Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
ACS Omega ; 8(6): 5885-5892, 2023 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-36816670

RESUMO

A new graphene quantum dot (GQD) fabrication method is presented, which employs a lithographic approach based on self-assembled Au nanoparticles formed by solid-state dewetting. The GQDs are formed by the patterned etching of a graphene layer enabled by Au nanoparticles, and their size is controllable through that of the Au nanoparticles. GQDs are fabricated with four different diameters: 12, 14, 16, and 27 nm. The geometrical features and lattice structures of the GQDs are determined using transmission electron microscopy (TEM). Hexagonal lattice fringes in the TEM image and G- and 2D-band Raman scattering evidence the graphitic characteristics of the GQDs. The oxygen content can be controlled by thermal reduction under a hydrogen atmosphere. In GQDs, the absorption peak wavelengths in the ultraviolet range tend to decrease as the size of the GQDs decreases. They also exhibit apparent photoluminescence (PL). The PL peak wavelength is approximately 600 nm and becomes shorter as the size of the GQDs decreases. The blue shift in the optical absorption and PL of the smaller GQDs is attributed to the quantum confinement effect. The proposed GQD fabrication method can provide a way to control the physical and chemical properties of GQDs via their size and oxygen content.

2.
Cureus ; 14(6): e26013, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35855258

RESUMO

Foix-Chavany-Marie syndrome (FCMS) is characterized by bilateral facio-glosso-pharyngo-masticatory paralysis of voluntary muscles due to bilateral infarction in the anterior opercular region of the brain. Here, we report a case of a 52-year-old female who presented with FCMS due to an acute left anterior opercular stroke in the setting of a chronic asymptomatic right opercular infarct and asymptomatic bilateral cerebellar infarcts. She also had a concurrent acute-on-chronic episode of congestive heart failure exacerbation. She made a significant recovery by the time of hospital discharge.

3.
Plants (Basel) ; 10(10)2021 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-34685814

RESUMO

Cell division of unicellular microalgae is a fascinating process of proliferation, at which whole organelles are regenerated and distributed to two new lives. We performed dynamic live cell imaging of Euglena gracilis using optical microscopy to elucidate the mechanisms involved in the regulation of the eyespot and flagellum during cell division and distribution of the organelles into the two daughter cells. Single cells of the wild type (WT) and colorless SM-ZK cells were confined in a microfluidic device, and the appearance of the eyespot (stigma) and emergent flagellum was tracked in sequential video-recorded images obtained by automatic cell tracking and focusing. We examined 12 SM-ZK and 10 WT cells and deduced that the eyespot diminished in size and disappeared at an early stage of cell division and remained undetected for 26-97 min (62 min on average, 22 min in deviation). Subsequently, two small eyespots appeared and were distributed into the two daughter cells. Additionally, the emergent flagellum gradually shortened to zero-length, and two flagella emerged from the anterior ends of the daughter cells. Our observation revealed that the eyespot and flagellum of E. gracilis are degraded once in the cell division, and the carotenoids in the eyespot are also decomposed. Subsequently, the two eyespots/flagella are regenerated for distribution into daughter cells. As a logical conclusion, the two daughter cells generated from a single cell division possess the equivalent organelles and each E. gracilis cell has eternal or non-finite life span. The two newly regenerated eyespot and flagellum grow at different rates and mature at different timings in the two daughter cells, resulting in diverse cell characteristics in E. gracilis.

4.
Plants (Basel) ; 10(7)2021 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-34371614

RESUMO

Gravitaxis is one of the most important issues in the growth of microalgae in the water column; it determines how easily cells receive sunlight with a comfortable intensity that is below the damaging threshold. We quantitatively investigated and analyzed the gravitaxis and cell multiplication of Euglena gracilis using vertically placed microchambers containing a single cell. A temporal change in gravitaxis and cell multiplication was observed after transferring the cells to fresh culture medium for 9 days. We performed 29 individual experiments with 2.5 mm × 2.5 mm × 0.1 mm square microchambers and found that the cells showed positive, negative, and moderate gravitaxis in 8, 7, and 14 cases, respectively, after transferring to fresh culture medium. A common trend was observed for the temporal change in gravitaxis for the eight initially positive gravitaxis cases. The cells with initially positive gravitaxis showed a higher rate of cell multiplication than those with initially negative gravitaxis. We also discussed the gravitaxis mechanism of E. gracilis from the observed trend of gravitaxis change and swimming traces. In addition, bioconvection in a larger and thicker chamber was investigated at a millimeter scale and visualized.

5.
Analyst ; 146(6): 1932-1939, 2021 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-33492316

RESUMO

Capillary-driven microfluidic devices are of significant interest for on-site analysis because they do not require external pumps and can be made from inexpensive materials. Among capillary-driven devices, those made from paper and polyester film are among the most common and have been used in a wide array of applications. However, since capillary forces are the only driving force, flow is difficult to control, and passive flow control methods such as changing the geometry must be used to accomplish various analytical applications. This study presents several new flow control methods that can be utilized in a laminate capillary-driven microfluidic device to increase available functionality. First, we introduce push and burst valve systems that can stop and start flow. These valves can stop flow for >30 min and be opened by either pressing the channel or inflowing other fluids to the valve region. Next, we propose flow control methods for Y-shaped channels that enable more functions. In one example, we demonstrate the ability to accurately control concentration to create laminar, gradient, and fully mixed flows. In a second example, flow velocity in the main channel is controlled by adjusting the length of the inlet channel. In addition, the flow velocity is constant as the inlet length increases. Finally, the flow velocity in the Y-shaped device as a function of channel height and fluid properties such as viscosity and surface tension was examined. As in previous studies on capillary-driven channels, the flow rate was affected by each parameter. The fluidic control tools presented here will enable new designs and functions for low cost point of need assays across a variety of fields.

6.
Anal Chem ; 91(7): 4868-4875, 2019 04 02.
Artigo em Inglês | MEDLINE | ID: mdl-30848879

RESUMO

The viscosity of biofluids can be used to acquire meaningful medical information on the conditions of a patient but has seldom been utilized in clinical practices owing to cumbersome measurement procedures and the need for large sample volumes. We present a colorimetric method to measure the viscosity of blood plasma using a paper-based viscometer developed in this study specifically for clinical diagnosis. The proposed analytical device consists of multilayered papers with fluid-loading, -mixing, and -measuring regions, and it can be fabricated readily in a simple manner using three-layered paper channels and tape. Moreover, the colorimetric analysis enables viscosity estimations by analyzing a single optical image. To validate the device performance, we measured the viscosities of fluids such as glycerin aqueous solutions, bovine-serum-albumin solution, dimethyl sulfoxide, and blood plasma. We found that the measured viscosities were in good agreement with the reference values. Finally, we developed a simple smartphone application for the viscosity measurements that helped enhance the convenience and utility of the paper-based viscometer while maintaining the measurement accuracy.


Assuntos
Colorimetria , Glicerol/sangue , Papel , Smartphone , Viscosidade Sanguínea , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...