Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Toxics ; 11(2)2023 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-36850990

RESUMO

This study was conducted to determine the optimal boiling time to reduce ptaquiloside (PTA) and to carry out a risk assessment for PTA, a representative toxic substance found in bracken fern (BF; Pteridium aquilinum), which is frequently consumed as food in East Asian countries. High-performance liquid chromatography showed that the concentration of PTA in BF was reduced by up to 99% after boiling for 20 min. Risk assessment results showed that the cancer margin of exposure (MOE; ≥ 25,000 = safe) to PTA for an average daily exposure scenario after boiling BF for 20 min was considered safe. In addition, the non-cancer MOE (≥ 300 = safe) to PTA under an average daily exposure scenario after BF boiling for 20 min was considered safe. However, human exposure to PTA was considered unsafe under the non-boiled BF exposure and maximum daily exposure scenarios. Therefore, boiling BF for at least 20 min is recommended before consumption, to reduce exposure to PTA as much as possible.

2.
Genomics Inform ; 20(4): e46, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36617653

RESUMO

Influenza A virus (IAV) is the most widespread pathogen causing human respiratory infections. Although polymerase chain reaction (PCR)-based methods are currently the mostcommonly used tools for IAV detection, PCR is not ideal for point-of-care testing. In thisstudy, we aimed to develop a more rapid and sensitive method than PCR-based tools todetect IAV using loop-mediated isothermal amplification (LAMP) technology. We designedreverse-transcriptional (RT)-LAMP primers targeting the hemagglutinin gene. RNAs fromreference H1N1 and H3N2 showed specific RT-LAMP signals with the designed primers.We optimized the reaction conditions and developed universal reaction conditions for bothLAMP assays. Under these conditions, the detection limit was 50 copies for both RT-LAMPassays. There was no non-specific signal to 19 non-IAV respiratory viruses, such as influenza B virus, coronaviruses, and respiratory syncytial viruses. Regarding the reaction time, apositive signal was detected within 25 min after starting the reaction. In conclusion, ourRT-LAMP assay has high sensitivity and specificity for the detection of the H1 and H3 subtypes, making it suitable for point-of-care IAV testing.

3.
Toxicol Res ; 35(2): 103-117, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31015893

RESUMO

The mixture of 5-chloro-2-methylisothiazol-3(2H)-one (CMIT) and 2-methylisothiazol-3(2H)-one (MIT), CMIT/MIT, is a preservative in cosmetics. CMIT/MIT is a highly effective preservative; however, it is also a commonly known skin sensitizer. Therefore, in the present study, a risk assessment for safety management of CMIT/MIT was conducted on products containing 0.0015% of CMIT/MIT, which is the maximum MIT level allowed in current products. The no observed adverse effect level (NOAEL) for CMIT/MIT was 2.8 mg/kg bw/day obtained from a two-generation reproductive toxicity test, and the skin sensitization toxicity standard value for CMIT/MIT, or the no expected sensitization induction level (NESIL), was 1.25 µg/cm2/day in humans. According to a calculation of body exposure to cosmetics use, the systemic exposure dosage (SED) was calculated as 0.00423 mg/kg bw/day when leave-on and rinse-off products were considered. Additionally, the consumer exposure level (CEL) amounted to 0.77512 µg/cm2/day for all representative cosmetics and 0.00584 µg/cm2/day for rinse-off products only. As a result, the non-cancer margin of safety (MOS) was calculated as 633, and CMIT/MIT was determined to be safe when all representative cosmetics were evaluated. In addition, the skin sensitization acceptable exposure level (AEL)/CEL was calculated as 0.00538 for all representative cosmetics and 2.14225 for rinse-off products; thus, CMIT/MIT was considered a skin sensitizer when all representative cosmetics were evaluated. Current regulations indicate that CMIT/MIT can only be used at concentrations 0.0015% or less and is prohibited from use in other cosmetics products. According to the results of this risk assessment, the CMIT/MIT regulatory values currently used in cosmetics are evaluated as appropriate.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...