, US identified irregularities macular contour and a discrete depression. CONCLUSION: 10-MHz US was useful for an overall assessment of the vitreous body as well as its relationship to the retina. The 20-MHz transducer allowed valuable information on the vitreomacular interface and macular contour. OCT provides superior quality for fine morphological study of macular area, except in cases of opaque media. In these cases, and even if OCT is not available, the combined US study is able to provide a valid evaluation of the macular area improving therapeutic approach.


Assuntos
Retina/diagnóstico por imagem , Perfurações Retinianas/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Corpo Vítreo/diagnóstico por imagem , Descolamento do Vítreo/diagnóstico por imagem , Idoso , Criança , Feminino , Humanos , Macula Lutea , Masculino , Microscopia Acústica , Pessoa de Meia-Idade , Perfurações Retinianas/patologia , Transdutores , Corpo Vítreo/patologia , Descolamento do Vítreo/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...